Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase two”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A two-equation turbulence model for two-phase flows

A two-equation turbulence model has been developed for predicting two-phase flows. The two equations describe the conservation of turbulence kinetic energy and dissipation rate of that energy for the carrier fluid in a two-phase flow. They have been derived rigorously from the momentum equations of the carrier fluid. Closure of the time-mean equations is achieved by modeling the turbulent correlations up to third order. The new model eliminates the need to simulate in an ad hoc manner the effects of the dispersed phase on turbulence structure. Preliminary testing indicates that the model is successful in predicting the main features of a round gaseous jet laden with uniform-size solid particles.

Elghobashi, S. E.↗

Liquid-phase turbulence measurements in air-water two-phase flows using particle image velocimetry

Liquid-phase turbulence plays a vital role in determining various gas-liquid two-phase flow parameters, such as void fraction distribution, bubble morphology, bubble-bubble interactions, and interfacial area concentration. In this study, a two-phase flow database including both the gas- and liquid-phases measurements was developed focusing on three bubbly flow conditions in an air-water two-phase flow loop with a vertical one-inch diameter circular pipe test section. A particle image velocimetry (PIV) system integrating an optical phase separation method, i.e., the planar laser-induced fluorescence (PLIF) technique using fluorescent particles and optical filtration, was applied to measure the liquid-phase turbulence information, including the time-averaged velocity, Reynolds stress, and turbulent kinetic energy for the liquid phase. The PIV measurements were taken at three ports along the test section at 14.5, 51.5, and 88.5 pipe inner diameters downstream of a bubble injector. In addition, a double-sensor conductivity probe was used to measure radial distributions of the local time-averaged void fraction and gas velocity. The measured liquid-phase turbulence was used to benchmark Sato's turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. Lastly, in the two bubbly flows tested that have low void fractions being less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction.

42 ENGINEERING↗

Phase Inversion in a Two-phase, BCC+B2, Refractory High Entropy Alloy

A phenomenon of "phase inversion", presumably the first ever experimental evidence in metallic alloys, is shown in a refractory high entropy alloy (RHEA), Al0.5NbTa0.8Ti1.5V0.2Zr. Phase inversion in crystalline solid systems is driven by the differences in elastic modulus of the two phases. Quenching from a high-temperature single phase field, the RHEA exhibits a co-continuous mixture of a disordered BCC and an ordered B2 phase, that upon isothermal annealing at 600°C develops via spinodal decomposition into a continuous B2 matrix with discrete cuboidal BCC precipitates aligned along the <001> directions. Longer term annealing at 600°C results in the development of necking constrictions along the B2 channels, eventually pinching-off these channels and making the BCC phase continuous with discrete B2 precipitates. This inversion the process can be related to the simultaneous operation of two processes:(i) spheroidization of the initially discrete cuboidal BCC precipitates driven by a reduction in the total interface energy and (ii) an increase in the stiffness of the B2 phase, relative to the BCC phase, due to chemical composition changes during annealing, forcing the B2 regions to become discrete driven by the reduction in the total elastic strain energy.

Soni, Vishal↗

Impact of particle loading and phase coupling on gas–solid flow dynamics: A case study of a two-phase, gas–solid flow in an annular pipe

