SEARCH · Search NASA
Results for “overvoltage”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Assessment of Selected CERES Electronic Component Survivability under Simulated Overvoltage Conditions
In August, 1998 a Clouds and the Earth's Radiant Energy System (CERES) instrument telemetry housekeeping parameter generated a yellow warning message that indicated an on-board + 15V Data Acquisition Assembly (DAA) power converter deregulation anomaly. An exhaustive investigation was undertaken to understand this anomaly and the long-term consequences which have severely reduced CERES operations on the Tropical Rainfall Measuring Mission (TRMM) spacecraft. Among investigations performed were ground tests that approximated the on-board electronic circuitry using a small quantity of flight identical components exposed to maximum spacecraft bus over-voltage conditions. These components include monolithic integrated microcircuits that perform analog signal conditioning on instrument sensor signals and an analog- to-digital converter (ADC) for the entire DAA. All microcircuit packages have either a bipolar silicon design with internal current limiting protections or have a complementary metal oxide semiconductor (CMOS) design with bias protections. Ground tests that have been running for approximately 8 months have indicated that these components are capable of withstanding as much as twice their input supply voltage ratings without noticeable performance degradation. These data provide CERES operators with confidence of being able to continue science operations over the remaining life of the TRMM mission. This paper will discuss this anomaly and some possible causes, a simulator of affected electronics, test results, prognosis for future CERES operations, and conclusions.
Switching Modes for Reduction of Peak Voltage Transients in GaN-Based Three Level ANPC Inverter
The switching pole voltage can transition between P,0, and N states in a three-level active neutral point clamped (ANPC) inverter. State transitions between 0-P and 0-N can be realized with different switching modes. Three switching modes- Short 1 , Short 2 , and Full are studied considering the effect of capacitive current paths. The role of clamping and inner switch on/off conditions is determined using simplified equivalent circuit models. Short 2 with clamping switch off is beneficial for turn-on overvoltage suppression but results in high turn-off overvoltage. Full mode with a parallel current sharing path is effective for turn-off overvoltage suppression but leads to high turn-on overvoltage. Hence, a Modified Full mode is proposed to achieve the simultaneous objective of overvoltage suppression at both turn-on and turn-off transient during high load currents. This benefits 3L ANPC operation at a low power factor with a high load current at fundamental voltage zero crossing points. Here, a 650V GaN-based three-level ANPC inverter prototype is designed and used to evaluate the switching modes and overvoltage suppression strategies through double pulse tests and continuous operation.
Electrode kinetics of a water vapor electrolysis cell
The anodic electrochemical behavior of the water vapor electrolysis cell was investigated. A theoretical review of various aspects of cell overvoltage is presented with special emphasis on concentration overvoltage and activation overvoltage. Other sources of overvoltage are described. The experimental apparatus controlled and measured anode potential and cell current. Potentials between 1.10 and 2.60 V (vs NHE) and currents between 0.1 and 3000 mA were investigated. Different behavior was observed between the standard cell and the free electrolyte cell. The free electrolyte cell followed typical Tafel behavior (i.e. activation overvoltage) with Tafel slopes of about 0.15, and the exchange current densities of 10 to the minus 9th power A/sq cm, both in good agreement with literature values. The standard cell exhibitied this same Tafel behavior at lower current densities but deviated toward lower than expected current densities at higher potentials. This behavior and other results were examined to determine their origin.
The Corrosion of Magnesium and of the Magnesium Aluminum Alloys Containing Manganese
The extensive use of magnesium and its alloys in aircraft has been seriously handicapped by the uncertainties surrounding their resistance to corrosion. This problem has been given intense study by the American Magnesium Corporation and at the request of the Subcommittee on Materials for Aircraft of the National Advisory Committee for Aeronautics this report was prepared on the corrosion of magnesium. The tentative conclusions drawn from the experimental facts of this investigation are as follows: the overvoltage of pure magnesium is quite high. On immersion in salt water the metal corrodes with the liberation of hydrogen until the film of corrosion product lowers the potential to a critical value. When the potential reaches this value it no longer exceeds the theoretical hydrogen potential plus the overvoltage of the metal. Rapid corrosion consequently ceases. When aluminum is added, especially when in large amounts, the overvoltage is decreased and hydrogen plates out at a much lower potential than with pure magnesium. The addition of small amount of manganese raises the overvoltage back to practically that of pure metal, and the film is again negative.
