Search NASA⌕ Search

SEARCH · Search NASA

Results for “power reference frames”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Definition of the IEA Wind 22-Megawatt Offshore Reference Wind Turbine

This technical report describes the design of a new 22 Megawatt reference wind turbine (RWT). The turbine model was designed collaboratively by two teams at the Denmark Technical University and at the National Renewable Energy Laboratory within the International Energy Agency (IEA) Wind Technology Commercialization Programme (TCP) Task 55 on Reference Wind Turbines and Farms. RWTs serve an important purpose in the wind energy community, since they provide openly available data for models representative of current wind turbine technology, which can be used by practitioners for a variety of modeling purposes, ranging from aerodynamic, structural, and aeroelastic turbine modeling to wind farm flow modeling, across a range of fidelities. The IEA 22 RWT aims to model machines with projected installation in the 2025-2030 time frame. The turbine has a rotor diameter of 284 meters and a hub height of 170 meters. It is a class 1-B machine with a rotor specific power nearing 350 W m -2 and it is mounted on either a fixed-bottom offshore foundation or a semi-submersible floating platform.

17 WIND ENERGY↗

A Voltage Injection-Based Current Harmonics Suppression Strategy for Six-Phase PMSM With Nonsinusoidal Back EMF

This article presents a voltage injection-based current harmonic minimization method for wide bandgap device-based six-phase permanent magnet synchronous machine (PMSM) drives. The presence of low-order harmonics is common in the back EMF of PMSMs with low slot and high pole numbers. The back EMF harmonics generate low-order harmonic currents that increase torque ripples. Furthermore, zero-sequence current (ZSC) is also observed if all six phases are connected to a common neutral point. ZSC does not affect the torque ripple but reduces the system efficiency. A special technique is required to reduce ZSC for variable speed drives as direct ac component to synchronous reference frame (SRF) dc transformation is not possible for ZSC. In this article, a voltage injection-based current harmonics reduction method is proposed. The injected harmonic voltage coefficients are calculated from the harmonic estimations of back EMF and updated using closed-loop harmonic compensators to improve steady-state performance. For ZSC reduction, third harmonics power controller, and for 6n ± 1 (n = 1, 2,...) order harmonic current reduction, SRF current controllers are presented in this article. Furthermore, the current harmonics minimization method is experimentally verified using a GaN-based three-level active neutral point clamped inverter-driven six-phase PMSM.

42 ENGINEERING↗

A Novel Grid-forming Voltage Control Strategy for Supplying Unbalanced Microgrid Loads Using Inverter-based Resources

This paper presents a novel grid-forming voltage control strategy for a battery energy storage system to maintain balanced three-phase output voltages when serving unbalanced loads. A stationary reference frame (αβ) based control scheme is proposed to regulate positive-sequence and negative-sequence voltages. Compared with the conventional rotating reference frame (dq) based control scheme, the proposed scheme shows better dynamic performance. Then, we analyze the system zero-sequence network and propose adding a grounding transformer to the Y/Yg connected output transformer to further reduce the voltage unbalance at the point of common coupling. The simulation results demonstrate the effective performance of the proposed voltage control scheme. Based on the results, the power-voltage unbalance curve is derived for different output transformer configurations to establish the relationship between the power unbalance limit and the voltage unbalance limit for microgrid power scheduling.

