Search NASA⌕ Search

SEARCH · Search NASA

Results for “stainless-steel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Heat load measurements for the PIP-II pHB650 cryomodule

Phase-3 testing of the pHB650 cryomodule at the PIP-II Injector Test Facility was conducted to evaluate the effectiveness of heat load mitigations performed after earlier phases of testing and to continue pinpointing any sources of unexpectedly high heat loads.. The programme measured HTTS, LTTS, and 2 K isothermal/non-isothermal loads under "standard", "linac", and "simulated dynamic" operating modes, recording data both inside the cryomodule and across the bayonet can circuits. Thermal-acoustic oscillations were eliminated by replacing the original G10 cooldown-valve stem with a stainless-steel stem fitted with wipers. A newly developed Python script automated acquisition of ACNET data, performed real-time heat-load calculations, and generated plots and tables that were posted to the electronic logbook within minutes, vastly reducing manual effort and accelerating feedback between SRF and cryogenics teams. Analysis showed that JT heat-exchanger effectiveness and temperature stratification in the two-phase and relief piping strongly influence the observed loads and helped isolate sources of excess heat. The campaign demonstrates that rigorous pre-test planning, real-time diagnostics, and automated reporting can improve both accuracy and efficiency, providing a template for future PIP-II cryomodule tests and for implementing targeted heat-load mitigations.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.] (ORCID:↗

Measurement of Transverse Resistance for Stacks of Non-insulated REBCO Tapes

Transverse resistance among adjacent conductors is a key parameter to calculate AC losses in superconducting cables with non-insulated conductors. The transverse pressure insert (TPI) previously developed and used at Fermilab was modified to measure transverse resistance of stacks made of non-insulated REBCO tapes as a function of transverse pressure at liquid nitrogen temperature. Pressure up to 322 MPa was applied with a hydraulic cylinder. A small current up to 10 A was flown in the stack sample through REBCO tape leads spliced above and below the stack. The latter had a bending radius larger than 6 mm to prevent the critical current degradation in REBCO leads. The voltage was measured just outside the compressed area. Stack samples included stacks of bare 4-mm wide REBCO tapes, as well as REBCO tapes alternated with 4-mm wide stainless-steel ribbons of 40 μm and 30 μm of thickness. We herein present the results of these transverse resistance measurements. Results show a stronger dependence on pressure for smaller pressure vs. larger ones. Also, of the two components of contact resistance, i.e. contact and bulk, the latter was negligible.

Tamagnini, E. [Turin Polytechnic]↗

Integrating Metal-Hydride and Gas-Detector for Tritium Gas Detection

Detection of trace amounts of environmental tritium is a challenging problem, driving the need for field-deployable systems that offer high sensitivity, selectivity, and minimal false positives. We present a technique for high-sensitivity, high-selectivity tritium measurement, which integrates metal-hydride and gas-detector concepts into a compact field-deployable tritium sensor. A hydrogen-storage metal embedded in a gas proportional counter selectively absorbs protium (1H)/tritium (3H), which are subsequently released into the counter volume with a reduced radiation background. Ionizations induced by 3H beta particles are then measured in proportional counting mode, achieving high detection efficiency. Preliminary studies conducted with palladium (Pd) thin films coated on stainless-steel substrates demonstrated 3H absorption and metal-tritide formation, followed by 3H desorption upon heating the metal-tritide. These processes were confirmed using activity concentrations measured by a commercial tritium monitor and pulse height spectra acquired from a custom-built detector.

Gas-proportional counter↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Towards Portable Laser Desorption Postionization Mass Spectrometry Utilizing Microchip Laser Pulses

A 355 nm, 1.5 ns, up to 1 kHz microchip laser system has been tested to both yield ablation spots and postionize material within a plasma plume. A 30 µJ pulse energy microchip laser successfully ablated all samples: 6601 aluminum, 316 and 304 stainless steel, and Mo metal. While visible ablation craters were observed on all samples mentioned above, the stainless-steel samples displayed visible color changes in the resolidified iron, indicating ionization with the 355 nm pulses during ablation. Additionally, when used to intercept a plasma plume of Cs 2 CO 3 made with a separate laser system, the microchip laser pulses yielded Cs + emission signal otherwise not observed. With these experiments completed, the microchip laser has been successfully verified for readiness to be integrated into the front end of a mass spectrometer system as the ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser Confocal Microscopy Uncertainty Quantification Study

