Search NASA⌕ Search

SEARCH · Search NASA

Results for “oscilloscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NUM-DAT File Format Specification: Used in M-9 Gun Experiment Data Archiving

The M-9 Shock and Detonation Physics group executes experiments on gun and explosive platforms with large numbers of oscilloscopes used for data acquisition. The data acquisition from these oscilloscopes was automated many years ago using a custom piece of software called RunDig . The default save format from this software is a custom structure referred to as "NUM-DAT" format. This file format includes a text ".DAT" file which is a header file used to interpret the binary ".NUM" file which contains the oscilloscope data. The data save format was originally developed by John Vorthman and has been in use by M-9 personnel for over 20 years. This data format has been used for archiving data from experiments performed by M-9 personnel at TA-40, TA-39, and the TA-55 Impact Test Facility. Numerous custom analysis and visualization programs have also been developed, and continue to be used, that utilize this data format. This document describes the NUM-DAT format and provides code examples for reading the format and converting it to other formats.

47 OTHER INSTRUMENTATION↗

The Stanford-Ames portable echocardioscope - A case study in technology transfer

The paper describes a lightweight portable battery-powered echocardioscope fabricated largely from readily available components. The transducer contains a piezoelectric crystal which acts as both an ultrasound pulse emitter and echo receiver, and the oscilloscope is of modular construction. The oscilloscope display can be produced in any of three different modes: A-mode, B-mode, and M-mode (time-motion) by sweeping the intensified points of light of the B-mode display vertically along the oscilloscope face. The resulting display can be photographed in a time exposure, thus providing a hardcopy record for the patient's chart or physician's records. The device is clinically validated on both normal subjects and patients by experienced echocardiographers.

Schmidt, G.↗

Force-Balance Dynamic Display

Balance dynamic display unit (BDDU) is compact system conditioning six dynamic analog signals so they are monitored simultaneously in real time on single-trace oscilloscope. Typical BDDU oscilloscope display in scan mode shows each channel occupying one-sixth of total trace. System features two display modes usable with conventional, single-channel oscilloscope: multiplexed six-channel "bar-graph" format and single-channel display. Two-stage visual and audible limit alarm provided for each channel.

Ferris, Alice T.↗

Sub-nanosecond time-resolved radiation measurement using x-ray focusing crystal spectrometers

Here, in this paper, we describe a technique using a crystal spectrometer, a silicon-diode detector, and a filtered photoconductive detector to monitor photon energies in the L-shell (0.9–1 keV) and K-shell regimes for nickel and copper hybrid X-pinch x-ray sources. The detectors, system cabling, and an 8 GHz digital oscilloscope in combination enable time resolution better than 200 ps for photoconductive detectors and 700 ps for silicon-diode detectors of the K- and L-shell radiation signals, respectively. We substantially improve the relative timing of signals obtained using the oscilloscope by using an x-ray streak camera with a crystal spectrometer to monitor the L-shell line spectra and, separately, the K-shell line spectra relative to the continuum burst to better than 17 ps time resolution. This combination of instruments enabled and validated a new method by which plasma conditions in nickel and copper X-pinches can be assessed immediately before and after the ~30 ps continuum x-ray burst produced by 370 kA hybrid X-pinches. In general, the method described here can be applied to observe otherwise highly filter-absorbed radiation in the presence of a broad spectrum of higher energy radiation by combining x-ray crystals and detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remote Instrumentation and Data Acquisition

This poster outlines the development and implementation of a remote data acquisition system for waveform analysis using a Rohde & Schwarz oscilloscope. The project involved capturing waveform data, and transferring it to a local machine for visualization and analysis. The core logic was developed in C++ with a focus on object oriented programming and the use of polymorphism so the main application can interact with any instrument without knowing its exact type, simplifying the overall logic and making it easier to add or swap out components without changing the rest of the codebase.. The system issues Standard Commands for Programmable Instruments (SCPI) via a socket connection and parses the oscilloscope s ASCII waveform data. The C++ application was containerized using Docker for ease of portability, and reproducibility. Emphasis was placed on secure networking practices, error handling, and effective data capture. The report describes the technical steps taken, challenges encountered, and future work, providing insight into the practical integration of hardware interfacing with remote computational environments.

