Search NASA⌕ Search

SEARCH · Search NASA

Results for “sparse reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Sparse matrix wavefront reconstruction: simulations and experiments

Adaptive optics systems with Shack-Hartmann wavefront sensors require reconstruction of the atmospheric phase error from slope measurements, with every sensor in the array being used in the computation of each actuator command. This fully populated reconstruction matrix can result in a significant computational burden for adaptive optics systems with large numbers of actuators. A method for generating sparse wavefront reconstruction matrices for adaptive optics isproposed. The method exploits the relevance of nearby slope measurements for control of an individual actuator, and relies upon the limited extent of the influence function for a zonal deformable mirror. Relying only on nearby sensor information can significantly reduce the calculation time for wavefront reconstruction. In addition, a hierarchic controller is proposed to recover some of the global wavefront information. The performance of these sparse wavefront reconstruction matrices was evaluated in simulation, and tested on the Palomar Adaptive Optics System. This paper will present some initial results from the simulations and experiments.

space↗

Path-Based Dictionary Augmentation: A Framework for Improving $k$ -Sparse Image Processing

In this study, we have previously shown that augmenting orthogonal matching pursuit (OMP) with an additional step in the identification stage of each pursuit iteration yields improved $k$ -sparse reconstruction and denoising performance relative to baseline OMP. At each iteration a “path” or geodesic, is generated between the two dictionary atoms that are most correlated with the residual and from this path a new atom that has a greater correlation to the residual than either of the two bracketing atoms is selected. Here, we provide new computational results illustrating improvements in sparse coding and denoising on canonical datasets using both learned and structured dictionaries. The two methods of constructing a path are investigated for each dictionary type: the Euclidean geodesic formed by a linear combination of the two atoms and the 2-Wasserstein geodesic corresponding to the optimal transport map between the atoms. We prove here the existence of a higher-correlation atom in the Euclidean case under assumptions on the two bracketing atoms and introduce algorithmic modifications to improve the likelihood that the bracketing atoms meet those conditions. Although, we demonstrate our augmentation on OMP alone, in general it may be applied to any reconstruction algorithm that relies on the selection and sorting of high-similarity atoms during an analysis or identification phase.

97 MATHEMATICS AND COMPUTING↗

MO-DE-207A-11: Sparse-View CT Reconstruction Via a Novel Non-Local Means Method

Purpose: Sparse-view computed tomography (CT) reconstruction is an effective strategy to reduce the radiation dose delivered to patients. Due to its insufficiency of measurements, traditional non-local means (NLM) based reconstruction methods often lead to over-smoothness in image edges. To address this problem, an adaptive NLM reconstruction method based on rotational invariance (RIANLM) is proposed. Methods: The method consists of four steps: 1) Initializing parameters; 2) Algebraic reconstruction technique (ART) reconstruction using raw projection data; 3) Positivity constraint of the image reconstructed by ART; 4) Update reconstructed image by using RIANLM filtering. In RIANLM, a novel similarity metric that is rotational invariance is proposed and used to calculate the distance between two patches. In this way, any patch with similar structure but different orientation to the reference patch would win a relatively large weight to avoid over-smoothed image. Moreover, the parameter h in RIANLM which controls the decay of the weights is adaptive to avoid over-smoothness, while it in NLM is not adaptive during the whole reconstruction process. The proposed method is named as ART-RIANLM and validated on Shepp-Logan phantom and clinical projection data. Results: In our experiments, the searching neighborhood size is set to 15 by 15 and the similarity window is set to 3 by 3. For the simulated case with a resolution of 256 by 256 Shepp-Logan phantom, the ART-RIANLM produces higher SNR (35.38dB<24.00dB) and lower MAE (0.0006<0.0023) reconstructed image than ART-NLM. The visual inspection demonstrated that the proposed method could suppress artifacts or noises more effectively and preserve image edges better. Similar results were found for clinical data case. Conclusion: A novel ART-RIANLM method for sparse-view CT reconstruction is presented with superior image. Compared to the conventional ART-NLM method, the SNR and MAE from ART-RIANLM increases 47% and decreases 74%, respectively.

