Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Main characteristics of the COMET/COMRADE experiments

Both the COMET (Collection en Orbite de Matiere Extra Terrestre) and the COMRADE (Collection of Micrometeorites, Residue and Debris Ejecta) programs are developed to the collection and analysis of the particles of various origins orbiting around the Earth at low altitudes (between approx. 300 and approx. 500 km). The COMET experiment is more specifically designed to be flown for a short period of time (a few days), in concordance with a meteor stream crossing the Earth. Thus, it results in a considerable enrichment in the collection of grains related to a given comet. The COMRADE experiment has been selected as a proposal for long-duration flights (a few months), in order to gain information on all sizes of particles present on low Earth orbits, including submicrometer grains. It has been accepted by ESA authorities for use on the EURECA 2 platform. The objectives of these studies are multiple. The use of passive detectors gives access to the chemical and isotopical properties of the grains in the micrometer size range, by analyzing either the particle remnant mixed with the target material, or the intact particle captured in a specific low-density material. The particle remnants of the micrometer-sized extraterrestrial grains, having impacted on purposely designed metallic collectors, are identified for complete and detailed chemical, isotopic, and organic analysis, thereby determining grain composition as well as the existence of organic and inorganic molecules, to be related with the possible cometary origin of the grains. Micrometer/submicrometer dust grains are also captured in a manner that ensures minimal particle degradation. The captured intact particles are returned to Earth for complete and detailed chemical, isotopic, spectral, mineralogical, and organic analysis.

Borg, J.↗

A study of the radiation environment on board the space shuttle flight STS-57

A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on space shuttle flight STS-57 was conducted. The shuttle flew in a nearly circular orbit of 28.5 deg inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTD's) and thermoluminescent detectors (TLD's), and Russian nuclear emulsions, PNTD's, and TLD's. All the detector systems were shielded by the same shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micron and 200 keV/micron. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than TLD's, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLD's to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.

Badhwar, G. D.↗

Linear Energy Transfer (LET) spectra of cosmic radiation in low Earth orbit

Integral linear energy transfer (LET) spectra of cosmic radiation (CR) particles were measured on five Cosmos series spacecraft in low Earth orbit (LEO). Particular emphasis is placed on results of the Cosmos 1887 biosatellite which carried a set of joint U.S.S.R.-U.S.A. radiation experiments involving passive detectors that included thermoluminescent detectors (TLD's), plastic nuclear track detectors (PNTD's), fission foils, nuclear photo-emulsions, etc. which were located both inside and outside the spacecraft. Measured LET spectra are compared with those theoretically calculated. Results show that there is some dependence of LET spectra on orbital parameters. The results are used to estimate the CR quality factor (QF) for the COSMOS 1887 mission.

Parnell, T. A.↗

Characterization of the Radiation Shielding Properties of U.S. and Russian Extravehicular Activity Suits

Reported herein are results from the Eril Research, Inc. (ERI) participation in the JSC-sponsored study characterizing the radiation shielding properties of the two types of space suit that astronauts are wearing during the EVA on-orbit assembly of ISS. Measurements using passive detectors were carried out to assess the shielding properties of the U.S. EMU Suit and the Russian Orlan-M suit during irradiations of the suits and a tissue-equivalent phantom to monoenergetic proton and electron beams at LLUMC. During irradiations of 6 MeV electrons and 60 MeV protons, absorbed dose as a function of depth was measured using TLDs exposed behind swatches of the two suit materials and inside the two EVA helmets. Considerable reduction in electron dose was measured behind all suit materials in exposures to 6 MeV electrons. Slowing of the proton beam in the suit materials led to an increase in dose measured in exposures to 60 MeV protons. During 232 MeV proton irradiations, measurements were made with TLDs and CR-39 PNTDs at five organ locations inside a tissue-equivalent phantom, exposed both with and without the two EVA suits. The EVA helmets produce a 13% to 27% reduction in total dose and a 0% to 25% reduction in dose equivalent when compared to measurements made in the phantom head alone. Differences in dose and dose equivalent between the suit and non-suit irradiations for the lower portions of the two EVA suits tended to be smaller. Proton-induced target fragmentation was found to be a significant source of increased dose equivalent, especially within the two EVA helmets, and average quality factor inside the EMU and Orlan-M helmets was 2% to 14% greater than that measured in the bare phantom head.

