Search NASA⌕ Search

SEARCH · Search NASA

Results for “sequencing test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Studies and simulations of the DigiCipher system

During this period the development of simulators for the various high definition television (HDTV) systems proposed to the FCC was continued. The FCC has indicated that it wants the various proposers to collaborate on a single system. Based on all available information this system will look very much like the advanced digital television (ADTV) system with major contributions only from the DigiCipher system. The results of our simulations of the DigiCipher system are described. This simulator was tested using test sequences from the MPEG committee. The results are extrapolated to HDTV video sequences. Once again, some caveats are in order. The sequences used for testing the simulator and generating the results are those used for testing the MPEG algorithm. The sequences are of much lower resolution than the HDTV sequences would be, and therefore the extrapolations are not totally accurate. One would expect to get significantly higher compression in terms of bits per pixel with sequences that are of higher resolution. However, the simulator itself is a valid one, and should HDTV sequences become available, they could be used directly with the simulator. A brief overview of the DigiCipher system is given. Some coding results obtained using the simulator are looked at. These results are compared to those obtained using the ADTV system. These results are evaluated in the context of the CCSDS specifications and make some suggestions as to how the DigiCipher system could be implemented in the NASA network. Simulations such as the ones reported can be biased depending on the particular source sequence used. In order to get more complete information about the system one needs to obtain a reasonable set of models which mirror the various kinds of sources encountered during video coding. A set of models which can be used to effectively model the various possible scenarios is provided. As this is somewhat tangential to the other work reported, the results are included as an appendix.

Sayood, K.↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 4 - Raw Data

Sequence 4: Static Pressure Calibration (P) This test sequence used a downwind, teetered turbine with a 3.4° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of 0° to 30° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. A static pitot probe was installed on a boom 2.3 m upwind of the nacelle at hub height and connected to the reference side of the Mensor digital differential pressure transducer through the pneumatic rotary coupling. This provided the reference pressure for all blade-mounted pressure transducers, as opposed to the NASA atmospheric pressure reference that was used for all other test sequences. This simulates the pressure system connections used in field measurements where the static pressure was unknown.

17 WIND ENERGY↗

Criteria for structural test

The results of a study to define criteria and techniques of design, analysis and test which permit the use of a single major structural test article for performing dynamic, fatigue, and static testing are presented. The criteria developed is applicable to both space vehicles and aircraft structures operating in the subsonic or supersonic regime. The feasibility of such an approach was demonstrated by defining test interactions, compatibilities and incompatibilities between the three different types of tests. The results of the study indicate that the single test article concept is feasible with a testing sequence of dynamic test followed by a fatigue and static test.

Source record↗

Track/train dynamics test report transfer function test. Volume 1: Test

A description is presented of the transfer function test performed on an open hopper freight car loaded with 80 tons of coal. Test data and a post-test update of the requirements document and test procedure are presented. Included are a statement of the test objective, a description of the test configurations, test facilities, test methods, data acquisition/reduction operations, and a chronological test summary. An index to the data for the three test configurations (X, Y, and Z-axis tests) is presented along with test sequence, run number, test reference, and input parameters.

Vigil, R. A.↗

Design, processing, and testing of LSI arrays for space station

The work on the Process Analysis Structure was continued with the layout being completed, the 100X and 10X artwork being finalized, and the process and test sequences being prepared. Test programs were written for computer-controlled integrated-circuit testing and data reduction.

Ipri, A. C.↗

Thermal performance testing of the Explorer Platform

The Explorer Platform (EP) has been designed to accommodate on-orbit payload and bus module changeout via Space Transportation System (STS) servicing. Such a versatile spacecraft platform designed to experience widely different environmental exposures and operational conditions, coupled with program constraints on schedule and budget, presented a challenge to implementing a technically sound thermal vacuum/thermal balance test program. This paper discusses thermal performance tests implemented at the subsystem and system levels, and the risks accepted resulting from test sequence, configuration. and tests omitted from the program. No thermal cycling or thermal balance tests were performed on the integrated spacecraft level, although both the Payload (EUVE) and Platform (EP) received independent testing. The decision to take this approach is discussed with respect to the thermal design and the associated risks taken to maintain budget and schedule.

