Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma focused ion beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Capturing Carbonation: Understanding Kinetic Complexities through a New Era of Electron Microscopy

Cryogenic plasma focused ion beam (PFIB) electron microscopy analysis is applied to visualizing ex situ (surface industrial) and in situ (subsurface geologic) carbonation products, to advance understanding of carbonation kinetics. Ex situ carbonation is investigated using NIST fly ash standard #2689 exposed to aqueous sodium bicarbonate solutions for brief periods of time. In situ carbonation pathways are investigated using volcanic flood basalt samples from Schaef et al. (2010) exposed to aqueous CO 2 solutions by them. The fly ash reaction products at room temperature show small amounts of incipient carbonation, with calcite apparently forming via surface nucleation. Reaction products at 75° C show beginning stages of an iron carbonate phase, e.g., siderite or ankerite, common phases in subsurface carbon sequestration environments. This may suggest an alternative to calcite in carbonation low calcium-bearing fly ashes. Flood basalt carbonation reactions show distinct zonation with high calcium and calcium-magnesium bearing zones alternating with high iron-bearing zones. The calcium-magnesium zones are notable with occurrence of localized pore space. Oscillatory zoning in carbonate minerals is distinctly associated with far-from-equilibrium conditions where local chemical environments fluctuate via a coupling of reaction with transport. The high porosity zones may reflect a precursor phase (e.g., aragonite) with higher molar volume that then “ripens” to the high-Mg calcite phase-plus-porosity. These observations reveal that carbonation can proceed with evolving local chemical environments, formation and disappearance of metastable phases, and evolving reactive surface areas. Together this work shows that future application of cryo-PFIB in carbonation studies would provide advanced understanding of kinetic mechanisms for optimizing industrial-scale and commercial-scale applications.

36 MATERIALS SCIENCE↗

Nanotomography for Quantitative 3D Particle Reconstruction

Particulates are ubiquitous across fuel cycle operations and carry critical information about particle formation, processing, and potential proliferation-related activities. Traditional analytical techniques, including micro-Raman spectroscopy and standard electron microscopy, are often limited in spatial resolution or dimensionality, particularly when used to examine metallic or submicron-scale features. Understanding particle morphology, phase distribution, and internal porosity is essential for constraining formation conditions, thermodynamic environments, and material transport behavior. In this report, we demonstrate the application of plasma focused ion beam nanotomography to reconstruct micron-scale particulates at nanoscale resolution. Using high-resolution backscattered electron imaging and Avizo software, we obtained 3D reconstructions that enabled quantitative analysis of particle morphology, phase composition, and internal voids. Representative examples include a Ta particle with a large central void and a composite particle with embedded tetrahedral crystalline structures. These reconstructions reveal structural and compositional details that are inaccessible through conventional 2D imaging. The results demonstrate that nanotomography provides both qualitative and quantitative insights into particle formation and behavior. Using nanotomography, porosity and phase distributions can be quantified to inform models of particle density, transport, and solidification conditions. Beyond technical insights, the workflow developed here establishes a transferable capability for analyzing heterogeneous particles and has potential applications in bulk materials studies via x-ray computed tomography or other volumetric imaging modalities. Ongoing efforts are focused on optimizing the workflow to process multiple particles simultaneously, increasing throughput and statistical robustness. Overall, this work illustrates the power of nanotomography as a tool for connecting particulate morphology to formation mechanisms, composition, and transport, thereby strengthening analytical capabilities for nuclear forensics, fuel cycle analysis, and related scientific investigations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiscale Cryo Electron Microscopy Reveals Interfacial Degradation and Stabilization in Battery Electrodes

