Modeling Self-Pressurization and Spray Bar Pressure Control of A Cryogenic Storage Tank in Normal Gravity

This paper presents computational fluid dynamics (CFD) models for simulating self-pressurization and spray-bar pressure control processes in a large-scale liquid hydrogen storage tank under normal gravity conditions. For self-pressurization, the model employs the kinetics-based Schrage equation alongside the volume-of-fluid (VOF) method to account for interfacial mass transfer. The CFD predictions of pressure and temperature are compared with experimental data from the Multipurpose Hydrogen Test Bed (MHTB) experiment, and the predicted interfacial mass transfer rates are also presented. A CFD model simulating pressure control using a spray bar has also been developed. An Eulerian-Lagrangian approach models the interactions between discrete droplets and the continuous ullage (vapor) phase. The spray model is coupled with the VOF method by tracking droplets in the ullage and removing them when they reach the liquid interface. The T-sat model calculates droplet-ullage heat and mass transfer, wherein droplets warm up to the saturation temperature corresponding to the ullage vapor pressure before evaporating while remaining at the saturation temperature. The evolution of tank pressure, vapor temperature, and liquid temperature predicted by the CFD model is validated against data from the MHTB spray-bar mixing experiment. Overall, the CFD models agree with experimental data, demonstrating their capability to simulate self-pressurization and pressure control processes in large-scale cryogenic storage tanks. These models can be valuable tools for designing and optimizing cryogenic fluid management systems in future applications.

Self-Pressurization↗

Modeling Self-Pressurization and Spray Bar Pressure Control of a Cryogenic Storage Tank in Normal Gravity

This paper presents Computational Fluid Dynamics (CFD) models for simulating self-pressurization and spray bar cooling processes in a large-scale liquid hydrogen storage tank under normal gravity. The self-pressurization model utilizes the kinetics-based Schrage equation with the Volume-Of-Fluid (VOF) model to account for the evaporative and condensing interfacial mass fluxes. It uses a laminar approach to model natural convection and compares the pressures and temperatures predicted by the CFD model with experimental data from the Multipurpose Hydrogen Test Bed (MHTB) self-pressurization experiment. Additionally, the predicted interfacial mass flux is presented. A CFD model for simulating pressure control using a spray bar is also presented. An Eulerian-Lagrangian approach models the interactions between the discrete droplets and the continuous ullage phase. The spray model is coupled with the VOF model by tracking particles in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. The T-sat model is used to calculate the droplet-ullage heat and mass transfer. In this model, droplets warm up to the saturation temperature corresponding to the ullage vapor pressure thereafter evaporating while remaining at the saturation temperature. The tank pressure, vapor, and liquid temperature evolutions are validated against data from the MHTB spray bar mixing experiment.

Self-Pressurization↗

Thermal Propulsion Capture System Heat Exchanger Design

One of the biggest challenges of manned spaceflight beyond low earth orbit and the moon is harmful radiation that astronauts would be exposed to on their long journey to Mars and further destinations. Using nuclear energy has the potential to be a more effective means of propulsion compared to traditional chemical engines (higher specific impulse). An upper stage nuclear engine would allow astronauts to reach their destination faster and more fuel efficiently. Testing these engines poses engineering challenges due to the need to totally capture the engine exhaust. The Thermal Propulsion Capture System is a concept for cost effectively and safely testing Nuclear Thermal Engines. Nominally, hydrogen exhausted from the engine is not radioactive, but is treated as such in case of fuel element failure. The Thermal Propulsion Capture System involves injecting liquid oxygen to convert the hydrogen exhaust into steam. The steam is then cooled and condensed into liquid water to allow for storage. The Thermal Propulsion Capture System concept for ground testing of a nuclear powered engine involves capturing the engine exhaust to be cooled and condensed before being stored. The hydrogen exhaust is injected with liquid oxygen and burned to form steam. That steam must be cooled to saturation temperatures before being condensed into liquid water. A crossflow heat exchanger using water as a working fluid will be designed to accomplish this goal. Design a cross flow heat exchanger for the Thermal Propulsion Capture System testing which: Eliminates the need for water injection cooling, Cools steam from 5800 F to saturation temperature, and Is efficient and minimizes water requirement.

