Search NASA⌕ Search

SEARCH · Search NASA

Results for “persistent image”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Urban Observatory: A Multi-Modal Imaging Platform for the Study of Dynamics in Complex Urban Systems

We describe an “Urban Observatory” facility designed for the study of complex urban systems via persistent, synoptic, and granular imaging of dynamical processes in cities. An initial deployment of the facility has been demonstrated in New York City and consists of a suite of imaging systems—both broadband and hyperspectral—sensitive to wavelengths from the visible (∼400 nm) to the infrared (∼13 micron) operating at cadences of ∼0.01–30 Hz (characteristically ∼0.1 Hz). Much like an astronomical survey, the facility generates a large imaging catalog from which we have extracted observables (e.g., time-dependent brightnesses, spectra, temperatures, chemical species, etc.), collecting them in a parallel source catalog. We have demonstrated that, in addition to the urban science of cities as systems, these data are applicable to a myriad of domain-specific scientific inquiries related to urban functioning including energy consumption and end use, environmental impacts of cities, and patterns of life and public health. We show that an Urban Observatory facility of this type has the potential to improve both a city’s operations and the quality of life of its inhabitants.

54 ENVIRONMENTAL SCIENCES↗

Persistent hot carrier diffusion in boron arsenide single crystals imaged by ultrafast electron microscopy

Cubic boron arsenide (BAs) is promising for microelectronics thermal management because of its high thermal conductivity. Recently, its potential as an optoelectronic material is also being explored. However, it remains challenging to measure its photocarrier transport properties because of small sizes of available high-quality crystals. Here, we use scanning ultrafast electron microscopy (SUEM) to directly visualize the diffusion of photocarriers in BAs single crystals. Surprisingly, we observed ambipolar diffusion at low optical fluence with persistent hot carrier dynamics for above 200 ps, which can likely be attributed to the large frequency gap between acoustic and optical phonons, the same feature that is responsible for the high thermal conductivity. At higher optical fluence, we observed spontaneous electron-hole separation. Our results show BAs is an attractive optoelectronic material combining high thermal conductivity and excellent photocarrier transport properties. Finally, our study also demonstrates the capability of SUEM to probe photocarrier transport in emerging materials.

36 MATERIALS SCIENCE↗

Persistence of Late Substantial Patient-Reported Symptoms (LAPERS) After Radiochemotherapy Including Image Guided Adaptive Brachytherapy for Locally Advanced Cervical Cancer: A Report From the EMBRACE Study

This report describes the persistence of late substantial treatment-related patient-reported symptoms (LAPERS) in the multi-institutional EMBRACE study on magnetic resonance image guided adaptive brachytherapy in locally advanced cervical cancer (LACC).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stabilization and control of persistent current magnets using variable inductance

Ultra-stable, tunable magnetic fields are desirable for a wide range of applications in medical imaging, electron microscopy, quantum science, and atomic physics. Superconducting magnets operated in persistent current mode, with device current flowing in a closed superconducting loop disconnected from a power source, are a common approach for applications with the most stringent requirements on temporal field stability. In this work, we present a method for active control of this persistent current by means of dynamic inductance change within the superconducting circuit. For a first realization of this general technique, we consider a variable superconducting inductor placed in series with the main magnet. The inductor acts as a dynamic flux storage device capable of transferring flux to or from the main magnet through inductance change. This allows for fine and fast adjustments of the persistent current without the use of thermal switches that limit the speed and accuracy of many present-day methods. With first experiments employing this technique, we demonstrate stabilization of a 1.95 T Nb–Ti round lens for electron microscopy against decay resulting from residual losses in the superconducting circuit, and more generally show flexibility for precise control over the magnitude and waveform of the persistent current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Statistical Inference Over Persistent Homology Predicts Fluid Flow in Porous Media

Here, we statistically infer fluid flow and transport properties of porous materials based on their geometry and connectivity, without the need for detailed We summarize structure by persistent homology and then determines the similarity of structures using image analysis and statistics. Longer term, this may enable quick and automated categorization of rocks into known archetypes. We first compute persistent homology of binarized 3D images of material subvolume samples. The persistence parameter is the signed Euclidean distance from inferred material interfaces, which captures the distribution of sizes of pores and grains. Each persistence diagram is converted into an image vector. Here, we infer structural similarity by calculating image similarity. For each image vector, we compute principal components to extract features. We fit statistical models to features estimates material permeability, tortuosity, and anisotropy. We develop a Structural SIMilarity index to determine statistical representative elementary volumes.

