Search NASA⌕ Search

SEARCH · Search NASA

Results for “payback period”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Better Climate Challenge Working Groups Non-Energy Benefits of Energy Projects-Improving Financial Payback

Energy efficiency is a key strategy recently identified by the United States Department of Energy as a pillar of industrial decarbonization. For manufacturing companies, improving energy efficiency will reduce money spent on energy utilities such as gas, electricity, and oil. Energy improvement projects also provide valuable benefits outside of simple operating cost reductions, such as reducing the carbon footprint, improving safety metrics and even enhancing quality and productivity. Unfortunately, energy efficiency projects have typically faced an adoption gap, even when they meet criteria such as payback period for capital projects. The inclusion and quantification of non-energy benefits (NEBs), also known as co-benefits, in the decision-making process for energy efficiency projects can improve the overall financial payback periods for those projects as well as potentially improve the company's key performance metrics aligned with business strategies. There are no readily available tools that facilitate this, however, and the most used tools for energy audits address NEBs in a perfunctory way if at all. We integrated research for finding and quantifying non-energy benefits of energy efficiency projects into a commonly recognized continuous improvement practice, the Define, Measure, Analyze, Improve and Control (DMAIC) Process. This process, along with software and supplemental materials, guides energy assessments to find and to quantify NEBs associated with energy conservation opportunities. Our aim is to deliver an easy to use and effective process and software tool and to maximize return on investment for energy efficiency projects as well as contribute to companies' strategic performance goals.

DMAIC↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

Long-term impact of electrification and retrofits of the U.S residential building in diverse locations

The U.S. buildings sector contributes 30% of operational carbon emissions, with residential buildings accounting for 56%. Reducing residential carbon emissions is crucial for achieving net-zero carbon goal. While many studies examine energy efficiency retrofit (EER) and electrification, few explore their long-term impacts across diverse climates and dynamic grid clean energy penetrations, as well as their economic effects on households. Here, this study proposes a method to assess how EER and electrification affect long-term decarbonization and economics across different climates, focusing on carbon emissions, energy burden (the percentage of household income spent on energy), and payback period in four locations: Tampa, San Diego, Denver, and Great Falls. The study also introduces the concept of implicit energy burden by considering investment costs. Results show that while electrification can reduce long-term emissions with increased clean energy penetration, it may not always achieve decarbonization due to mismatches between clean energy availability and demand. In cooling-dominant locations, electrification lowers energy burden and peak demand, but in heating-dominant locations, it increases energy burden to 8.24%, raises peak demand by 632.78%, and shifts it from summer to winter. After integrating investment costs, the implicit energy burden can reach 8.35% in cold climates. For already highly electrified buildings in Denver and Great Falls, the payback period of EER measures can be shortened by up to 48.98%. The study highlights a tradeoff between decarbonization and energy burden alleviation, showing that while EER measures can reduce the energy burden, they only achieve one-quarter of the carbon emission reduction of electrification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost-Benefit Analysis For Indonesia Building Sector: Whole-Building Cooling Solutions

