Search NASA⌕ Search

SEARCH · Search NASA

Results for “separation instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Motion cue effects on pilot tracking

The results of two successive experimental investigations of the effects of motion cues on manual control tracking tasks are reported. The first of these was an IFR single-axis VTOL roll attitude control task. Describing function data show the dominant motion feedback quantity to be angular velocity. The second experimental task was multiaxis, that of precision hovering of a VTOL using separated instrument displays with reduced motion amplitude scaling. Performance data and pilot opinion show angular position to be the dominant cue when simulator linear motion is absent.

Ringland, R. F.↗

Preliminary design report, Large Space Telescope OTA/SI Phase B study: High speed area photometer

A photometer is examined which combines several features from separate instruments into a single package. The design presented has both point and area photometry capability with provision for inserting filters to provide spectral discrimination. The electronics provide for photon counting mode for the point detectors and both photon counting and analog modes for the area detector. The area detector also serves as a target locating device for the point detectors. Topics discussed include: (1) electronic equipment requirements, (2) optical properties, (3) structural housing for the instrument, (4) motors and other mechanical components, (5) ground support equipment, and (6) environment control for the instrument. Engineering drawings and block diagrams are shown.

Source record↗

An improved capillary rheometer

Capillary rheometer incorporates cone-tipped preheated piston to compress plastized coal sample through narrow tube. Applied force is proportional to viscosity and is recorded on separate instrument. Samples are heated rapidly due to large area of cone surface. Device, primarily applied in designing efficient equipment for feeding coal into combustion chamber, may be readily used in other viscosity studies.

Feinstein, S. P.↗

Purkinje image eyetracking: A market survey

The Purkinje image eyetracking system was analyzed to determine the marketability of the system. The eyetracking system is a synthesis of two separate instruments, the optometer that measures the refractive power of the eye and the dual Purkinje image eyetracker that measures the direction of the visual axis.

Christy, L. F.↗

The Gamma Ray Observatory - A new view of the violent universe

The Gamma Ray Observatory (GRO) has been undertaken by NASA to make the next major thrust in high-energy astrophysics. The GRO will be flown in a circular orbit at an altitude of 400 km with an inclination of 28.5 degrees. The Shuttle will take the GRO to its nominal orbit altitude. The GRO will be removed and will ascend to 400 km using its own propulsion system. The GRO will record and transmit data to the Tracking and Data Relay Satellite, which will then relay the signal to ground. The GRO will consist of four separate instruments that collectively span the photon spectrum from 0.05 to 30,000 MeV, almost six decades in energy. The photon sensitivity over the entire six-decade range will be improved by more than an order of magnitude over the best previously flown instruments. Significant improvements in angular resolution will also be made.

Kniffen, D. A.↗

Preparation and analysis of particulate metal deposits

Small particles and clusters of palladium were grown by deposition from the vapor phase under ultrahigh vacuum conditions. Amorphous and crystalline support films of Al2O3 and ultrathin amorphous carbon films were used as substrate materials. The growth of the metal deposit was monitored in situ by scanning transmission diffraction of energy-filtered 100 kV electrons and high resolution transmission electron microscopy (TEM) analysis was performed in a separate instrument. It was established by in situ TEM, however, that the transfer of specimens in this case did not unduly affect the size and distribution of deposit particles. It was found that the cleanness, stoichiometry, crystallinity and structural perfection of the support surface play an essential role in determining the crystalline perfection and structure of the particles. The smallest palladium clusters reproducibly prepared contained not more than six atoms but size determinations below 1 nm average particle diameter are very problematic with conventional TEM. Palladium particles grown on carbon supports feature an impurity-stabilized mosaic structure.

Poppa, H.↗

The impact of data density and data error on the evolution of mesoscale forecast error

The effects of data density and data errors on the accuracy of mesoscale weather forecasts were assessed by simulations of a period in February 1979 when a snowstorm occurred along the U.S. eastern seaboard. The simulations were initiated every 12 hr and the growth of the rms error was tracked as a function of time and varying data densities. A uniform grid of instrumentation separation and perfect boundary conditions were assumed for all the simulations. A bias error representation was defined to account for systematic measurement errors. A brief summary of features of the somewhat complex storm is provided, together with the parameters of the 11 different simulations with high, medium and low data densities. The accuracy of the forecasts were proportional to the data density, although the error decreased for all the simulations over a 24 hr period. The density of the vertical data had a significant impact on the accuracy of the forecast, whereas the horizontal data density did not. Finally, pathways by which errors were transferred among variables were identified.