36 MATERIALS SCIENCE↗

An unmet clinical need: The history of thrombus imaging

Robust thrombus imaging is an unresolved clinical unmet need dating back to the mid 1970s. While early molecular imaging approaches began with nuclear SPECT imaging, contrast agents for virtually all biomedical imaging modalities have been demonstrated in vivo with unique strengths and common weaknesses. Two primary molecular imaging targets have been pursued for thrombus imaging: platelets and fibrin. Some common issues noted over 40 years ago persist today. Acute thrombus is readily imaged with all probes and modalities, but aged thrombus remains a challenge. Similarly, anti-coagulation continues to interfere with and often negate thrombus imaging efficacy, but heparin is clinically required in patients suspected of pulmonary embolism, deep venous thrombosis or coronary ruptured plaque prior to confirmatory diagnostic studies have been executed and interpreted. These fundamental issues can be overcome, but an innovative departure from the prior approaches will be needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photoelectron Imaging of Doubly Charged Anions, -O2C(CH2)nCO2- (n=2-8): Observation of Near 0 eV Electrons Due to Secondary Dissociative Autodetachment

The hallmark of multiply charged anions is the repulsive Coulomb barrier (RCB), which prevents low energy electrons from being emitted in photodetachment experiments. However, using photoelectron imaging, we have observed persistent near zero-eV electrons during photodetachment of doubly charged dicarboxylate anions, -O2C(CH2)nCO2- (Dn2-, n = 2-8). Here we show that these low energy electron signals are well structured and are independent of the detachment photon fluxes or energies. The relative intensities of these signals are dependent on n, with maxima at n = 2, 4, 6. These near zero-eV electrons cannot come from direct photodetachment of the dianions and are proposed to come from decarboxylation of the product radical anions upon photodetachment of the parent dianions [•O2C(CH2)nCO2- → CO2 + •(CH2)nCO2-], followed by dissociative autodetachment [•(CH2)nCO2- → (CH2)n + CO2 + e] or hydrogen-transfer-induced electron detachment [•(CH2)nCO2- → CH2=CH(CH2)n-2CO2H + e]. Energetic considerations suggest that these processes are exothermic. It is further observed that solvation by one water molecule quenches the low energy electron signals in the spectra of Dn2-(H2O), consistent with the proposed mechanisms. These indirect dissociative autodetachment processes are expected to involve cyclic transition states for n > 2, in agreement with the dependence on the chain length due to the anticipated strains in the intermediate steps. The quenching of the low energy electron signals by one water molecule demonstrates the importance of solvation on chemical reactions. ________________________

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE 2012 HUBBLE ULTRA DEEP FIELD (UDF12): OBSERVATIONAL OVERVIEW

We present the 2012 Hubble Ultra Deep Field campaign (UDF12), a large 128 orbit Cycle 19 Hubble Space Telescope program aimed at extending previous Wide Field Camera 3 (WFC3)/IR observations of the UDF by quadrupling the exposure time in the F105W filter, imaging in an additional F140W filter, and extending the F160W exposure time by 50%, as well as adding an extremely deep parallel field with the Advanced Camera for Surveys (ACS) in the F814W filter with a total exposure time of 128 orbits. The principal scientific goal of this project is to determine whether galaxies reionized the universe; our observations are designed to provide a robust determination of the star formation density at z ∼> 8, improve measurements of the ultraviolet continuum slope at z ∼ 7-8, facilitate the construction of new samples of z ∼ 9-10 candidates, and enable the detection of sources up to z ∼ 12. For this project we committed to combining these and other WFC3/IR imaging observations of the UDF area into a single homogeneous dataset to provide the deepest near-infrared observations of the sky. In this paper we present the observational overview of the project and describe the procedures used in reducing the data as well as the final products that were produced. We present the details of several special procedures that we implemented to correct calibration issues in the data for both the WFC3/IR observations of the main UDF field and our deep 128 orbit ACS/WFC F814W parallel field image, including treatment for persistence, correction for time-variable sky backgrounds, and astrometric alignment to an accuracy of a few milliarcseconds. We release the full, combined mosaics comprising a single, unified set of mosaics of the UDF, providing the deepest near-infrared blank-field view of the universe currently achievable, reaching magnitudes as deep as AB ∼ 30 mag in the near-infrared, and yielding a legacy dataset on this field.

