Search NASA⌕ Search

SEARCH · Search NASA

Results for “pipeline corrosion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Destructive Examination Protocol for 3013-Container-Package Storing Plutonium-Bearing Materials

The 3013-container-package consists of a convenience, inner and outer container and is used for long-term storage of plutonium-bearing materials. A destructive examination (DE) protocol has been developed to examine the container package visually and with microscopic aid to find any corrosion conditions that could result in the loss of the integrity of the container package over its lifetime. The DE protocol contains three main steps: initial container examination, helium (He) leak testing, and detailed imaging and analysis of the inner container closure weld region (ICCWR). The ICCWR has been determined to be bounding, defined as exhibiting worst case conditions for stress corrosion cracking (SCC) of the inner container. To assess SCC in the ICCWR, the inner container lid is cut into quarters and the weld and He-leak testing gasket are removed. Then a citric acid wash is performed to remove adherent chlorides from the ICCWR. The wash is then sent for analysis to determine the concentration of chlorides in the ICCWR. While the analysis for chloride concentration is being performed, the quarter sections are further sectioned into 1/8th subsections by cutting each section in half. These subsections are washed using nitric acid to remove corrosion products. Then each subsection is imaged using a Wide Angle 3-D Measurement System (WAMS). After analysis of microscope images for potential SCC, additional imaging can be performed, including subsurface imaging. After review, a determination is made of whether the container integrity may potentially affect the safe storage of the material.

container↗

Evaluation of NETL’s Self-Healing Metallic Coating for Internal Corrosion Protection of Natural Gas Pipelines: Field Test

Steel pipelines are a safe, reliable, and affordable way to transport natural gas. However, the presence of impurities (e.g., water, carbon dioxide, and hydrogen sulfide) in the natural gas can cause internal corrosion, which can lead to pipeline leaks and failure. This paper reports on field tests of an innovative self-healing, corrosion-resistant, metallic coating developed at the National Energy Technology Laboratory (NETL) for protecting the interior surfaces of pipelines.

carbon dioxide (CO2)↗

Distributed fiber sensor and machine learning data analytics for pipeline protection against extrinsic intrusions and intrinsic corrosions

This paper presents an integrated technical framework to protect pipelines against both malicious intrusions and piping degradation using a distributed fiber sensing technology and artificial intelligence. A distributed acoustic sensing (DAS) system based on phase-sensitive optical time-domain reflectometry (φ-OTDR) was used to detect acoustic wave propagation and scattering along pipeline structures consisting of straight piping and sharp bend elbow. Signal to noise ratio of the DAS system was enhanced by femtosecond induced artificial Rayleigh scattering centers. Data harnessed by the DAS system were analyzed by neural network-based machine learning algorithms. The system identified with over 85% accuracy in various external impact events, and over 94% accuracy for defect identification through supervised learning and 71% accuracy through unsupervised learning.

Peng, Zhaoqiang↗

Dynamic Binary Complexes (DBC) as Super-Adjustable Viscosity Modifiers for Hydraulic Fracturing Fluids

In the preceding project year two, we refined three DBC formulations from a selection of over 50 different chemistries. The optimization study primarily encompassed testing for (i) reversibility extent, (ii) performance in the presence of chemical additives, (iii) adhesion and friction behavior during displacement in wellbores and pipelines, (iv) corrosion protection performance, and (v) injection performance with model fracture systems at the laboratory scale. Highly promising results obtained from all these tests signify the significant potential of DBCs in enhancing hydrocarbon recovery from unconventional reservoirs. The primary activities in the third project year included publishing experimental findings across multiple articles and conducting outreach initiatives. Throughout the year, we undertook tasks such as replicating experimental results, further optimizing various formulations and their associated experimental sets, and conducting additional tests to address missing components based on reviewer feedback and suggestions. We also explored the surfactant and friction-reduction aspects of selected formulations through drag reduction tests. In addition, we constructed an improved fracturing performance setup and performed flow injection tests. The specific DBC formulations focused on during this project period were A8/B1, A12/B5, and A10/B12. We also obtained results for additional DBC formulations and a select few commercial fracturing fluids for the purpose of comparison. Within the project's scope, we aim to enhance the experimental findings with the development of various models. The first two years focused on two key aspects: (i) the creation of a high-fidelity hydraulic fracturing model for non-Newtonian fluids to gain insights into the implementation of DBC fluids in fracking environments, and (ii) the development of a multiphase flow simulator for estimating total production, fluid saturation in the reservoir, and the creation of a fracture propagation model and kinetic Monte Carlo (kMC) models for diverse applications. In the third year, we delved into the fundamental nanostructural properties of DBCs, exploring aspects such as material chemistry, pH tunability, and control of DBC formation and stability. Subsequently, in the extension year, we conducted a systematic investigation of various building blocks containing primary, secondary, and tertiary amine functional groups to understand their impact on rheological and viscoelastic properties. Furthermore, we explored a Dissipative Particle Dynamics (DPD) model to simulate self-assembly processes with precision, creating a high-fidelity representation of relevant nanostructures. The tasks performed this year with the significant results obtained have been discussed in Section 2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface Treatment Strategies for Mitigating Gas Hydrate & Asphaltene Formation, Growth, and Deposition in Flowloops

