Search NASA⌕ Search

SEARCH · Search NASA

Results for “oscilloscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of a frequency-dependent phase shift in chirped Raman lasers for atom gravimeters

Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. Here, we directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.

Xu, Yaoyao [Huazhong Univ. of Science and Technolo↗

The Recent Improvements of the SNS Extraction Kicker Power Supplies

A total of 14 extraction kickers., with one as the hot spare., are in service to extract protons out of the storage ring at the SNS. The jitter issue and the short lifetime of the switches were resolved after the thyratrons were replaced with solid state switches in 2018. This paper discusses the recent improvements. Two thyristor switches suffered overheating damage in separate incidents. One was due to the oil pump failure and the other was the result of a disconnected oil hose. An ultrasonic flow meter and a fiber optic temperature monitoring system have been installed for each extraction kicker power supply. The flow meter continuously monitors the entire tank oil flow. The temperature monitor detects the thyristor switch real-time temperatures in three locations. Fault thresholds are selected so that the thyristor switches are protected from overheating damage. Alarms are configured to alert staff to take actions before faults occur. In addition., the cause of an intermittent misfire issue was identified, and the solution was implemented. Lastly., a future oscilloscope upgrade and an oil level sensor are discussed.

Tan, Yugang↗

Ultrafast UV AlGaN Metal–Semiconductor–Metal Photodetector With a Response Time Below 25 ps

Here, aluminum-gallium-nitride photodetectors were successfully fabricated with micrometer-scale metal–semiconductor–metal structures and tested with ultrafast, UV laser pulses. The measurements were performed with single-shot oscilloscopes. Pulse-broadening effects caused by the measurement system were systematically evaluated and reduced to resolve the intrinsic response time of the detector. The best-performing devices showed a response time of below 25 ps and dark currents below 20 pA. The devices showed linear response with the bias voltage and the laser energy

42 ENGINEERING↗

Demonstration of Spectral Selectivity of Efficient and Ultrafast GaN/AlGaN-Based Metal–Semiconductor–Metal Ultraviolet Photodiodes

Efficient and ultrafast (aluminum)-gallium-nitride-based metal-semiconductor-metal (Al x )Ga 1–x N ultraviolet photodiodes were implemented to investigate the spectral properties of GaN/AlGaN-based photodetectors. Al composition of the GaN templates were varied from 0-% to 30% to demonstrate the impact of Al mole fraction on the cutoff wavelength of these UV photodiodes. Asymmetric metal contact electrodes were fabricated to optimize the external quantum efficiency without compromising their ultrafast photoresponse. Here, the best performing devices exhibited a peak response of 4 V and an oscilloscope limited temporal pulse width of 61 ps at a 20-V bias with a peak spectral responsivity of 36.5 mA/W at 280 nm.

42 ENGINEERING↗

Real-Time High-Accuracy Digital Wireless Time, Frequency, and Phase Calibration for Coherent Distributed Antenna Arrays

his work presents a fully-digital high-accuracy real-time calibration procedure for frequency and time alignment of open-loop wirelessly coordinated coherent distributed antenna array (CDA) modems, enabling radio frequency (RF) phase coherence of spatially separated commercial off-the-shelf (COTS) software-defined radios (SDRs) without cables or external references such as the global navigation satellite system (GNSS). Building on previous work using high-accuracy spectrally-sparse time of arrival (ToA) waveforms and a multistep ToA refinement process, a high-accuracy two-way time transfer (TWTT)-based time–frequency coordination approach is demonstrated. Due to the two-way nature of the high-accuracy TWTT approach, the time and frequency estimates are Doppler and multipath tolerant, so long as the channel is reciprocal over the synchronization epoch. This technique is experimentally verified using COTS SDRs in a lab environment in static and dynamic scenarios and with significant multipath scatterers. Time, frequency, and phase stability were evaluated by beamforming over coaxial cables to an oscilloscope which achieved time and phase precisions of ~60– 70 ps , with median coherent gains above 99% using optimized coordination parameters, and a beamforming frequency root-mean-square error (RMSE) of 3.73 ppb in a dynamic scenario. Finally, experiments were conducted to compare the performance of this technique with previous works using an analog continuous-wave two-tone (CWTT) frequency reference technique in both static and dynamic settings.