Richard, Evan M.↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

Terra and Aqua MODIS Thermal Emissive Bands On-Orbit Calibration and Performance

Since launch, the Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on the Terra and Aqua spacecraft have operated successfully for more than 14 and 12 years, respectively. A key instrument for National Aeronautics and Space Administration Earth Observing System missions, MODIS was designed to make continuous observations for studies of Earth's land, ocean, and atmospheric properties and to extend existing data records from heritage Earth observing sensors. The 16 thermal emissive bands (TEBs) (3.75-14.24 micrometers) are calibrated on orbit using a temperature controlled blackbody (BB). Both Terra and Aqua MODIS BBs have displayed minimal drift over the mission lifetime, and the seasonal variations of the BB temperature are extremely small in Aqua MODIS. The long-term gain and noise equivalent difference in temperature performance of the 160 TEB detectors on both MODIS instruments have been well behaved and generally very stable. Small but noticeable variations of Aqua MODIS bands 33-36 (13.34-14.24 micrometer) response in recent years are primarily due to loss of temperature control margin of its passive cryoradiative cooler. As a result, fixed calibration coefficients, previously used by bands when the BB temperature is above their saturation temperatures, are replaced by the focal-plane-temperature-dependent calibration coefficients. This paper presents an overview of the MODIS TEB calibration, the on-orbit performance, and the challenging issues likely to impact the instruments as they continue operating well past their designed lifetime of six years.

TEBs↗

Computational Thermal Hydraulics of a High-Performance Low-Enriched-Uranium Annular Target for HFIR Irradiation

Molybdenum-99 has historically been generated via isolation from fissioned highly enriched uranium (HEU) targets. Here, this isotope is in high demand due to its daily use across the world in radiopharmaceutical medical procedures. The primary objective of this work was to design and analyze an experimental target assembly containing one low-enriched-uranium (LEU) annular target for irradiation at the High Flux Isotope Reactor (HFIR). Efforts included incorporating spatially dependent energy sources from neutron and gamma interactions, quantifying thermal contact conductance at material interfaces, performing grid-independent studies, comparing turbulence models, and simulating various steady-state and transient scenarios relevant for irradiation qualification and eventual insertion. These models provide velocity, pressure, and temperature distributions in both space and time. Such results enable the selection of an appropriate irradiation location, fission rate density, and flow-limiting orifice size and demonstrate compliance with HFIR safety requirements such that insertion into the reactor can be approved. This analysis shows that across all scenarios, wetted surface temperatures remain below the coolant saturation temperature with no net vapor formation in the coolant. In every scenario, all components stay below 30% of the aluminum 6061 melting temperature. Computational fluid dynamics and system-level models predict peak target temperatures that agree within 4%, though the predicted axial location of the peak differs by about 10% of the heated length due to differences in flow development length. These results de-risk the irradiation of LEU (annular targets) and strengthen a domestic, HEU-independent 99 Mo supply by providing important fuel performance data to form the foundation for a robust licensing basis.

Molybdenum-99↗

Evolution and use of combined mechanical and thermal codes for cryogenic turbopump bearings

Shaft bearing system analysis codes were developed, improved, and used to investigate Space Shuttle Main Engine (SSME) Liquid Oxygen (LOX) turbopump bearing problems, and to support the Marshall Space Flight Center Bearing and Seal Materials Test (BSMT) program. Thermal network modeling uses the SINDA thermal code, and the modeling of bearing quasi-dynamic characteristics uses the SHABERTH bearing/shaft code. These codes are solved concurrently for a bearing/shaft system using software developed for this purpose. Simulation of the SSME LOX turbopump turbine and pump end bearings and the MSFC BSMT operating in liquid nitrogen (LN sub 2) and LOX was done. The thermal network models include the bearing components, bearing carriers, shaft, housing, frictional heat, and viscous fluid energy. A cage model was included to account for heat generation between the cage and rolling elements. Since most bearing surfaces operate at temperatures well above the coolant saturation temperature, and move at high speed relative to the coolant, forced convection boiling is the dominant mechanism for heat removal. Improved modeling of forced convection film boiling was incorporated to take into account the local vapor generation at the high temperature surfaces. Rearing preloads in the pump and tester are provided by preload springs. As bearing operating clearances and contact angles change due to thermal effects and loading, the bearing preload changes with these varying conditions. These characteristics were modeled and are included in the overall system models. Results from these models indicate an operational limit which, if exceeded, predicts a thermal excursion.

