Search NASASearch

SEARCH · Search NASA

Results for “proton-boron fusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

168 records · Page 2

Computational discovery of a tetragonal MBene phase: diamond-shaped boron lattices, viable MAB precursors, and selective CO 2 reduction

MBenes are a class of two-dimensional transition-metal borides derived from layered MAB phases. Here, we use first-principles calculations to predict a new tetragonal MB (1 : 1) MBene phase featuring a diamond-shaped B–B lattice and systematically assess its phase stability, synthetic accessibility, and catalytic performance towards the CO 2 reduction reaction (CO 2 RR). Four tetragonal configurations are benchmarked against known hexagonal and orthorhombic phases, and a multi-tier screening identifies six robust members (CrB, FeB, MoB, WB, IrB, and PtB). Exploration of the I4/mmm MAB space reveals 11 viable precursors, including the experimentally synthesized Ir 2 ZnB 2 , which validates our screening approach. CO 2 RR free-energy diagrams show that CrB favors CH 3 OH while FeB, MoB, WB, IrB, and PtB preferentially yield HCOOH. The corresponding limiting potentials are competitive with, and in some cases superior to, those reported for state-of-the-art orthorhombic and hexagonal MBenes. These findings expand the MBene landscape by establishing a tetragonal phase with structural, synthetic, and catalytic promise.

Lu, Linguo [University of Puerto Rico, San Juan, P

Optimizing Porous Transport Layer Porosity for Proton Exchange Membrane Water Electrolysis

An empirical model is presented that describes anode-side losses related to porous transport layer (PTL) morphology in proton exchange membrane water electrolysis (PEMWE). The model is based on an advanced voltage breakdown analysis that links various overpotentials to PTL morphology. Custom Ti PTLs, spanning uncommonly low porosities (22 - 31%), were fabricated and analyzed with X-ray CT to obtain pore and particle size distributions. Particle size distributions were consistent across samples with an average particle diameter of 12.0?..mu..m, whereas average pore diameters ranged from 6.0 to 7.0?..mu..m. The PTLs were tested in standard PEMWE cell assemblies with anode catalyst loadings of 0.1 mgIr cm-2 to obtain polarization curves, electrochemical impedance spectra, and augmented Tafel analysis. The PTL-dependent anode side losses were deconvoluted and assigned to excess utilization, concentration, ion transport resistance, and electrical contact resistance overpotentials. The data and model reveal an optimal 20 - 28% PTL porosity region where utilization and contact resistance overpotentials are minimized without triggering concentration and ion transport losses related to water deprivation. The optimal PTL porosity depends on the operating current density and is demonstrated at realistic PEMWE water flow rates to establish PTL design guidance for operation at scale.

08 HYDROGEN

Mitigating Hydrogen-Induced Degradation of Iridium Anodes in Proton Exchange Membrane Water Electrolyzers

One promising method for reducing precious metal usage in proton exchange membrane water electrolysis is lowering iridium (Ir) loading at the anode. However, low-loading Ir catalysts often suffer from poor stability under high current densities. In this study, hydrogen (H2) crossover from the cathode to the anode is identified as a key degradation pathway. Temperature-programmed reduction confirms the reduction of IrO2 at 80 °C in a hydrogen environment, highlighting the vulnerability of IrO2-based catalysts to H2 exposure. To mitigate this effect, palladium (Pd) is introduced as an anode additive, acting as an H2 oxidation catalyst and mitigating IrO2 reduction. This protective role is verified by inductively coupled plasma optical emission spectroscopy and in situ X-ray absorption spectroscopy, showing significantly suppressed Ir dissolution at 80 °C under H2 flow when an O-covered Pd surface is present at oxygen evolution reaction potentials. Results from the current study identify a new strategy in improving activity and durability of catalysts in electrolyzers.

58 GEOSCIENCES

Mechanisms of Protonic Nonvolatile Memory Device

A nonvolatile memory device based on protonic transport in oxides has been proposed. The mobile H+ ions are introduced into the SiO2 layer by annealing Si/SiO2/Si structures in H2 at temperatures greater than 500 deg C. This effect has only been observed for confined oxides that have been annealed at greater than or equal to 1100 C prior to the hydrogenation anneal. This includes buried oxides such as Unibond and SIMOX as well as thermal oxides annealed with a polysilicon cap. An applied field moves the charge within the oxide and the charge stops moving when the field is removed. In a memory device, the hydrogen-annealed oxide is the gate oxide and the position of the mobile charge is sensed by the shift of the I-V curve. Much is still not understood about the motion of the charge across the buried oxide. Previous work has assumed that H+ transport and the time it takes to traverse the oxide is governed by interactions within the bulk of the oxide. Based on parameters that affect the transport time, we conclude that H+ trapping and detrapping at the Si/SiO2 interface are more important than H+ interactions within the oxide bulk. These parameters include the applied field, the H+ concentration and the oxide thickness. One consequence is that projections of device write-time based on the previous assumptions of H+ transport mechanisms may be overly optimistic.