Wasson, David↗

Qualification tests and electrical measurements: Practice and problems

As part of the Flat-Plate Solar Array Project, 138 different module designs were subjected to qualification tests. Electrical measurements were subjected on well over a thousand modules representing more than 150 designs. From this experience, conclusions are drawn regarding results and problems, with discussion of the need for change or improvement. The qualification test sequence incuded application of environmental and electrical stresses to the module. With few exceptions, the tests have revealed defects necessitation of environmental and electrical stresses to the module. With few exceptions, the tests have revealed defects necessitating module design or process changes. However, the continued need for these tests may be questioned on the basis of technical and logistical factors. Technically, the current test sequence does not cover all design characteristics, does not include all field conditions and is not known to represent the desired 30-year module life. Logistically, the tests are time-consuming and costly, and there is a lack of, fully qualified independent test organizations. Alternatives to the current test program include simplification based on design specification and site environment, and/or the use of warranties or other commercial practices.

Smokler, M. I.↗

Solid rocket booster thrust vector control V-2 off-nominal testing

The results of the V-2 off nominal test sequence performed on the space shuttle solid rocket booster thrust vector control (SRB TVC) system are reported. The TVC subsystem was subjected to 19 off nominal test conditions. The test sequence consisted of: 8 burp starts, 30 hot firings, 14 GN2 spin tests, and 3 servicing passive system tests. It is concluded that the TVC subsystem operated nominally in response to the given commands and test conditions. Test objectives, detail results, and data are included.

Pagan, B.↗

Improving solar panel durability through novel panel designs and advanced manufacturing equipment

Work in the project was spread across 4 main themes:1) Improved Understanding of Why Cracks Form and Cause Degradation in Solar Cells: We developed a finite element model which correlated well with experimental determined deflection vs load profiles and which predicted stress profiles vs load level and temperature. These profiles helped to guide brace designs and showed the high stress levels seen in the silicon near the interconnect wire locations as the temperature is cooled below -30C, likely forming "invisible" microcracks. Experiments showed how for polymer backsheet modules, a brief exposure to such low temperatures made modules extremely sensitive to propagation of these microcracks at relatively low load levels, and how thicker and softer encapsulant helped to reduce this crack sensitivity. We showed for some modules that most cracks that are seen under loading had their origin at short, hard to see, V-cracks from soldering damage, and how the shunting from cells with high densities of cracks reduces energy delivery more than Pmax. 2) Improved Durability Testing Methods With Respect to Cracked Cells: We lobbied the PV community throughout the project that IEC 61215 was insufficient to probe the sensitivity of module Pmax degradation due to cracks in that in did not have a test leg that included a crack creation step (static loading) followed by a crack opening step (cyclic loading and/or thermal cycling). We published extensively on how pre- existing cracks opened up with cyclic loading. The new IEC TS 63209-1 ED1 test sequence now include our recommendations, and this should lead to improved module designs and reduced risk for investors. We also published recommendations for a new "Cold Climate Test" sequence to probe the sensitivity of modules to degradation from short microcracks formed when modules see temperatures below -30C followed by front side loading. We participated in several USTAG meetings related to cracked cells, EL testing, and mechanical load testing and provided input to the group to improve new standards under consideration. We also showed how the act of performing an EL test can affect the test results due to heating from the injected current. 3) New Module Designs and Related Manufacturing Methods & Equipment: We demonstrated reduced crack sensitivity on encapsulated cell coupons the benefits of building protective compressive stress into the cells by laminating them in a bent state and then allowing the coupon to flatten out after lamination. Our attempts to scale this to the module level with a more manufacturable sequence did not demonstrate the same positive effects, but we hope that others will follow up with other variations on this bent lamination or bent cooling concept to make more durable modules. 4) New Module Mounting Designs: We explored a range of bracing concepts which pressed on the backsheet to slightly bow the glass outward and place cells in a state of protective compressive stress and to reduce the deflection under front side loads. These successfully reduced cell cracking and crack opening, but high static loads permanently deformed cost-effective braces, after which they provided little benefit. We settled on an elegant & effective solution – the RailPad, where lightweight bracing elements are placed between the mounting rail(s) and the backsheet, and the existing strength of the rails is used to prevent module deflection under load. New construction and retrofit designs were made, and test sites were implemented in FL and MA. We applied for RailPad patent protection.