Clock synchronization↗

Advances in High Resolution Ultrafast Scintillators for Fast timing Applications

Scintillation detectors exhibiting high spatial resolution and fast timing capabilities are of vital importance for synchrotron sources. These detectors may be exposed to a variety of X-ray energies (up to 140 keV) and used in high frame rate applications. Here, we describe the advances in the development of thin-film LuI3:Ce scintillators for higher energy X-ray imaging, with fast timing and high spatial resolution. When grown in a single crystalline form, these scintillators are bright, producing 115 000 photons/MeV. However, to achieve high spatial resolution, these scintillators are grown in thin-film form with a microcolumnar structure, controllable to column diameters of <1-30 mu m. Thus, a much thicker scintillator layer (10 mu m-3 mm or higher) may be grown, providing superior X-ray absorption while achieving high resolutions of 50 mu m or better, at the cost of reduced light yield. To study the timing characteristics of the scintillator, time-resolved X-ray excited optical luminescence (TR-XEOL) was performed on two different sets of three samples of LuI3 at the 1-BM beamline of the Advanced Photon Source at Argonne National Laboratory. Besides, we report timing measurements obtained using a photomultiplier tube (PMT) and oscilloscope at Radiation Monitoring Devices (RMD) Inc. Using the TR-XEOL, we determined the decay constants of LuI3 as a function of Ce doping, recording a fast decay component as low as 3.6 ns (39%), one of the fastest values recorded in inorganic scintillators. This fast decay opens up numerous novel applications, where ultrahigh frame rates are important using synchrotron X-rays. This article will discuss fabrication, characterization, and potential applications for this novel scintillator.

fast timing↗

Longitudinal Emittance Measurements at PIP2IT

The PIP-II particle accelerator is a new upgrade to the Fermilab accelerator complex, featuring an 800-MeV H⁻ superconducting linear accelerator that will inject the beam into the present Fermilab Booster. A test accelerator known as PIP-II Injector Test (PIP2IT) has been built to validate the concept of the front-end of PIP-II. One of the paramount challenges of PIP2IT was to demonstrate a low longitudinal emittance at the end of the front end. Having a low longitudinal emittance is crucial in order to ensure the stability of the beam in the accelerator. We present a longitudinal emittance calculation at 14.3 MeV at the SSR1-8 cavity in the High Energy Transport line (HEBT). The signal is collected by a Fast Faraday Cup (FFC) at the end of HEBT and recorded by a high-bandwidth oscilloscope.

43 PARTICLE ACCELERATORS↗

Bunch Extinction Measurements at PIP-II Injector Test Facility

The PIP2 particle accelerator is a new upgrade to the Fermilab accelerator complex, featuring an 800-MeV H-superconducting linear accelerator that will inject the beam into the present Fermilab Booster. A test accelerator known as PIP-II Injector Test (PIP2IT) has been built to validate the concept of the front-end of such a machine. One of the paramount challenges of PIP2IT was to validate the bunch by bunch chopping system in the Medium Energy Beam Transport (MEBT). This paper aims to present the direct extinction measurements at PIP2IT and their analysis. These measurements have been taken by two Resistive Wall Current Monitors (RWCM) and recorded by a high bandwidth oscilloscope.

43 PARTICLE ACCELERATORS↗

Observation of Polarization-Dependent Changes in Higher-Order Mode Responses as a Function of Transverse Beam Position in Tesla-Type Cavities at FAST

Higher-order modes (HOMs) in superconducting rf cavities present problems for an electron bunch traversing the cavity in the form of long-range wakefields from previous bunches. These may dilute the emittance of the macropulse average, especially with low emittance beams at facilities such as the European X-ray Free-electron Laser (XFEL) and the upgraded Linac Coherent Light Source (LCLS-II). Here we present observations of HOMs driven by the beam at the Fermilab Accelerator Science and Technology (FAST) facility. The FAST facility features two independent TESLA-type cavities (CC1 and CC2) after a photocathode rf gun followed by an 8-cavity cryomodule. The HOM signals were acquired from cavities using bandpass filters of 1.75 ± 0.15 GHz, 2.5 ± 0.2 GHz, and 3.25 ± 0.2 GHz and recorded using an 8-GHz, 20 GSa/s oscilloscope. The frequency resolution obtained is sufficient to separate polarization components of many of the HOMs. These HOM signals were captured from CC1 and cavities 1 and 8 of the cryomodule for various initial trajectories through the cavities, and we observe correlations between trajectory, HOM signals, and which polarization component of a mode is affected.