At Los Alamos National Laboratory (LANL), the Storage Safety and Engineering (SSE) team completes annual surveillance on a subset of in-use interim nuclear material storage containers in fulfilment of requirements outlined in DOE Manual M 441.1-1. The containers are selected through several methods, such as subject matter expert judgement, random selection, and trending items. Following these selections, the SSE team has the capacity to complete surveillance on 15-20 containers each fiscal year, composed of a combination of SAVY-4000 and Hagan storage containers. Through previous work, the stainless-steel components of the containers have been identified as life limiting components, with an emphasis on the thin-walled bodies. The team is focused on understanding the extent of general and pitting corrosion, due to observations of extensive corrosion from stored contents and bag-out-bag degradation. Quantifying corrosion effects on the thin-walled stainless steel container bodies, and understanding potential impacts to the respective design release rates and design qualification release rates is paramount to the team. To date, destructive examination (DE) has proven to be the most insightful method for developing an understanding on the extent of corrosion on used containers. To standardize this process, the SSE team developed a destructive examination guide for analyzing stainless steel components of the containers. Corroded containers of interest are identified during surveillance activities and set aside for sectioning and characterization. Following sectioning, a major step in the DE workflow is the utilization of laser confocal microscopy for scanning corroded samples of interest and extracting data on pits, such as count, depth, and equivalent diameter. Adhering to the techniques outlined in the DE guide, analysis has been completed on two Hagans and one SAVY-4000 container, with the maximum pit depth recorded as 139.1 ± 22.82 μm on a 17.5 year old Hagan. The findings from the completed destructive examinations will be utilized to support lifetime extension efforts of the SAVY-4000 as the team can better estimate corrosion rates and effects over time based on stored contents and age. Due to the implications of observing extreme pit depths that approach the nominal container body thickness of .0299 inches (0.759 mm) or minimum container thickness of 0.236” (0.6 mm), high confidence in the LCM measurements is desired. Through testing outlined in, it was concluded that the total error ascribed to the 20x objective when conducting large image mapping on the Keyence VK-X3050 laser confocal microscope (LCM) relative to a 50x objective (reference) is 16.4% (± 8.73%). For shallow features on the order of pristine SAVY surface defects (i.e. 5 μm), this uncertainty is appropriate. However, this conservative estimate of total error poses a fundamental concern for pit depths that approach the thickness of the measured samples. That is, with the measurement uncertainty currently employed on all measurements, the LCM would be unable to resolve if a pit with a depth of 515 μm is through wall. Standard step height samples were procured and used in the present study to assess the resolution and repeatability of height measurements. Understanding the resolution and repeatability of height measurements was the first focus of the team as it relates directly to pit depth, which is of primary concern. Calibration gratings were procured to evaluate the resolution and repeatability of measurements in the X and Y axes of the LCM stage. The results of the depth uncertainty study were conducted first and presented in the subsequent sections. The planar uncertainty study is appended to the depth study with conclusions from both summarized at the end of the report.

36 MATERIALS SCIENCE↗

Demonstration of Electroreduction Technology to Convert GNF Uranium Oxide Powder to Metal

Global Nuclear Fuel – Americas LLC (GNF) has partnered with Argonne National Laboratory to demonstrate electroreduction of uranium oxides produced by deconversion of UF 6 to uranium metal through the Gateway for Accelerated Innovation in Nuclear (GAIN) program under the U.S. Department of Energy to accelerate the domestic production of metallic advanced reactor fuels. Electroreduction of uranium oxide was first demonstrated and patented by Argonne in the early 2000s as a technology to convert used oxide nuclear fuel from light water reactors to metal for further fuel reprocessing. More recently, electroreduction has been proposed as a front-end technology for metallization of uranium oxides produced by deconversion of UF 6 and for scrap recovery of oxide materials. During the electroreduction process, UO 2 powder is contained in a stainless-steel mesh basket with a cathode lead located in the center of the UO 2 bed. The basket is immersed in lithium chloride molten salt electrolyte containing 1 wt% lithium oxide along with a platinum anode and a nickel/nickel oxide (Ni/NiO) reference electrode. Current is applied to the cell between the cathode and anode to reduce the UO 2 to metallic uranium via a solid-state reduction reaction. Oxide ions released from the UO 2 during reduction are transported through the salt to the anode where oxygen gas is evolved. Once reduction is complete, the basket containing the metallicized uranium is removed from the salt and can be processed to remove the salt and consolidate the uranium into an ingot for use in metallic fuel fabrication. This project was performed to provide evidence of the electroreduction technology readiness level for metallization of UO 2 powder, identify and retire technical risks for industrialization of electroreduction, and accelerate the path to commercialization for metallic fast reactor fuel production. To that end, five electroreduction tests were performed with UO 2 provided by GNF and the resulting product was analyzed for the extent of conversion to metal and for impurity contents of the metal product to verify that electroreduction does not introduce impurities that would prevent use of the product in metallic fuel fabrication.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Pu Solubility in Glass for Sludge Batch 11

