Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiation effects in devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Thermomechanical Properties of Hafnium Hydride for Radiation Shielding in Tokamak Devices

The development of effective neutron shielding materials is of paramount importance for the progression of fusion technologies with the aim of producing clean and sustainable energy for future generations. This study demonstrates the successful fabrication of a promising candidate material for shielding applications, hafnium hydride, through the powder metallurgy process. Powder metallurgy fabrication resulted in the production of 91% dense, crack-free, ε-phase HfH 2 pellets with a hydrogen-to-metal ratio of 1.89 to 2.00. Resonant ultrasound spectroscopy (RUS) was used to measure a Young’s modulus of 34.52 ± 2.70 GPa and a shear modulus of 12.25 ± 0.18 GPa. Nanoindentation techniques have been used to establish a hardness value of 4.45 ± 1.63 GPa, and a Young’s modulus of 47.8 ± 6.4 GPa was determined using Poison’s ratio from RUS. Hydrogen release was measured using thermogravimetric analysis and appeared to occur in three different regimes as the sample transitioned through the ε- and δ-phases. Heat capacity matched literature data up to 600 K, after which a rapid increase was observed due to phase transformations occurring with hydrogen loss.

Hafnium hydride↗

High power targets: Challenges of next-generation high-intensity neutrino beams

High power target systems are crucial elements in enabling future neutrino and other rare particle beams. These systems transform intense source of protons into secondary particles of interest to enable new scientific discoveries. As primary beam intensities increase in next-generation multi-megawatt accelerator facilities, high power target systems face key challenges. Thermal shock and radiation damage effects in beam-intercepting devices were identified as the leading cross-cutting challenges of high-power target facilities. Target materials R&D to address these challenges are therefore essential to enable and ensure reliable operation of future accelerator target facilities. This paper provides an overview of the R&D activities underway to help support high power target systems development for next-generation multi-MW facilities.

43 PARTICLE ACCELERATORS↗

New proposed ITER divertor design using carbon insert on tungsten to mitigate ELMs and secondary radiation effects on nearby components

Abstract Building a successful device for the magnetic fusion energy production is a great challenge. ITER is an international project of the tokamak based magnetic fusion design being developed for the demonstration of the feasibility of thermonuclear technologies for future realization of successful commercial fusion energy. A key obstacle to a successful magnetic fusion energy production is however, the performance during abnormal events including plasma disruptions and edge-localized modes (ELMs). A credible reactor design must tolerate at least a few of these transient events without serious consequences such as melting of the structure. This paper investigates and compares the performance of the current ITER tokamak design during two types of transient events, i.e., ELMs occurring at normal operation and disruptions during abnormal operation. We simulated the divertor components response using our integrated 3D HEIGHTS package. The simulations include self-consistent modeling of the interaction of the released core plasma particles with the initial solid divertor material, energy deposition processes, vaporization of divertor material, secondary plasma formation and MHD evolution, incident core particles collisions and scattering from this dense secondary plasma, photon radiation of secondary plasma, and the resulting heat loads on nearby components. Our simulations showed that using a small carbon insert around the strike point can significantly reduce the overall expected damage on the tungsten dome structure, reflector plates, and prevent tungsten vaporization and its potential core plasma contamination.

47 OTHER INSTRUMENTATION↗

A review of radiation-induced damage to quantum dots

Quantum dots (QDs) are versatile nano structures that have applications in many fields of research and production, including biosensor technology, computing, photovoltaics, and optoelectronics. QDs have gained interest in the field of radiation detection because of their relative ease of production, tunable photoluminescence, and sensitivity to ionizing radiation. The photoluminescent properties of QDs diminish proportionally to prolonged ionizing radiation interactions, leading many groups to seek out these materials as potential candidates for the next generation of inexpensive, easily manufactured dosimetry and sensors. To use QDs in these applications, the mechanisms of radiation damage to the nanomaterial must be clearly understood and characterized. Herein, we review the study of ionizing radiation damage to QDs. First, the synthesis and properties of QDs are briefly discussed. Next, the radiation damage to QDs due to heavy charged particles, fast electrons, high energy photons, and neutrons are detailed. After this, experimental methods and modelling of QDs in radiation environments are examined. Lastly, future research directions are provided. The goal of this review is to aid in understanding the ionizing radiation effects on QD-based devices.