The present study is devoted to a two-phase, gas–solid flow in an annular pipe (hollow cylinder) at an elevated pressure of 15 bars and moderate Reynolds number of circa 6000. The influence of the particle loading, the interaction between the phases, and turbulence dispersion on the flow dynamics is systematically studied by means of computational fluid dynamics simulations, employing the Ansys FLUENT commercial package. The cases with a particle volumetric fraction of 1.2% are referred to as “high particle loading,” and those with 0.13% are denoted as “low particle loading.” The following cases are investigated: (1) pure gas flow; (2) low particle loading two-phase flow with one-way coupling and with turbulence dispersion; (3) low particle loading two-phase flow with two-way coupling but without turbulence dispersion; (4) low particle loading two-phase flow with two-way coupling and with turbulence dispersion; (5) high particle loading two-phase flow with one-way coupling and with turbulence dispersion; (6) high particle loading two-phase flow with two-way coupling but without turbulence dispersion; and (7) high particle loading two-phase flow with two-way coupling and with turbulence dispersion. Additionally, the boundary layer is found to grow without fluctuations of the turbulent kinetic energy (TKE) for cases 1, 2, and 5. For case 4, the TKE fluctuations have been identified, although they appear to be less substantial than those in cases 6 and 7. The authors attribute the semi-chaotic nature of the TKE fluctuations to the particle loading and two-way coupling. In addition, the onset and development of the flow instability have been observed at a random axial distance in cases 4, 6, and 7. Such instability is also attributed to the two-way coupling with turbulence dispersion in the flow. It is concluded that the particle loading, one-way, or two-way coupling between the phases, and the turbulence dispersion models significantly influence the development of the flow dynamics with the same inlet and boundary conditions. Consequently, it is not a trivial question, which result a user should trust. The present computational results inspire to perform verification as well as experimental validation of the simulations, so the simulation results can subsequently be used with confidence for design analysis.

42 ENGINEERING↗

Microgravity fluid management in two-phase thermal systems

Initial studies have indicated that in comparison to an all liquid single phase system, a two-phase liquid/vapor thermal control system requires significantly lower pumping power, demonstrates more isothermal control characteristics, and allows greater operational flexibility in heat load placement. As a function of JSC's Work Package responsibility for thermal management of space station equipment external to the pressurized modules, prototype development programs were initiated on the Two-Phase Thermal Bus System (TBS) and the Space Erectable Radiator System (SERS). JSC currently has several programs underway to enhance the understanding of two-phase fluid flow characteristics. The objective of one of these programs (sponsored by the Microgravity Science and Applications Division at NASA-Headquarters) is to design, fabricate, and fly a two-phase flow regime mapping experiment in the Shuttle vehicle mid-deck. Another program, sponsored by OAST, involves the testing of a two-phase thermal transport loop aboard the KC-135 reduced gravity aircraft to identify system implications of pressure drop variation as a function of the flow quality and flow regime present in a representative thermal system.

Parish, Richard C.↗

Two phase pumping of cryogenic propellants

Two-phase cryogenic propellant pumping techniques developed during the past 5 years are discussed. During this period the theory of two-phase pumping of hydrogen was developed into an operational technique that can result in significant benefits to space vehicle propulsion systems. Using two-phase pumping techniques, zero LH2 tank net positive suction head (NPSH) was demonstrated on turbopump and rocket engine firings, and limited experimental results show that two-phase pumping of liquid oxygen is feasible. Design techniques were developed for improving the two-phase pumping capability of inducers.

H P Stinson↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗

Microgravity Two-Phase Flow Transition

Two-phase flows under microgravity condition find a large number of important applications in fluid handling and storage, and spacecraft thermal management. Specifically, under microgravity condition heat transfer between heat exchanger surfaces and fluids depend critically on the distribution and interaction between different fluid phases which are often qualitatively different from the gravity-based systems. Heat transfer and flow analysis in two-phase flows under these conditions require a clear understanding of the flow pattern transition and development of appropriate dimensionless scales for its modeling and prediction. The physics of this flow is however very complex and remains poorly understood. This has led to various inadequacies in flow and heat transfer modeling and has made prediction of flow transition difficult in engineering design of efficient thermal and flow systems. In the present study the available published data for flow transition under microgravity condition are considered for mapping. The transition from slug to annular flow and from bubbly to slug flow are mapped using dimensionless variable combination developed in a previous study by the authors. The result indicate that the new maps describe the flow transitions reasonably well over the range of the data available. The transition maps are examined and the results are discussed in relation to the presumed balance of forces and flow dynamics. It is suggested that further evaluation of the proposed flow and transition mapping will require a wider range of microgravity data expected to be made available in future studies.

