30 records · Page 2

Characterization of Impure Plutonium Oxide Neutron Calibration Standards through Evaluation by Neutron Multiplicity Equations

Plutonium oxide calibration standards STD4C, STD6C and STD8C have been historically used, and are currently the only MT52 standards in use, for calibration and measurement control program of Passive/Active Neutron Coincidence Counter known as PAN1 at PF-4. In this paper, previously measured high-statistics data are used in conjunction with neutron multiplicity equations to determine multiplication M and α parameter of these standards as the explicit knowledge of these parameters may allow quantification of precision and bias of accountability measurements of different material types and matrices of items.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AWCC Simulations

Neutron well counters provide a means to measure fissile mass by detecting coincident neutrons, which is a unique signature to fission. For coincidence counting, mass is determined using a calibration curve established with items that have the same material characteristics. Multiplicity analysis solves the point model equations for mass using known detector parameters. In both cases, mass measurements may exhibit a bias due to item characteristics and should be corrected for. Experiments can be done to estimate bias and material effects, but they require having both the well counter and the material well defined. In pursuit of estimating measurement bias and uncertainty in a High Efficiency Neutron Counter (HENC), an MCNP simulation was matched to measurements performed with an Active Well Coincidence Counter (AWCC) to de ne a neutron source term. The neutron source term will be used to predict measurement performance of similar material types in a HENC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluated 238 U(n,f) Average Prompt Fission Neutron Multiplicities Including the CGMF Model

This report documents an evaluation of the average prompt fission neutron multiplicity, $\overline{v}_p$, of 238 U from 800 keV to MeV. This evaluation had to be re-done from “scratch” as the input to previous $\overline{v}_p$ evaluations, specifically ENDF/B-VIII.0, was not found. That means that all available experimental data were re-analyzed and uncertainties were re-estimated. The new evaluated 238 U $\overline{v}_p$ based on only experimental data differs distinctly from ENDF/B-VIII.0 $\overline{v}_p$ from 2 to 4.5 MeV, and from 6 to 7 MeV, and is otherwise similar. The difference from 2 to 4.5 MeV stems from the fact that ENDF/B-VIII.0 was tweaked in this energy range to data of Frehaut, while two other, equally trustworthy, data sets would indicate an evaluated 238 U $\overline{v}_p$ that is up to 2% higher. Also, second chance fission in ENDF/B-VIII.0 was smoothed over from 6–7 MeV. Another major difference to ENDF/B-VIII.0 is that one of the evaluations presented here includes model information from the Hauser-Feshbach fission fragment decay code CGMF, while ENDF/B-VIII.0 is based purely on experimental data. CGMF links several fission quantities with each other; $\overline{v}_p$ is predicted by assumptions made on, e.g., pre-neutron emission yields as a function of mass, the total kinetic energy, or spin and parity of fission fragments. This allows to validate the new 238 U $\overline{v}_p$ by using CGMF parameters obtained from fitting to experimental 238 U $\overline{v}_p$ to predict yields as a function of mass, the average total kinetic energy, or the mean energy of the prompt fission neutron spectrum. These model-predicted values can then be compared to experimental and evaluated data. The model-predicted fission-observable values using evaluated parameters obtained here are reasonably close to experimental data for some observables, but are farther away from experimental data related to TKE observables. In addition to that, the evaluated 238 U(n,f) $\overline{v}_p$ shows similar deviations from ENDF/B-VIII.0 as for the evaluation with only experimental data. This difference is expected to lead to changes in simulated effective neutron multiplication factor, $k_{eff}$ of ICSBEP critical assemblies that are sensitive to 238 U in the fast range (BigTen, Flattop, Flattop-Pu). These changes in $k_{eff}$ need to be counter-balanced. Chi-Nu PFNS experimental data are expected to be released in the next few months that might lead to the needed changes in the PFNS. Until then, we hold off in benchmarking the new 238 U(n,f) $\overline{v}_p$ as well as submitting it to ENDF/B-VIII.1. Also, new high-precision 238 U $\overline{v}_p$ are expected to be measured by the CEA in the next two years that will shed further light on question on 238 U $\overline{v}_p$ from 2–4.5 and 6–7 MeV.

238U↗

An Evaluation of a Neutron Time Correlated Interrogation Method for Measurement of Fissile Content in Research Reactor Spent Fuel Assemblies

There are many research reactors worldwide that have been, or are being converted from the use of high enrichment uranium (HEU) to low enrichment uranium (LEU, < 20% enriched). The verification of fissile content and initial enrichment of the spent fuel is needed for the effective safeguards of the fuel. The advanced experimental fuel counter (AEFC) was developed for the measurement of spent fuel rods and assemblies from research reactors for safeguards verification. This measurement system contains components for active neutron interrogation, passive neutron totals counting, neutron coincidence counting, and gross gamma-ray counting. This report presents the first application of the time correlated interrogation technique for the measurement of the 235 U content in research reactor spent fuel assemblies. The technique, called time correlated induced fission (TCIF), uses a 252 Cf neutron source to irradiate the fuel assembly, and the subsequent induced fission events in the fissile material are measured by coincidence counting. The doubles rates are enhanced by having the neutron trigger events from both the 252 Cf source and the induced fission neutrons in the same time gate in the coincidence analysis. The average neutrons per fission of the 252 Cf source is 3.76 and the induced fission neutrons for 235 U is 2.44, so the number of neutrons that are produced is higher than for random neutron interrogation. This high effective neutron number increases the multiplicity counting rates and reduces the statistical error. The background coincidence counts from the 252 Cf are reduced by the water in the sample cavity and the polyethylene surrounding the 3 He detector tubes. This method of active neutron interrogation has been applied to the measurement of spent research reactor (IRT) fuel assemblies. The advanced experimental fuel counter (AEFC) was used to compare the TCIF method with the typically used AmLi neutron interrogation source that emits neutrons that are random in time. The statistical uncertainty for the use of the random neutron source (AmLi) and the time correlated source ( 252 Cf) for spent fuel interrogations was evaluated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Samarkand complex setup for investigation of cosmic ray variation in the energy range of 7 10 (9) - 10 (15) eV