Snow, Jesse [University of Utah, Salt Lake City, U↗

Electromagnetic Radiation Effects on MgO-Based Magnetic Tunnel Junctions: A Review

Magnetic tunnel junctions (MTJs) have been widely utilized in sensitive sensors, magnetic memory, and logic gates due to their tunneling magnetoresistance. Moreover, these MTJ devices have promising potential for renewable energy generation and storage. Compared with Si-based devices, MTJs are more tolerant to electromagnetic radiation. In this review, we summarize the functionalities of MgO-based MTJ devices under different electromagnetic irradiation environments, with a focus on gamma-ray radiation. We explore the effects of these radiation exposures on the MgO tunnel barriers, magnetic layers, and interfaces to understand the origin of their tolerance. This review enhances our knowledge of the radiation tolerance of MgO-based MTJs, improves the design of these MgO-based MTJ devices with better tolerances, and provides information to minimize the risks of irradiation under various irradiation environments. This review starts with an introduction to MTJs and irradiation backgrounds, followed by the fundamental properties of MTJ materials, such as the MgO barrier and magnetic layers. Then, we review and discuss the MTJ materials and devices’ radiation tolerances under different irradiation environments, including high-energy cosmic radiation, gamma-ray radiation, and lower-energy electromagnetic radiation (X-ray, UV–vis, infrared, microwave, and radiofrequency electromagnetic radiation). In conclusion, we summarize the radiation effects based on the published literature, which might benefit material design and protection.

42 ENGINEERING↗

Benchmarking MCNP models to support gamma irradiation experiments

Seismic isolators and damping devices have been used for 30+ years to reduce seismic forces and deployed in 10,000+ structures, including bridges, buildings, and mission-critical infrastructure. Studies have shown that seismic isolation of nuclear power plants can reduce the seismic risk by several orders of magnitude and substantially reduce the overnight capital cost. Advanced reactor developers are considering seismic isolation as an integral design feature in their reactor design. It can either be deployed at the building level, isolating the entire reactor building, or at the component level, isolating individual pieces of safety-class equipment, such as a reactor vessel or a steam generator. For equipment isolation, located close to the reactor vessel, the seismic isolators and/or damping devices may be exposed to gamma and neutron radiation, with a possible effect on their mechanical properties which would affect the response of the isolated equipment under earthquake shaking. The Department of Energy, as part of its Nuclear Energy University Program (NEUP), in collaboration with the Idaho National Laboratory (INL), is funding a project at the University at Buffalo (UB) to investigate the effect of gamma radiation on the mechanical properties of various seismic protective devices. (When isolating equipment, the seismic protective devices will be located outside the reactor vessel where the neutron exposure will be insignificant.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Probing elemental diffusion and radiation tolerance of perovskite solar cells via non-destructive Rutherford backscattering spectrometry

Mixed organic–inorganic halide perovskite-based solar cells have attracted interest in recent years due to their potential for both terrestrial and space applications. Analysis of interfaces is critical to predicting device behavior and optimizing device architectures. Most advanced tools to study buried interfaces are destructive in nature and can induce further degradation. Ion beam techniques, such as Rutherford backscattering spectrometry (RBS), is a useful non-destructive method to probe an elemental depth profile of multilayered perovskite solar cells (PSCs) as well as to study the inter-diffusion of various elemental species across interfaces. Additionally, PSCs are becoming viable candidates for space photovoltaic applications, and it is critical to investigate their radiation-induced degradation. RBS can be simultaneously utilized to analyze the radiation effects induced by He+ beam on the device, given their presence in space orbits. In the present work, a 2 MeV He+ beam was used to probe the evidence of elemental diffusion across PSC interfaces with architecture glass/ITO/SnO2/Cs0.05(MA0.17FA0.83)0.95Pb(I0.83Br0.17)3/spiro-OMeTAD/MoO3/Au. During the analysis, the device active area was exposed to an irradiation equivalent of up to 1.62 × 1015 He+/cm2, and yet, no measurable evidence (with a depth resolution ∼1 nm) of beam-induced ion migration was observed, implying high radiation tolerance of PSCs. On the other hand, aged PSCs exhibited indications of the movement of diverse elemental species, such as Au, Pb, In, Sn, Br, and I, in the active area of the device, which was quantified with the help of RBS.