Xu, Bei↗

Demonstration of ACCERT Software for Nuclear Power Plant Techno-Economics

In the past few years, there has been a renewed interest in the deployment of nuclear power for decarbonizing the electricity grid as well as a range of industrial applications. As the demonstrations of advanced nuclear power plants start to begin, there will likely be a further increase in this interest. As nuclear is being considered as a part of the energy mix, understanding the cost of nuclear energy becomes increasingly important for all stakeholders including advanced reactor vendors (for making design decisions and marketing their designs), users of nuclear energy (e.g., to estimate the cost of decarbonization of other industries using nuclear), and government (e.g., in capacity expansion models that are used in framing policy). In this summary, we demonstrate a software tool called ACCERT that is currently being developed with funding from the Systems Analysis and Integration (SA&I) program under the Department of Energy’s Office of Nuclear Energy (DOE NE). ACCERT is a cost estimation and techno-economics tool for nuclear power plant applications that includes a database of (a) cost estimates of various ‘reference’ nuclear power plant designs gathered from existing literature, and (b) algorithms developed from these costs that can be used extrapolate the existing costs and perform a bottom-up cost estimation of other designs. A companion summary describes the software and its design in more detail and this summary presents a demonstration for four different nuclear power plant designs: a pressurized water reactor (PWR), high-temperature gas reactor (HTGR), sodium fast reactor (SFR), and a heat-pipe microreactor. The demonstrations include the reference cost estimates and the cost estimates of a modified design for each reference case.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Autonomous Navigation and Control of UGVs' in Nuclear Power Plants - 20381

The purpose of the husky A200 ground robot is to autonomously navigate through the places where it is very hazardous for human beings to reach and operate, like nuclear power plants, chemical industries. The aim is to navigate the ground robot autonomously with an Arm mounted on the robot along with the different sensors as camera, and Lidar. The autonomous motion of the robot is controlled by the controller which uses path planner for trajectory generation of the robot. The mission planner uses the current position of the husky A200, given the way points of the initial and the destination it would extract a best possible route based on the current events provided using GMapping. The global reference frame is used for planning the way points. Creating the appropriate path and the actions required to follow the path are given by the motion planner. The motion planner depends on the active sensor data such as obstacles, lanes, based on the sensor data feasible path is generated. Feasibility of the path is determined by the dynamics of the husky and a series of points generated with certain velocity and acceleration profile. The controller adjusts the lateral, longitudinal and yaw motion of the husky to command the behaviors. The kinematic model is developed for kinematic motion of the husky and the dynamic model is developed for transient and steady state characteristics. The images and other type of data captured by the camera are processed through the computational framework used to build machine learning models. TensorFlow will be used for deep learning and to identify and classify different objects around the husky. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Load Inrush Current Mitigation in Islanded Microgrids Powered by Grid-Forming Inverters

Grid-forming inverters in a microgrid may trip due to high inrush current caused by a switched connection of an inductive load, e.g., a relatively large induction motor. The control scheme presented in this article includes virtual inertia control method superimposed on the cascaded controller. This article studies the impact of cascaded control scheme used for grid-forming inverter to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. Experimental tests are performed using the virtual inertia method for generating the reference angle for synchronous frame conversion. The experimental performance and sensitivity of the controller to different controller gain settings for a switched connection of an induction motor are discussed. The cascaded operation significantly mitigates the inrush currents while the inverters can perform a normal operation. The performance of the control method is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented.

Gursoy, Mehmetcan↗

Finite deformation implementation of a mixed-mode single-integral type cohesive zone with reorienting surfaces of separation

To model material ductile failure and crack propagation, cohesive zone elements can be embedded along potential fracture paths in a finite element simulation. When damage criteria are met, elements in the mesh decohere, simulating the formation and propagation of a crack. In this paper, we present a novel computational algorithm based on finite deformation theory, essential to modeling crack initiation and growth in solids undergoing large deformations. This new algorithm was formulated within a Lagrangian frame of reference to extend previous cohesive zone algorithms to include modeling crack growth in finite deformation contexts. The local coordinate system, necessary for defining an embedded cohesive zone, is constructed based upon the current configuration and is updated within the nonlinear iteration process, thereby resulting in the convergence of the solution for a growing crack in a large deformation quasi-static setting. The model’s accuracy was demonstrated by comparing finite element model simulation results with the analytic case of a constant surface separation, as shown in the verification examples. The power and efficacy of the algorithm to capture large deformations during crack growth were then demonstrated with a double cantilever beam example case. It indicates that the model can be applied to a variety of physical circumstances for predicting crack initiation and growth with delamination and fracture.