Benton, E. R.↗

Dosimetric results from the Mir orbital station

The Mir Orbital Station provided a unique platform on which to carry out a variety of space radiation dosimetry measurements. A number of experiments were conducted using a combination of passive detectors on the interior of the Mir during 1996-97. Thermoluminescent detectors were used to measure absorbed dose. CR-39 plastic nuclear track detectors were used to measure the LET spectra > or =5 keV.microm(-1). Results from TLDs and CR-39 PNTDs were combined to determine total dose and dose equivalent. Mean dose rate was found to decrease while mean dose equivalent rate and average quality factor increased with increasing shielding. Secondary particles from proton-induced target fragmentation interactions, not primary HZE particles, were found to be the largest contributor to the LET spectrum above 100 keV.microm(-1). During the 1997 measurements, mean quality factor was found to vary from 1.7 to 2.1 as a function of location within the Mir.

long duration↗

Secondary particle contribution to LET spectra on LDEF

Four experiments utilizing passive detectors (P0006, P0004, A0015, M0004) were flown on LDEF to study the radiation environment. These experiments have been summarized in a companion paper (Benton et al., 1996). One of the experimental goals was to measure LET spectra at different locations and shielding depths with plastic nuclear track detectors (PNTD). It was found that the LET spectra extended well above the LET cutoff imposed by the geomagnetic field on GCR particle penetration into LEO. The high LET particles detected were mostly short-range (range < 2000 m), indicating that they were secondaries produced locally within the PNTD. The presence of these high LET particle fluences is important for the determination of dose equivalent because of the high Quality Factors (Q) involved. A relatively small fraction of particle fluence can contribute a large fraction of dose equivalent. Short-range, inelastic secondary particles produced by trapped protons in the South Atlantic Anomaly (SAA) were found to be a major contributor to the LET spectra above 100 keV/micrometer. The LET spectra were found to extend beyond the approximately 137 keV/micrometer relativistic GCR Fe peak to over 1000 keV/micrometer. The high LET tail of the LET spectra was measured in CR-39 and polycarbonate PNTDs using different techniques. GCR made a relatively modest contribution to the LET spectra as compared to the contributions from short-range secondary particles and stopping protons. LET spectra intercomparisons were made between LDEF measurements and exposures to 154 MeV accelerated proton beams. The similarities support the role of nuclear interactions by trapped protons as the major source of secondary particles in the PNTDs. Also techniques were employed to reduce the range cutoff for detection of the short-range secondaries to approximately 1 micrometer, so that essentially all secondary particles were included in the LET spectra. This has allowed a more realistic assessment of secondary contribution to dose equivalent. Comparisons of measured and calculated LET spectra have been made that demonstrate the need for more accurate modeling of secondary particles in radiation transport codes. Comparisons include preliminary calculations in which attempts have been made to include secondary particles.

long duration↗

Measurement of differential proton spectra onboard the Space Shuttle using a thermoluminescent dosimetry system

An experimental technique that permits the extraction of orbit-averaged, differential energy spectra of trapped radiation belt protons using simple passive detectors is described. An inversion technique is used for the data analysis. The basic principle of the described system is measurement of the energy deposited in six thermoluminescent (TLD) detector assemblies behind various spherical absorbers. The technique has been applied to a detector assembly flown on four Shuttle flights. Although severe restraints were placed on the flight package, the differential energy spectra derived from these measurements are in good agreement with analytical results using a modified trapped proton environment model. The technique shows good promise for measuring the spectra in low inclination orbits where the flux of high energy galactic cosmic rays protons is small. Modifications to the detector assembly to improve the accuracy and to extend the range of the system to higher energies are suggested.

STS-51J Shuttle Project↗

Linear energy transfer (LET) spectra of cosmic radiation in low Earth orbit

Integral linear energy transfer (LET) spectra of cosmic radiation (CR) particles were measured on five Cosmos series spacecraft in low Earth orbit (LEO). Particular emphasis is placed on results of the Cosmos 1887 biosatellite which carried a set of joint U.S.S.R.-U.S.A. radiation experiments involving passive detectors that included thermoluminescent detectors (TLDs), plastic nuclear track detectors (PNTDs), fission foils, nuclear photo-emulsions, etc. which were located both inside and outside the spacecraft. Measured LET spectra are compared with those theoretically calculated. Results show that there is some dependence of LET spectra on orbital parameters. The results are used to estimate the CR quality factor (QF) for the Cosmos 1887 mission.