14 SOLAR ENERGY↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Hall Effect Characterization of α ‐Irradiated p‐Type 4H‐SiC

Most electrical characterization of radiation damage to semiconductors is conducted on full devices or on low‐doped material. However, evaluating the radiation hardness is challenging in less mature semiconductor systems where low‐doped material is unavailable and full devices are difficult to realize. Herein, temperature‐dependent Hall effect measurements are used to demonstrate α particle‐induced radiation effects in p‐type 4H‐SiC with a room temperature hole concentration of . The 4H‐SiC is irradiated by α particles from a 210 Po source over a fluence of –. Modeling the hole concentration as a function of temperature shows that α radiation causes hole compensation through the introduction of hole traps. The radiation also induces a reduction in hole mobility due to an increase in defect‐related scattering centers. At low temperatures and increasingly higher fluences, the conduction mechanism changes from band conduction to another mechanism.

Frye, Clint D.↗

Room temperature slot-die coated perovskite layer modified with sulfonyl-γ-AApeptide for high performance perovskite solar devices

Perovskite solar cells (PSCs) exhibited remarkable progress for small aperture area cells, however, the performance of its counterpart, large aperture area cells, lags due to non-uniform and defective perovskite layers. Here, we fabricate reproducible large area homogeneous perovskite films at room temperature and without controlling humidity (up to 40 % RH) with a slot die coater on a c-TiO 2 layer deposited using a large area chemical bath. A new artificial peptide – sulfonyl-γ-AApeptide (F-GLU-S) was employed to modify the slot-die coated perovskite surface, grain boundaries and electronic defects. The multi-functional F-GLU-S with carbonyl, carboxyl, sulfonyl, benzene, and chloro groups was capable of strongly interacting with the perovskite layer and repairing the uncoordinated Pb 2+ ions and halide vacancies. As a result, both the electron and hole densities of defects were significantly suppressed; consequently, the non-radiative recombination was effectively suppressed for the modified device which can be explicitly seen in the device performance where both V oc and FF of the modified device improved considerably. Therefore, F-GLU-S modified slot-die coated MAPbI 3 – based devices demonstrated outstanding performance of 21.44 % PCE with a V oc of 1.13 V, J sc of 24.64 cm –2 , and FF 76.99 %. Furthermore, F-GLU-S passivation impeded the infiltration of moisture and oxygen due to its hydrophobic nature and defect repair potential. As a result, the modified device retained above 92 % of its original PCE after 720 h in air (room temperature and 40–60 % RH).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Connecting radiation-driven changes in structural, thermal, and mechanical properties in several medical device polymers