Parang, M.↗

Two-phase working fluids for the temperature range of 50 to 350 deg, phase 2

Several two phase heat transfer fluids were tested in aluminum and carbon steel reflux capsules for over 25,000 hours at temperatures up to 300 C. Several fluids showed very good stability and would be useful for long duration heat transfer applications over the range 100 to 350 C. Instrumentation for the measurement of surface tension and viscosity were constructed for use with heat transfer fluids over the temperature range 0 to 300 C and with pressures from 0 to 10 atmospheres. The surface tension measuring device constructed requires less than a 1.0 cc sample and displays an accuracy of about 5 percent in preliminary tests, while the viscometer constructed for this program requires a 0.05 cc sample and shows an accuracy of about 5 percent in initial tests.

Saaski, E. W.↗

Two-Phase Accumulator

Two-phase accumulator maintains pressure and temperature in thermal-bus system within predetermined range during variations in heat load on system. Stores liquid and vapor ammonia. Exchanges liquid ammonia with condenser to adjust level of liquid in condenser. Prototype has capacity of 13 gallons (49 liters). Simple and highly reliable. Responds quickly, restoring pressure and temperature to proper values within minutes. Low in cost and requires little further development. Used to dispose of waste heat, such as that from electronic equipment or power-plant.

Kalb, Charles E.↗

Experimental and Analytical Study of Two-Phase Flow in Microgravity

A two-phase test loop has been designed and constructed to generate the necessary data for two-phase pressure drop and Critical Heat Flux (CHF) under reduced gravity conditions. A series of airplane trajectory tests aboard NASA KC-135 were performed and the data was used to evaluate the applicability of the earth gravity models for prediction of the reduced gravity data. Several commonly used correlations for the two-phase friction multiplier and critical heat flux were used to predict the data. It was generally concluded that the two-phase pressure drop can be predicted by the earth gravity correlations. The critical heat flux under reduced gravity conditions did not show a strong dependence on mass flow rate and the measured CHF were generally lower than the equivalent 1g conditions. The earth gravity models need to be modified for application to reduced gravities.

Abdollahian, D.↗

Estimation of the sugar cane cultivated area from LANDSAT images using the two phase sampling method

A two phase sampling method and the optimal sampling segment dimensions for the estimation of sugar cane cultivated area were developed. This technique employs visual interpretations of LANDSAT images and panchromatic aerial photographs considered as the ground truth. The estimates, as a mean value of 100 simulated samples, represent 99.3% of the true value with a CV of approximately 1%; the relative efficiency of the two phase design was 157% when compared with a one phase aerial photographs sample.

Parada, N. D. J.↗

Cell separation in immunoaffinity partition in aqueous polymer two-phase systems

Two methods for immunoaffinity partitioning are described. One technique involves the covalent coupling of poly (ethylene glycol) (PEG) to immunoglobulin G antibody preparations. In the second method PEG-modified Protein A is used to complex with cells and unmodified antibody. The effects of PEG molecular weight, the degree of modification, and varying phase system composition on antibody activity and its affinity for the upper phase are studied. It is observed that both methods resulted in effective cell separation.

Karr, Laurel J.↗

Thin hybrid capillary two-phase cooling system

A novel hybrid two-phase cooling system was developed that integrated a mechanically pumped two-phase loop with a capillary-driven two-phase cooling device. The latter cooling mechanism was based on evaporation/boiling from wick structures made by sintering copper particles on the interior surfaces of a copper cold plate. The cold plate provided cooling to two surfaces and each of them included four heaters in series. The novelty of the developed technology was preventing flooding of the evaporator wicks by isolating the evaporation surface from the pumped liquid flow that fed them. This arrangement allowed for a high liquid feed flow rate much greater than would be allowed by a capillary pumped system while maintaining a low thermal resistance at the evaporation surface. Using this approach, the cooling system removed over 850 W with a low pumping power below 1.0 W while using R245fa as the working fluid. The equivalent heat fluxes exceeded 970 W/cm 2 over areas less than 0.12 cm 2 . The measured thermal resistance was as low as 0.09 K-cm 2 /W. The presented thermal management solution enables an increase in the power of high heat flux electronic devices beyond the state-of-the-art.

42 ENGINEERING↗