79 ASTRONOMY AND ASTROPHYSICS↗

PERSISTENT ASYMMETRIC STRUCTURE OF SAGITTARIUS A* ON EVENT HORIZON SCALES

The Galactic Center black hole Sagittarius A* (Sgr A*) is a prime observing target for the Event Horizon Telescope (EHT), which can resolve the 1.3 mm emission from this source on angular scales comparable to that of the general relativistic shadow. Previous EHT observations have used visibility amplitudes to infer the morphology of the millimeter-wavelength emission. Potentially much richer source information is contained in the phases. We report on 1.3 mm phase information on Sgr A* obtained with the EHT on a total of 13 observing nights over four years. Closure phases, which are the sum of visibility phases along a closed triangle of interferometer baselines, are used because they are robust against phase corruptions introduced by instrumentation and the rapidly variable atmosphere. The median closure phase on a triangle including telescopes in California, Hawaii, and Arizona is nonzero. This result conclusively demonstrates that the millimeter emission is asymmetric on scales of a few Schwarzschild radii and can be used to break 180° rotational ambiguities inherent from amplitude data alone. The stability of the sign of the closure phase over most observing nights indicates persistent asymmetry in the image of Sgr A* that is not obscured by refraction due to interstellar electrons along the line of sight.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Case Report: Differential diagnosis of hematuria in the emergency department: emphasizing double J stent-inferior vena cava fistula

Introduction Hematuria, a common clinical indicator of genitourinary tract pathology, arises from diverse etiologies including calculi, infections, malignancies, trauma, and iatrogenic causes. Initial evaluation requires hemodynamic assessment, identification of underlying causes, and urinary drainage optimization. This report highlights a rare case of iatrogenic hematuria secondary to double-J stent migration into the inferior vena cava. Case presentation A Chinese male presented with acute left flank pain and gross hematuria persisting for 4 h. Diagnostic imaging revealed a left ureteral stone, prompting double-J stent placement at a local hospital. Despite intervention, hematuria worsened, necessitating abdominal CT. Imaging identified proximal migration of the left double-J stent into the inferior vena cava, with no evidence of vascular injury. Due to concerns regarding inadequate drainage and infection risk, conservative management without catheter clamping was initiated prior to referral. Definitive treatment involved ureteroscopic stent removal under direct visualization at our institution, resulting in rapid symptom resolution. Conclusion This case emphasizes three critical clinical insights: (1) Persistent postoperative hematuria warrants consideration of iatrogenic causes, particularly following urologic device placement. (2) Imaging modalities, especially CT, are indispensable for detecting atypical stent migration. (3) Comprehensive history-taking must include prior urologic interventions to guide differential diagnosis. While double-J stent migration into major vessels remains exceptionally rare, its recognition prevents delayed management of potentially life-threatening complications. Clinicians should maintain heightened vigilance for device-related hematuria in patients with refractory symptoms post-procedurally, ensuring prompt imaging evaluation and multidisciplinary intervention when indicated.