The Net Zero World (NZW) Initiative Collaborative Work Program with the Government of Indonesia (GoI) includes technical assistance and investment mobilization facilitation to accelerate deployment of energy efficiency technologies and solutions for the building sector. A February 2023 U.S.–Indonesia Joint Workshop on Decarbonizing the Building Sector yielded a NZW Indonesia Building Decarbonization Working Group (NZW IBDWG) with four sub-working groups (SWG): SWG-A National Center, SWG-B Capacity Building, SWG-C Investment and Financing, and SWG-D Pilot Projects. Technical analysis of whole-building cooling solutions for tropical climates of Indonesia was conducted by SWG-A to quantify energy savings, carbon dioxide reductions, and comfort improvements offered by 12 passive or low-energy cooling strategies: ceiling fans with and without thermostat setbacks; cool roofs; cool walls; exterior awnings; exterior shades; interior shades; insulated roofs; insulated walls; low-e windows; solar window films; and natural ventilation. Leveraging the results from SWG-A, cost-benefit analysis (CBA) was conducted by SWG-C to assess the consumer and national costs and impacts associated with these 12 cooling solutions. The evaluation involved estimating life-cycle costs (LCC), payback period (PBP), net present values (NPV), annual electricity burden change for low-income households, and reduced national annual power-sector generation demand by 2030, 2040, 2050, and 2060. This evaluation can help guide Indonesia’s Just Energy Transition Partnership (JETP) investments in policies and programs to advance research, development, deployment, and commercial adoption (RDDCA) of efficient residential building sector cooling technologies and solutions in Indonesia. Four key energy conservation measures (ECM) have been identified to reduce air-conditioning (AC) energy demand in single-family housing in Indonesia: ceiling fan with temperature setback (to 28.1 °Celcius from 25 °C); insulated walls; insulated roof; and cool roof. This study found that low-income households with AC installations in Indonesia currently face a high energy cost burden of approximately 10%. However, by implementing a ceiling fan with temperature setback, this burden could decrease to 2.5% today and further reduce to 1.3% by the year 2060. The PBP for a ceiling fan with temperature setback is one year, indicating one of the lowest LCC and best NPV. In the planned upcoming phase of CBA, a series of building cooling improvement scenarios can be further defined, incorporating more than one ECM in combination with socio-economic factors evaluated in the initial CBA phase. Additionally, the analysis of ECM effects in multifamily housing can be expanded. This broader national analysis aims to encompass a holistic and comprehensive system-level perspective, including factors such as avoided power sector infrastructure investments, domestic job creation, domestic manufacturing job creation, and gross domestic product (GDP) growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-Economic Analysis of Dynamic Building Envelopes Comprising Phase Change Materials and Switchable Insulations: Preprint

Integrating phase change materials (PCMs) in building envelopes is a recognized technique to reduce the space heating/cooling loads and provide load shedding and shifting capacity. However, PCM benefits have been found to reduce dramatically with increase in the insulation requirements. Dynamic building envelopes that can alter their thermal resistance based on the indoor and outdoor conditions can effectively harness free ambient heating/cooling, thereby greatly enhancing the benefits of the PCM-integrated envelope in managing thermal loads. In this study, we examine various combinations of PCMs and switchable insulations and compare their combined impact on heat flow through the building envelope. Using numerical analysis, we investigate the PCM- and switchable insulation-integrated building walls, calculate the potential energy saving benefits compared to the conventional static walls, and finally perform technoeconomic analysis to estimate the acceptable cost of the technology under various payback period scenarios.

dynamic building envelopes↗

Techno-Economic Analysis of Dynamic Building Envelopes Comprising Phase Change Materials and Switchable Insulations

Integrating phase change materials (PCMs) in building envelopes is a recognized technique to reduce the space heating/cooling loads and provide load shedding and shifting capacity. However, PCM benefits have been found to reduce dramatically with increase in the insulation requirements. Dynamic building envelopes that can alter their thermal resistance based on the indoor and outdoor conditions can effectively harness free ambient heating/cooling, thereby greatly enhancing the benefits of the PCM-integrated envelope in managing thermal loads. In this study, we examine various combinations of PCMs and switchable insulations and compare their combined impact on heat flow through the building envelope. Using numerical analysis, we investigate the PCM- and switchable insulation-integrated building walls, calculate the potential energy saving benefits compared to the conventional static walls, and finally perform techno-economic analysis to estimate the acceptable cost of the technology under various payback period scenarios.

dynamic building envelopes↗

Improving dairy manure hydrolysis and acidification through microbial community restructuring by adaptation to hyperthermophilic conditions

