At least 37 records · Page 2

Use of Several Thermal Analysis Techniques on a Hypalon Paint Coating for the Solid Rocket Booster (SRB) of the Space Shuttle

White Hypalon paint is brush-applied as a moisture barrier coating over cork surfaces on each of the two Space Shuttle SRBs. Fine cracks have been observed in the Hypalon coating three times historically on laboratory witness panels, but never on flight hardware. Samples of the cracked and standard ("good") Hypalon were removed from witness panel cork surfaces, and were tested in 1998 by Thermogravimetric Analysis (TGA), TMA and Differential Scanning Calorimetry (DSC) thermal analysis techniques. The TGA data showed that at 700C, where only paint pigment solids remain, the cracked material had about 9 weight percent more material remaining than the standard material, probably indicating incomplete mixing of the paint before it was brush-applied to produce the cracked material. Use of the TMA film/fiber technique showed that the average modulus (stiffness) vs. temperature was about 3 to 6 times higher for the cracked material than for the standard material. The TMA data also showed that an increase in coating thickness for the cracked Hypalon was not a factor in the anomaly.

Wingard, Charles D.↗

Outgassing of Flown and Unflown MIR Solar Cells

A solar panel array with more than ten years space exposure was removed from the Mir core module in November 1997, and an eight panel section was returned to Earth in January 1998. Several solar cells were removed from panel eight of the returned array and placed in a high vacuum system with a residual gas analyzer (200 amu mass spectrometer) and a cold finger. Similar unflown solar cells of the same vintage were later obtained from Energia. Several of the unflown cells were also placed in the vacuum system and outgassed residues were collected on the LN2 cold finger. Almost 3 mg of outgassed residue was collected -from a string of three unflown solar cells over a period of 94 hours under vacuum. The collected residue was weighed with a microbalance, and then the residue was analyzed by FTIR spectroscopy, and by gas chromatograph-mass spectroscopy. About 25 outgassed constituents were separated by the gas chromatograph, and a high-resolution mass spectrum was obtained of each constituent. Molecular identifications have been made for the constituents. The constituents are primarily cyclic siloxanes, and several of the constituents are isomers of the same molecule. Most of the outgassed constituents have a molecular mass of about 500 amu. Almost one mg of residue was extracted from one sq cm of coverglass/adhesive from a flown solar cell by soaking in isopropyl alcohol for 30 minutes. The gas chromatograph separated about 20 constituents. The constituents are mostly cyclic siloxanes with linear branches, hydrocarbons, and phthalates. The typical molecular mass is about 600 amu. These identifications of specific outgassing molecules have resulted in a more complete understanding of the SiO(x) contamination on the Mir solar cell coverglasses, and on the MEEP experiment trays and optical specimens during the Shuttle-Mir Phase One flight experiment program. Adjusted outgassing rates based on the data reported here, and/or measured outgassing rates and specific molecular identifications of ISS hardware samples are needed to input into model predictions of induced environment effects of the ISS.

Harvey, Gale A.↗

Image Quality Indicator for Infrared Inspections

The quality of images generated during an infrared thermal inspection depends on many system variables, settings, and parameters to include the focal length setting of the IR camera lens. If any relevant parameter is incorrect or sub-optimal, the resulting IR images will usually exhibit inherent unsharpness and lack of resolution. Traditional reference standards and image quality indicators (IQIs) are made of representative hardware samples and contain representative flaws of concern. These standards are used to verify that representative flaws can be detected with the current IR system settings. However, these traditional standards do not enable the operator to quantify the quality limitations of the resulting images, i.e. determine the inherent maximum image sensitivity and image resolution. As a result, the operator does not have the ability to optimize the IR inspection system prior to data acquisition. The innovative IQI described here eliminates this limitation and enables the operator to objectively quantify and optimize the relevant variables of the IR inspection system, resulting in enhanced image quality with consistency and repeatability in the inspection application. The IR IQI consists of various copper foil features of known sizes that are printed on a dielectric non-conductive board. The significant difference in thermal conductivity between the two materials ensures that each appears with a distinct grayscale or brightness in the resulting IR image. Therefore, the IR image of the IQI exhibits high contrast between the copper features and the underlying dielectric board, which is required to detect the edges of the various copper features. The copper features consist of individual elements of various shapes and sizes, or of element-pairs of known shapes and sizes and with known spacing between the elements creating the pair. For example, filled copper circles with various diameters can be used as individual elements to quantify the image sensitivity limit. Copper line-pairs of various sizes where the line width is equivalent to the spacing between the lines can be used as element-pairs to quantify the image resolution limit.