Stemming from security threats and shortages in supply, a recent push has emerged to develop alternatives to radioisotope Cobalt-60 gamma radiation for sterilization of polymeric medical products, including electron beam (e-beam) and X-ray machine-based sources. However, before large-scale implementation, the effects of these non-isotope-based methods must be thoroughly investigated from several perspectives, involving their potential detrimental effects on the structural, thermal, and mechanical properties of polymers in medical devices. This paper investigates such effects in commonly used medical device polymers, including polypropylene homopolymer (PPH), polyolefin elastomer (POE), low-density polyethylene (LDPE), acrylonitrile butadiene styrene (ABS), and chlorobutyl rubber (CIIR). To connect radiation-driven changes in polymer structural and thermal properties and corresponding changes in mechanical properties, several characterization techniques were utilized, including gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). We found that the tensile strength of X-ray irradiated PPH, as well as X-ray, e-beam, and gamma irradiated CIIR decreases due to chain scission, which is corroborated by GPC and DMA. The GPC results of LDPE suggest chain scission, but interestingly without a corresponding decline in tensile strength. By comparison, POE and ABS appear to undergo further crosslinking with increasing irradiation dose, which generally strengthens them. Importantly, in the vast majority of the cases, there were small to no changes in properties upon changing radiation technologies (at a given dose), i.e., no radiation source dependence. However, in a few specific cases, radiation method dependencies did arise, for instance, in terms of the molecular weight of PPH being significantly increased upon X-ray irradiation, while the melting temperature, glass transition temperature, and elongation at break reduced compared to gamma. Overall, this study provides valuable insight into radiation-driven chemical and structural changes in polymers that produce changes in physical and functional properties.

36 MATERIALS SCIENCE↗

Radiation testing of 2.4 micron wavelength extended InGaAs photodiodes for 100 MeV/n carbon ions

We have successfully tested simultaneously 2.4 Micron Wavelength, Extended InGaAs Photodiodes having diameters of 20, 30, 40, 50, 100, 150, 200, 250, and 290 Micron, coupled with a Single Mode Fiber using 100 MeV/n Carbon (C) Ions up to a cumulative dose of ~40 krad. During irradiation, the devices were maintained at dry ice temperature, reverse biased at 100 mV, and their leakage current was continuously monitored in-situ during the run. After the exposure was completed, all nine devices were monitored for any change in their leakage current at 100 mV and room temperature for several weeks to monitor any annealing effects that may occur. Nine Photodiodes with the above varying diameters were radiated with 100 MeV/n Carbon Ions with a fluence of 10 6 , 10 7 , 10 8 , 10 9 , and 10 10 ions/cm 2 at each fluence level. At 100 MeV/n the Linear Energy Transfer (LET) of Carbon Ion is ~0.156 MeV-cm 2 /mg in Extended InGaAs, which is an order magnitude more than Proton (H) and Helium (He) Ions of 100 MeV/n energy. Thus, significant displacement damage is anticipated in the Extended InGaAs Photodiode with 100 MeV/n Carbon Ions with a total fluence of 1 × 1010 ions/cm 2 . Pre- and Post- radiation results were also measured for: (1) Leakage Current Vs. Voltage for the Extended InGaAs Photodiodes; (2) Responsivity (Quantum Efficiency) in A/W for Photodiodes; and (3) Bandwidth of the Photodiodes. All devices were found to be fully functional at the normal operating conditions and at both dry ice and room temperature. The leakage current increased up to a factor of ~2X at lower bias of 100 mV at the highest fluence of 10 10 ions/cm 2 , but not significantly at higher bias of 2 V. Finally, we did not observe any post radiation annealing effect for leakage current at room temperature and 100 mV bias for any of the devices after several weeks of data logging.

2.4 micron wavelength↗

Ionizing Radiation Sensing with Functionalized and Copper-Coated SWCNT/PMMA Thin Film Nanocomposites