Fairness-Aware Distributed Energy Coordination for Voltage Regulation in Power Distribution Systems
The accelerating deployment of solar photovoltaics into low-voltage distribution networks can cause reverse power flow and overvoltage problems. However, if coordinated properly, the real and reactive power flexibility of these resources enables distribution operators to manage their networks more efficiently. Existing literature is rich in droop-based control (Volt-Watt and Volt-VAr) and optimization-based distributed energy coordination for four-quadrant control of photovoltaics to prevent overvoltage issues. While optimal coordination can effectively mitigate overvoltage, it tends to treat resources at sensitive parts of the grid unfairly. Here, to address this concern, we propose a distributed optimal power flow formulation that incorporates fairness in curtailing photovoltaic generation and utilizes the reactive power capability of smart inverters. The proposed distributed formulation allows for scalable resource aggregation that can be leveraged to achieve fairness within a certain segment of the grid and/or fairness across the entire network. Fair curtailment of photovoltaic systems is demonstrated with aggregation at each of two layers in a distribution network: 1) area-level fairness and 2) feeder-level fairness. To explore the trade-off between fairness and optimal utilization, the fairness-aware control actions are compared against the performance of a centralized controller that aims to maximize the aggregate PV generation without incorporating fairness. Simulation results show that introducing area-level fairness increased curtailment by 0.0101 percentage points and feeder-level fairness increased curtailment by 0.0458 percentage points compared to a fairness-agnostic control.
Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture
Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.
A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems
The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.
Enabling Fairness in Distributed PV Curtailment for Voltage Regulation: A Comparative Analysis
The growing adoption of photovoltaic systems in power distribution networks has yielded numerous advantages, but it has also introduced challenges, particularly in managing overvoltage issues. Uncoordinated photovoltaic integration can lead to voltage rise beyond acceptable levels. Curtailing active power is an effective method for addressing overvoltage issues in power distribution systems. Nevertheless, it is essential to distribute the curtailment fairly among the resources to maintain fairness and achieve a well-balanced utilization of renewable energy. This paper presents a comparative study of different fairness schemes for active power curtailment in photovoltaic integration systems. Three different curtailment methods are selected for demonstration: i) proportional, ii) egalitarian, and iii) financial. The study involves evaluating the curtailment schemes based on their ability to distribute the curtailed power among the photovoltaic systems in a justifiable manner, focusing on their formulation and distributed solution. A detailed performance comparison is carried out to highlight the cost of catering for fairness schemes in photovoltaic curtailment using relevant metrics, where simulations are carried out using a modified IEEE 123-bus test case.
A Novel Model of Thyristor in Reverse Recovery Process for Current Interruption Test of HVDC Circuit Breakers
The high voltage thyristor is widely used in high voltage DC (HVDC) grids due to its large current capability. Recently, the high voltage thyristor is implemented to produce a high current in the HVDC circuit breaker (CB) testing process. Unfortunately, the reverse recovery process (RRP) of a thyristor could induce significant turn-off overvoltage and power losses, jeopardizing the safety of the devices. The existing models of a thyristor cannot describe such hard-switching transient accurately. Therefore, this paper divides this process into four stages based on the physical mechanism and proposes a novel cosine exponential (CE), simulating the voltage and current of the thyristor with analytical equations, which are derived from the equivalent circuit. Moreover, the extraction procedure of the proposed model is illustrated in this paper. Finally, we develop an HVDC CB test platform to validate the proposed model. Experimental results show that the proposed CE model can accurately predict the overvoltage with a relative error of less than 8% at various current varying rates.
( Invited ) Ruggedness of SiC and GaN Power Transistors in Switching Based Tests
Currently, a spectrum of reliability tests are being performed by both device manufacturers and end users. Many of these qualification tests are operated within the device safe-operating-area (SOA), however, the devices often undergo dynamic events in many converter applications that can exceed the SOA boundaries. This paper presents our recent work on quantifying the out-of-SOA robustness of GaN power high-electron-mobility transistors (HEMTs) and SiC power MOSFETs by switching based tests. The unclamped inductive switching stresses are applied to p-gate GaN HEMTs to evaluate their surge-energy and overvoltage robustness. The continuous, hard-switching, turn-off stresses are applied to SiC MOSFETs to evaluate their overvoltage switching robustness. As a result, both experiments demonstrate the robustness of SiC and GaN devices under out-of-SOA switching events, and the physics of degradation and failure are understood.
Early-Time (E1) High-Altitude Electromagnetic Pulse Effects on Trip Coils
A High-Altitude Electromagnetic Pulse (HEMP) is a potential threat to the power grid. HEMP can couple to transmission lines and cables, causing significant overvoltages which can be harmful to line connected equipment. The effects of overvoltages on various types of power systems components need to be understood. HEMP effects on trip coils were tested and presented in this report. A high voltage pulser was built to replicate the induced voltage waveform from a HEMP. The pulser was used to test breaker trip coils with increasing pulse magnitudes ranging from 20 kV to 80 kV. The State-of-Health of each trip coils was measured via mechanical operation and impedance measurements before and after each insult to identify any damage or degradation to the trip coils. Dielectric breakdown was observed at the conductor leads during testing, causing the HEMP insult to be diverted to the grounded casing. However, the dielectric breakdown did not cause interference with regular device operation.
Surge protection with automatic reset
Circuit turns power off automatically when surge occurs and restores power when voltage returns to normal. Transmitters and other equipment are protected in electrically noisy environments; however, if three transient overvoltages (or continuous overvoltage) are sensed within 3.2 seconds, circuit turns power supply off permanently since serious failure may have occurred.
