Ferroresonant Flux-Coupled Battery Charger

Portable battery charger operates at about 20 kHz to take advantage of relatively low weight and low acoustical noise of ferroresonant circuits operating in this frequency range. Charger split into stationary unit connected to powerline and mobile unit connected to battery or other load. Power transferred to mobile unit by magnetic coupling between mating transformer halves. Advantage where sparking at electrical connection might pose explosion hazard or where operator disabled and cannot manipulate plug into wall outlet. Likely applications for charger include wheelchairs and robots.

Mclyman, C. W.

Galileo Li/SO sub 2 battery modules program update

In order to meet the power needs of NASA's Galileo Probe, the Li/SO2 high rate D cells used in the battery modules have undergone some design changes, as upgrading of hardware quality requirements, and significant testing. A description of the design changes and the cell test data that are of a general nature is presented here. This data includes capacities, open circuit voltages, and internal resistance comparisons. A significant data base was built up over the years and continues to grow.

Smith, R. A.

Nickel-hydrogen battery state of charge during low rate trickle charging

Battery temperature increase, due to low rate trickle charging, has been determined experimentally, using a six cell battery module in a test setup simulating the anticipated AXAF-1 prelaunch environment. Test results indicate trickle charge rates less than or equal to the self discharge rate do not increase dissipation beyond that due to the self discharge. Significant trickle charge rates (approximately C/500) result in battery temperatures only a few degrees (F) higher than those observed during periods of open circuit stand.

Lurie, C.

Test Program

A test program was set up early in the Explorer XIII program to simulate as nearly as possible all expected environmental conditions to which the spacecraft would be subjected during the ascending phase of the trajectory and while in orbit. These tests included spin, acceleration, thermal-vacuum, vibration, and shock. Functional tests were performed on individual modules of the telemeter system. The test procedure started with breadboard construction of telemeter components. Circuits were evaluated in this phase, and components chosen for prototype construction. Prior to the prototype environmental tests, it was found desirable to construct a mock-up structure for preliminary evaluation of the spacecraft hardware.

Explorer XIII Satellite

Evaluation of Ultrasonic Battery Inspection Techniques

Lithium metal batteries are prone to subtle defects such as internal dendrites, which can cause internal short circuits and lead to catastrophic ignition. These defects are often undetectable by battery management systems, prompting the need to advance nondestructive evaluation (NDE) techniques for battery applications. In this work, two ultrasonic approaches were compared to establish their relative merits for this application: local ultrasonic resonance spectroscopy, and guided wave ultrasound. Benchtop experiments on batteries seeded with lithium chips emulating plating were used to demonstrate the two techniques. The results show the ability to identify and map local changes in cell structure.

Ultrasound

Evaluation of Ultrasonic Battery Inspection Techniques

Lithium metal batteries are prone to subtle defects such as internal dendrites, which can cause internal short circuits and lead to catastrophic ignition. These defects are often undetectable by battery management systems, prompting the need to advance nondestructive evaluation (NDE) techniques for battery applications. In this work, two ultrasonic approaches were compared to establish their relative merits for this application: local ultrasonic resonance spectroscopy, and guided wave ultrasound. Benchtop experiments on batteries seeded with lithium chips emulating plating were used to demonstrate the two techniques. The results show the ability to identify and map local changes in cell structure.

Ultrasound

Performance Optimization for Lunar Extravehicular Activity Readiness (POLAR) Study: Methods Paper