Warner, T. T.↗

Lick Observatory charge-coupled-device data acquisition system

The Lick Observatory CCD data acquisition system is described, with some observational results to illustrate the system capability. The electronics for the CCD are subdivided into those attached to the dewar, a 'smart' controller near the dewar, and a computer connected by serial link to the smart controller. Software for the controller is in assembler code, while the software for data acquisition and on-line analysis is written in C and uses the UNIX operating system. The computers and controllers are programmed to recognize and operate several different types of CCD. Three separate instruments that use the CCDs are described briefly, together with examples of the data they produce.

Robinson, L. B.↗

In-situ detection of OH in the lower stratosphere with a balloon borne high repetition rate laser system

Midday stratospheric OH density measurements have been carried out within the altitude interval of 31 to 24 km using the laser-induced fluorescence technique deployed on a balloon-borne gondola launched from Palestine, Texas on July 15, 1987. Laser output at 282 nm is produced with a pulsed, 17 kHz repetition rate, copper vapor laser pumped tunable dye laser. The OH mixing ratio ranged from 16 + or - 5 ppt at 31 km to 4 + or - 3 ppt in the 27 to 24 km region. Simultaneous ozone and water vapor measurements were also obtained with separate instruments.

Stimpfle, R. M.↗

Operational requirements and the geostationary platform

For 22 years (from ATS-1 to GOES-H) a single technology has dominated imaging from geosynchronous altitudes. In 1990, with the scheduled launch of GOES-I, a major change will occur which will in turn open the way for the Geostationary Platform. The need for improved observations of severe storms has led NOAA to a decision to replace spinning geostationary spacecraft with a three-axis-stabilized type (non-spinning) vehicle already common among communications spacecraft and demonstrated by INSAT. Also, the current spin-scan imager with sounder channels will be replaced by separate instruments capable of independent aiming. The advantages and challenges of the changes are discussed.

Sparkman, James K., Jr.↗

Analysis of tethered balloon, ceilometer and class sounding data taken on San Nicolas Island during the FIRE project

During the FIRE Marine Stratocumulus Program on San Nicolas Island, Colorado State University (CSU) and the British Meteorological Office (BMO) operated separate instrument packages on the NASA tethered balloon. The CSU package contained instrumentation for the measurement of temperature, pressure, humidity, cloud droplet concentration, and long and short wave radiation. Eight research flights, performed between July 7 and July 14, are summarized. An analysis priority to the July 7, 8 and 11 flights was assigned for the purposes of comparing the CSU and BMO data. Results are presented. In addition, CSU operated a laser ceilometer for the determination of cloud base, and a CLASS radiosonde site which launched 69 sondes. Data from all of the above systems are being analyzed.

Schubert, Wayne H.↗

Gravity field error analysis: Applications of GPS receivers and gradiometers on low orbiting platforms

The concept of a Global Positioning System (GPS) receiver as a tracking facility and a gradiometer as a separate instrument on a low orbiting platform offers a unique tool to map the Earth's gravitational field with unprecedented accuracies. The former technique allows determination of the spacecraft's ephemeris at any epoch to within 3 to 10 cm, the latter permits the measurement of the tensor of second order derivatives of the gravity field to within 0.01 to 0.0001 Eotvos units depending on the type of gradiometer. First, a variety of error sources in gradiometry where emphasis is placed on the rotational problem pursuing as well a static as a dynamic approach is described. Next, an analytical technique is described and applied for an error analysis of gravity field parameters from gradiometer and GPS observation types. Results are discussed for various configurations proposed on Topex/Poseidon, Gravity Probe-B, and Aristoteles, indicating that GPS only solutions may be computed up to degree and order 35, 55, and 85 respectively, whereas a combined GPS/gradiometer experiment on Aristoteles may result in an acceptable solution up to degree and order 240.

Schrama, E.↗

Electric field measurements during supercharging events on the MAIMIK rocket experiment

Data are presented on the evolution of electric field structures near the MAIMIK mother-daughter tethered rocket during active electron emissions from the rocket, which consisted of two separately instrumented payload sections which were detached in-flight. The results of the E field data analysis show that the temporal behavior of the fields was consistent with ion responses to the rapid charging of the active payload. A qualitative model of the interaction between the active payload and the ambient plasma background is developed to explain the electric field data, including the apparent causal relationship between the radial and tangential impulse components.