Qi, Wenqi↗

Magnetic resonance visualization of conductive structures by sequence-triggered direct currents and spin-echo phase imaging

Purpose: Instrument visualization in interventional magnetic resonance imaging (MRI) is commonly performed via susceptibility artifacts. Unfortunately, this approach suffers from limited conspicuity in inhomogeneous tissue and disturbed spatial encoding. Also, susceptibility artifacts are controllable only by sequence parameters. This work presents the basics of a new visualization method overcoming such problems by applying sequence-triggered direct current (DC) pulses in spin-echo (SE) imaging. SE phase images allow for background free current path localization. Methods: Application of a sequence-triggered DC pulse in SE imaging, e.g., during a time period between radiofrequency excitation and refocusing, results in transient field inhomogeneities. Dependent on the additional z-magnetic field from the DC, a phase offset results despite the refocusing pulse. False spatial encoding is avoided by DC application during periods when read-out or slice-encoding gradients are inactive. A water phantom containing a brass conductor (water equivalent susceptibility) and a titanium needle (serving as susceptibility source) was used to demonstrate the feasibility. Artifact dependence on current strength and orientation was examined. Results: Without DC, the brass conductor was only visible due to its water displacement. The titanium needle showed typical susceptibility artifacts. Applying triggered DC pulses, the phase offset of spins near the conductor appeared. Because SE phase images are homogenous also in regions of persistent field inhomogeneities, the position of the conductor could be determined with high reliability. Artifact characteristic could be easily controlled by amperage leaving sequence parameters unchanged. For an angle of 30° between current and static field visualization was still possible. Conclusions: SE phase images display the position of a conductor carrying pulsed DC free from artifacts caused by persistent field inhomogeneities. Magnitude and phase images are acquired simultaneously under the same conditions without the use of extra measurement time. The presented technique offers many advantages for precise instrument localization in interventional MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Summary of May 21st and 22nd Shear Campaign [Slides]

We have streaked imaging of both smooth and roughened foils in both Ti and Al at both early and late times. Further work will be needed to check if the signal is strong enough on all shots to extract reliable mix-widths. The initial test of the 3 slit streaked imaging setup was unsuccessful. Streaked images of a driven shots using the slit on the target resulted in low signal, while un-driven shots showed much higher signals. The working hypothesis is that the signal dropped due to slit closure on the target; the successful NIF setup used a much wider slit, on the order of 100 um instead of 20 um. We were able to get good streak data by switching back to a 20 um pinhole at the front of the SSCA and removing the slits from the targets. To obtain the best late-time streak data we had to overlap the two TIM4 BL groups (on the BL driver). We have sets of plan view radiographs for at least three different times for both smooth and roughened foils in both Ti and Al. There are visually identifiable difference between the plan view radiographs of the smooth and enhanced roughened foils. The enhanced roughening is apparent in the plan view images at early times and seems to persist as the dominant structure scale into late times. We have several streaked plan view images. Further analysis will be required to determine if this can be turned into a viable platform for turbulence studies. Signal strength on the Al streaked plan view looks promising.

Plasma Physics & Fusion Technology(70)↗

Reconstructing magnetic deflections from sets of proton images using differential evolution

Proton imaging is a powerful technique for imaging electromagnetic fields within an experimental volume, in which spatial variations in proton fluence are a result of deflections to proton trajectories due to interaction with the fields. When deflections are large, proton trajectories can overlap, and this nonlinearity creates regions of greatly increased proton fluence on the image, known as caustics. The formation of caustics has been a persistent barrier to reconstructing the underlying fields from proton images. We have developed a new method for reconstructing the path-integrated magnetic fields, which begins to address the problem posed by caustics. Our method uses multiple proton images of the same object, each image at a different energy, to fill in the information gaps and provide some uniqueness when reconstructing caustic features. We use a differential evolution algorithm to iteratively estimate the underlying deflection function, which accurately reproduces the observed proton fluence at multiple proton energies simultaneously. We test this reconstruction method using synthetic proton images generated for three different, cylindrically symmetric field geometries at various field amplitudes and levels of proton statistics and present reconstruction results from a set of experimental images. Here, the method we propose requires no assumption of deflection linearity and can reliably solve for fields underlying linear, nonlinear, and caustic proton image features for the selected geometries and is shown to be fairly robust to noise in the input proton intensity.