Dairy manure (DM) contributes significantly to greenhouse gas emissions and ecosystem degradation, yet its resistance to biodegradation hinders widespread bioprocessing applications. Lignocellulosic materials in DM pose a particular challenge because of their recalcitrance. Bioprocessing under hyperthermophilic (≥70 °C) conditions potentially offers an advantage over traditional fermentation temperatures due to enhanced activity of enzymes and the kinetics of enzymatic reactions. This can lead to a higher conversion rate and a greater extent of biomass hydrolysis and acidification. To test the validity of this hypothesis, the current study evaluated the efficacy of anaerobic hydrolysis and acidogenic fermentation of DM under mesophilic, thermophilic, and hyperthermophilic conditions. All inocula were adapted to corresponding temperatures but were derived from the same mesophilic source. Hyperthermophilic conditions resulted in superior DM hydrolysis efficiency (53%) compared to mesophilic (34%) and thermophilic (42%) conditions. The hyperthermophilic environment was particularly favorable to the decomposition of crude proteins and hemicellulose, which were reduced by 64% and 54%, respectively. Furthermore, hyperthermophilic fermentation also yielded the highest volatile fatty acid (VFA) production rate of 460 mg/L/day during the first four days, representing improvements of 50% and 90% over mesophilic and thermophilic conditions. In part, this was attributed to the enhanced production of branched-chain VFAs, including an increase of 6–10% in isobutyric acid and 12–13% in isovaleric acid. At hyperthermophilic conditions, however, there was no accumulation of VFAs during the days 5–8 of fermentation, which could be due to acetate conversion by the syntrophic acetate-oxidizing bacteria. A considerable gain in hydrolysis efficiency and VFA production rate were accompanied by a reduction in microbial diversity, which suggests that hyperthermophilic temperature is a favorable environment for the selection of organisms with enhanced DM hydrolysis and fermentation capabilities. A significantly increased relative abundance of xylanolytic Caldicoprobacter (23% of population) and proteolytic Thermovirga (9% of population) could be the major contributors to improved decomposition of hemicellulose and protein. As revealed by the techno-economic analysis, acidogenic fermentation of DM at 70 °C and a retention period of 4 days provides the greatest positive net present value, highest internal rate of return of 9.2%, and shortest investment payback period of 9 years. Furthermore, this study demonstrates that hyperthermophilic conditions enable superior deconstruction and bioconversion of lignocellulose-containing biomass into VFAs under reduced retention times, offering a promising approach for improving DM management and generating bioproducts.

09 BIOMASS FUELS↗

Colorado Residential Retrofit Energy District (CoRRED) Phase I: Final Modeling Results

Electrification of buildings and transportation coupled with increased deployment of distributed energy resources (DERs) has been identified as a key step toward meeting emissions reduction goals across the U.S. Examples of pilot projects that feature innovative, 'smart' electric neighborhoods are largely focused on new construction projects, but there is a need to address the millions of existing homes so that they too may accommodate cleaner yet variable energy production in ways that benefit both the utility grid and the homes' residents. The Colorado Residential Retrofit Energy District (CoRRED) project used building and grid co-simulation tools to model an advanced energy district demonstration in an existing residential neighborhood in Denver, Colorado, and explored how existing building and utility infrastructures can be enhanced with combinations of traditional energy-efficiency retrofit measures and integration of solar panels and other DER technologies to provide better affordability and reliability. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate. Our results clearly indicate that incorporating DERs into efficient electrification produces much bigger utility bill savings on an annual basis than efficient electrification without DERs. While electrifying a neighborhood will increase the maximum load, batteries and solar panels can reduce load during peak hours so that the community can be a net producer during peak periods. A remaining challenge is to overcome first cost barriers to implementing energy-efficiency and DER technologies, as modest utility bill savings require long payback periods that are not practical for most homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic, Feasibility, and Life Cycle Analysis of Renewable Propane (Final Report)

The Propane Education and Research Council (PERC) has engaged with the National Renewable Energy Laboratory (NREL) to develop information that is critical to understanding the current and future landscape for renewable propane (RP) and the value proposition for recovery of RP from existing and planned HEFA biorefineries. In summary the following outcomes are identified from this study: 1) production of incremental RP by increasing the severity of the hydroisomerization step is insignificant to the overall propane yield from a HEFA biorefinery, however production of renewable butane (or LPG 2 ) is quite significant thus suggesting alternate strategies for valorizing these fractions; 2) the value proposition for recovering RP and renewable LPG is quite strong, with capital recovery payback periods of 14 months for a small biorefinery producing 3.5 million gallons per year RP to as short as 2 months for a large biorefinery producing 87 million gallons per year RP. Paybacks for renewable LPG are as much as 50% shorter; and 3) current and projected expansions of renewable diesel will greatly expand the potential availability of RP as a by-product. Several promising new pathways are under development but will not significantly increase production of RP for the next decade.