Electrochemical interfaces are dynamic systems, evolving based on their local environment and reactant surface structures. The electrode-electrolyte interface in Li-ion batteries can be protective, limiting parasitic reactions with the electrolyte to passivate the surface [1]. Additionally, this interphase has an impact on the Li-ion transport through that layer based on its composition, bonding environment, and thickness. These parameters are challenging to collect and may vary depending on the electrode surface site investigated relative to its spatial position in a coin cell. This study will detail a multiscale cryogenic electron microscopy approach where millimeter-scale cross-sections through the coin cell batteries were made using a cryogenic stage within a fs-laser plasma focused ion beam (laser PFIB) with complementary energy dispersive X-ray spectroscopy able to detect variations in the composition at electrode interfaces [2]. Microscale cross-sectioning and lamella sample preparation of battery electrodes was conducted at the Center for Integrated Nanotechnologies using a Ga-ion focused ion beam (FIB) with air-free and cryo-transfer [3], followed by nanoscale mapping of composition and bonding within the CEI through cryo-scanning transmission electron microscopy (cryo-STEM) electron energy loss spectroscopy [4]. This multiscale approach enabled identification of millimeter-scale features of a battery stack with visualization of degradation in electrodes such as cracks in cathode particles, gas evolution, and SEI evolution; microscale interfacial characteristics, such as heterogeneity in the SEI or barrier layer and identification of electrolyte networks to the electrode surfaces; and nanoscale measurement of the CEI thickness, mapping of transition metal bonding within the cathode particles to identify loss of active materials, and identification of beneficial electrolyte additives incorporated into the CEI structure. This multiscale approach allows for a statistical understanding of the primary mechanisms and parasitic degradation pathways that impact performance by limiting the ion transport pathways within Li+ batteries.

36 MATERIALS SCIENCE↗

High-Throughput Ion Irradiation and Microstructural Characterization of Multi-Principal-Element Alloys

Multi-principal-element alloys (MPEAs) have garnered interest in the nuclear community for their apparent resistance to microstructural damage under irradiation. While both experimentation and simulation have demonstrated reduced hardening and void swelling in MPEAs, the relationship between composition and irradiation response is still poorly understood since a rich experimental database for MPEAs does not yet exist. In this work, to accelerate the generation of experimental irradiation-response data for MPEAs, high-throughput synthesis, irradiation, and characterization techniques have been employed. Specifically, additive manufacturing has been used to produce arrays of various MPEAs (1-cm2 coupons), which have been subsequently irradiated using 4-MeV Ni2+ ions to a peak damage of 200 dpa at 500 °C. Hardening and void swelling have been assessed using nanoindentation and trenching via plasma focused ion beam (PFIB), respectively. Trends in the experimental data relating hardening and void swelling behavior to composition have been analyzed using different machine learning approaches.

36 MATERIALS SCIENCE↗

Super-strong magnetic field-dominated ion beam dynamics in focusing plasma devices

High energy density physics is the field of physics dedicated to the study of matter and plasmas in extreme conditions of temperature, densities and pressures. It encompasses multiple disciplines such as material science, planetary science, laboratory and astrophysical plasma science. For the latter, high energy density states can be accompanied by extreme radiation environments and super-strong magnetic fields. The creation of high energy density states in the laboratory consists in concentrating/depositing large amounts of energy in a reduced mass, typically solid material sample or dense plasma, over a time shorter than the typical timescales of heat conduction and hydrodynamic expansion. Laser-generated, high current–density ion beams constitute an important tool for the creation of high energy density states in the laboratory. Focusing plasma devices, such as cone-targets are necessary in order to focus and direct these intense beams towards the heating sample or dense plasma, while protecting the proton generation foil from the harsh environments typical of an integrated high-power laser experiment. A full understanding of the ion beam dynamics in focusing devices is therefore necessary in order to properly design and interpret the numerous experiments in the field. In this work, we report a detailed investigation of large-scale, kilojoule-class laser-generated ion beam dynamics in focusing devices and we demonstrate that high-brilliance ion beams compress magnetic fields to amplitudes exceeding tens of kilo-Tesla, which in turn play a dominant role in the focusing process, resulting either in a worsening or enhancement of focusing capabilities depending on the target geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion-beam focusing in a double-plasma device