The Samarkand complex setup is aimed at the study of cosmic ray variations in a wide energy range from 7 billion eV (which corresponds to the geomagnetic threshold in the region of Samarkand) up to approx 10 to the 15th power to 10 to the 16th power eV. The setup consists of four 6-counter sections of neutron supermonitor with counters SNM-15 and 48 scintillator detectors (1 sq m each) placed under and above the supermonitor. The effective area of the setup for recording neutrons and muons is 24 sq m. The setup can register time variations of the following cosmic ray components: (1) the total neutron counting rate, (2) counting rates for neutrons of different multiplicity, (3) soft-muon fluxes, (4) hard-muon fluxes at various zenith and azimuth angles, (5) electron-photon component, (6) extensive air showers (EAS) induced by primary particles in a wide energy range and accompanied or not accompanied by muons and neutrons.

Dorman, L. I.↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Investigation of Target keff Search for Fuel Feed in MSRs

Fluid fuel molten salt reactor (MSR) concepts may achieve continuous-at-power operation with continuous or batch fresh fuel feed to counter reactivity loss from fuel burnup and fission product buildup. Accurate modeling and simulation of MSRs requires consideration of online fuel feed during depletion as well as a capability to determine the required feed amount to maintain a target multiplication factor (keff). As a first step supporting a full implementation of a new search capability into the SCALE code system’s TRITON reactor physics and depletion sequence, a preliminary investigation was performed to identify the best approach for a critical feed search capability considering computation time and accuracy. Using a simple iterative approach in which initial feed amounts were guessed based on previous depletion steps, the main drivers of computation time were found as the Monte Carlo neutron transport settings and the applied tolerance for the target keff. In the applied model, with tight convergence criteria (keff convergence to 8 pcm and a tolerance of ±15 pcm), the critical search calculation required twice the number of neutron transport calculations compared to a depletion calculation without critical search. In contrast, with a relaxed tolerance of ±50 pcm, the overall computation time for the critical search for merely increased by 30-40%. Further studies will be performed before implementing the critical search capability into TRITON.

Faulkner, Jonathon [ORNL]↗

Total Measurement Uncertainty in Neutron Coincidence Multiplicity Analysis

Neutron multiplicity counting is the most commonly used nondestructive assay technique for determining the plutonium mass within containers of scrap PuO 2 or mixed oxide (MOX). In multiplicity analysis, the 240 Pu eff mass, leakage multiplication, and alpha ratio (the ratio of [α, n]-to-spontaneous fission neutron production) are the three primary unknown sample properties. They must be determined simultaneously. To solve for these three unknowns in a multiplicity assay, three measured values are needed: the singles, doubles, and triples neutron count rates. While the analysis is limited to solving for three unknowns, there are many additional factors that impact the observed count rates and contribute to the measurement uncertainty. In this study we investigate the various uncertainty contributors for the multiplicity analysis through a combination of traditional uncertainty propagation techniques supplemented by Monte Carlo simulations to address the dependences not explicitly expressed by the point source model. Uncertainties arising from counting statistics, calibration parameters, calibration method, nuclear data, and various material characteristics (isotopic abundances, chemical form, density, and impurities) are considered. A Total Measurement Uncertainty (TMU) estimate is then developed from these uncertainty contributors. This study is confined to multiplicity analysis of items commonly encountered in international safeguards applications. That is, the study focused on Pu oxides and MOX materials for the masses ranging up to 4000 grams total Pu. Multiplicity measurements were simulated using MCNP V6 based on the Plutonium Scrap Multiplicity Counter (PSMC), Epithermal Multiplicity Counter (ENMC), Pyrochemical Multiplicity Counter, and Large Epithermal Multiplicity Counter (LEMC) for this study; however, this report focuses on the parameterization of the uncertainties for the PSMC. The performance differences between the PSMC and the other multiplicity counting systems are relatively small, primarily manifesting in the impact on measurement precision so that the evaluation developed for the PSMC can be applied to the other multiplicity counting systems. Finally an analysis tool, the Multiplicity TMU Estimator, was developed from this study to serve as an aid for evaluation of the total measurement uncertainty of multiplicity assay results obtained from the commonly used INCC acquisition and analysis software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reconstructing 3D asymmetries in laser-direct-drive implosions on OMEGA

Three-dimensional reconstruction algorithms have been developed which determine the hot-spot velocity, hot-spot apparent ion temperature distribution, and fuel areal density distribution present in laser-direct-drive inertial con finement fusion implosions on the OMEGA laser. These reconstructions rely on multiple independent measurements of the neutron energy spectrum emitted from the fusing plasma. Measurements of the neutron energy spectrum on OMEGA are made using a suite of quasi-orthogonal neutron time-of-flight detectors and a magnetic recoil spectrometer. These spectrometers are positioned strategically around the OMEGA target chamber to provide unique 3-D measurements of the conditions of the fusing hot spot and compressed fuel near peak compression. Here, the uncertainties involved in these 3-D reconstructions are discussed and are used to identify a new nTOF diagnostic line of sight which when built will reduce the uncertainty in the hot-spot apparent ion temperature distribution from 0.7 to < 0.4 keV.

47 OTHER INSTRUMENTATION↗