42 ENGINEERING↗

Enabling Grid-Forming Control Under Unbalanced Conditions

Standalone microgrids often experience unbalanced loading and faults, which can cause grid-forming control designed for balanced conditions to produce oscillatory responses. To address this issue, a compact time-domain transformation appropriate for inverter control is proposed, allowing the conversion of unbalanced three-phase signals to positive and negative synchronous reference frames. This transformation supports the development of a grid-forming control with fault ride-through, featuring frequency and voltage droop controllers and nested current and voltage control loops that seamlessly integrate an enhanced current limiter. The effectiveness of the proposed control and transformation is demonstrated through analytical results and electromagnetic transient simulation.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Low-Frequency Stability Analysis of Inverter-Based Islanded Multiple-Bus AC Microgrids Based on Terminal Characteristics

For system planning of three-phase inverter-based islanded ac microgrids, the low frequency instability issue caused by interactions of inverter droop controllers is a major concern. When internal control information of procured commercial inverters is unknown, impedance-based small-signal stability criteria facilitate prediction of resonances in medium and high frequency ranges, but they usually assume the grid fundamental frequency as constant and thus they are incapable of analyzing the low-frequency oscillation of the fundamental frequency in islanded microgrids. Aiming at solving this issue, this paper proposes two stability analysis methods based on terminal characteristics of inverters and passive connection network including the dynamics of the fundamental frequency for analysis of low-frequency stability in islanded multiple-bus microgrids. Based on the Component Connection Method (CCM) to systematically separate inverters from the passive connection network, a general approach is developed to model the microgrid as a multiple-input-multiple-output (MIMO) negative feedback system in the common system d-q reference frame. By applying the generalized Nyquist stability criterion (GNC) to the return-ratio and return-difference matrices of the MIMO system model, the low-frequency stability related to the fundamental frequency can be analyzed using the measured terminal characteristics of inverters. Finally, analysis and simulation of a 37-bus microgrid verify the effectiveness of the proposed stability analysis methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Non-Cooperative Game-Based Distributed Beam Scheduling Framework for 5G Millimeter-Wave Cellular Networks

Here, this paper studies the problem of distributed beam scheduling for 5G millimeter-Wave (mm-Wave) cellular networks where base stations (BSs) belonging to different operators share the same spectrum without centralized coordination among them. Our goal is to design efficient distributed scheduling algorithms to maximize the network utility, which is a function of the achieved throughput by the user equipment (UEs), subject to the average and instantaneous power consumption constraints of the BSs. We propose a Media Access Control (MAC) and a power allocation/adaptation mechanism utilizing the Lyapunov stochastic optimization framework and non-cooperative games. In particular, we first decompose the original utility maximization problem into two sub-optimization problems for each time frame, which are a convex optimization problem and a non-convex optimization problem, respectively. By formulating the distributed scheduling problem as a non-cooperative game where each BS is a player attempting to optimize its own utility, we provide a distributed solution to the non-convex sub-optimization problem via finding the Nash Equilibrium (NE) of the game whose weights are determined optimally by the Lyapunov optimization framework. Finally, we conduct simulation under various network settings to show the effectiveness of the proposed game-based beam scheduling algorithm in comparison to that of several reference schemes.

42 ENGINEERING↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗

On the effect of scalar flux weighing of linearly anisotropic scattering matrices in few-group transport calculations

The majority of the codes available for homogenized group constant generation for deterministic transport calculations apply the approximation of scalar flux weighting during energy group condensation of higher-order anisotropic scattering matrices. In this paper, we discuss the effect of scalar flux weighting of the linearly anisotropic scattering matrices in the frame of S P{sub 3} and S{sub 12} calculations performed for a two-dimensional VVER-440 reactor benchmark. To compare group constants generated for two neutron energy groups, an infinite pin cell was homogenized with Serpent 2 and ERANOS ECCO. Serpent 2 applies scalar flux, while ERANOS ECCO performs current weighting of the linearly anisotropic scattering matrices during energy group condensation. For analyzing the effect of the various weighting options, three simple reactor models were built assuming different core sizes using standard rectangular assemblies with 15*15 fuel pins. Diffusion, SP{sub 3} and S{sub 12} calculations were performed for the 3 models using group constants generated with Serpent 2 and ERANOS ECCO. The effect of scalar flux weighting of linearly anisotropic scattering matrices is shown by comparing the decrease in reactivity due to the decreased reactor size, as well as the assembly power distribution to reference results obtained with Serpent 2 Monte Carlo calculations. Neglecting higher than linearly anisotropic scattering and indirect application of diffusion coefficients in higher-order transport calculations is advised if angular flux-moment spectra weighted higher-order scattering matrices cannot be generated. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Circulating Current Reduction of Back-to-Back MMC with Advanced Grid-Support Functionalities for Medium-Voltage Applications