To better understand which aspects of physical fitness may be most related to performance during Lunar surface operations and thereby help to inform the current NASA fitness standards, much can be learned from fields encompassing the “tactical athlete.” Other physically demanding professions such as law enforcement, military, or rescue professionals often require candidates to meet occupationally-relevant fitness standards. The determination of such standards is a multistep process, including both objective and subjective measures, to determine tasks essential to occupational performance and identify the minimal fitness profile needed to meet physical demands of the job. Notably, fitness is only one component which may contribute to the demands of astronaut selection, flight assignment, and occupational performance. Utilizing a framework to systematically determine which domains of fitness most contribute to relevant job tasks can aid in the refinement of current NASA-STD-3001 fitness standards. Therefore, NASA’s Exercise Physiology & Countermeasures Laboratory conducted the Performance Optimization for Lunar Extravehicular Activity Readiness (POLAR) study to identify and examine a comprehensive list of fitness tests (including NASA-STD-3001 assessments: 1-Repetition Maximum [1-RM] bench press and deadlift) and determine preliminary relationships between identified fitness parameters and novel Artemis-relevant tasks to help inform future investigations for the continued development of aerobic and muscular fitness standards for surface EVAs. This was accomplished through 1) a review of the literature relating fitness assessments to simulated or real EVA performance to identify fitness tests that are most correlated with simulated EVA task performance; 2) a task analysis following a modified framework for physical employment standards development to down select mission critical tasks; and 3) development and pilot testing of a novel, portable Artemis-relevant EVA task circuit to relate to a battery of fitness assessments. The current report describes the methodology used to complete the task analysis, EVA task circuit development, and the pilot study.

Nicole C Strock

Energetics of Single Substitutional Impurities in NiTi

Shape-memory alloys are of considerable current interest, with applications ranging from stents to Mars rover components. In this work, we present results on the energetics of single substitutional impurities in B2 NiTi. Specifically, energies of Pd, Pt, Zr and Hf impurities at both Ni and Ti sites are computed. All energies are computed using the CASTEP ab initio code, and, for comparison, using the quantum approximate energy method of Bozzolo, Ferrante and Smith. Atomistic relaxation in the vicinity of the impurities is investigated via quantum approximate Monte Carlo simulation, and in cases where the relaxation is found to be important, the resulting relaxations are applied to the ab initio calculations. We compare our results with available experimental work.

Binary Alloys

High voltage battery cell scanner development

Battery cell voltage scanners have been previously used in low voltage spacecraft applications. In connection with future missions involving an employment of high-power high voltage power subsystems and/or autonomous power subsystem management for unattended operation, it will be necessary to utilize battery cell voltage scanners to provide battery cell voltage information for early detection of impending battery cell degradation/failures. In preparation for such missions, a novel battery cell voltage scanner design has been developed. The novel design makes use of low voltage circuit modules which can be applied to high voltage batteries in a building block fashion. A description is presented of the design concept and test results of the high voltage battery cell scanner, and its operation with an autonomously managed power subsystem is discussed.

Lepisto, J. W.

Engineering and Abuse Testing of Panasonic Lithium-Ion Battery and Cells

This viewgraph presentation reviews the performance testing of Lithium Ion batteries and cells under different conditions of charge and discharge. The tests show that the 0.5 C rate of charge and discharge might be the ideal condition for long term cycling. It reviews the issues of overcharge and overdischarge of the cells. The cells and the battery have adequate protection under both conditions to prevent any catastrophic occurrences. Temperatures above 150 C are required to vent the cells or cause a thermal runaway, Since this situation is non-credible in the cabin of the Space Shuffle or ISS this should not pose a problem. The presentation includes graphs and charts showing the charge and discharge capacities of the battery and also the current and voltage profiles. A view of a circuit board which contains the controlling mechanism for the battery is also shown.

Jeevarajan, Judith A.

Lightweight bipolar storage battery

An apparatus [10] is disclosed for a lightweight bipolar battery of the end-plate cell stack design. Current flow through a bipolar cell stack [12] is collected by a pair of copper end-plates [16a,16b] and transferred edgewise out of the battery by a pair of lightweight, low resistance copper terminals [28a,28b]. The copper terminals parallel the surface of a corresponding copper end-plate [16a,16b] to maximize battery throughput. The bipolar cell stack [12], copper end-plates [16a,16b] and copper terminals [28a,28b] are rigidly sandwiched between a pair of nonconductive rigid end-plates [20] having a lightweight fiber honeycomb core which eliminates distortion of individual plates within the bipolar cell stack due to internal pressures. Insulating foam [30] is injected into the fiber honeycomb core to reduce heat transfer into and out of the bipolar cell stack and to maintain uniform cell performance. A sealed battery enclosure [ 22] exposes a pair of terminal ends [26a,26b] for connection with an external circuit.