Thurman-Keup, Randy Michael↗

Survey of the Worldwide Supply Chain of Commodities Needed for a Quantum Technology Program

Quantum Information Science (QIS) is an emerging technology being pursued by fundamental science research groups worldwide, as well as commercial companies and government programs. There are a variety of QIS disciplines, including quantum computing, quantum sensing and quantum encryption. Some of the commodities needed for a robust quantum laboratory are particular to quantum phenomenon, but in general the equipment needed is similar to that needed for a typical high - technology lab (e.g. oscilloscopes, lasers, vacuum chambers, etc.). This study focuses on identifying commodities manufactured worldwide that would be needed for a robust quantum lab. The authors' own knowledge of needed equipment and primary vendors was used as a starting point, follow ed by extensive internet searching and utilization of buyer's guides to create a large spreadsheet of most of the components needed, the company offering the components, and country of manufacture. With this extensive spreadsheet, stakeholders can identify commodities that would be needed for a quantum lab oratory and potentially identify market choke points.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Laboratory Instrument Software Controlled Spread Spectrum Time Domain Reflectometry for Electrical Cable Testing

This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Extracting LANSCE Macrobunch Charge from WNR Fast Pickoff [Slides]

Over several days around December 18, 2023, high-charge minipulses and macropulses were sent to Target 2, also known as the Blue Room. This report presents the calibration of a stripline-type current monitor known as the Fast Pickoff, and subsequent charge data for many of these shots. This effort utilized a fast oscilloscope, a nearby Bergoz current monitor, and some data-reduction techniques.

43 PARTICLE ACCELERATORS↗

ESIAS Pseudocode

The Explosive Shock Image Analysis System (ESAIS) is designed to provide a semiautomated quantitative analysis of fast-frame imagery taken during the detonation of high explosive (HE) rate sticks. ESIAS does this by assisting the user in identifying the HE stick geometry on the image (i.e., sides of the undetonated HE stick, detonation front, an axial reference point to assist in the inter-comparison of images); scaling the images based on the known diameter of the undetonated HE stick; identifying the profiles of various surfaces resulting from the detonation process such as the shock wave and product gases or the outer pipe surface; calculating the detonation speed of the HE by tracking the distance it travels between two images with a known time lapse between the images; and determining the slit velocities resulting from the detonation. ESIAS will also import scope traces from oscilloscopes and assist in identifying the time of arrival of significant peaks.

97 MATHEMATICS AND COMPUTING↗

2024 Milestone Report: Site 300 mPDV Optical Fiducials

In the early 2000s Photon Doppler Velocimetry (PDV) replaced the Fabry-Perot many beam system1 and has since become ubiquitous across dynamic experimental platforms to measure velocity and event times such as shock breakout, key variables for high pressure physics research. The advent of optically multiplexed oscilloscope channels to create multiplexed PDV (mPDV) increased portability and reduced price per data point. However, these advantages came with the cost of additional fielding complexity and thermally induced timing drift, which directly affects the ability to use PDV for high precision time measurement. Controlling the temperature or incorporating optical fiducials allows researchers to characterize, reduce, and correct this thermal drift in analysis. Our implemented optical fiducial or “timing marker” allows us to reduce thermal drift uncertainty from the 10s of nanoseconds down to the 100s of picoseconds with minimal added complexity to existing systems. The implementation of this timing marker normalizes uncertainty across optical delays, brings our facility cross timing into the sub nanosecond regime and lets us identify/study anomalies in our data. This improvement increases experiment reliability and quality enabling a new class of high precision experiments at S300.