14 SOLAR ENERGY↗

RSRM top hat cover simulator lightning test, volume 1

The test sequence was to measure electric and magnetic fields induced inside a redesigned solid rocket motor case when a simulated lightning discharge strikes an exposed top hat cover simulator. The test sequence was conducted between 21 June and 17 July 1990. Thirty-six high rate-of-rise Marx generator discharges and eight high current bank discharges were injected onto three different test article configurations. Attach points included three locations on the top hat cover simulator and two locations on the mounting bolts. Top hat cover simulator and mounting bolt damage and grain cover damage was observed. Overall electric field levels were well below 30 kilowatts/meter. Electric field levels ranged from 184.7 to 345.9 volts/meter and magnetic field levels were calculated from 6.921 to 39.73 amperes/meter. It is recommended that the redesigned solid rocket motor top hat cover be used in Configuration 1 or Configuration 2 as an interim lightning protection device until a lightweight cover can be designed.

Source record↗

Rheoencephalographic and electroencephalographic measures of cognitive workload: analytical procedures

This investigation demonstrates the feasibility of mental workload assessment by rheoencephalographic (REG) and multichannel electroencephalographic (EEG) monitoring. During the performance of this research, unique testing, analytical and display procedures were developed for REG and EEG monitoring that extend the current state of the art and provide valuable tools for the study of cerebral circulatory and neural activity during cognition. REG records are analyzed to provide indices of the right and left hemisphere hemodynamic changes that take place during each test sequence. The EEG data are modeled using regression techniques and mathematically transformed to provide energy-density distributions of the scalp electrostatic field. These procedures permit concurrent REG/EEG cognitive testing not possible with current techniques. The introduction of a system for recording and analysis of cognitive REG/EEG test sequences facilitates the study of learning and memory disorders, dementia and other encephalopathies.

Arousal/physiology↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence G - Raw Data

Sequence G: Upwind Teetered (F) Test sequence G used an upwind, teetered turbine with a 0° cone angle. The wind speeds ranged from 5 m/s to 25 m/s. Yaw angles of ±180° were achieved at low wind speeds and angles of ±10° were achieved at the high wind speeds. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence M - Raw Data

Sequence M: Transition Fixed (P) Test sequence M used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 15 m/s. Yaw angles ranged from 0° to 90°. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read –99999.99. Zigzag tape was installed near the leading edge of the instrumented blade on both the upper and lower surfaces as described in Appendix K. In addition to the standard 30-second campaigns, yaw sweeps were done at 7 m/s and 10 m/s. These 90-second campaigns were collected while the yaw drive rotated the turbine 90° at a rate of 1°/s. The file names for these campaigns use the letter designation, followed by two digits for wind speed, followed by YSU, followed by 00.

17 WIND ENERGY↗

A simulation-based fault injection experiment to evaluate self-test diagnostics for a fault-tolerant computer

The design and results of a fault injection experiment conducted in the Airlab facility at NASA-Langley using a logic network simulator are described. An attempt was made to determine the effectiveness of the diagnostic self-test sequences used to detect failures in the communicator/interstage (C/I) of a fault-tolerant processor (FTP). Identification of the undetected faults in the C/I Status Register logic resulted in changes in the diagnostic test sequences implemented for the FTP.