Abstract Numerous solids including gas hydrates, waxes, and asphaltenes have the potential to form in the production lines of gas and oil fields. This creates a highly non-ideal scenario as the accumulation of said species leads to flow assurance issues, especially with long-term processes like deposition. Since an ever-increasing amount of material is deposited in place at the pipe surface, production stoppage or active mitigation efforts become inevitable. The latter production issues result in increased safety risks and operational expenditures. Therefore, a cost-effective, passive deposition mitigation technology, such as a pipeline coating or surface treatment is especially appealing. The ability to address multiple pipeline flow assurance issues simultaneously without actively disrupting production would represent a dramatic step forward in this area. This study is part of a long-term ongoing effort that evaluates the performance and application of an omniphobic surface treatment for solids deposition prevention in industrially relevant systems. In particular, this specific work concentrates on the efficacy and robustness of the treatment under fully flowing conditions. The apparatuses utilized for this include two flowloops: a lab-scale, high-pressure flowloop for gas hydrate and surface treatment durability studies, and a bench-scale, atmospheric pressure loop for crude oil and asphaltene experiments. Film growth in high-pressure flowloop tests corroborated previous reports of delayed gas hydrate nucleation observed in rocking cells. Without the aid of the memory effect, treated oil-dominated experiments never experienced hydrate formation, spending upwards of a week in the hydrate stability zone (at the subcooled/fluid test conditions). Subsequent tests which utilized the memory effect then revealed that the hydrate formation rate reduced in the presence of the surface treatment compared to a bare stainless-steel surface. This testing was part of a larger set of trials conducted in the flowloop, which lasted about one year. The surface treatment durability under flowing conditions was evaluated during this time. Even after experiencing ∼4000 operating hours and 2 full pressure cycles, no evidence of delamination or damage was detected. Finally, as part of an extension to previous work, corroded surface asphaltene deposition experiments were performed in a bench-top flowloop. Treated experiments displayed an order of magnitude reduction in both total oil (all fractions of crude oil) and asphaltene fraction deposited.

03 NATURAL GAS↗

Novel Membrane-Based Corrosion Sensors For Operating In Natural Gas Pipelines

Membrane-based electrochemical sensors (MBES) provide an attractive option for real-time continuous humidity and corrosion rate measurements inside of natural gas pipelines. The MBES, can use electrochemical techniques such as linear polarization resistance and electrochemical impedance spectroscopy even when a conductive aqueous phase is intermittent or unavailable. We now present field-test performance data of our MBES operated inside a multiphase water and natural gas flow facility. The MBES measured internal corrosion and conductivity at the top, bottom, and side of the pipe spool. Tests were carried out with flow rates of 4.6, 9.1, and 18.3 m/s, temperatures of 21, 29, and 35 °C, and a pressure of 1000 psia. All sensors followed similar trends in open circuit potential, corrosion rate, and conductivity over time. Neither flow rate, temperature, nor build-up of metal-based solids on the sensor surfaces impacted the quality of the electrochemical measurements. The field-test results confirm that the membrane-based electrochemical sensors are suitable for monitoring internal corrosion of operational natural-gas pipelines.

Duffy, Timothy↗

Automated Image Segmentation and Processing Pipeline Applied to X–Ray Computed Tomography Studies of Pitting Corrosion in Aluminum Wires

Understanding pitting corrosion is critical, yet its kinetics and morphology remain challenging to study from X-ray computed tomography (XCT) due to manual segmentation barriers. To address this, an automated pipeline leveraging deep learning for efficient large-scale XCT analysis is developed, revealing new corrosion insights. The pipeline enables pit segmentation, 3D reconstruction, statistical characterization, and a topological transformation for visualization. Here, the pipeline is applied to 87 648 XCT images capturing commercial purity aluminum (1100 Al) wire exposed to sodium chloride (NaCl) salt particles over a period of 122 h. The pipeline achieves complete feature extraction and statistical quantification across the entire XCT dataset, leveraging distributed computing environment for high efficiency. Global growth kinetics such as high-level stepwise sigmoidal volume loss patterns and granular individual pit developments are both captured for 36 detected pits. By combining automation, computer vision, and extensive XCT datasets, this research accelerates precise corrosion assessment to enable materials science discoveries at scale.

36 MATERIALS SCIENCE↗

Investigation of the Hydrogen Embrittlement of API 5L Natural Gas Pipeline Steels

Hydrogen ions produced during corrosion or through hydrogen blending into natural gas pipelines can lead to the degradation of ductility of metals used in these transmission pipelines. The effect of hydrogen on the mechanical properties of pipeline steels was studied for three grades of API 5L steels: X56, X65, and X100. These steels are either commonly used in or considered for use in natural gas transmission pipelines which are being considered for use in hydrogen blending. These steels were subjected to constant strain rate tensile testing after charging with electrochemically generated hydrogen. This presentation reports on work to extend the life of the natural gas pipeline network via understanding the effect of hydrogen embrittlement induced by corrosion processes.

Teeter, Lucas↗

Effect of Drying on Corrosion Mitigation of Hanford Transfer Lines

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site. The waste is transferred between the tanks and other assets using the transfer lines spanning throughout the various tank farms at Hanford. The transfer lines consist of a pipe-in-pipe design, small diameter pipes, and are not piggable. Recent inspection data of the transfer lines have shown areas with corrosion on both interior of the encasements and exterior of the primary pipes, with nearly 50 percent wall loss on the primary pipes and nearly 25% wall loss on the encasement pipes due to pitting corrosion. The visual inspections of the transfer lines have shown presence of corrosion products near the pipeline risers and beyond. It has been hypothesized that the corrosion is predominantly due to the high humidity conditions and in some cases is driven by the presence of residual hydrotest water in the encasement and the associated contact with the safety significant primary pipe. Therefore, drying of the transfer lines could lead to corrosion mitigation. Experimental studies are being conducted to understand the effect of environmental conditions, especially, relative humidity and temperature, on transfer line grade carbon steel corrosion and on mitigating corrosion. The experimental conditions are selected based on the seasonal temperature changes, and relative humidity conditions ranging from 30 to 100 percent. The experimental data will be used as guidance for maintaining a dry environment that will help mitigate the transfer-line corrosion caused by the high humidity conditions.

Shukla, Pavan K.↗