Parikh, Jaymil [Illinois U., Urbana]↗

X-Y plotter adapter developed for SDS-930 computer

Graphical Display Adapter provides a real time display for digital computerized experiments. This display uses a memory oscilloscope which records a single trace until erased. It is a small hardware unit which interfaces with the J-box feature of the SDS-930 computer to either an X-Y plotter or a memory oscilloscope.

Robertson, J. B.↗

Development of a wideband wattmeter as a laboratory instrument

A portable, solid state, wideband wattmeter has been developed as a general purpose type of laboratory instrument. Its circuit and component investigations and evaluation data are presented. A prototype unit was used extensively, and served as the basis for a second instrument incorporating refined circuitry and improved packaging. The wattmeter provides true four quadrant operation which permits instantaneous indication of real power as an oscilloscope display. Major performance factors are: frequency bandwidth DC to 1 MHz plus or minus 1 db; current range 10 mA to 100 amperes peak; voltage range 1 volt to 1000 volts peak; accuracy plus or minus 2% of full scale reading. Oscilloscope data for typical switching transients in a transistor inverter circuit are included.

Landes, L. G.↗

Prototype ultrasonic instrument for quantitative testing

A prototype ultrasonic instrument has been designed and developed for quantitative testing. The complete delivered instrument consists of a pulser/receiver which plugs into a standard oscilloscope, an rf power amplifier, a standard decade oscillator, and a set of broadband transducers for typical use at 1, 2, 5 and 10 MHz. The system provides for its own calibration, and on the oscilloscope, presents a quantitative (digital) indication of time base and sensitivity scale factors and some measurement data.

Lynnworth, L. C.↗

BEAMR: An interactive graphic computer program for design of charged particle beam transport systems

A computer program for a PDP-15 is presented which calculates, to first order, the characteristics of charged-particle beam as it is transported through a sequence of focusing and bending magnets. The maximum dimensions of the beam envelope normal to the transport system axis are continuously plotted on an oscilloscope as a function of distance along the axis. Provision is made to iterate the calculation by changing the types of magnets, their positions, and their field strengths. The program is especially useful for transport system design studies because of the ease and rapidity of altering parameters from panel switches. A typical calculation for a system with eight elements is completed in less than 10 seconds. An IBM 7094 version containing more-detailed printed output but no oscilloscope display is also presented.

Leonard, R. F.↗

Laser-scanning techniques for rapid ballistics identification

Two different laser-scanning methods may be utilized. In each case scanned cylindrical bullet surface is displayed ""unwrapped'' on oscilloscope screen. Bullets are compared by photographing each display and superimposing negatives of two images. With some modifications bullets can be scanned and compared by superimposing images on screen of dual-beam oscilloscope.

Woodburgy, R. C.↗

Laser pulse analysis

The paper describes attempts to improve the satellite range measurements obtained with a laser ranging system. The transmitted and received ranging pulses were displayed on an oscilloscope and photographed. The pulse images were measured and the measurement data analyzed by computer. The range errors are reduced by utilizing information contained in the shapes of the return pulses. The problem of determining the center of the irregular return pulse is discussed. The results of the investigation show that the corrections made from the oscilloscope photographs improve the accuracy of the range measurements.

Lehr, C. G.↗

Video method for studying optical fields

Approach for measuring intensity distribution in optical field records pattern with vidicon and then displays it on oscilloscope, using vertical sweep as trigger. Single horizontal lines in field can be isolated by using sweep delay feature of oscilloscope.