47 OTHER INSTRUMENTATION↗

The persistent shadow of the supermassive black hole of M 87. I. Observations, calibration, imaging, and analysis

In April 2019, the Event Horizon Telescope (EHT) Collaboration reported the first-ever event-horizon-scale images of a black hole, resolving the central compact radio source in the giant elliptical galaxy M 87. These images reveal a ring with a southerly brightness distribution and a diameter of ∼42 μas, consistent with the predicted size and shape of a shadow produced by the gravitationally lensed emission around a supermassive black hole. These results were obtained as part of the April 2017 EHT observation campaign, using a global very long baseline interferometric radio array operating at a wavelength of 1.3 mm. Here, we present results based on the second EHT observing campaign, taking place in April 2018 with an improved array, wider frequency coverage, and increased bandwidth. In particular, the additional baselines provided by the Greenland telescope improved the coverage of the array. Multiyear EHT observations provide independent snapshots of the horizon-scale emission, allowing us to confirm the persistence, size, and shape of the black hole shadow, and constrain the intrinsic structural variability of the accretion flow. We have confirmed the presence of an asymmetric ring structure, brighter in the southwest, with a median diameter of 43.3−3.1+1.5 μas. The diameter of the 2018 ring is remarkably consistent with the diameter obtained from the previous 2017 observations. On the other hand, the position angle of the brightness asymmetry in 2018 is shifted by about 30° relative to 2017. The perennial persistence of the ring and its diameter robustly support the interpretation that the ring is formed by lensed emission surrounding a Kerr black hole with a mass ∼6.5 × 109 M⊙. The significant change in the ring brightness asymmetry implies a spin axis that is more consistent with the position angle of the large-scale jet.

79 ASTRONOMY AND ASTROPHYSICS↗

Anastomosing hemangioma of the liver: a case series

Purpose: To report imaging and pathologic features of five pathologically proven anastomosing hemangiomas of the liver (AHL). Methods: A retrospective review for AHL was conducted using our institutional database from 6/2004 to 3/2018. Histology proven AHL with radiologic imaging available for review were included. A total of five patients who met our criteria were identified from our institutional database. Computed tomography, ultrasound, and magnetic resonance imaging findings, including location, size, attenuation/signal intensity, enhancement characteristics, and additional imaging data were reviewed. The clinical and pathological data were also reviewed. Results: The imaging characteristics of AHL are variable, but features such as peripheral or diffuse hyperintensity on diffusion weighted imaging, arterial hyperenhancement without globular interrupted enhancement, and persistent enhancement without complete filling in the delayed phases were more characteristic of AHL. Imaging also demonstrated a lack of aggressive features. Conclusions: AHL present a diagnostic dilemma as they can mimic more malignant lesions, such as angiosarcoma, both on imaging and at pathology. While the imaging characteristics of AHL are variable, there are some features which can help distinguish AHL from other liver lesions. When the diagnosis of anastomosing hemangioma is known, the management of choice is primarily surveillance, as intervention can cause unnecessary morbidity, and no degeneration to malignancy has been identified to date.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatial DIC Errors due to Pattern-Induced Bias and Grey Level Discretization

Digital image correlation (DIC) is an optical metrology method widely used in experimental mechanics for full-field shape, displacement and strain measurements. The required strain resolution for engineering applications of interest mandates DIC to have a high image displacement matching accuracy, on the order of 1/100th of a pixel, which necessitates an understanding of DIC errors. In this paper, we examine two spatial bias terms that have been almost completely overlooked. They cause a persistent offset in the matching of image intensities and thus corrupt DIC results. We name them pattern-induced bias (PIB), and intensity discretization bias (IDB). We show that the PIB error occurs in the presence of an undermatched shape function and is primarily dictated by the underlying intensity pattern for a fixed displacement field and DIC settings. The IDB error is due to the quantization of the gray level intensity values in the digital camera. In this paper we demonstrate these errors and quantify their magnitudes both experimentally and with synthetic images.

47 OTHER INSTRUMENTATION↗