Burke, Eric↗

Ultrapure Water System at JSC for High Purity Cleaning of Flight Hardware, Astromaterial Handling Tools and Solar Wind Samples

Use of Ultrapure Water (UPW) for cleaning of astromaterial sample handling tools and containers was driven by the discontinuation of Freon 113 as a cleaning solvent, due to environmental concerns. Freon 113, recycled using distillation, was very effective at removing organic residues from sample handling hardware. The initial switch to high purity water for astromaterial tool cleaning was modeled after efforts at White Sands Test Facility (WSTF) and current semiconductor UPW production practices in the early 1990s. JSC curation’s first system was comprised of ion exchange polishing cylinders, 55 gallon PVDF-lined storage tank, a few tens of feet of PVDF piping, UV and particle filtration, and this system supported cleaning for lunar, meteorite and Cosmic Dust collectors lab operations. By 2000 a major expansion and upgrade was providing UPW of quality E-1 (ASTM D5127-90) or better at 10 gpm for cleaning of the Genesis solar wind payload for flight, in addition to sample handling tools for other astromaterials. This expansion included a 1000 gallon storage tank and several hundred feet of PVDF piping located in B. 31 and 31N. An extra reverse osmosis process unit was added to incoming water in 2005. Subsequently several major components were replaced, and in anticipation of adding new labs, an enlarged UPW system was designed in 2018 and completed in 2019. This system produces grade E1.1 UPW at 15 gpm in a continuous 1100 ft. loop with 5000 gal. storage tank, supplying 8 laboratories.

Ultrapure water↗

Hardware realization of sampled-data controllers

This paper examines the hardware implementation process for digital controllers (filters), beginning with the desired z-domain transfer function of the digital compensator and ending in the selection of a hardware realization scheme. The final hardware realization is shown to be affected by quantization noise, dynamic range considerations, limit cycles, coefficient roundoff, and filter structure. A design example is included to illustrate the implementation process for a digital rate filter for vehicle control of the space shuttle. This paper develops open-loop techniques which may be extended to the closed-loop case.

Nagle, H. T., Jr.↗

Rotary Percussive Sample Acquisition Tool (SAT): Hardware Development and Testing

In support of a potential Mars Sample Return (MSR) mission an Integrated Mars Sample Acquisition and Handling (IMSAH) architecture has been proposed to provide a means for Rover-based end-to-end sample capture and caching. A key enabling feature of the architecture is the use of a low mass sample Acquisition Tool (SAT) that is capable of drilling and capturing rock cores directly within a sample tube in order to maintain sample integrity and prevent contamination across the sample chain. As such, this paper will describe the development and testing of a low mass rotary percussive SAT that has been shown to provide a means for core generation, fracture, and capture.

Integrated Mars Sample Acquisition and Handling (I↗

Microgravity Disturbance Characterization of the Quench Module Insert (QMI) Phase Change Device (PCD)

The Materials Science Research Facility (MSRF) is a multi-user, multi-purpose facility for materials science research. One experiment within the MSRF will be the Quench Module Insert (QMI), a high-temperature furnace with unique capabilities for processing different classes of materials. The primary functions of the QMI furnace are to melt, directionally solidify, and quench metallic samples, providing data to aid in understanding the effects of the microgravity environment on the characteristics of these processed metals. The QMI houses sealed individual sample ampoules containing material to be processed. Quenching of the samples in the QMI furnace is accomplished by releasing low-melting-point metallic shoes into contact with the outside of the sample ampoule, dissipating heat and cooling the sample inside. The impact from this method of quench will induce sample vibrations which could be large enough to adversely affect sample quality. Utilizing breadboard hardware, the sample quench sequence, releasing the shoes, was conducted. Data was collected from accelerometers located on the breadboard sample cartridge, indicating the maximum acceleration achieved by the sample. The primary objective of the test described in this presentation was to determine the acceleration imparted on the sample by the shoe contact. From this information, the science community can better assess whether this method of quench will allow them to obtain the data they need.

Gattis, Christy↗

Mars 2020 sample caching system contamination: how to clean hardware and keep it clean

The Mars 2020 Rover will have the capability to collect and cache samples for potential Mars sample return. Specifically, the sample caching system (SCS) is designed for coring Mars samples and acquiring regolith samples as well as handling, sealing and caching on Mars. As the potential first Martian samples that could be returned to Earth, assuring low levels of terrestrial contamination is of the utmost concern. In developing the SCS, the project prioritizes limiting sample contamination in organic, inorganic and biological areas. The focus of this paper is on the strategies being implemented to clean the assemble the sampling hardware to meet and maintain stringent contamination requirements.

Rainen, Richard↗

Particulate Removal Using a CO2 Composite Spray Cleaning System

The Planetary Protection surface cleanliness requirements for potential Mars Sample Return hardware that would come in contact with Martian samples may be stricter than previous missions. The Jet Propulsion Laboratory has developed a new technology that will enable us to remove sub-micron size particles from critical hardware surfaces. A hand-held CO2 composite cleaning system was tested to verify its cleaning capabilities. This convenient, portable device can be used in cleanrooms for cleaning after rework or during spacecraft integration and assembly. It is environmentally safe and easy to use. This cleaning concept has the potential to be further developed into a robotic cleaning device on a Mars Lander to be used to clean sample acquisition or sample handling devices in situ. Contaminants of known sizes and concentrations, such as fluorescent microspheres and spores were deposited on common spacecraft material surfaces. The cleaning efficiency results will be presented and discussed.