Mezrich, R. S.↗

Detection of Floating Inputs in Logic Circuits

Simple modification of oscilloscope probe allows easy detection of floating inputs or tristate outputs in digital-IC's. Oscilloscope probe easily modified with 1/4 W resistor and switch for detecting floating inputs in CMOS logic circuits.

Cash, B.↗

A transient digitiser for fast air shower events

Air shower structure are often measured on time scales of a few nanoseconds. Longitudinal disk structure near the core is of the order of meters in dimension, air Cerenkov pulses have full widths at half maximum of the order of tens of nanoseconds, and fast timing over typical arrays is usually measured to nanosecond accuracy. oscilloscopes can be used but have very limited dynamic range and are expensive if measurements down to a few nanoseconds are to be made. For the fast Cerenkov work, an instrument with better dynamic range than an oscilloscope and with a time resolution sufficient to allow measurements limited only by system risetime of a few nanoseconds is needed. A 16/32 channel, 8 bit, fast transient digitizer was designed and built which runs at sample intervals down to approx. 1 nanosecond per channel.

Wild, N. R.↗

ROM-Based Plan-Position-Indicator Sweep Driver

Circuit produces PPI display on conventional X-Y oscilloscope. Circuit requires three inputs. First is once-per-scan pulse to synchronize display to north, relative heading, or another reference direction. Second is once-per-degree-of-rotation pulse to advance sweep rotation. Third input is normal sweep ramp. Duration of ramp corresponds to maximum displayed range. Changing ramp duration, while holding its peak amplitude constant, changes maximum displayed range. Conventional methods to accomplish this task use mechanically-driven deflection coils or mechanically-driven sine and cosine potentiometers, requiring mechanical preventive maintenance plus dedicated display indicator. New method displays radar sweep on any conventional storage oscilloscope.

Franke, J. M.↗

Shaft mode shape demonstration

The dynamic response of a rotating machine is directly influenced by its geometric configuration and all aspects of the rotor construction. These determine two significant parameters, mass distribution and stiffness, which yield a spectrum of natural frequencies and mode shapes. The mode shapes can be presented as snapshots of the characteristic amplitude/phase reponse patterns of the shaft, due to the major forcing function of unbalance, at different rotative speeds. To demonstrate the three shaft mode shapes of the rotor rig using the Shaft Mode Demonstrator and oscilloscopes. The synchronous (1X) amplitude and phase of the rotor vibration in the vertical direction from several points along the shaft is displayed on corresponding points of the demonstrator. Unfiltered vibration from vertical and horizontal probe pairs is displayed on the oscilloscopes in orbit format for a dynamic presentation of the mode shape.

Grissom, R.↗

High strain rate properties of unidirectional composites, part 1

Experimental methods were developed for testing and characterization of composite materials at strain rates ranging from quasi-static to over 500 s(sup -1). Three materials were characterized, two graphite/epoxies and a graphite/S-glass/epoxy. Properties were obtained by testing thin rings 10.16 cm (4 in.) in diameter, 2.54 cm (1 in.) wide, and six to eight plies thick under internal pressure. Unidirectional 0 degree, 90 degree, and 10 degree off-axis rings were tested to obtain longitudinal, transverse, and in-plane shear properties. In the dynamic tests internal pressure was applied explosively through a liquid and the pressure was measured with a calibrated steel ring. Strains in the calibration and specimen rings were recorded with a digital processing oscilloscope. The data were processed and the equation of motion solved numerically by the mini-computer attached to the oscilloscope. Results were obtained and plotted in the form of dynamic stress-strain curves. Longitudinal properties which are governed by the fibers do not vary much with strain rate with only a moderate (up to 20 percent) increase in modulus. Transverse modulus and strength increase sharply with strain rate reaching values up to three times the static values. The in-plane shear modulus and shear strength increase noticeably with strain rate by up to approximately 65 percent. In all cases ultimate strains do not vary significantly with strain rates.

Daniel, I. M.↗