The authors studied the propagation of a low-energy charge-neutralized ion beam injected into the target region of a long double-plasma device. A magnetic field of up to about 180 G may be applied along the axis of the device. As a result of charge exchange collisions, the ion beam is attenuated as it propagates into the target region. However, under certain conditions of magnetic field strength and neutral gas pressure, the authors have observed a `reemergence' of the beam on axis far downstream in the target. This reemergence of the ion beam is attributed to a focusing of the ions by a self-consistently produced radial ambipolar electric field. The effect may be expected to occur in other types of plasma devices as well, whenever a sufficiently large radially inward electric field is present.

Johnson, James C.↗

Deciphering the influence of high-flux helium plasma exposure on tungsten nanostructure growth using real-time, in situ spectroscopic ellipsometry

In situ analysis of surfaces during high-flux plasma exposure represents a long-standing challenge in the study of plasma–material interactions. While post-mortem microscopy can provide a detailed picture of structural and compositional changes, in situ techniques can capture the dynamic evolution of the surface. In this study, we demonstrate how spectroscopic ellipsometry can be applied to the real-time characterization of W nanostructure (also known as “fuzz”) growth during exposure to low temperature, high-flux He plasmas. Strikingly, over a wide range of sample temperatures and helium fluences, the measured ellipsometric parameters (Ψ,Δ) collapse onto a single curve that can be directly correlated with surface morphologies characterized by ex situ helium ion microscopy. The initial variation in the (Ψ,Δ) parameters appears to be governed by small changes in surface roughness (<50 nm) produced by helium bubble nucleation and growth, followed by the emergence of 50 nm diameter W tendrils. This basic behavior appears to be reproducible over a wide parameter space, indicating that the spectroscopic ellipsometry may be of general practical use as a diagnostic to study surface morphologies produced by high-flux He implantation in refractory metals. An advantage of the methods outlined here is that they are applicable at low incident ion energies, even below the sputtering threshold. As an example of this application, we apply in situ ellipsometry to examine how W fuzz growth is affected both by varying ion energy and the temperature of the surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lithium Growth on Alloying Substrates and Effect on Volumetric Expansion

The widespread implementation of next-generation Li metal anodes is limited, in part, due to the formation of dendritic and/or mossy electrodeposits during cycling. These morphologies can lead to battery failure due to the formation of short circuits and significant volumetric expansion at the anode. One strategy to control the electrodeposition of Li metal is to use lithiophilic materials at the anode. Here, we evaluate the impact of Ag and Au on the early stages of Li metal electrodeposition and cycling. The alloying substrates decrease the voltage for Li reduction and improve Li wetting/adhesion. We probe volumetric expansion directly through dilatometry measurements and find that the degree of volumetric expansion is less when lithium is cycled on an alloying substrate compared to a non-alloying substrate (Cu). Dilatometry experiments reveal that Au has the least amount of volumetric expansion and coin cell cycling experiments indicate that Ag yields more stable cycling compared to Au or Cu. The evaluation of in situ cross-sectional images of cycled coin cells shows that Ag has the lowest volumetric expansion in a coin cell format.

alloys↗

Using Xe Plasma FIB for High-Quality TEM Sample Preparation

Here, a direct comparison between electron transparent transmission electron microscope (TEM) samples prepared with gallium (Ga) and xenon (Xe) focused ion beams (FIBs) is performed to determine if equivalent quality samples can be prepared with both ion species. We prepared samples using Ga FIB and Xe plasma focused ion beam (PFIB) while altering a variety of different deposition and milling parameters. The samples’ final thicknesses were evaluated using STEM-EELS $\textit{t/λ}$ data. Using the Ga FIB sample as a standard, we compared the Xe PFIB samples to the standard and to each other. We show that although the Xe PFIB sample preparation technique is quite different from the Ga FIB technique, it is possible to produce high-quality, large area TEM samples with Xe PFIB. We also describe best practices for a Xe PFIB TEM sample preparation workflow to enable consistent success for any thoughtful FIB operator. For Xe PFIB, we show that a decision must be made between the ultimate sample thickness and the size of the electron transparent region.