This paper studies the ionizing radiation effects on functionalized single-walled carbon nanotube (SWCNT)/poly(methyl methacrylate) (PMMA) thin-film nanocomposites [SWNT/PMMA]. The functionalized thin-film devices are made of ferrocene-doped SWCNTs, SWCNTs functionalized with carboxylic acid (COOH), and SWCNTs coated/ modified with copper. The nanocomposite was synthesized by the solution blending method and the resulting nanocomposite was spin-cast on interdigitated electrodes (IDEs). A 160 kV X-ray source was used to irradiate the thin film and changes in the electrical resistance of the nanocomposites due to X-rays were measured using a semiconductor device analyzer. Carboxylic acid functionalized and copper-coated SWCNT/PMMA nanocomposite showed a reduced response to X-rays compared to unfunctionalized SWCNT/PMMA nanocomposite. Ferrocene-doped SWCNT showed a higher sensitivity to X-rays at lower dose rates. This is in contrast to a previous study that showed that similar nanocomposites using functionalized multi-walled CNTs (MWCNTs) had demonstrated an improved response to X-rays ionizing radiation compared to unfunctionalized MWCNTs for all dose rates. Electrical measurements were also performed using the Arduino Nano microcontroller. The result showed that a relatively economical, lightweight-designed prototype radiation sensor based on SWCNT/PMMA thin-film devices could be produced by interfacing the devices with a modest microcontroller. This work also shows that by encapsulating the SWCNT/PMMA thin-film device in a plastic container, the effect of ambient humidity can be reduced and the device can still be used to detect X-ray radiation. This study further shows that the sensitivity of SWCNT to X-rays was dependent on both the functionalization of the SWCNT and the dose rate.

36 MATERIALS SCIENCE↗

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charge collection and trapping mechanisms in hexagonal boron nitride epilayers

Understanding charge collection and trapping mechanisms is crucial for using hexagonal boron nitride (h-BN) as active layers for many photonic and electronic devices such as deep UV detectors and emitters, neutron detectors, and single photon emitters. Charge collection and trapping mechanisms in h-BN epilayers have been investigated by probing impurity related optical emissions under an applied electrical field. Our results suggested that the existence of oxygen impurities affects the charge collection efficiency and results in an additional emission peak at 3.75 eV, corresponding to a donor-acceptor pair (DAP) recombination involving O N (oxygen residing on the nitrogen site) donors and the V B -H (boron vacancy bonded with hydrogen complex) deep level acceptors. Experimental results further revealed that the applied electric field induces an anti-correlation between the emission intensity of the DAP transition and the charge collection efficiency from which it was shown that it is possible to find an expression to quantitatively measure the maximum charge collection efficiency in h-BN. The results introduce not only a coherent picture for the relationship between common impurities in h-BN and charge collection and trapping mechanisms but also useful insights into possible approaches to improve the quality, purity, and charge collection of the h-BN epilayers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-Situ Characterization Tools for Evaluating Radiation Tolerance and Elemental Migration in Perovskites

This paper discusses the in-situ characterization tools designed to assess radiation tolerance and elemental migration in perovskite materials. With the increasing use of perovskites in various technological applications, understanding their response to radiation exposure is paramount. Ion Beam Induced Charge (IBIC) emerges as a powerful tool for investigating the radiation tolerance of perovskites at the microscale. By employing focused ion beams, IBIC allows for the spatial mapping of charge carriers, offering insights into the material's electronic response to radiation-induced defects. This technique enables researchers to pinpoint areas of enhanced or suppressed charge collection, providing valuable information on the perovskite's intrinsic properties under irradiation. Rutherford Backscattering Spectrometry (RBS) complements the study by offering a quantitative analysis of elemental migration in perovskite materials. Through the precise measurement of backscattered ions, RBS provides a detailed understanding of the elemental composition and distribution within the perovskite lattice after radiation exposure. The integration of IBIC and RBS techniques in in-situ experiments enhances the comprehensive characterization of radiation effects on perovskites.

ion beams↗

Harvesting Planck radiation for free-space optical communications in the long-wave infrared band

We demonstrate a free-space optical communication link with an optical transmitter that harvests naturally occurring Planck radiation from a warm body and modulates the emitted intensity. The transmitter exploits an electro-thermo-optic effect in a multilayer graphene device that electrically controls the surface emissivity of the device resulting in control of the intensity of the emitted Planck radiation. We design an amplitude-modulated optical communication scheme and provide a link budget for communications data rate and range based on our experimental electro-optic characterization of the transmitter. Finally, we present an experimental demonstration achieving error-free communications at 100 bits per second over laboratory scales.

Weinstein, Haley A.↗