60 APPLIED LIFE SCIENCES↗

Inverse transport problem solvers based on regularized and compressive sensing techniques

According to the direct exposure measurements from flash radiographic image, regularized-based method and compressive sensing (CS)-based method for inverse transport equation are presented. The linear absorption coefficients and interface locations of objects are reconstructed directly at the same time. With a large number of measurements, least-square method is utilized to complete the reconstruction. Owing to the ill-posedness of the inverse problems, regularized algorithm is employed. Tikhonov method is applied with an appropriate posterior regularization parameter to get a meaningful solution. However, it's always very costly to obtain enough measurements. With limited measurements, CS sparse reconstruction technique Orthogonal Matching Pursuit (OMP) is applied to obtain the sparse coefficients by solving an optimization problem. This paper constructs and takes the forward projection matrix rather than Gauss matrix as measurement matrix. In the CS-based algorithm, Fourier expansion and wavelet expansion are adopted to convert an underdetermined system to a well-posed system. Simulations and numerical results of regularized method with appropriate regularization parameter and that of CS-based agree well with the reference value, furthermore, both methods avoid amplifying the noise. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

X-ray computed tomography using curvelet sparse regularization

Purpose: Reconstruction of x-ray computed tomography (CT) data remains a mathematically challenging problem in medical imaging. Complementing the standard analytical reconstruction methods, sparse regularization is growing in importance, as it allows inclusion of prior knowledge. The paper presents a method for sparse regularization based on the curvelet frame for the application to iterative reconstruction in x-ray computed tomography. Methods: In this work, the authors present an iterative reconstruction approach based on the alternating direction method of multipliers using curvelet sparse regularization. Results: Evaluation of the method is performed on a specifically crafted numerical phantom dataset to highlight the method’s strengths. Additional evaluation is performed on two real datasets from commercial scanners with different noise characteristics, a clinical bone sample acquired in a micro-CT and a human abdomen scanned in a diagnostic CT. The results clearly illustrate that curvelet sparse regularization has characteristic strengths. In particular, it improves the restoration and resolution of highly directional, high contrast features with smooth contrast variations. The authors also compare this approach to the popular technique of total variation and to traditional filtered backprojection. Conclusions: The authors conclude that curvelet sparse regularization is able to improve reconstruction quality by reducing noise while preserving highly directional features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP1-09: Modality-Specific Dose Gradient Modeling for Prostate IMRT Using Spherical Distance Maps of PTV and Isodose Contours

Purpose: Overlapping volume histogram (OVH) and distance-to-target histogram (DTH) calculations rely on the assumption that dose gradients are symmetric with respect to primary target volume (PTV) expansion and minimum distance to PTV surface, respectively. It is desirable to lift this assumption and instead account for achievable modality-specific dose gradients (MSDG) for a given PTV shape. Methods: From a library of 96 prostate 7-beam IMRT plans, we computed spherical distance maps (SDMs) for PTVs and 3 iso-dose contours. Each SDM contains the minimum distances between plan isocenter and the object’s surface for a fixed set of azimuthal and polar angles. We performed principal component analysis (PCA)-based missing data recovery with PTV SDM as input and a single iso-dose contour SDM as output. Repeating this process for the set of iso-dose contours sparsely reconstructed the MSDG for a given PTV. DVH points were computed from the MSDG for bladder and rectum (OARs) as a natural way of casting patient-specific geometric information into modality-specific dose space (vs. OVH and DTH where data is purely geometric). For comparison, we implemented a cumulative (c)DTH-based prediction algorithm, and produced DVH for both OARs separately. We then computed linear regressions between each method and the DVH of the original patient plan for three different OAR DVH points. Results: R-squared for MSD-Gcomputed DVH vs. original plan DVH at V90%, V80% and V60% of max dose were 0.86, 0.83, and 0.78, for bladder and 0.36, 0.52, and 0.55 for rectum, respectively; R-squared for cDTH-based predicted DVH vs. original plan DVH were 0.67, 0.81, and 0.83, for bladder and 0.44, 0.50, and 0.51, for rectum, respectively. Conclusion: By simply modeling the MSDG about a given PTV, we are able to reproduce DVHs consistent with a validated cDTH-based DVH prediction. Regression analysis suggests MSDG could further improve predictions.