42 ENGINEERING↗

Sound Speeds of Solids from Ultrasonic Pulse Receiver Measurements

A common method of determining elastic material properties is utilizing an ultrasonic pulse receiver. This is a non-destructive test (NDT) causing no plastic deformation of the material. It requires a pulse generator, oscilloscope, and two transducers to measure the sound velocity of a material. Both longitudinal and shear sound velocities may be obtained by utilizing the appropriate transducer. Acoustic nondestructive testing methods are often used in manufacturing certification processes and for material defect detection in industry. These methods can also be utilized to directly measure the elastic moduli of a material without damaging the material. Overall, it is a low-cost experiment with minimal preparation, and is easy to use.

36 MATERIALS SCIENCE↗

Current-Regulated Arc Modulator Optimization

n this study, the performance of a current-regulated arc modulator was investigated with a focus on its role in initiating and sustaining plasma discharge within the Magnetron Body of the LINAC system. The analysis centered on how switching components, circuit topology, and feedback loop architecture influence critical factors such as energy efficiency, discharge stability, and long-term plasma containment. Particular attention was given to variations in pulse termination behavior, as observed through oscilloscope traces, which revealed inconsistencies affecting the duty factor and cathode temperature. These fluctuations have downstream effects on the cesium-coated cathode surface, thereby impacting H⁻ ion production and beam reliability. Simulation-based testing in LTspice was used to evaluate noise suppression techniques and arc current regulation schemes, revealing how optimized snubber networks, improved pulse shaping, and feedback stability can mitigate modulator-induced noise. The results ide

Campos, Nathan↗

How Do You Hear a Quantum Computer Whisper?

Quantum transduction is the process of upconverting microwave quantum signals into optical signals to develop quantum networks through optical fibers outside the dilution refrigerator, enabling connections between quantum technologies on the quantum internet. In this project, upconversion is achieved by directing an optical laser and the microwave quantum signal into an electro-optic bulk crystal. The crystal is housed within a Superconducting Radio Frequency (SRF) cavity designed to maximize the overlap between the microwave field and the crystal volume. In the presence of microwaves, the refractive index of the crystal changes through the Pockels effect. This change in refractive index modifies the propagation of the optical field within the crystal, allowing the quantum information carried by the microwave field to be transferred to the optical field. This study focuses on coupling laser light from suspended waveguide chips into the whispering-gallery modes (WGMs) of the crystal to enable transduction. The coupling efficiency between the optical field in the suspended waveguide and the WGM depends on the position of the laser spot on the crystal. To address this challenge, a feedback-based algorithm is being developed to fine-tune the waveguide position so that the optical signal is coupled efficiently into the crystal. After passing through the crystal, the optical signal is detected by a photodiode connected to an oscilloscope. The algorithm evaluates the coupling quality and iteratively adjusts the waveguide position to maximize coupling efficiency. The expected outcome is an automated waveguide alignment method that improves optical coupling and enables more efficient microwave-to-optical quantum transduction.

Karanastasis, Mihael [Fermilab]↗

Understanding the temperature and humidity dependence of the SiPM characteristics

A miniature version of the ICAL experiment at the India-based Neutrino Observatory, the mini-ICALis in operation at the IICHEP, Madurai. The commissioning work of a Cosmic Muon Veto detector (CMVD)on top of the mini-ICAL is continued using extruded plastic scintillators with embeddedWLS fibers and the SiPM as a photo-transducer. The CMVD is being built to study thefeasibility of a cosmic muon veto for a shallow-depth neutrino experiment. The SiPM is calibratedusing an ultrafast LED driver andthe same calibration techniques will be used during the data taking period with a simplified LED in thesame readout PCB. An experimental setup wasdesigned to characterise the SiPMs in a temperature controlled environment. The readout electronicsinvolves trans-impedance amplifiers and a voltage followers of combined gain 1.24 mV/$\mu$A and adigital storage oscilloscope for the data collection with a minimal distortion of SiPM signal.Various characteristics of the Hamamatsu SiPM (S13360-2050VE), e.g. signal shape, optically correlatedand uncorrelated noise, recovery time etc were studied as a function of $V_{ov}$, number of photoelectrons,the ambient temperature and the humidity. This paper will cover the details of those results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