carbon dioxide↗

NASA Omics Archive Project

The space environment consists of a complex set of hazards including altered gravity, radiation, psychological/physiological stress, isolation, and confinement leading to complex biological responses. Advances in biotechnology capabilities offer considerable potential to provide novel insight into those responses as well as innovative diagnostic, treatment, and countermeasure solutions for astronauts as NASA begins to travel beyond low Earth orbit. Omics data (genomics, transcriptomics, proteomics, etc.) is one example that can provide NASA with critical knowledge of how a crewmember’s genetics, environment, and lifestyle can be used to develop individualized approaches for disease prevention, advance diagnostics, and improve treatment strategies. NASA ventured into the field of omics on human subjects with the successful completion of the NASA Twins Study which was the first step in mapping the multi-omic profile of astronauts to understand and mitigate the health consequences of spaceflight. The Human Research Program aims to build upon the success of the Twins Study with the NASA Omics Archive flight study, establishing a longitudinal biospecimen archive and efficiently generating a comprehensive high-quality multi-omic dataset from astronauts for the purpose of studying molecular, metabolic, and microbial changes associated with longduration spaceflight missions. The goal is to facilitate scientific and medical research community efforts to characterize and mitigate spaceflight health and performance risks. In this presentation, we will review details regarding the biospecimen and data archive to be generated by the NASA Omics Archive flight study. Data generated as part of this project will be archived in the NASA Life Sciences Portal (NLSP) and be made available for future hypothesis-driven research efforts or occupational surveillance through Institutional Review Board-approved data sharing and retrospective data requests submitted to the Life Sciences Data Archive (LSDA) team. We will also present results of a ground study performed to evaluate in-house procedures, new sample collection hardware, and vendor capabilities. The data repository generated and the samples to be archived by this study will enable future research efforts to assess an astronauts’ unique molecular and genetic profile with respect to individual spaceflight responses. Results of which will be instrumental in enabling precision health capabilities to better assess and mitigate spaceflight risks, detect disease states earlier, and actively monitor countermeasure treatments, ultimately improving clinical outcomes during future exploration class missions.

C. A. Theriot↗

Refactoring the Curiosity Rover's sample handling architecture on Mars

The Curiosity Mars rover sample handling hardware and software were architected assuming that end-to-end sampling operations would occur in a single rover position, from acquisition of a powdered sample with a scoop or drill, through to the cleaning out of all sample residue in the sample chain. However, after analysis of the first drilled samples in Yellowknife Bay, the science team wanted to iterate with additional experiments on Mars and in laboratories on Earth to better understand their results and increase the value of science returned. With the architecture as conceived, the time needed to do so was in direct competition with the exploration of other targets and satisfaction of success criteria during the prime mission.

Kuhn, Stephen↗

Sampling synchronization through GPS signals

A method uses a distributed data acquisition system with multiple, physically unconnected, data acquisition units, that can be in wireless communication with a remote host, to timestamp measurement data with sub-microsecond time base accuracy of sampling clock relative to an absolute timeframe. A current absolute time is derived from messages received from a satellite radio beacon positioning system (GPS). Measurement data is sampled by each unit at a specified sampling rate. Using hardware logic, batches of sampled data are associated with corresponding timestamps representing the absolute time at which the data was sampled. Data and timestamps may be transmitted to the host. A time offset bias is compensated by comparing timestamps against a nominal time based on start time and nominal sampling rate. The sampling clock rate may be disciplined using time pulses from the GPS receiver. An initial start of data sampling by all units can also be synchronized.

Zhuge, James Q.↗

Investigation of KC-135 flight samples solidified in near-zero gravity

An analysis was conducted of three KC-135 flight samples that had been solidified in near-zero gravity. These samples had been generated during near-zero gravity testing of M553 experiment Skylab flight hardware. The samples evaluated were all Star-J Satellite, a cobalt base alloy. The analytical procedures (optical microscopy, scanning electron microscopy, electron microprobe, X-ray diffraction, differential scanning calorimetry, and microhardness) to be use on the Skylab flight samples were optimized and the analytical results are presented.

Larson, D., Jr.↗

Genesis Solar Wind Sample Curation Facility

The controlled access facility designed and constructed for storing and examining Genesis solar wind samples consists of two adjacent laboratories, both ISO Class 4 cleanrooms (vertical laminar flow, ULPA filtered). One cleanroom is equipped with ultrapure water (UPW) for experimental cleaning of containers and tools used in handling the solar wind samples, flight hardware and witness plates. The ultrapure water is also used for cleaning the solar wind samples. The other cleanroom is for long-term nitrogen storage of samples and for examination and processing of Genesis samples.

Curation Facility↗

The Mars Science Laboratory Organic Check Material

The Organic Check Material (OCM) has been developed for use on the Mars Science Laboratory mission to serve as a sample standard for verification of organic cleanliness and characterization of potential sample alteration as a function of the sample acquisition and portioning process on the Curiosity rover. OCM samples will be acquired using the same procedures for drilling, portioning and delivery as are used to study martian samples with The Sample Analysis at Mars (SAM) instrument suite during MSL surface operations. Because the SAM suite is highly sensitive to organic molecules, the mission can better verify the cleanliness of Curiosity's sample acquisition hardware if a known material can be processed through SAM and compared with the results obtained from martian samples.

Conrad, Pamela G.↗