A Lyapunov energy function based circulating current reduction scheme for a back to back modular multilevel converter based system for a microgrid application has been proposed in this digest. In order to ensure no circulating or zero sequence currents within the modules, the dynamics from one leg of the converter to the other are evaluated. A Lyapunov energy function is then developed and utilizing the circulating current dynamics of the converter the overall control law is implemented. In this digest a decentralized hierarchical control architecture has been implemented for the main current control; where the outer loop or the central controller implements the higher level grid interconnection functions as per IEEE 1547-2018 standards and the inner loop based on synchronous reference frame implements the current control architecture. The inner loops' outputs are the commanded converter voltages either on either side which are augmented by the Lyapunov energy function based circulating current suppression architecture. To evaluate the efficacy of the overall system, the overall system is modeled around a 300kVA back to back SiC multilevel modular converter used as a direct-connected medium voltage (MV) grid intertie based on MATLAB/Simulink domain. Several important case studies are presented in this paper to prove the effectiveness of the proposed architecture. case study results are presented.

circulating current↗

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters↗

High Flux Isotope Reactor Low-Enriched Uranium Low Density Silicide Fuel Design Parameters

High Flux Isotope Reactor (HFIR) highly enriched uranium (HEU) to low-enriched uranium (LEU) conversion activities are ongoing as part of the Department of Energy (DOE) National Nuclear Security Administration (NNSA)’s nuclear nonproliferation mission. Design activities studying the conversion of HFIR from HEU to LEU fuel explored different fuel design features and shapes with a low density uranium-silicide dispersion (U 3 Si 2 -Al) fuel, which has a uranium density of 4.8 gU/cm 3 . The goal of these studies is to generate several HFIR LEU fuel designs of varying fuel fabrication complexity that meet the current HEU performance metrics and safety requirements. The documented designs will serve as references for fuel fabrication and qualification activities. Recent advancements in modeling and simulation tools enable quick prototyping of fuel designs. Shift, a Monte Carlo neutron transport and depletion tool optimized for high-performance computing (HPC) architectures, is used for efficient fuel cycle and performance metrics calculations. The HFIR Steady State Heat Transfer Code (HSSHTC) is used to vet the thermal safety margin. Also, a new automation tool that connects all fuel design analysis steps, named Python HFIR Analysis and Measurement Engine (PHAME), has been developed to expedite the design study in an efficient and reproducible manner. Leveraging these tools, several candidate fuel designs were selected for varying fabrication complexity. This report provides design feature details for four selected HFIR LEU low density U 3 Si 2 -Al fuel designs and their corresponding performance and safety metrics. Nominal, best-estimate design parameters and irradiation conditions, including fission rate densities, power densities, heat fluxes, and cumulative fission densities are provided for candidate fuel designs relevant to framing irradiation experiments to support fuel qualification efforts. Simulations show that the low density U 3 Si 2 -Al, with design features to enhance safety, can meet HEU core performance metrics and safety requirements if the reactor power is increased from 85 MW (HEU) to 95 MW (LEU) and if the active fuel length is increased from 50.80 cm (HEU) to 55.88 cm (LEU).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A buoyancy–shear–drag-based turbulence model for Rayleigh–Taylor, reshocked Richtmyer–Meshkov, and Kelvin–Helmholtz mixing