09 BIOMASS FUELS↗

Techno-economic analysis of sugarcane bagasse and straw conversion into cellulosic ethanol via consolidated bioprocessing

Cellulosic biofuels offer a sustainable alternative to fossil fuels and a means to mitigate climate change. Consolidated bioprocessing (CBP) featuring engineered thermophilic bacteria, combined with mechanical disruption during fermentation (cotreatment), has potential to lower production costs compared to featuring thermochemical pretreatment and added cellulase. A techno-economic analysis was conducted (230 million L ethanol/year) from sugarcane bagasse and straw at stand-alone facilities generating electricity from residues. Three scenarios were evaluated: Conventional, featuring hydrothermal pretreatment, fungal cellulase, and yeast fermentation (current commercial standard); Mid-term CBP, relying on bagasse solubilization without pretreatment or cotreatment; and Mature CBP, incorporating cotreatment but no pretreatment. Results for these scenarios in this order were: fixed capital investment (CapEx) $\$$589M, $\$$658M, and $\$$472M; net annual revenue (EBITDA) $\$$56M, $\$$96M, and $\$$94M; and minimum ethanol selling price 0.73, 0.61, and 0.48 US$\$$/L. Payback periods were 10.5, 6.9, and 5.1 years, while all scenarios showed <5 years at European prices for scales >100M L/year. Sensitivity and risk analysis highlighted ethanol price as the most critical variable. It is notable that Mid-term CBP had shorter payback times and better overall economic feasibility compared to Conventional. Our results underscore opportunities for research-driven innovation on low-cost cellulosic ethanol technologies in Brazil and elsewhere.

Consolidated bioprocessing↗

Techno-economic and environmental assessment of solar-based electrical vehicles charging stations integrated with hydrogen production

With the growing interest in adopting both commercial and residential electric vehicles (EVs) utilizing green renewable energy, the techno-economic assessment of EV charging stations with solar energy is a critical aspect of the transition to sustainable transportation. However, battery storage capacity for variable solar energy production is becoming increasingly less cost-effective due to the higher Lithium price. Complementing solar energy production and battery storage, the potential of combining green hydrogen fuel energy integration with solar energy for EV charging stations can provide a sustainable alternative to reach carbon-free transportation. This research aims to assess the technical and economic viability of grid-connected Photovoltaic (PV)-based EV charging stations across Kentucky based on existing EV load profiles. The study considers different PV system sizes, locations, orientations, and the impact of net metering policies and electricity tariffs on the profitability of the PV systems. Further, using excess PV energy, Lithium-Ion batteries will be charged, which will be assessed considering the techno-economic and environmental impacts of green EV charging stations. To further enhance green renewable energy production, we also investigated the feasibility of on-grid PV-based EV charging stations with Lithium-Ion batteries charged during low tariff periods. In comparison with these scenarios, we studied the potential benefits of integrating green hydrogen energy production using excess solar energy with and without governmental incentives. Furthermore, we assess the environmental impact of these green EV charging stations across Kentucky. Our study indicates that EV stations across Kentucky have similar techno-economic feasibility with insignificant deviation in the levelized cost of electricity, payback period, and PV energy fraction with/without Li-Ion batteries. However, with green hydrogen production, the marginal H 2 production cost indicates the first scenario (on-grid PV energy charging) is the most significant, roughly 10 USD/Kg, which is similar to 1.5 times higher than the second (charging during low-tariff periods) and the third scenarios (power grid to satisfy the demand deficit - approximately 6.5 USD/Kg). From the environmental perspective, the second scenario would be a good option for either hybrid EV/H 2 or EV charging stations in Kentucky, factoring in the hydrogen production cost and the carbon footprint.

08 HYDROGEN↗

Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

JUSTIFI: Open-Source Software for Identifying and Quantifying Non-Energy Benefits

The integration of Non-Energy Benefits (NEBs) into energy efficiency initiatives is essential for operational excellence in manufacturing. This presentation and software demonstration explore how quantifying NEBs such as improved safety, increased quality, and enhanced productivity, can strengthen business cases for energy investments, leading to better payback periods and alignment with organizational goals. We introduce JUSTIFI, a free, open-source software by the U.S. Department of Energy that aids in the measurement of NEBs and enhances understanding of their impact on Key Performance Indicators (KPIs) and return on investment (ROI). JUSTIFI features an intuitive interface for identifying NEBs, customizable reporting tools, and comprehensive system cataloging, empowering companies to effectively communicate the value of energy efficiency projects. By leveraging this innovative tool, organizations can better navigate energy efficiency assessments and drive support for their energy management initiatives.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of Phase Change Plaster/Paste Composites for Building Envelopes