60 APPLIED LIFE SCIENCES↗

Sparse coding of pathology slides compared to transfer learning with deep neural networks

Background Histopathology images of tumor biopsies present unique challenges for applying machine learning to the diagnosis and treatment of cancer. The pathology slides are high resolution, often exceeding 1GB, have non-uniform dimensions, and often contain multiple tissue slices of varying sizes surrounded by large empty regions. The locations of abnormal or cancerous cells, which may constitute a small portion of any given tissue sample, are not annotated. Cancer image datasets are also extremely imbalanced, with most slides being associated with relatively common cancers. Since deep representations trained on natural photographs are unlikely to be optimal for classifying pathology slide images, which have different spectral ranges and spatial structure, we here describe an approach for learning features and inferring representations of cancer pathology slides based on sparse coding. Results We show that conventional transfer learning using a state-of-the-art deep learning architecture pre-trained on ImageNet (RESNET) and fine tuned for a binary tumor/no-tumor classification task achieved between 85% and 86% accuracy. However, when all layers up to the last convolutional layer in RESNET are replaced with a single feature map inferred via a sparse coding using a dictionary optimized for sparse reconstruction of unlabeled pathology slides, classification performance improves to over 93%, corresponding to a 54% error reduction. Conclusions We conclude that a feature dictionary optimized for biomedical imagery may in general support better classification performance than does conventional transfer learning using a dictionary pre-trained on natural images.

59 BASIC BIOLOGICAL SCIENCES↗

Kalman-filtered compressive sensing for high resolution estimation of anthropogenic greenhouse gas emissions from sparse measurements.

The estimation of fossil-fuel CO2 emissions (ffCO2) from limited ground-based and satellite measurements of CO2 concentrations will form a key component of the monitoring of treaties aimed at the abatement of greenhouse gas emissions. The limited nature of the measured data leads to a severely-underdetermined estimation problem. If the estimation is performed at fine spatial resolutions, it can also be computationally expensive. In order to enable such estimations, advances are needed in the spatial representation of ffCO2 emissions, scalable inversion algorithms and the identification of observables to measure. To that end, we investigate parsimonious spatial parameterizations of ffCO2 emissions which can be used in atmospheric inversions. We devise and test three random field models, based on wavelets, Gaussian kernels and covariance structures derived from easily-observed proxies of human activity. In doing so, we constructed a novel inversion algorithm, based on compressive sensing and sparse reconstruction, to perform the estimation. We also address scalable ensemble Kalman filters as an inversion mechanism and quantify the impact of Gaussian assumptions inherent in them. We find that the assumption does not impact the estimates of mean ffCO2 source strengths appreciably, but a comparison with Markov chain Monte Carlo estimates show significant differences in the variance of the source strengths. Finally, we study if the very different spatial natures of biogenic and ffCO2 emissions can be used to estimate them, in a disaggregated fashion, solely from CO2 concentration measurements, without extra information from products of incomplete combustion e.g., CO. We find that this is possible during the winter months, though the errors can be as large as 50%.

Ray, Jaideep↗

MO-FG-204-08: Optimization-Based Image Reconstruction From Unevenly Distributed Sparse Projection Views