47 OTHER INSTRUMENTATION↗

Final Technical Report - Rapid Surface Microanalysis using a Low Temperature Plasma

This project focused on improving our current understanding and scientific knowledge in the area of plasma-surface interactions and plasma assisted material synthesis related to advanced microelectronics and nanotechnology. Current challenges include: controlling the interaction of Low Temperature Plasma (LTP) with a single layer of atoms to manufacture integrated circuits, continued miniaturization of integrated circuits, LTP processing of material surfaces and thin films to enable industrial scale fabrication of advanced microelectronics, synthesis of new materials, nanomaterials, nanotubes, and complex materials, Technology developed in this subtopic is of value to either (i) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at high resolution (micron or sub-micron resolution) rapidly (hours or days rather than years to complete a high-resolution scan of such a large surface area), or (ii) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at relatively low resolution rapidly, then apply algorithms to select spots for micron-scale imaging. Sputtering occurs when particles of a solid material are ejected from its surface by energetic particles from a plasma. While the degradation of the solid material and the subsequent deposition of the ejected material onto vulnerable surfaces are the usual subjects of sputtering studies, plasma science has yet to be combined with sputtering to create new diagnostics devices and systems. Small changes in the design of the plasma discharge device make it possible to create broad plasma beams for rapid scanning or small plasma beams to obtain the distribution of ejected elements with micron resolution. In the high-resolution use, the ion flux is extracted from the gas-discharge plasma and focused by a spherical emission surface to micron sizes onto the target specimen, providing very local sputtering and local elemental analysis. We call this “self-focusing”. The radiation from the excited and ionized sputtered atoms is recorded by a spectrometer through a window and fiberglass cable and analyzed with standard software packages used for optical glow discharge spectroscopy. Computer simulations of beam formation were used to verify and optimize the designs to be tested. A prototype was designed, constructed, and used to start experiments of beam formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the role of self-generated magnetic fields in focused ion beams driven by intense picosecond laser pulses

We investigate the physics of ion beam focusing in the interaction of intense picosecond laser pulses with concave foils, using two-dimensional particle-in-cell simulations. Curved targets have been observed to deliver brighter multi-MeV ion beams than flat targets, and they could be used to ignite pre-compressed ICF fusion capsules in a scheme called ion fast ignition. Focusing is achieved by shaping the target and relying on an ion acceleration mechanism in which the ions are accelerated normal to the target surface; subsequently, the plasma expansion grows magnetic fields that advect with the plasma and deflect ions away from the target symmetry axis, causing the focal spot to shift downstream from its geometric location. The drop in both electric and magnetic field strengths in the expanding plasma makes the ion beam envelope asymmetric with respect to the focusing plane.

Focused ion beam↗

Emittance preservation for the electron arm in a single PWFA-LC stage using quasi-adiabatic plasma density ramp matching sections

Plasma-based acceleration (PBA) is being considered for a next generation linear collider (LC). In some PBA-LC designs for the electron arm, the extreme beam parameters are expected to trigger background ion motion within the witness beam, which can lead to longitudinally varying nonlinear focusing forces and result in an unacceptable emittance growth of the beam. To mitigate this, we propose to use quasi-adiabatic plasma density ramps as matching sections at the entrance and exit of each stage. We match the witness electron beam to the low density plasma entrance, where the beam initially has a large matched spot size so the ion motion effects are relatively small. As the beam propagates in the plasma density upramp, it is quasi-adiabatically focused, and its distribution maintains a non-Gaussian equilibrium distribution in each longitudinal slice throughout the process, even when severe ion collapse has occurred. This only causes small amounts of slice emittance growth. The phase mixing between slices with different betatron frequencies leads to additional projected emittance growth within the acceleration stage. A density downramp at the exit of an acceleration section can eliminate much of the slice and projected emittance growth as the beam and ion motion adiabatically defocuses and decreases, respectively. Simulation results from QuickPIC with Azimuthal Decomposition show that within a single acceleration stage with a 25 GeV energy gain, this concept can limit the projected emittance growth to only ∼2% for a 25 GeV, 100 nm emittance witness beam and ∼20% for a 100 GeV, 100 nm normalized emittance witness beam. The trade-off between the adiabaticity of the plasma density ramp and the initial ion motion at the entrance for a given length of the plasma density ramp is also discussed.