NASA Discipline Radiation Health↗

Improvements to the Ionizing Radiation Risk Assessment Program for NASA Astronauts

To perform dosimetry and risk assessment, NASA collects astronaut ionizing radiation exposure data from space flight, medical imaging and therapy, aviation training activities and prior occupational exposure histories. Career risk of exposure induced death (REID) from radiation is limited to 3 percent at a 95 percent confidence level. The Radiation Health Office at Johnson Space Center (JSC) is implementing a program to integrate the gathering, storage, analysis and reporting of astronaut ionizing radiation dose and risk data and records. This work has several motivations, including more efficient analyses and greater flexibility in testing and adopting new methods for evaluating risks. The foundation for these improvements is a set of software tools called the Astronaut Radiation Exposure Analysis System (AREAS). AREAS is a series of MATLAB(Registered TradeMark)-based dose and risk analysis modules that interface with an enterprise level SQL Server database by means of a secure web service. It communicates with other JSC medical and space weather databases to maintain data integrity and consistency across systems. AREAS is part of a larger NASA Space Medicine effort, the Mission Medical Integration Strategy, with the goal of collecting accurate, high-quality and detailed astronaut health data, and then securely, timely and reliably presenting it to medical support personnel. The modular approach to the AREAS design accommodates past, current, and future sources of data from active and passive detectors, space radiation transport algorithms, computational phantoms and cancer risk models. Revisions of the cancer risk model, new radiation detection equipment and improved anthropomorphic computational phantoms can be incorporated. Notable hardware updates include the Radiation Environment Monitor (which uses Medipix technology to report real-time, on-board dosimetry measurements), an updated Tissue-Equivalent Proportional Counter, and the Southwest Research Institute Radiation Assessment Detector. Also, the University of Florida hybrid phantoms, which are flexible in morphometry and positioning, are being explored as alternatives to the current NASA computational phantoms.

Semones, E. J.↗

Small Active Radiation Monitor

A device, named small active radiation monitor, allows on-orbit evaluations during periods of increased radiation, after extravehicular activities, or at predesignated times for crews on such long-duration space missions as on the International Space Station. It also permits direct evaluation of biological doses, a task now performed using a combination of measurements and potentially inaccurate simulations. Indeed the new monitor can measure a full array of radiation levels, from soft x-rays to hard galactic cosmic-ray particles. With refinement, it will benefit commercial (nuclear power-plant workers, airline pilots, medical technicians, physicians/dentists, and others) and military personnel as well as the astronauts for whom thermoluminescent dosimeters are inadequate. Civilian and military personnel have long since graduated from film badges to thermoluminescent dosimeters. Once used, most dosimeters must be returned to a central facility for processing, a step that can take days or even weeks. While this suffices for radiation workers for whom exposure levels are typically very low and of brief duration, it does not work for astronauts. Even in emergencies and using express mail, the results can often be delayed by as much as 24 hours. Electronic dosimeters, which are the size of electronic oral thermometers, and tattlers, small electronic dosimeters that sound an alarm when the dose/dose rate exceeds preset values, are also used but suffer disadvantages similar to those of thermoluminescent dosimeters. None of these devices fully answers the need of rapid monitoring during the space missions. Instead, radiation is monitored by passive detectors, which are read out after the missions. Unfortunately, these detectors measure only the absorbed dose and not the biologically relevant dose equivalent. The new monitor provides a real-time readout, a time history of radiation exposures (both absorbed dose and biologically relevant dose equivalent), and a count of the number of particles passing through a unit area. Better still, the monitor can be used anywhere.

Badhwar, Gautam D.↗

Final Report on Radiation Measurements Performed Inside of the BEAM Module

Measurements of the radiation environment inside of the Bigelow Expandable Activity Module (BEAM) have been made on a pseudo-continuous basis since June 6, 2016 using both passive and active instrumentation. Passive detectors yield a single cumulative dose value (or average daily dose) over the measurement period from deploy to return to ground. Active Radiation Environment Monitor (REM) sensors yield dose rate, Linear Energy Transfer (LET) spectra, and particle-specific dose, all on a 1-minute cadence. From the initial install in 2016 until early 2018, BEAM was an empty module. In 2018, further testing was approved and stowage began to be moved into BEAM. As a result, it was decided to stop measurements with RAM detectors to avoid potential difficulties with access after stowage was added. The REM sensors remained however in the original deploy locations.