Cody, Joe C.↗

Carbon Dioxide Convection in the Martian Polar Night and Its Implications for Polar Processes

Each Martian year nearly 30% of the atmosphere is exchanged with the polar ice caps. This exchange occurs through a combination of direct surface condensation and atmospheric precipitation of carbon dioxide. It has long been thought the amount of condensation within the polar night is maintained by a balance between diabatic processes such as radiative cooling and latent heating from condensing CO2. This assumption manifests itself in Mars General Circulation Models (GCM) in such a way as to never allow the atmospheric temperature to dip below the saturation temperature of CO2. However, observations from Mars Global Surveyor (MGS) Radio Science (RS) and the Thermal Emission Spectrometer (TES) have demonstrated this assumption to be, at best, approximate. Both RS and TES observations within the polar nights of both poles indicate substantial supersaturated regions with respect to CO2. The observed temperature profiles suggest conditionally unstable regions containing planetary significant amounts of potential convective energy. Presented here are estimates of the total planetary inventory of convective available potential energy (CAPE) and the potential convective energy flux (PCEF). The values for CAPE and PCEF are derived from RS temperature profiles and compared to Mars GCM results using a new convective CO2 cloud model that allows for the formation of CAPE.

Colaprete, A.↗

Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

Loop heat pipes (LHPs) have been used for thermal control of several NASA and commercial orbiting spacecraft. The LHP operating temperature is governed by the saturation temperature of its compensation chamber (CC). Most LHPs use the CC temperature for feedback control of its operating temperature. There exists a thermal resistance between the heat source to be cooled by the LHP and the LHP's CC. Even if the CC set point temperature is controlled precisely, the heat source temperature will still vary with its heat output. For most applications, controlling the heat source temperature is of most interest. A logical question to ask is: "Can the heat source temperature be used for feedback control of the LHP operation?" A test program has been implemented to answer the above question. Objective is to investigate the LHP performance using the CC temperature and the heat source temperature for feedback control

Ku, Jentung↗

Real-gas effects 1: Simulation of ideal gas flow by cryogenic nitrogen and other selected gases

The thermodynamic properties of nitrogen gas do not thermodynamically approximate an ideal, diatomic gas at cryogenic temperatures. Choice of a suitable equation of state to model its behavior is discussed and the equation of Beattie and Bridgeman is selected as best meeting the needs for cryogenic wind tunnel use. The real gas behavior of nitrogen gas is compared to an ideal, diatomic gas for the following flow processes: isentropic expansion; normal shocks; boundary layers; and shock wave boundary layer interactions. The only differences in predicted pressure ratio between nitrogen and an ideal gas that may limit the minimum operating temperatures of transonic cryogenic wind tunnels seem to occur at total pressures approaching 9atmospheres and total temperatures 10 K below the corresponding saturation temperature, where the differences approach 1 percent for both isentropic expansions and normal shocks. Several alternative cryogenic test gases - air, helium, and hydrogen - are also analyzed. Differences in air from an ideal, diatomic gas are similar in magnitude to those of nitrogen. Differences for helium and hydrogen are over an order of magnitude greater than those for nitrogen or air. Helium and hydrogen do not approximate the compressible flow of an ideal, diatomic gas.

Hall, R. M.↗

Simulation of ideal-gas flow by nitrogen and other selected gases at cryogenic temperatures

The real gas behavior of nitrogen, the gas normally used in transonic cryogenic tunnels, is reported for the following flow processes: isentropic expansion, normal shocks, boundary layers, and interactions between shock waves and boundary layers. The only difference in predicted pressure ratio between nitrogen and an ideal gas which may limit the minimum operating temperature of transonic cryogenic wind tunnels occur at total pressures approaching 9 atm and total temperatures 10 K below the corresponding saturation temperature. These pressure differences approach 1 percent for both isentropic expansions and normal shocks. Alternative cryogenic test gases were also analyzed. Differences between air and an ideal diatomic gas are similar in magnitude to those for nitrogen and should present no difficulty. However, differences for helium and hydrogen are over an order of magnitude greater than those for nitrogen or air. It is concluded that helium and cryogenic hydrogen would not approximate the compressible flow of an ideal diatomic gas.