P J Macfarlane

The Alpha-Proton-X-Ray Spectrometer Deployment Mechanism: an Anthropomorphic Approach to Sensor Placement on Martian Rocks and Soil

On July 4,1997, the Mars Pathfinder spacecraft lands on Mars and starts conducting technological and scientific experiments. One experiment, the Alpha-Proton-X-ray Spectrometer, uses a sensor head placed against rocks and soil to determine their composition. To guarantee proper placement, a deployment mechanism mounted on the Mars Rover aligns the sensor head to within 20 deg of the rock and soil surfaces. In carrying out its task, the mechanism mimics the action of a human hand and arm. Consisting of a flexible wrist, a parallel link arm, a brush dc motor actuator, and a revolutionary non-pyrotechnic fail-safe release device, the mechanism correctly positions the sensor head on rocks as high as 0.29 m and on targets whose surfaces are tilted as much as 45 deg from the nominal orientation of the sensor head face. The mechanism weighs less than 0.5 kg, can withstand 100 g's, and requires less than 2.8 N x m of actuation torque. The fail-safe coupler utilizes Cerrobend, a metal alloy that melts at 60 C, to fuse the actuator and the rest of the mechanism together. A film heater wrapped around the coupler melts the metal, and Negator springs drive the mechanism into its stowed position. The fail-safe actuates using 6.75 Watts for 5 minutes in the event of an actuator failure.

Richard S Blomquist

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN

Search for soft unclustered energy patterns produced in association with a W or Z boson in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A search for a Higgs boson produced in association with a W or Z boson and decaying via a soft unclustered energy pattern (SUEP) is presented. The analysis is based on proton-proton collision data corresponding to an integrated luminosity of 138 fb −1 collected between 2016 and 2018 at the LHC. Final states with a leptonic W or Z boson decay associated with a high multiplicity of low-momentum charged particles are explored for the first time. The results show no significant excess over the standard model background expectation. Limits are set on the production cross section of a Higgs boson that decays to a SUEP, for a range of parameters of the SUEP model. Material is provided to facilitate further interpretation of the results.

CMS

Photoelectrochemical Proton-Coupled Electron Transfer of TiO 2 Thin Films on Silicon

TiO 2 thin films are often used as protective layers on semiconductors for applications in photovoltaics, molecule–semiconductor hybrid photoelectrodes, and more. Experiments reported here show that TiO 2 thin films on silicon are electrochemically and photoelectrochemically reduced in buffered acetonitrile at potentials relevant to photoelectrocatalysis of CO 2 reduction, N 2 reduction, and H 2 evolution. On both n-type Si and irradiated p-type Si, TiO 2 reduction is proton-coupled with a 1e – :1H + stoichiometry, as demonstrated by the Nernstian dependence of the Ti 4+/3+ E 1/2 on the buffer pK a . Experiments were conducted with and without illumination, and a photovoltage of ∼0.6 V was observed across 20 orders of magnitude in proton activity. The 4 nm films are almost stoichiometrically reduced under mild conditions. The reduced films catalytically transfer protons and electrons to hydrogen atom acceptors, based on cyclic voltammogram, bulk electrolysis, and other mechanistic evidence. TiO 2 /Si thus has the potential to photoelectrochemically generate high-energy H atom carriers. Characterization of the TiO 2 films after reduction reveals restructuring with the formation of islands, rendering TiO 2 films as a potentially poor choice as protecting films or catalyst supports under reducing and protic conditions. Altogether, this work demonstrates that atomic layer deposition TiO 2 films on silicon photoelectrodes undergo both chemical and morphological changes upon application of potentials only modestly negative of RHE in these media. While the results should serve as a cautionary tale for researchers aiming to immobilize molecular monolayers on “protective” metal oxides, the robust proton-coupled electron transfer reactivity of the films introduces opportunities for the photoelectrochemical generation of reactive charge-carrying mediators.