radiation exposure↗

Surface Passivation of CdZnTe Detector by Hydrogen Peroxide Solution Etching

The spectral resolution of room temperature nuclear radiation detectors such as CdZnTe is usually limited by the presence of conducting surface species that increase the surface leakage current. Studies have shown that the leakage current can be reduced by proper surface preparation. In this study, we try to optimize the performance of CdZnTe detector by etching the detector with hydrogen peroxide solution as function of concentration and etching time. The passivation effect that hydrogen peroxide introduces have been investigated by current-voltage (I-V) measurement on both parallel strips and metal-semiconductor-metal configurations. The improvements on the spectral response of Fe-55 and 241Am due to hydrogen peroxide treatment are presented and discussed.

Hayes, M.↗

A Monolithic 2k x 2k LWIR HgCdTe Detector Array for Passively Cooled Space Missions

A 2K x 2K 10 µm cutoff HgCdTe array for background-limited space astronomy has been developed by Teledyne Imaging Sensors to specifications set by JPL, and demonstrated by University of Rochester at a focal plane temperature of 40K for the proposed JPL Near-Earth Object Camera (NEOCam) survey mission under the NASA Planetary Defense Coordination Office. We describe the detector performance for the first large format monolithic HgCdTe detector array tested, including the dark current, well depth, dark current vs. temperature, quantum efficiency, latent image performance, and read noise.

Pan, Jianmei↗

A Monolithic 2k x 2k LWIR HgCdTe Detector Array for Passively Cooled Space Missions

A 2K x 2K 10 µm cutoff HgCdTe array for background-limited space astronomy has been developed by Teledyne Imaging Sensors to specifications set by JPL, and demonstrated by University of Rochester at a focal plane temperature of 40K for the proposed JPL Near-Earth Object Camera (NEOCam) survey mission under the NASA Planetary Defense Coordination Office. We describe the detector performance for the first large format monolithic HgCdTe detector array tested, including the dark current, well depth, dark current vs. temperature, quantum efficiency, latent image performance, and read noise.

Pan, Jianmei↗

Detector Performance on Surface Passivation and its Long-Term Stability

Surface passivation is an ideal technique to prepare the surfaces of fabrication Cadmium Zinc Telluride (CZT) and related semiconductor devices such as Cadmium Zinc Tellurium Selenide (CZTS). Surface passivation techniques reduce the effects of aging in the detector [1]. Surface performance effects on material performance can result in fluctuations in energy resolution over time (such as periods of a year or more). The long-term stability of surface passivation with Potassium Hydroxide (KOH) was observed with measurement of 1) current (nano Amp) vs voltage (V) and 2) spectral response and energy resolution throughout the years. Three CZTS detector samples of M2, M3, and M4 were examined using a photomultiplier tube and voltage amplifier. The Bridgman technique is used to grow the CZTS used in this study.

Johnson, Kirsten [Morgan State Univ., Baltimore, M↗

Performance of an INTEGRAL spectrometer model

Model calculations for the INTEGRAL spectrometer (SPI) onboard the future INTErnational Gamma Ray Astrophysics Laboratory (INTEGAL) are presented, where the sensitivity for narrow lines is based on estimates of the background level and the detection efficiency. The instrumental background rates are explained as the sum of various components that depend on the cosmic ray intensity and the spectrometer characteristics, such as the mass distribution around the Ge detectors, the passive material, the characteristics of the detector system and the background reduction techniques. Extended background calculations were performed with Monte Carlo simulations and using semi-empirical and calculated neutron and proton cross sections. In order to improve the INTEGRAL spectrometer sensitivity, several designs and background reduction techniques were compared for an instrument with a fixed detector volume.

Jean, P.↗

Effect of Surface Passivation of CZTS Semiconductor Detector on Leakage Current

Cadmium Zinc Telluride Selenide (CdZnTeSe or CZTS)has shown high crystal quality for room-temperature gamma ray and X-ray detection applications compared to Cadmium Zinc Telluride (CdZnTe or CZT) [1,2]. Current applications of CZT include medical imaging, homeland security, and X-ray and gamma ray astronomy [3]. CZST has similar potential applications

Kangethe, Anthony [Morgan State Univ., Baltimore, ↗