A phenomenological turbulence model for Rayleigh–Taylor, reshocked Richtmyer–Meshkov, and Kelvin–Helmholtz instability-induced mixing is developed using a general buoyancy–shear–drag model. Analytic solutions to the simplified model equations corresponding to each instability are derived separately, which are then used to calibrate the model coefficients to predict specific values of the mixing layer growth parameters and exponents. The buoyancy-shear–drag equations for the bubble and spike mixing layer widths are then solved numerically, and a turbulent diffusivity (or viscosity) is constructed dimensionally as the product of the mixing layer width, h, and its time-derivative, dh/dt. Surrogate turbulent fields are then constructed by multiplying a presumed, approximate self-similar spatial profile by appropriate functions of h and dh/dt. Using several simplifying approximations, the turbulent diffusion equations satisfied by the mean mass fraction and mean shear velocity are solved analytically in a reference frame moving with the mean advection velocity, and it is shown that the mean fields evolve in space and time as expected. The explicit modeling and solution of turbulent transport equations (e.g., for the turbulent kinetic energy and its dissipation rate or a lengthscale) are not required. By using separate equations for the bubble and spike evolution, the model naturally captures the asymmetry induced by an increasing density contrast between the heavy and light fluids. The model also includes molecular dissipation and diffusion, and therefore, can describe transition to fully-developed turbulence if the initial turbulent diffusivity/viscosity is much smaller than the molecular diffusivity/viscosity. This model is applied to constant-acceleration Rayleigh–Taylor, impulsively reshocked Richtmyer–Meshkov, and variable-density Kelvin–Helmholtz mixing layers to demonstrate its utility. It is shown that the numerical solutions of the model calibrated using specific values of the instability growth parameters and exponents: (1) produces mixing layer widths in agreement with the expected self-similar growth power laws; (2) gives spatiotemporal profiles of turbulent fields that are expected and consistent with previous results; (3) predicts the expected power-law growths and decays of the spatially-integrated turbulent fields, and; (4) gives spatiotemporal profiles of the mean fields that are expected and consistent with previous results. This relatively simple model can be implemented numerically, and is expected to be useful for fundamental as well as astrophysical and inertial confinement fusion applications.

42 ENGINEERING↗

Solar Radiation Research Laboratory (SRRL) Core Project Final Report: Fiscal Years 2022-2024

The Solar Radiation Research Laboratory (SRRL) at the National Laboratory of the Rockies (NLR) is a world-leading solar calibration and measurement facility and maintains and disseminates the World Radiation Reference (essentially the W/m2) for the United States that is essential for traceable and accurate measurements of solar radiation at all solar generation facilities. SRRL operates two calibration facilities that meet International Standards Organization-17025 (ISO-17025) standards and provide unique high-quality calibrations to NREL and other U.S. Department of Energy laboratories. The Baseline Measurement System (BMS) at SRRL provides a high-quality record of solar irradiance and surface meteorological conditions. SRRL capabilities are used to develop (1) improved methods for the calibration of solar radiometers; (2) new standards through the ISO, the International Electrotechnical Commission (IEC), and the American Standards for Testing of Materials (ASTM) International; (c) solar radiation and meteorological models; and (d) advanced instrumentation and methods for operating solar measurement stations. The SRRL datasets are also critical for the validation of new models and datasets, such as the National Solar Radiation Database (NSRDB). The research and development of solar radiation measurement systems and resource modeling techniques are essential for advancing the scientific basis for producing reliable resource data. Specifically, the spatial, temporal, and spectral (wavelength dependency) characteristics of the solar resource are required in several different time frames for various project phases.

14 SOLAR ENERGY↗

Simulation of CEFR neutronic start-up tests with FENNECS

This paper presents simulation results of selected Neutronic Start-up Tests of the China Experimental Fast Reactor (CEFR) obtained by the neutronics code FENNECS that have been performed within the frame of the IAEA Coordinated Research Program I31032. The Finite Element Neutronics code FENNECS is developed at GRS and solves the few-group steady-state and transient diffusion equation using a Galerkin-based finite element approach. Its main purpose is the safety assessment of Small Modular Reactors and Micro Reactors with complex geometry (e.g., rotating control drums) which gain increased interest internationally. Serpent has been applied to create reference models of the CEFR and cross-section libraries in 10 energy groups for FENNECS. Using these libraries, the following experiments have been simulated with FENNECS: net criticality, control rod integral and differential worth, void reactivity effect, subassembly exchange reactivity effects and reaction rate distribution. The obtained satisfactory agreements with the measurements represent a valuable contribution to the validation of FENNECS. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