Rowlette, John J.

Quantifying Primary Arc-Induced Degradation of Perovskite Solar Cells

Primary arcing induced by spacecraft charging presents a significant hazard to thin film solar cells if left unchecked. Here, we present the results of a preliminary effort to quantify the impacts of primary arcing to perovskite solar cells. Solar cells operating in a charged environment are susceptible to electrostatic discharges known as arcing. While primary arcs are not generally considered a major concern for traditional space PV, for thin film cells, these can induce significant heating and subsequent damage. We conducted ESD testing in a LEO-like plasma in the National Plasma Interaction Facility at NASA Glenn Research Center to quantify impacts to cell performance by arcing. The perovskites tested saw a decrease of short circuit current with an increased number of arcs, averaging a relative change of 73.89 ± 15.90% after 60 total arcs supplied a cumulative energy dose of 76.12 mJ to the string. Ongoing work entails testing with larger perovskite data sets and expanding to include additional thin film cell technologies to demonstrate the risk unmitigated primary arcing presents.

primary arcing

Comparison and Application of Battery Modeling Methods for Conceptual Electric Aircraft

Growing interest in design and optimization of electrified aircraft propulsion concepts prompts the need for accurate, flexible, and efficient methods to model battery systems. Presented in this paper are three battery modeling methods that have been used at NASA’s Glenn Research Center, each representing different mathematical or electrical approaches. Thévenin equivalent circuit, normalization, and curve-fitting methods are compared against battery cell test data for the X-57 Maxwell electric aircraft technology demonstrator. The methods are then applied in a simple multidisciplinary optimization context using NASA’s Six-Passenger Electric Quadrotor concept to determine their applicability and performance. The normalization method achieves the highest accuracy for steady and unsteady discharge rates with a voltage mean error percentage of 0.423% and 1.186%, respectively. Optimal quadrotor mission range between the models varies up to 0.5 nmi, identifying current battery modeling methods as a potentially significant contributor to mission analysis error. A set of relevant tools and techniques for conceptual battery modeling are identified in this paper, with conclusions made on the utility of each modeling approach for various design challenges.

power

Atmospheric, Non-Combusting Droplet Sizing and Spray Imaging Results From a Non-Proprietary Aero Gas Turbine Engine Pressure Swirl Atomizer using Shadowgraphy and Planar Laser Scatter

Members from industry and federal agencies of the United States have developed a collaborating group focused on improving the understanding of the atomization processes common to gas turbine engines. The group is aimed on providing high quality data using x-ray diagnostics in the internal geometry and the near-field dense spray as well as optical diagnostics in the visible spectrum, downstream of the nozzle. This paper reports results from one of the two non-proprietary injectors designs from the group: the primary-secondary injector. In particular, we characterize the spray from only the primary, pressure-swirl atomizing circuit using water through the nozzle. We observed Sauter mean diameter decreased with increased water pressure drop across the nozzle. SMD was also collected at three axial distances and showed decreased size with distance from the nozzle. Planar laser sheet droplet scattering provided qualitative assessment of the spray. Higher water pressure drops provided better atomization than lower pressure drops. The addition of swirling air flow through the injector alleviates and improves the atomization quality, particularly at the lower water pressure drops.

optical diagnostics

Battery test expert systems

The characteristics of NIHBES (nickel-hydrogen battery expert system) are described, with attention also given to NICBES-2 (nickel-cadmium battery expert system-2). The nickel-hydrogen battery testbed is set up almost identically to the nickel-cadmium battery testbed, with the exceptions of no battery protection and reconditioning circuits (BPRCs) and the frequency of transmission of data. The Ni-H2 testbed has no BPRCs and the data are transmitted every 30 s instead of every minute. An expert system shell was chosen to develop this particular expert system. The GoldWorks expert system shell from Gold Hill Computers was chosen for the task. NIHBES will extract the desired data and return fault diagnosis, status and advice, and decision support. Expert systems have been proven to be viable tools in the control and monitoring of space power systems. Presently, the DDAS (digital data acquisition system) monitors and controls the orbit time, and is responsible for limit checking, data acquisition, and data summaries. It is concluded that in the future control of the Hubble Space Telescope breadboard will be passed to NIHBES. NIHBES will be more beneficial to the testbed than the DDAS alone due to the limitations of the DDAS. The DDAS cannot provide long-term trend analysis, plotting capability, fault diagnosis, or advice.