Purpose: Optimization-based reconstruction has been proposed and investigated for reconstructing CT images from sparse views, as such the radiation dose can be substantially reduced while maintaining acceptable image quality. The investigation has so far focused on reconstruction from evenly distributed sparse views. Recognizing the clinical situations wherein only unevenly sparse views are available, e.g., image guided radiation therapy, CT perfusion and multi-cycle cardiovascular imaging, we investigate the performance of optimization-based image reconstruction from unevenly sparse projection views in this work. Methods: The investigation is carried out using the FORBILD and an anthropomorphic head phantoms. In the study, 82 views, which are evenly sorted out from a full (360°) axial CT scan consisting of 984 views, form sub-scan I. Another 82 views are sorted out in a similar manner to form sub-scan II. As such, a CT scan with sparse (164) views at 1:6 ratio are formed. By shifting the two sub-scans relatively in view angulation, a CT scan with unevenly distributed sparse (164) views at 1:6 ratio are formed. An optimization-based method is implemented to reconstruct images from the unevenly distributed views. By taking the FBP reconstruction from the full scan (984 views) as the reference, the root mean square (RMS) between the reference and the optimization-based reconstruction is used to evaluate the performance quantitatively. Results: In visual inspection, the optimization-based method outperforms the FBP substantially in the reconstruction from unevenly distributed, which are quantitatively verified by the RMS gauged globally and in ROIs in both the FORBILD and anthropomorphic head phantoms. The RMS increases with increasing severity in the uneven angular distribution, especially in the case of anthropomorphic head phantom. Conclusion: The optimization-based image reconstruction can save radiation dose up to 12-fold while providing acceptable image quality for advanced clinical applications wherein only unevenly distributed sparse views are available. Research Grants: W81XWH-12-1-0138 (DoD), Sinovision Technologies.

60 APPLIED LIFE SCIENCES↗

Reconstruction Techniques for Sparse Multistatic Linear Array Microwave Imaging

Sequentially-switched linear arrays are an enabling technology for a number of near-field microwave imaging applications. Electronically sequencing along the array axis followed by mechanical scanning along an orthogonal axis allows dense sampling of a two-dimensional aperture in near real-time. In this paper, a sparse multi-static array technique will be described along with associated Fourier-Transform-based and back-projection-based image reconstruction algorithms. Simulated and measured imaging results are presented that show the effectiveness of the sparse array technique along with the merits and weaknesses of each image reconstruction approach.

concealed-weapon detection↗

Image Reconstruction from Sparse-view Data Acquired with Portable X-ray Devices

• Portable X-ray systems enable on-site 3D imaging for non-invasive inspection of suspicious packages and explosives. • Existing reconstruction algorithms (e.g., FDK or Feldkamp, Davis and Kress) require hundreds of projections over 360 degrees. • Sparse-view scan reduces scanning time and setup effort, making it ideal for field use in time&#x2;critical scenarios. • Existing reconstruction algorithms introduce severe artifacts when applied to sparse-view data. • We developed a total variation (TV)-based optimization algorithm for yielding 3D images from sparse-view data collected with our portable X-ray imaging system.

Xia, Dan [University of Chicago, Chicago, IL]↗

SU-E-J-128: 3D Surface Reconstruction of a Patient Using Epipolar Geometry

Purpose: To obtain a 3D surface data of a patient in a non-invasive way can substantially reduce the effort for the registration of patient in radiation therapy. To achieve this goal, we introduced the multiple view stereo technique, which is known to be used in a 'photo tourism' on the internet. Methods: 70 Images were taken with a digital single-lens reflex camera from different angles and positions. The camera positions and angles were inferred later in the reconstruction step. A sparse 3D reconstruction model was locating by SIFT features, which is robust for rotation and shift variance, in each image. We then found a set of correspondences between pairs of images by computing the fundamental matrix using the eight-point algorithm with RANSAC. After the pair matching, we optimized the parameter including camera positions to minimize the reprojection error by use of bundle adjustment technique (non-linear optimization). As a final step, we performed dense reconstruction and associate a color with each point using the library of PMVS. Results: Surface data were reconstructed well by visual inspection. The human skin is reconstructed well, althogh the reconstruction was time-consuming for direct use in daily clinical practice. Conclusion: 3D reconstruction using multi view stereo geometry is a promising tool for reducing the effort of patient setup. This work was supported by JSPS KAKENHI(25861128)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sparse sampling and reconstruction for electron and scanning probe microscope imaging

Systems and methods for conducting electron or scanning probe microscopy are provided herein. In a general embodiment, the systems and methods for conducting electron or scanning probe microscopy with an undersampled data set include: driving an electron beam or probe to scan across a sample and visit a subset of pixel locations of the sample that are randomly or pseudo-randomly designated; determining actual pixel locations on the sample that are visited by the electron beam or probe; and processing data collected by detectors from the visits of the electron beam or probe at the actual pixel locations and recovering a reconstructed image of the sample.

74 ATOMIC AND MOLECULAR PHYSICS↗