Thermal energy storage (TES) materials increase a building’s thermal mass and provide the flexibility to shave and time-shift energy use. These materials are needed to enable grid-interactive efficient buildings, allowing building occupants to lower costs by leveraging free ambient heating/cooling as well as shifting consumption to cheaper electricity periods. Phase change materials (PCMs) that store heat through a solid-liquid/solid-solid transformation are of particular interest for TES because of their ability to store large amounts of energy across a constant temperature or very small temperature range. Furthermore, previous studies on PCM building envelopes evaluated products that may only be incorporated as part of new construction and are not easily applicable to existing, energy-intensive buildings. In this work, we leverage laboratory PCM characterization and whole-building energy simulation to study the energy and cost savings of PCM plaster/paste coatings, which can be applied post construction to both new builds and retrofits of existing buildings (about 40% of residential buildings in the United States fall into the retrofit category). We evaluated the energy impact of PCM plaster/paste composites for a single-family residential building in the United States, including layer design (location and thickness), composite properties (phase change temperature, energy density, and shape of the enthalpy curve), and U.S. climate zone. The enthalpy curve shape of PCM shows that phase change temperature and energy density are not the only two parameters that must be considered for PCM selection. Maximizing the energy density amid the effective TES zone is key to boosting energy savings. We also studied PCM price targets with the aim of achieving reasonable payback periods based on both block and time-of-use electricity rates. Moreover, we developed an empirical equation to provide a rough estimate of the energy savings potential of incorporating PCM without the need to perform detailed simulations. These results will help guide the selection and design of PCM plaster/paste composite elements for residential building envelopes.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Understanding Advanced Vehicle Technology Adoption Potential in Commercial Fleets Across Major Trucking Sectors

Adopting advanced vehicle technologies, such as battery-electric, hybrid, and hydrogen fuel cell vehicles, can be an effective strategy for reducing fleet owners' operating costs. However, different trucking sectors, such as private and for-hire carriers and short- or long-haul operations, may face unique challenges in adopting those vehicle technologies due to their own operational needs and budget constraints. Current studies on fleet-wide vehicle technology projections frequently overlook such sectoral differences and fail to capture variation in adoption potential across sectors. This study addresses this gap by analyzing the disparities in the total cost of ownership (TCO) and payback period (PBP) among a large and heterogeneous sample of fleet owners. It aims to understand the sectoral differences in the long-term potential for adopting advanced vehicle technologies. Utilizing the 2021 US Vehicle Inventory and Use Survey (US VIUS), which offers data on various commercial vehicle sectors, their operational patterns, and current vehicle assets, this research estimates the TCO and PBP for individual trucks over multiple future years. The results reveal variation in the cost-effectiveness of different vehicle technologies across trucking sectors, as well as the potential technology landscape in both the short and long term. The findings from this study can inform policymakers and practitioners on how to prioritize sectors with lower barriers for advanced vehicle technology adoption and support industries that face challenges in switching to advanced vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot-Scale Testing of an Integrated Circuit for the Extraction of Rare Earth Minerals and Elements from Coal and Coal Byproducts Using Advanced Separation Technologies