Johnson, Yvette B.

Lead-acid battery

A light weight lead-acid battery (30) having a positive terminal (36) and a negative terminal (34) and including one or more cells or grid stacks having a plurality of vertically stacked conductive monoplates (10, 20) with positive active material and negative active material deposited on alternating plates in the cell or grid stack. Electrolyte layers (26, 28) positioned between each monoplate are included to provide a battery cell having four sides which is capable of being electrically charged and discharged. Two vertical positive bus bars (42, 43) are provided on opposite sides of the battery cell for connecting the monoplates (10) with positive active material together in parallel current conducting relation. In addition, two negative bus bars (38, 39) on opposite sides of the battery cell each being adjacent the positive bus bars are provided for connecting the monoplates (20) with negative active material together in parallel current conducting relation. The positive (42, 43) and negative (38, 39) bus bars not only provide a low resistance method for connecting the plurality of conductive monoplates of their respective battery terminals (36, 34) but also provides support and structural strength to the battery cell structure. In addition, horizontal orientation of monoplates (10, 20) is provided in a vertical stacking arrangement to reduce electrolyte stratification and short circuiting due to flaking of positive and negative active materials from the monoplates.

Rowlette, John J.

Battery Failure Databank

The Battery Failure Databank contains thermal runaway results gathered from nearly 300 small format fractional thermal runaway calorimetry (S-FTRC) experiments. A majority of these experiments were conducted at synchrotron facilities where high-speed x-ray videography was conducted of the cell while tested inside of the S-FTRC. The databank is a two-component system which consists of a Microsoft ExcelTM spreadsheet which provides S-FTRC results in tabular format and a radiographic video library containing the high-speed x-ray videos. Overall, the databank provides thermal results from S-FTRC experiments conducted on a mixture of commercially available lithium-ion (Li-ion) cells and specialized Li-ion test cells with varying cell format (18650, 21700, and D-cell) and trigger mechanism (heaters, heaters plus internal short circuiting device, and nail penetration). The radiography video component provides insight into the initiation and propagation of TR in the cells, in addition to consequences of TR measured by the FTRC. Fractions of mass ejected for the cell types are separated into regimes based on the different failure modes of the cells, such as purely venting, partial ejection, and total ejection. With knowledge of the rate and characterization of the internal degradation of the cells during TR, and the amounts of mass ejected and unrecovered, the extent of TR, and therefore the mitigation of TR, is revealed relative to cell types and failure modes.

Lithium-ion battery

Performance of Two Battery Prognostic Applications used by Two Octocopters for Safe Low Altitude Autonomous Flight Operations

This paper addresses the problem of building trust in online predictions of the remaining available flying time for two different electric Unmanned Aerial Vehicles (eUAVs) powered by lithium-ion-polymer batteries. Flight tests for various automation research missions for the two vehicles were monitored using two on-board battery health management applications to make predictions of the remaining flying time (RFT) for each eUAV and to predict the state of the battery. Playback of the voltage, current and temperature profiles of the battery discharge were used to assess the accuracy of the estimation of the voltage and the charge states of the models as well as the estimate of the RFT. The reference ground truth values were the observed landing time and the measured battery pack resting pack voltage 20 minutes after the flight. The predicted RFT, state of charge (SoC), and state of energy (SoE) were compared with the observed results. Noise values of one standard deviation from the mean values of the internal charge states of the battery model during a reference run were used to vary the states during simulation. One application used an equivalent circuit model of the electrical dynamics of the battery pack, and the other application used a reduced-order electrochemistry model. The variation of the model state components was compared to the variation in the estimate of the RFT and the variation in the SoE to estimate a confidence factor. Variation in the estimates caused by factors affecting the off-line laboratory parameter identification experiments is considered. Variation in the estimates due to environmental factors are discussed.

Assurance