Hall, R. M.↗

Evaluating the Calibration of Aqua MODIS Bands 33, 35, and 36 During Blackbody Warm-Up Cool-Down Events

Aqua MODIS is the second MODIS instrument of NASA's Earth Observation System and has operated for over sixteen years since its launch in 2002. MODIS has sixteen thermal emissive bands (TEBs) located on two separate cold focal plane assemblies (CFPA). The TEBs are calibrated every scan using observations of an onboard blackbody (BB) and a space view port. Low saturation temperatures (Tsat) of Aqua MODIS bands 33, 35, and 36 cause these bands to saturate when the BB temperature is higher than their Tsat values during a BB warm-up cool-down (WUCD) cycle, therefore impacting the ability to perform nominal calibration. In addition, starting from around 2006, the CFPA temperature showed gradual variation from its nominally-controlled operating temperature due to a loss of its radiative cooler margin and the magnitude of its fluctuation reaching a maximum in 2013. The MODIS Characterization Support Team currently uses a correction that is dependent on the CFPA temperature to provide a gain estimate for the saturated scans during the BB WUCD. This gain estimation has been implemented in the Aqua MODIS Collection 6 (C6) and C6.1 L1B products. This paper evaluates the quality of the calibrated radiance of Aqua MODIS bands 33, 35, and 36 using simultaneous nadir observations from the Atmospheric Infrared Sounder (AIRS), which is also onboard the Aqua satellite. Our analysis results show that the differences between AIRS and Aqua MODIS can be controlled well within the fluctuation range compared to the periods when the BB signals for these bands are not saturated.

Li, Yonghong↗

Tetragonal structure and uniaxial magnetic anisotropy in the arc-melted (Ce,Zr) 2 (Fe,M) 17 (M = Mo, W, Co) alloys

The tetragonal ThMn 12 -type structure is stabilized in (Ce 1-x Zr x ) 2 T 16 M (x = 0.2 – 0.3; T = Fe or Fe/Co, M = Mo or W) arc-melted alloys. Approximately 5 at% of Mo or W admixture is sufficient to transform the hexagonal Th 2 Ni 17 -type structure of (Ce 1-x Zr x ) 2 Fe 17 into the tetragonal ThMn 12 -type structure of nearly single-phase (Ce 1-x Zr x ) 2 Fe 16 M and/or (Ce 1-x Zr x ) 2 Fe 15 CoM bulk alloys. X-ray Rietveld refinements reveal that Zr and Mo (W) substitute different sites in the tetragonal crystal structure. Zirconium preferentially replaces Ce, whereas Mo (W) substitutes Fe. At room temperature, the tetragonal phases exhibit strong ferromagnetism and a uniaxial magneto-crystalline anisotropy with anisotropy fields of 15 – 17 kOe. These materials possess room-temperature saturation magnetizations of 95 – 105 emu/g and Curie temperature of 420 – 505 K. At some concentrations, concurrent Zr and Mo (W) site occupancy facilitates 1:12 structure formation in bulk alloys with minimal presence of non-magnetic element in the Fe sublattice, thus securing the highest known magnetic moment per Fe atom (∼ 1.37 µ B ) in this type of materials. The intrinsic magnetic characteristics, as well as the absence of critical rare earths (RE), make these compounds interesting for development as low-cost permanent magnets. In conclusion, small Co additions improve the Curie temperature, especially if combined with W.

36 MATERIALS SCIENCE↗

A phase-field method for boiling heat transfer

Here we present a phase field method for heat transfer in two-phase flow with boiling. The vapor/liquid interface evolution is modeled by the Cahn-Hilliard equation. The phase change rate is determined by accounting for the heat conduction balance on either vapor or liquid side of the interfacial area, depending on which side the temperature is assumed to be maintained at the saturation temperature during boiling. The velocity correction scheme proposed by Dong & Shen [27] is extended to solve the Navier-Stokes equations for a non-solenoidal velocity field, and the entropy viscosity method is employed for stabilization. The phase change model is verified by two-dimensional simulations of a vapor bubble growing in super-heated liquid and in film boiling. In both cases, mesh independence of the results is systematically performed. Subsequently, the method is applied to predict the growth of three-dimensional vapor bubble in a rectangular microchannel with boiling flow, achieving good agreement with experimental measurements and available simulation results using the level-set method. The numerical experiments demonstrate that the required mesh resolution for the phase field method is comparable with that of volume of fluid (VoF) and level-set methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of non-magnetic Cu on enhancing the low temperature magnetic properties and Curie temperature of FeCoNiCrCu(x) high entropy alloys

The microstructure and magnetic properties of three face-centered cubic (FCC) FeCoNiCrCu(x) high entropy alloys (HEAs) (x=0, 0.5, 1) are investigated. Interestingly, addition of the nonmagnetic element Cu to FeCoNiCr HEA is found to enhance exchange interactions and low temperature saturation magnetization. The paramagnetic to ferromagnetic Curie transition temperature increases from 85 K for FeCoNiCr to 118 K for FeCoNiCrCu. This is counterintuitive since Cu is nonmagnetic; however, atom probe tomography revealed Cu rich clusters containing 5 at% Ni and 1 at% each of Fe, Co, Cr, within FCC matrix, these clusters altered the matrix composition and consequently its magnetic properties.