Physics↗

Conceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator

This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.

47 OTHER INSTRUMENTATION↗

Beam dynamics challenges in linear colliders based on laser-plasma accelerators

In this paper we discuss design considerations and beam dynamics challenges associated with laser-driven plasma-based accelerators as applied to multi-TeV-scale linear colliders. Plasma accelerators provide ultra-high gradients and ultra-short bunches, offering the potential for compact linacs and reduced power requirements. We show that stable, efficient acceleration with beam quality preservation is possible in the nonlinear bubble regime of laser-plasma accelerators using beam shaping. Ion motion, naturally occuring for dense beams (i.e., low emittance and high energy) severely damps transverse beam instabilities. Coulomb scattering by the background ions is considered and it is shown that the strong focusing in the plasma strongly suppresses scattering-induced emittance growth. Finally, Betatron radiation emission from the transverse motion of the beam in the plasma will result in beam power loss and energy spread growth; however for sub-100 nm emittances, the beam power loss and energy spread growth will be sub-percent for multi-TeV-class plasma linacs.

47 OTHER INSTRUMENTATION↗

Positron acceleration in plasma wakefields

Plasma acceleration has emerged as a promising technology for future particle accelerators, particularly linear colliders. Significant progress has been made in recent decades toward high-efficiency and high-quality acceleration of electrons in plasmas. However, this progress does not generalize to the acceleration of positrons, as plasmas are inherently charge asymmetric. Here, we present a comprehensive review of historical and current efforts to accelerate positrons using plasma wakefields. Proposed schemes that aim to increase energy efficiency and beam quality are summarized and quantitatively compared. A dimensionless metric that scales with the luminosity-per-beam power is introduced, indicating that positron-acceleration schemes are currently below the ultimate requirement for colliders. The primary issue is electron motion; the high mobility of plasma electrons compared to plasma ions, which leads to nonuniform accelerating and focusing fields that degrade the beam quality of the positron bunch, particularly for high efficiency acceleration. Finally, we discuss possible mitigation strategies and directions for future research.

43 PARTICLE ACCELERATORS↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗

Focused Ion Beam analysis of non radioactive samples [PowerPoint]

The presentation includes various images to illustrate the analysis. Helios G4 Plasma FIB: Xe ion columns mills material 30 times faster than Ga; Options include: Energy Dispersive Spectroscopy (EDS), Wavelength Dispersive spectroscopy (WDS) Electron backscattered Diffraction (EBSD), Time of Flight Sims (ToF SIMS), Inert gas/vacuum sample transfer system; Excels at micromachining and collecting 3D datasets using various detection systems.

42 ENGINEERING↗

Ion beams from laser-generated plasmas

The paper describes the space-charge-limited beams produced by the plasma blowoffs generated by 20-MW bursts of 1.06-micron radiation from an active Q-switched Nd:YAG laser. Laser power densities near 10 to the 11th/sq cm on solid targets generate thermalized plasma plumes which drift to a 15-kV gridded extraction gap where the ions are extracted, accelerated, and electrostatically focused; the spatially defined ion beams are then magnetically analyzed to determine the charge state content in the beams formed from carbon, aluminum, copper, and lead targets. This technique preserves time-of-flight (TOF) information in the plasma drift region, which permits plasma ion temperatures and mass flow velocities to be determined from the Maxwellian ion curve TOF shapes for the individual charge species.

Hughes, R. H.↗