Baker, Robert L.↗

Fuel Property Effects on Stochastic Preignition Events During Engine Load Transitions

Stochastic preignition (SPI) is an abnormal combustion phenomenon that can cause catastrophic engine damage. There have been several proposed mechanisms of SPI, where a uniform source is still not certain, however, SPI tendencies have been shown to be influenced by engine operating conditions, oil composition, engine age, and fuel chemical and physical properties. Laboratory research and testing for SPI propensity is challenging given the stochastic nature of events, as well as the potential for significant degradation of the engine platform and measuring equipment over time. Thus, SPI specific experiments are generally conducted under either sustained or cyclic patterning of steady-state operating conditions to avoid the influence of transient engine boundary conditions on test parameters of interest (e.g. oil additive package, fuel properties, engine speed/load, etc.). In this work a cyclically varying SPI test sequence involves a 5 min engine warmup period at a low engine load of around 4 bar gross indicated mean effective pressure (IMEPg), followed by a transition to high load (~20 bar IMEPg) at a constant 2000 rev/min engine speed for a total of 25 min. This individual test sequence load schedule is then sequentially repeated 10 times to generate significant statistical data for analysis. This work examines the influence of fuel chemical and physical properties on SPI tendency during the unsteady portion of the 10-cycle sequence (the first 5 min of the high load operation in each sequence of the loading cycle) which has been discarded from previous analyses due to the uncertainty in engine operating and thermal boundary conditions. Results from this analysis suggest an increasing trend in the ratio of SPI events during the unsteady test period relative to the steady test period with increasing fuel Reid Vapor Pressure (RVP), implying differences in uncontrolled ignition source terms, possibly from, fuel wall interactions and retention during the load transition phase of the test.

Splitter, Derek [ORNL] (ORCID:0000000174044047)↗

Sequential Testing Algorithms for Multiple Fault Diagnosis

In this paper, we consider the problem of constructing optimal and near-optimal test sequencing algorithms for multiple fault diagnosis. The computational complexity of solving the optimal multiple-fault isolation problem is super-exponential, that is, it is much more difficult than the single-fault isolation problem, which, by itself, is NP-hard. By employing concepts from information theory and AND/OR graph search, we present several test sequencing algorithms for the multiple fault isolation problem. These algorithms provide a trade-off between the degree of suboptimality and computational complexity. Furthermore, we present novel diagnostic strategies that generate a diagnostic directed graph (digraph), instead of a diagnostic tree, for multiple fault diagnosis. Using this approach, the storage complexity of the overall diagnostic strategy reduces substantially. The algorithms developed herein have been successfully applied to several real-world systems. Computational results indicate that the size of a multiple fault strategy is strictly related to the structure of the system.

Shakeri, Mojdeh↗

Sequential Test Strategies for Multiple Fault Isolation

In this paper, we consider the problem of constructing near optimal test sequencing algorithms for diagnosing multiple faults in redundant (fault-tolerant) systems. The computational complexity of solving the optimal multiple-fault isolation problem is super-exponential, that is, it is much more difficult than the single-fault isolation problem, which, by itself, is NP-hard. By employing concepts from information theory and Lagrangian relaxation, we present several static and dynamic (on-line or interactive) test sequencing algorithms for the multiple fault isolation problem that provide a trade-off between the degree of suboptimality and computational complexity. Furthermore, we present novel diagnostic strategies that generate a static diagnostic directed graph (digraph), instead of a static diagnostic tree, for multiple fault diagnosis. Using this approach, the storage complexity of the overall diagnostic strategy reduces substantially. Computational results based on real-world systems indicate that the size of a static multiple fault strategy is strictly related to the structure of the system, and that the use of an on-line multiple fault strategy can diagnose faults in systems with as many as 10,000 failure sources.

Shakeri, M.↗