The primary objective of this project was to develop and demonstrate an integrated pilot-scale circuitry for recovering high-value rare earth elements (REEs) from coal and coal byproducts. The target performance was to produce a mixed REE product with content of at least two percent by weight on a dry mass basis in a cost-effective and environmentally benign manner. During the first nine months of the project period (Phase 2 Budget Period 2), pilot plant construction was completed including all field site startup activities such as permitting, engineering design, procurement/bidding, unit fabrication, site construction, equipment installation, module assembly, safety training, and circuit shakedown. During the remaining 21 months of project period (Phase 2 Budget Period 3), detailed field-testing activities were performed including feedstock sample collection and preparation, exploratory testing, circuit modification, detailed parametric study, and performance optimization. A detailed techno-economic analysis was performed based on the pilot plant testing findings which provided various scenarios for REE production. The project successfully accomplished the proposed target performance by producing mixed rare earth oxide (REO) with greater than 90% purity by weight in a continuous pilot scale operation from two distinctly different coarse refuse materials (i.e., West Kentucky No. 13 and Fire Clay coal seams), and at least three secondary sources (i.e., heap leach process and naturally formed acid mine drainage system). Project partners included the University of Kentucky, Virginia Tech, West Virginia University, Alliance Coal, Blackhawk Mining, Mineral Refining Company, and Mineral Separation Technologies. The pilot scale test facility was constructed at a former mining complex owned by Alliance Natural Resource Partners (Alliance Coal). The site was rehabilitated to accommodate the equipment installation, construction and fabrication, electrical power requirement, water line management and containment. The process units constructed and installed included X-ray sorting unit, crushing and grinding unit, physical separation unit, acid leaching unit, solvent extraction unit, and wastewater management unit. A rare earth mineral concentration unit was constructed as a standalone unit for flexible operation. A detailed environmental assessment and control plan was carried out to identify and quantify any potential impacts of the pilot-scale processing circuitry on the human and eco-system health and well-being. Corresponding mitigation strategies and control measures were provided. A conceptual flowsheet was developed to effectively remove thorium and uranium from high purity rare earth oxide mix or any potential radionuclide enriched stream. The two distinct feedstock materials were secured from the Blackhawk Mining Complex in eastern Kentucky where the Fire Clay (Hazard No. 4) seam is processed. The West Kentucky No. 13 (Baker) coarse refuse material was collected from an active process stream at an Alliance coal preparation plant located in western Kentucky. Characterization analysis indicated that both of feed materials generated from the two sources contained >300 ppm of TREEs on a dry whole mass basis which met the requirements for a qualified feed stock. The two feedstocks were further upgraded using a dual x-ray sorter to prepare the feed material for hydrometallurgical circuit. Thermal treatment on feed material prior to leaching was found to: 1) improve the leaching recovery of REEs, 2) increase the leaching kinetics, and 3) allow the leaching reaction to occur at lower acidity. Roasting at 600°C was selected as the pre-treatment condition for both West Kentucky No. 13 and Fire Clay coarse refuse material. Over 40% of leaching recovery was achieved by roasting West Kentucky No. 13 material having a top particle size of 3 mm in the pilot scale operation using 1.2M sulfuric acid leaching at 75OC. Initial pilot scale testing involved continuous operation of the pilot plant for 94 hours. The leaching unit was operated at solid-to-liquid ratio of 1 to 10 (w/v) using 0.5M sulfuric acid solution at a temperature of 75°C. The continuous solvent extraction circuit utilized rougher and cleaner units with DEHPA and TBP as the extractants. An innovative stripping circuit was developed to accumulate the REE concentration in the stripping solution to a level above 600 ppm. A bleed stream from the recycled strip solution was treated using oxalic acid precipitation which produced a high grade rare earth oxalate. The oxalate product was roasted to remove the oxalate which produced a rare earth oxide product having a purity greater 90%. Due to high concentrations of contaminant ions in the pregnant leach solution (PLS), a modified flowsheet was developed that involved pre-concentration of the REEs using multiple stages of precipitation and redissolution. The advantage of this process was improved removal of contamination before the downstream purification process and a significant cost reduction relative to the circuit that utilized the solvent extraction process. The modified circuitry included processes involving leaching, multistage precipitation, redissolution, and oxalate precipitation followed by roasting of the oxalate product. The circuit produced a mixed REO that was 92.96% pure from the initial test. A detailed parametric test plan was carried out which involved varying key parameters including solids feed rate, acid flowrate, acid concentration, multistage precipitation pH, redissolution pH, oxalate precipitation dosage and pH. The response variables included REE recovery, contaminant recovery, REO product grade and overall chemical consumption. Test results indicated that the acid-to-solid ratio is the key parameter to leaching efficiency as performance deteriorated with an increase in solids concentration. The optimal pH determined for REE precipitation and redissolution was 6.5 and 2.5, respectively. Additional tests were conducted to further improve the flowsheet. Recirculating a portion of the PLS to the feed of the leach tanks improved the leaching performance by lowering the pH of the leaching system and reducing the contamination recovery by shortening the residence time. Moreover, the removal of Al prior to REE precipitation significantly reduced the oxalic acid consumption in the oxalate precipitation circuit. The modified circuit produced over 90% grade REO by weight from both West Kentucky No. 13 and Fire Clay coarse refuse material in pilot scale continuous test programs. A case analysis model was developed to project the REE and major contaminants concentration in each PLS stream based on the leaching condition, pH cut point, and oxalic acid dosage. A correlation was established using empirical and semi-empirical models. Using the models, chemical consumption required for each stage was predicted based on the projected performance of the hydrometallurgy circuit. After identifying the optimum conditions, validation tests were carried out for the treatment of both West Kentucky No. 13 and Fire Clay coarse refuse materials in the pilot plant. The actual circuit performance and chemical consumptions were very close to the model predictions. Other than the two coarse refuse sources, several secondary feedstocks were also tested in the pilot plant facility. A “heap leach” system was constructed using the coarse refuse material generated from cleaning the West Kentucky No. 13 seam coal. Using the two stage SX rougher and cleaner circuit, a concentrate with a grade >90% REO was produced while recovering >97% of the REEs from the heap leach PLS. Naturally generated acid mine drainage (AMD) from West Kentucky No.13 mine was processed using the multistage precipitation circuit in the pilot plant in a test conducted for a period of 32 hours. The final grade of the mix RE oxide produced from the AMD was 90.84% with an overall circuit recovery of 64%. The primary source of REE was the selective precipitation steps involving iron and aluminum rejection. The hydrophobic-hydrophilic separation (HHS) process was proven to effectively recover coal from fine waste materials. For REM recovery, the HHS process was able to produce concentrates at grades of approximately 1.8% REE on an ash basis; however, recovery values were typically low, <10%, under the optimal conditions determined in the laboratory-scale testing. Staged testing of the pilot-scale HHS process for coal recovery and semi-continuous laboratory testing for REM testing showed that a total concentration ratio of more than 15x was observed for the REM recovery process. A circuit simulation package was developed for REE extraction and purification using a spreadsheet-based platform (Microsoft Excel). The REESim circuit simulation package is configured to track the mass and volume flows of components passing through a series of unit operations specified and configured by the user. The mass rates can then be utilized by the user to determine important performance indicators such as product mass yields, concentrate purity levels, element-by-element recoveries, and so forth. The techno-economic analysis showed that the roasting and leaching operations were the most expensive capital items, each contributing approximately 30% to the total capital cost. One notable contributor to the high production costs was the low REE recovery observed in the pilot scale trials. The product basket price was shown to have a strong influence on the economic viability of the scenarios, with the scandium price being the most significant influencer. Operating cost was shown to be extremely sensitive to REE recovery, REE feed grade, and leaching acid consumption. An analysis of ten different scenarios for a 500 t/h commercial operation revealed that three were economically favorable, producing internal rates of return varying from 27.7% to 33.1% and payback periods of 4 to 5 years. The project successfully developed and demonstrated a process to recover REEs from coal and coal byproducts in a pilot-plant operation which consistently produced over 90% grade REO mix from varies types of feedstocks. Commercialization analysis showed that the technology readiness level successfully achieved TRL 6 at the end of the project and demonstrated the need and the potential for scaling the process to further advance the technologies toward the goal of providing a domestic supply of REEs at a commercial scale.