Denig, W. F.↗

Gravity field error analysis - Applications of Global Positioning System receivers and gradiometers on low orbiting platforms

The concept of a Global Positioning System (GPS) receiver as a tracking facility and a gradiometer as a separate instrument on a low-orbiting platform offers a unique tool to map the earth's gravitational field with unprecedented accuracies. The former technique allows determination of the spacecraft's ephemeris at any epoch to within 3-10 cm, the latter permits the measurement of the tensor of second order derivatives of the gravity field to within 0.01 to 0.0001 Eotvos units depending on the type of gradiometer. First, a variety of error sources in gradiometry where emphasis is placed on the rotational problem pursuing as well a static as a dynamic approach is described. Next, an analytical technique is described and applied for an error analysis of gravity field parameters from gradiometer and GPS observation types. Results are discussed for various configurations proposed on Topex/Poseidon, Gravity Probe-B, and Aristoteles, indicating that GPS only solutions may be computed up to degree and order 35, 55, and 85, respectively, whereas a combined GPS/gradiometer experiment on Aristoteles may result in an acceptable solution up to degree and order 240.

Schrama, Ernst J. O.↗

On the potential of long wavelength imaging radars for mapping vegetation types and woody biomass in tropical rain forests

In the tropical rain forests of Manu, in Peru, where forest biomass ranges from 4 kg/sq m in young forest succession up to 100 kg/sq m in old, undisturbed floodplain stands, the P-band polarimetric radar data gathered in June of 1993 by the AIRSAR (Airborne Synthetic Aperture Radar) instrument separate most major vegetation formations and also perform better than expected in estimating woody biomass. The worldwide need for large scale, updated biomass estimates, achieved with a uniformly applied method, as well as reliable maps of land cover, justifies a more in-depth exploration of long wavelength imaging radar applications for tropical forests inventories.

Rignot, Eric J.↗

Visualization software for a global three-dimensional upper atmosphere model

A software environment has been developed to assist in analysis and visualization of numerical outputs from NCAR's thermospheric general circulation models. The codes produce vector graphics, raster imagery, and time dependent animation of model results, with provision for comparison with empirical models and relevant data from satellite and ground based instruments. Separate programs are executed on the NCAR CRAY YMP8/864 and HAO divisional Sun workstations, providing both large volume highspeed batch and custom interactive computing environments. The visualization system assembles a suite of existing software packages including NCAR Graphics, IDL, netCDF, and the Xt intrinsics library with the Athena widget set.

Foster, Benjamin T.↗

Vacuum Nuller Testbed (VNT) Performance, Characterization and Null Control: Progress Report

Herein we report on the development. sensing and control and our first results with the Vacuum Nuller Testbed to realize a Visible Nulling Coronagraph (VNC) for exoplanet coronagraphy. The VNC is one of the few approaches that works with filled. segmented and sparse or diluted-aperture telescope systems. It thus spans a range of potential future NASA telescopes and could be Hown as a separate instrument on such a future mission. NASA/Goddard Space Flight Center (GSFC) has a well-established effort to develop VNC technologies. and has developed an incremental sequence of VNC testbeds to advance this approach and the enabling technologies associated with it. We discuss the continued development of the vacuum Visible Nulling Coronagraph testbed (VNT). Tbe VNT is an ultra-stable vibration isolated testbed that operates under closed-loop control within a vacuum chamber. It will be used to achieve an incremental sequence of three visible-light nulling milestones with sequentially higher contrasts of 10(sup 8), 10(sup 9) and ideally 10(sup 10) at an inner working angle of 2*lambda/D. The VNT is based on a modified Mach-Zehnder nulling interferometer, with a "W" configuration to accommodate a hex-packed MEMS based deformable mirror, a coherent fiber bundle and achromatic phase shifters. We discuss the initial laboratory results, the optical configuration, critical technologies and the null sensing and control approach.

Lyon, Richard G.↗

High Contrast Vacuum Nuller Testbed (VNT) Contrast, Performance and Null Control

Herein we report on our contrast assessment and the development, sensing and control of the Vacuum Nuller Testbed to realize a Visible Nulling Coronagraphy (VNC) for exoplanet detection and characterization. Tbe VNC is one of the few approaches that works with filled, segmented and sparse or diluted-aperture telescope systems. It thus spans a range of potential future NASA telescopes and could be flown as a separate instrument on such a future mission. NASA/Goddard Space Flight Center has an established effort to develop VNC technologies, and an incremental sequence of testbeds to advance this approach and its critical technologies. We discuss the development of the vacuum Visible Nulling Coronagraph testbed (VNT). The VNT is an ultra-stable vibration isolated testbed that operates under closed-loop control within a vacuum chamber. It will be used to achieve an incremental sequence of three visible-light nulling milestones with sequentially higher contrasts of 10(exp 8), 10(exp 9) and ideally 10(exp 10) at an inner working angle of 2*lambda/D. The VNT is based on a modified Mach-Zehnder nulling interferometer, with a "W" configuration to accommodate a hex-packed MEMS based deformable mirror, a coherent fiber bundle and achromatic phase shifters. We discuss the laboratory results, optical configuration, critical technologies and the null sensing and control approach.

Lyon, Richard G.↗