Electrodes

Structure of Self-Generated Magnetic Fields in Laser-Solid Interaction from Proton Tomography

Self-generated magnetic fields in laser-solid interactions are experimentally characterized to reveal the 3D location and local field strength, rather than path-integrated quantities, using multi-view proton radiography and tomographic inversion. We infer magnetic fields that extend several millimeters off the target into the hot, rarefied corona, sufficient to strongly magnetize the plasma (Ω e τ e ≫ 1). The data are compared to MHD simulations incorporating recent improvements in modeling magnetic field generation and transport; the volume-averaged coronal field strength and magnetic flux agree to within 25% using a model with magnetic re-localization of transport, although the near-target morphology is not reproduced. This work demonstrates tomographic proton radiography as a valuable tool for investigating magnetic fields in laser-produced plasmas.

High-energy-density plasmas

Multi-modal dynamic radiography using short-pulse laser-generated probe beams

Radiography is an important tool for the interrogation of dynamic experiments in the fields of dynamic properties of materials, and in condensed matter, high explosive, and high-energy-density physics. Multi-modal radiography advances the hypothesis that combining the information delivered by multiple radiographic modalities can lead to more constrained (improved) “reconstruction” of the scene than can be obtained from a single probe. We identify four modalities: multi-probe, time sequence, multi-view, and multi-messenger. Multi-probe radiography is a promising candidate for a next-generation dynamic radiographic facility. High-energy X-rays are the most frequently used probe for dynamic radiography, although recent developments show the utility of proton (pRad), electron (eRad), and neutron probe beams. Because each probing species interacts with material in the radiographic scene through quantitatively different mechanisms, each returns independent information about the scene, which can add extra constraints to the reconstruction process. How to conduct detailed, quantitative “co-analysis” of multiple data streams remains an area of active research. Multi-beam, short-pulse, laser-generated probes offer sufficient dose, an appropriate spectrum, and appropriate spatio-temporal resolution to produce high-quality dynamic radiographs. This paper reports on technology development to advance the state of the art of multi-modal/multi-probe radiography and the pursuit of both deterministic and inferential (AI/ML assisted) co-analysis methodologies to produce more constrained reconstructions from multi-modal data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

High-Throughput Uniformity and Defect Monitoring in Low-Temperature Electrolysis Porous Transport Layers Using X-Ray Radiography

Effective quality control (QC) for manufacturing proton exchange membrane water electrolysis (PEMWE) components is critical to enabling widespread adoption of the technology for hydrogen generation. This study investigates X-ray radiography as a novel, high-throughput, potentially in-line QC technique for detecting defects and assessing material property distributions in titanium-based porous transport layers (PTLs) which constitute a crucial component of low temperature PEMWE stacks. We obtain radiographs of a set of fifteen PTLs and model their absorbance of the broadband radiation as a second-order polynomial to account for the non-monoenergetic radiation source used in this study. The resulting model serves as a basis for predicting the areal density and porosity distributions of the PTLs. We find radiography successful in detecting multiple instances of defects, including holes/depressions, cracks, and excess material on the surface or in the pores of the material, demonstrating its potential as a robust in-line QC tool for PTL manufacturing.

08 HYDROGEN

Fusion Safety Program Peer Review (August 31 and September 1, 1999) [Slides]

The Fusion Safety Program Peer Review conference, held on August 31 and September 1, 1999, focuses on advancing the understanding and management of radioactive and hazardous materials within deuterium-tritium (D-T) fusion machines. The conference aims to investigate the behavior of significant sources of radioactive materials, such as activation products, dust, tritium, and beryllium. Additionally, it seeks to comprehend how various energy sources in fusion facilities—such as magnets, plasma, decay heat, and chemical reactions—can mobilize these materials. A key objective of the conference is to develop integrated, state-of-the-art analytic tools to demonstrate the safety and environmental potential of fusion technology. Furthermore, the conference assesses and evaluates safety and environmental issues associated with emerging fusion concepts, including those in the ARIES, ALPS, APEX, and IFE projects. This comprehensive approach aims to ensure the safe and sustainable advancement of fusion energy.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY

Final Report: A Multi-Channel Fusion Product

The goal of this project was to measure charged fusion products from the d(d,p)t reaction in MAST-U plasmas as a function of time and position with good energy resolution using a system of up to six charged particle detectors. The data from this new diagnostic will make it possible to determine the neutral beam ion density profile as a function of R, z, and t with reduced model dependency and contribute new information to a global analysis of fast ion diagnostic data needed for the determination of the fast ion distribution function (velocity space tomography).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY