Search NASA⌕ Search

SEARCH · Search NASA

Results for “solid-state sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Engineering diamond interfaces free of dark spins

Nitrogen-vacancy (NV) centers in diamond are utilized extensively as quantum sensors for imaging fields at the nanoscale. The ultrahigh sensitivity of NV magnetometers has enabled the detection and spectroscopy of individual electron spins, with potentially far-reaching applications in condensed matter physics, spintronics, and molecular biology. However, the surfaces of these diamond sensors naturally contain electron spins, which create a background signal that can be hard to differentiate from the signal of the target spins. In this study, we develop a surface modification approach that eliminates the unwanted signal of these so-called dark electron spins. Our surface passivation technique, based on coating diamond surfaces with a thin titanium oxide (Ti⁢O 2 ) layer, reduces the dark spin density. The observed reduction in dark spin density aligns with our findings on the electronic structure of the diamond-Ti⁢O 2 interface. The reduction, from a typical value of 2000 μm −2 to a value below that set by the detection limit of our NV sensors (200 μm −2 ), results in a twofold increase in Hahn-echo coherence time of near surface NV centers. Furthermore, we derive a comprehensive spin model that connects dark spin relaxation with NV coherence, providing additional insights into the mechanisms behind the observed spin dynamics. Our findings are directly transferable to other quantum platforms, including nanoscale solid-state qubits and superconducting qubits.

74 ATOMIC AND MOLECULAR PHYSICS↗

A solid state multispectral imager.

Photodiode arrays used as image sensors in satellite remote imaging systems offer the advantages of geometric accuracy, precise registration of scene elements, enhanced operational reliability, and wide spectral response. Principles of photodiode-array operation are reviewed, and the latest developments in self-scanned array chip technology are described along with optical system requirements for multispectral coverage. Results of development efforts with a spaceborne solid-state multispectral camera based on linear sensing array technology are outlined to demonstrate the capabilities of this approach to multispectral sensing.

Green, A.↗

PyJMAK: An Open-Source Python Toolkit for Modeling Solid-State Metallurgical Phase Transformations

Accurate prediction of metallurgical phase transformations is an essential basis for autonomous optimization and rapid part qualification. Several methods can be used to estimate the evolution of phase fractions such as JMAK kinetics-based models, phase-field models, thermodynamic models, and data-driven machine learning models. Thermodynamic and phase-field-based methodologies solve multiphysics equations requiring numerous calibration parameters and significant computational resources. As a result, the computation domain is limited to a point or on order of micron-meters. The data-driven models rely on large datasets from experiments and simulations. While the JMAK model only provides information about phase fraction evolution, it can predict this evolution in near real-time using thermal history and thermodynamic data without restriction on the domain. JMAK models have been popularly used by researchers to model phase transformations occuring during additive manufacturing or over arbitrary temperature profiles. Commercial proprietary software such as Abaqus and Ansys or closed-source in-house implementations offer the ability to model JMAK based kinetics to predict phase transformation. However, these software packages are not open-source or freely available for use and development in conjunction with manufacturing machines, sensors, and machine learning algorithms. In addition, the use of the model is restricted by a license token. In contrast, given temperature profiles at multiple points in the domain, this Python-based PyJMAK model can compute phase evolution in parallel due to its stand-alone modular, voxel-based structure, and it can be executed on high-performance computing resources without any license restrictions.

Prabhune, Bhagya [Oak Ridge National Laboratory (O↗

SENSEI at SNOLAB: Single-Electron Event Rate and Implications for Dark Matter

We present results from data acquired by the SENSEI experiment at SNOLAB after a major upgrade in May 2023, which includes deploying 16 new sensors and replacing the copper trays that house the CCDs with a new light-tight design. We observe a single-electron event rate of (1.39±0.11)×10^{-5} e^{-}/pix/day, corresponding to (39.8±3.1) e^{-}/gram/day. This is an order-of-magnitude improvement compared to the previous lowest single-electron rate in a silicon detector and the lowest for any photon detector in the wavelength range between near-infrared and ultraviolet. We use these data to obtain a 90% confidence level upper bound of 1.53×10^{-5} e^{-}/pix/day and to set constraints on sub-GeV dark matter candidates that produce single-electron events. We hypothesize that the data taken at SNOLAB in the previous run, with an older tray design for the sensors, contained a larger rate of single-electron events due to light leaks. We test this hypothesis using data from the SENSEI detector located in the MINOS cavern at Fermilab.

dark matter↗

Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC

Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.

47 OTHER INSTRUMENTATION↗

Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam

Here, we present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20-μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized n + sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron–Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A sub-5 ps jitter time-to-digital converter ASIC with back-gate delay tuning in 22 nm CMOS

We present the design of a Time-to-Digital Converter (TDC) ASIC together with performance characterization results at cryogenic temperature (6-8 K), and at room temperature using emulated Low-Gain Avalanche Detector (LGAD) signals. The TDC design uses a two-step architecture with a ring-oscillator based counter and a Vernier delay line fine TDC. The TDC is implemented in an FD-SOI process, and back-gate tuning is used not only to correct threshold variation due to cryogenic operation, but also as a novel way to tune TDC delay elements with very little overhead. Using this technique, we demonstrate a design with very low power (0.5 mW) and area (0.003 mm 2 ). We present test results using the Fermilab Constant Fraction Discriminator (FCFD) ASIC to produce discriminated signals from an internal charge injection mechanism that mimics the waveform and signal amplitude of minimum ionizing particles impinging on LGAD sensors. We characterize the time precision of the full system and verify that the TDC ASIC contributes a negligible amount to the total system time precision, fully consistent with the expected jitter contribution of less than 5 ps. In conclusion, the results presented here demonstrate the utility of our TDC for applications in physics and quantum communications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diabatization with Electrostatic Embedding for Studying Photophysics in Organic Molecular Crystals

Highly emissive organic molecular crystals find applications in several areas, such as organic electronics, solar cells, and sensors. Understanding the excited-state mechanisms underlying these applications is essential for optimizing and controlling them effectively. Exciton models coupled with nonadiabatic dynamics, particularly quantum dynamics, provide crucial insights into photochemical and photophysical processes in molecular crystals. Nevertheless, there remains a lack of general tools and automated workflows to facilitate such simulations. In this paper, we present a computational strategy to investigate the photoactivated dynamics of organic molecular crystals, bridging methodologies traditionally used for molecular systems and materials science, with a particular focus on the interplay between local excitations and charge transfer (CT) processes. We have implemented an interface between the fromage and Overdia programs, enabling the construction of vibronic Hamiltonians for molecular crystals within an excited-state ONIOM(QM:QM′) framework, incorporating long-range electrostatics through a RESP-based Ewald summation. Fragment-based diabatization provides a route to quantum dynamics simulations in weak-to-intermediate coupling regimes. The method was applied to the photophysics of dibenzo[g,p]chrysene (DBC) crystals using time-dependent DFT. The fromage/ Overdia interface was employed to compute the couplings of local excitations and CT states for 18 unique DBC dimers in the crystal and to quantify the influence of electrostatic embedding, which was found to be modest (10−20%). Simulations on π-stacked dimers reproduced the small red shift observed experimentally from solution to crystal, attributed to electronic interactions among fixed monomers rather than crystal electrostatics. Quantum dynamics simulations revealed ultrafast population transfer from bright local excitations to CT states. This approach establishes a robust framework linking molecular and solid-state excited-state dynamics, with potential applications for studying excitations, defects, and impurities in molecular crystals.

Crystals↗

Ionic-Based Electrochemical Gas Sensors for Low-Cost, High-Sensitivity SO2 Detection

Sulfur dioxide (SO2) is a toxic gas associated with adverse health and environmental effects that necessitate reliable monitoring techniques. Here, we report the development of an all-solid-state electrochemical sensor utilizing a lithium borate (Li3BO3) solid electrolyte capable of subppm of SO2 detection. While subppm of SO2 sensing has been previously demonstrated in other solid-state electrolyte systems─such as stabilized zirconia, natrium super ionic conductors (NASICON) under mixed-potential conditions─here we establish Li3BO3 as an alternative solid electrolyte enabling equilibrium potentiometric sensing in an all-solid architecture. This sensor demonstrates a detection limit of at least 0.25 ppm, surpassing the human-olfactory threshold and meeting the rigorous requirements for industrial and personal monitoring applications. The sensing mechanism relies on the formation of Li2SO4 on the electrode surface, as evidenced by multimodal characterization techniques, including Raman spectroscopy, scanning electron microscopy (SEM), and scanning transmission electron microscopy (STEM). The strong linear correlation between the open-circuit potential (OCV) and the logarithm of SO2 concentration between 0.25 and 2 ppm indicates that the response is Nernstian in nature.

Lagunas, Francisco (ORCID:000000026377683X)↗

Event-driven readout development: testing of the EDWARD65P1 chip with integrated event generators

Building on a prototype readout integrated circuit for segmented silicon sensors with the EDWARD event-driven readout architecture, the front-end in each pixel was replaced by a hardware generator to verify readout performance, ensuring no data loss, consistent priority handling, and speed verification. Here, this generator produces Poisson-distributed readout requests with individually tunable rates per pixel via a digitally controlled oscillator. The resulting EDWARD65P1 test ASIC is a 32×32 pixel matrix with a 100 μm pitch, equipped with digital event generators simulating radiation hits at user-defined rates. Test results for this new design are presented.

47 OTHER INSTRUMENTATION↗

Quality concerns caused by quality control — deformation of silicon strip detector modules in thermal cycling tests

The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35 °C (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector's operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35 °C and +40 °C are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure.

47 OTHER INSTRUMENTATION↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

Silicon wafer fracture stress for tracking sensors in particle physics experiments

For the construction of the ATLAS Inner Tracker strip detector, silicon strip sensor modules are glued directly onto carbon fibre support structures using a soft silicone gel. During tests at temperatures below -35°C, several of the sensors were found to crack due to a mismatch in coefficients of thermal expansion between polyimide circuit boards with copper metal layers (glued onto the sensor) and the silicon sensor itself. While module assembly procedures were developed to minimise variations between modules, cold tests showed a wide range of temperatures at which supposedly comparable modules failed. The observed variance (fracture temperatures between -35°C and -70°C) for supposedly comparable modules suggests an undetected variation between modules suspected to be intrinsic to the silicon wafer itself. Therefore, a test programme was developed to investigate the fracture stress of representative sensor wafer cutoffs. This paper presents results for the fracture stress of silicon sensors used in detector modules.

Detector design and construction technologies and ↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

First Limits on Light Dark Matter Interactions in a Low Threshold Two-Channel Athermal Phonon Detector from the TESSERACT Collaboration

We present results of a search for spin-independent dark matter-nucleus interactions in a 1 cm 2 by 1 mm thick (0.233 g) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves an rms baseline energy resolution of 361.5⁢(4) m⁢ eV (statistical error), the best for any athermal phonon detector to date. With an exposure of 0.233 g ×12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 M⁢ eV/c 2 , with the lowest unexplored cross section of 4⁢ × 10 −32 c⁢m 2 at 87 M⁢ eV/c 2 . We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low energy backgrounds that are coupled to individual sensors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Developmental solid-state imaging system.

Developmental imaging system for NASA solid state TV camera, describing sensor matrix fabrication and interrogation system mechanization for image readout

Anders, R. A.↗

Solid-state turn coordinator display

A solid state turn coordinator display which employs light emitting diodes (LED's) as the display medium was developed to demonstrate the feasibility of such displays for aircraft applications. The input to the display is supplied by a fluidic inertial rate sensor used in an aircraft wing leveler system. The display is composed of the LED radial display face and the electronics necessary to address and drive the individual lines of LED's. Three levels of brightness are provided to compensate for the different amounts of ambient light present in the cockpit.

Meredith, B. D.↗