01 COAL, LIGNITE, AND PEAT↗

Environmental and economic analyses of chemical recycling via dissolution of waste polyethylene terephthalate

Globally, more than 1000 organizations and 175 nations are facing the plastic waste problem and have realized the need to transition from “linear-to-circular” economy of plastics. While the current mechanical recycling technologies for plastics are struggling to increase the U.S. plastic recycling rates beyond 9%, chemical recycling technologies become important complementary technologies to the predominant mechanical recycling that are needed to realize the circular economy in plastics supply chains. Dissolution is one such chemical recycling technology that can recycle waste plastic back into high-quality virgin grade plastic. However, the environmental and economic impacts of chemical recycling of waste polyethylene terephthalate (PET) via dissolution technology using a green solvent are unknown. Our study evaluated environmental metrics such as greenhouse gas (GHG) emissions and cumulative energy demand, and economic metrics such as net present value (NPV), minimum selling price, payback period, return on investment, and discounted internal rate of return for three dissolution processes with polymer recovery via anti-solvent, evaporation, and cooling precipitation techniques. The dissolution process with evaporation technique was the most economically favorable, whereas that with cooling technique was the most environmentally favorable. The anti-solvent approach had low economic performance and the highest environmental impacts. The NPV for all of these technologies ranged from $2.67 MM to $10.93 MM for a capacity of 8,400 MT/year and was found to be the highest for dissolution with evaporation approach and the least for anti-solvent approach. The cradle-to-gate GHG emissions and energy demand for PET dissolution processes ranged from 1.33-3.77 kg CO2-eq/kg of chemically recycled (CR) PET and18.9-56.1 MJ/kg of CR-PET, respectively. These economic and environmental metrics will be helpful in evaluating the sustainability of circular PET supply chains in the U.S.

09 BIOMASS FUELS↗