Chaudhary, Varun↗

Carbon Dioxide Clouds at High Altitude in the Tropics and in an Early Dense Martian Atmosphere

We use a time dependent, microphysical cloud model to study the formation of carbon dioxide clouds in the Martian atmosphere. Laboratory studies by Glandor et al. show that high critical supersaturations are required for cloud particle nucleation and that surface kinetic growth is not limited. These conditions, which are similar to those for cirrus clouds on Earth, lead to the formation of carbon dioxide ice particles with radii greater than 500 micrometers and concentrations of less than 0.1 cm(exp -3) for typical atmospheric conditions. Within the current Martian atmosphere, CO2 cloud formation is possible at the poles during winter and at high altitudes in the tropics during periods of increased atmospheric dust loading. In both cases, temperature perturbations of several degrees below the CO2 saturation temperature are required to nucleate new cloud particles suggesting that dynamical processes are the most common initiators of carbon dioxide clouds rather than diabatic cooling. The microphysical cloud model, coupled to a two-stream radiative transfer model, is used to reexamine the impact of CO2 clouds on the surface temperature within a dense CO2 atmosphere. The formation of carbon dioxide clouds leads to a warmer surface than what would be expected for clear sky conditions. The amount of warming is sensitive to the presence of dust and water vapor in the atmosphere, both of which act to dampen cloud effects. The radiative warming associated with cloud formation, as well as latent heating, work to dissipate the clouds when present. Thus, clouds never last for periods much longer than several days, limiting their overall effectiveness for warming the surface. The time average cloud optical depth is approximately unity leading to a 5-10 K warming, depending on the surface pressure. However, the surface temperature does not rise about the freezing point of liquid water even for pressures as high as 5 bars, at a solar luminosity of 75% the current value.

Colaprete, Anthony↗

Implementation of Sub-Cooling of Cryogenic Propellants by Injection of Non-condensing Gas to the Generalized Fluid Systems Simulation Program (GFSSP)

Cryogenic propellants are readily heated when used. This poses a problem for rocket engine efficiency and effective boot-strapping of the engine, as seen in the "hot" LOX (Liquid Oxygen) problem on the S-1 stage of the Saturn vehicle. In order to remedy this issue, cryogenic fluids were found to be sub-cooled by injection of a warm non-condensing gas. Experimental results show that the mechanism behind the sub-cooling is evaporative cooling. It has been shown that a sub-cooled temperature difference of approximately 13 deg F below saturation temperature [1]. The phenomenon of sub-cooling of cryogenic propellants by a non-condensing gas is not readily available with the General Fluid System Simulation Program (GFSSP) [2]. GFSSP is a thermal-fluid program used to analyze a wide variety of systems that are directly impacted by thermodynamics and fluid mechanics. In order to model this phenomenon, additional capabilities had to be added to GFSSP in the form of a FORTRAN coded sub-routine to calculate the temperature of the sub-cooled fluid. Once this was accomplished, the sub-routine was implemented to a GFSSP model that was created to replicate an experiment that was conducted to validate the GFSSP results.

Huggett, Daniel J.↗

Numerical Simulation of Liquid Nitrogen Chilldown of a Vertical Tube

This paper presents the results of a one-dimensional numerical simulation of the transient chilldown of a vertical stainless steel tube with liquid nitrogen. The direction of flow is downward (with gravity) through the tube. Heat transfer correlations for film, transition, and nucleate boiling, as well as critical heat flux, rewetting temperature, and the temperature at the onset of nucleate boiling were used to model the convection to the tube wall. Chilldown curves from the simulations were compared with data from 55 recent liquid nitrogen chilldown experiments. With these new correlations the simulation is able to predict the time to rewetting temperature and time to onset of nucleate boiling to within 25% for mass fluxes ranging from 61.2 to 1150 kg/(sq m s), inlet pressures from 175 to 817 kPa, and subcooled inlet temperatures from 0 to 14 K below the saturation temperature.

GFSSP↗