DC isolation and protection system and circuit
A precision analog electronic circuit that is capable of sending accurate signals to an external device that has hostile electric characteristics, including the presence of very large common mode voltages. The circuit is also capable of surviving applications of normal mode overvoltages of up to 120 VAC/VDC for unlimited periods of time without damage or degradation. First, the circuit isolates the DC signal output from the computer. Means are then provided for amplifying the isolated DC signal. Further means are provided for stabilizing and protecting the isolating and amplifying means, and the isolated and amplified DC signal which is output to the external device, against overvoltages and overcurrents.
Protection schemes used in North American microgrids
This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.
Non‐Linear Kinetics of The Lithium Metal Anode on Li 6 PS 5 Cl at High Current Density: Dendrite Growth and the Role of Lithium Microstructure on Creep
Abstract Interfacial instability, viz., pore formation in the lithium metal anode (LMA) during discharge leading to high impedance, current focusing induced solid–electrolyte (SE) fracture during charging, and formation/behaviour of the solid–electrolyte interphase (SEI), at the anode, is one of the major hurdles in the development of solid‐state batteries (SSBs). Also, understanding cell polarization behaviour at high current density is critical to achieving the goal of fast‐charging battery and electric vehicle. Herein, via in situ electrochemical scanning electron microscopy (SEM) measurements, performed with freshly deposited lithium microelectrodes on transgranularly fractured fresh Li6PS5Cl (LPSCl), the LiǀLPSCl interface kinetics are investigated beyond the linear regime. Even at relatively small overvoltages of a few mV, the LiǀLPSCl interface shows non‐linear kinetics. The interface kinetics possibly involve multiple rate‐limiting processes, i.e., ion transport across the SEI and SE|SEI interfaces, as well as charge transfer across the LiǀSEI interface. The total polarization resistance R P of the microelectrode interface is determined to be ≈ 0.8 Ω cm 2 . It is further shown that the nanocrystalline lithium microstructure can lead to a stable LiǀSE interface via Coble creep along with uniform stripping. Also, spatially resolved lithium deposition, i.e., at grain surface flaws, grain boundaries, and flaw‐free surfaces, indicates exceptionally high mechanical endurance of flaw‐free surfaces toward cathodic load (>150 mA cm −2 ). This highlights the prominent role of surface defects in dendrite growth.
Quantitative Decoupling of Oxygen-Redox and Manganese-Redox Voltage Hysteresis in a Cation-Disordered Rock Salt Cathode
Pronounced voltage hysteresis in Li-excess cathode materials is commonly thought to be associated with oxygen redox. However, these materials often possess overlapping oxygen and transition-metal redox, whose contributions to hysteresis between charge and discharge are challenging to distinguish. In this work, a two-step aqueous redox titration is developed with the aid of mass spectrometry (MS) to quantify oxidized lattice oxygen and Mn 3+/4+ redox in a representative Li-excess cation-disordered rock salt—Li 1.2 Mn 0.4 Ti 0.4 O 2 (LMTO). Two MS-countable gas molecules evolve from two separate titrant-analyte reactions, thereby allowing Mn and O redox capacities to be decoupled. The decoupled O and Mn redox coulombic efficiencies are close to 100% for the LMTO cathode, indicating high charge-compensation reversibility. As incremental Mn and O redox capacities are quantitatively decoupled, each redox voltage hysteresis is further evaluated. Overall, LMTO voltage hysteresis arises not only from an intrinsic charge-discharge voltage mismatch related to O redox, but also from asymmetric Mn-redox overvoltages. The results reveal that O and Mn redox both contribute substantially to voltage hysteresis. In conclusion, this work further shows the potential of designing new analytical workflows to experimentally quantify key properties, even in a disordered material having complex local coordination environments.
Heat Transfer Fluids as Co‐Diluents in Localized High‐Concentration Electrolytes for High‐Rate Lithium Metal Batteries With Enhanced Safety
Localized high-concentration electrolytes (LHCEs) have been identified as promising electrolyte formulations for lithium metal batteries, due to their effective interphase formation and promotion of compact Li deposition, yet their practical implementation is often limited by reduced ion transport kinetics. In this study, two industrially established fluorinated ethers are identified for the first time in battery research as effective co-diluents as they combine a broad electrochemical stability window with a low viscosity and intrinsic non-flammability. Incorporating these components, commonly used as heat transfer fluids, yields safer, less flammable electrolyte formulations with enhanced ion mobilities. In particular, the ternary co-diluent formulation shows improved ion mobility by reducing the electrolyte's viscosity while limiting excessive ion clustering. Based on the improved electrolyte transport kinetics, lower overvoltages and higher Coulombic efficiencies at current densities ≥ 1 mA cm −2 are achieved with the ternary co-diluent blend, resulting in markedly extended cycle life in an application-oriented zero-excess pouch cell compared with the baseline system. Complementary electrochemical and ex situ analysis of harvested electrodes at moderate current densities reveals no discernible differences in interphase morphology and composition, suggesting enhanced ion mobility as the primary cause of the improved high-rate performance.