Stainless-steel clad Pu from Japan’s Fast Critical Assembly (FCA) reactor is currently being dispositioned at the Savannah River Site. The electrolytic dissolver, operated by Savannah River Nuclear Solutions in H-Canyon, is being utilized to dissolve the material. The resulting solutions are transferred to the Concentration, Storage, and Transfer Facilities, operated by Savannah River Mission Completion (SRMC), for subsequent vitrification at the Defense Waste Processing Facility (DWPF). In support of the FCA mission startup, a preliminary evaluation was conducted by the Savannah River National Laboratory to assess the impact of the FCA discards on the liquid waste system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving ICARUS Track Reconstruction Algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino (SBN) program at Fermilab. The main goal of the experiment is to investigate the possibility of sterile neutrinos in the O(1 eV) mass region and provide clarification of the anomaly detected from the Liquid Scintillator Neutrino Detector (LSND) and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber (LAr-TPC), that can provide excellent 3D imaging and calorimetric reconstruction of any ionizing particles. This detection technique allows a detailed study of neutrino interactions, spanning a wide energy spectrum (from a few keV to several hundreds of GeV). The detector consists of two identical adjacent modules, filled with a total of 760 tons of ultra-pure liquid argon. Each module houses two LAr-TPCs separated by a common cathode with a maximum drift distance of 1.5 m, equivalent to about 1 ms drift time for the nominal $500$ V/m electric drift field. The anode is made of three parallel wire planes positioned 3 mm apart, where the stainless-steel wires are oriented on each plane at a different angle with respect to the horizontal direction ($+60^\degree$,$-60^\degree$,$0^\degree$). The first two planes (Induction 1 and Induction 2) provide a non-destructive charge measurement, whereas the ionization charge is fully collected by the last collection plane. In total, 53248 wires with a 3 mm pitch and length up to 9 m are installed in the detector. In the first stage of the reconstruction, segments of waveforms corresponding to physical signals (hits) are searched for in the deconvolved wire waveform with a threshold-based hit-finding algorithm. Each hit is then fitted with a Gaussian, whose area is proportional to the number of drift electrons generating the signal. In the second stage of the reconstruction, hits are passed as input to Pandora, a framework software composed of different pattern recognition algorithms, that performs a 3D reconstruction of the full image recorded in the collected event, including the identification of interaction vertices and tracks and showers inside the TPC. These are organized into a hierarchical structure (called slice) of particles generated starting from a primary interaction vertex. In some cases, related to the inefficiencies in the hit detection or excessive deflection of the particle trajectory, Pandora breaks the particle's track into two or more smaller pieces and considers each piece as an independent track. We studied this phenomenon focusing on primary muons from ν_μ CC interactions contained in a single module with a track at least 20 cm long, to exclude delta rays. The study determined that about $7-8\%$ of the muon tracks are broken. Approximately $80\%$ of the times, Pandora assigns all segments of the track to the same slice (intra-slice track split), while in the remaining $20\%$ of the cases, one of the segments is associated with another slice (extra-slice track split). To mitigate this phenomenon, we designed an algorithm that detects and stitches the tracks broken by Pandora for the intra-slice split. In Monte Carlo simulations, the algorithm showed an efficiency exceeding $80\%$ and a purity exceeding $93\%$.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Mk-IV Salt Crystallization Hot Finger Apparatus for Partitioning Used Electrorefiner Salt

Electrorefining is a controlled redox process used to regulate the behavior of ionic species. Through this process, metals can be deposited onto a cathode from an electrolyte solution in a controlled manner. The Mk-IV electrorefiner (Mk-IV ER) at Idaho National Laboratory is an engineering-scale, molten salt-based electrorefining cell that has been used for decades to recover metallic uranium from spent fuel. As a result, highly stable fission product chlorides have accumulated in the electrolyte. This accumulation results in changes to the salt’s properties, such as melting temperature, thermal conductivity, and density, as well as elevated product impurity and fissile materials criticality margin. These factors prompt the need for a salt regeneration process, such as melt-crystallization and species drawdown. This work focuses on providing a conceptual design to regenerate ER salt from used Mk-IV-ER salt in-situ, while minimizing salt waste volumes by concentrating the fission products in a final processed salt heal. We propose using a hot-finger crystallization apparatus design to fractionally crystallize salt in the Mk-IV-ER head space (or baffle space), allowing the collection of solid and liquid fractions. By using a cup-drain design, the used salt will be allowed to slowly solidify on the walls of a stainless-steel cup. The apparatus drain plug will then open to allow the liquid salt phase to drain to a lower cup, effectively separating the liquid phase from the solid phase. Under the hypothesis that the liquid phase salt concentrates the fission products, which is under examination in the accompanying work package, this separation allows the recovered solid salt to be reused while minimizing the high-level salt waste volume of used ER salt.

36 - MATERIALS SCIENCE↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

The daily as-run thermal analysis for the Advanced Gas Reactor (AGR)-5/6/7 experiment was documented in ECAR-5633 (Hawkes 2021). A finite element model was created for the entire test train, which consisted of five capsules. The fuel compacts, graphite holders, stainless-steel capsule walls, and all other major components were individually modeled, including all thermocouples (TCs). Daily heat rates for each compact and component in the model were input from daily as-run physics analyses. Daily gas compositions for each capsule were also input. The thermal conductivity of the compacts and graphite holders varied with fast neutron fluence. Gas mixture thermal conductivity was implemented using experimentally attained values from the literature. Fluence and temperature-dependent thermal conductivity was used for the graphite components and the fuel compacts. Radiation heat transfer was implemented. The model was tuned in an attempt to match the TC readings during the first cycle by adjusting the Neolube (graphite lubricant) thickness.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Irradiation Experiment Fission Product Mass Balance

This report presents the fission product mass balance for the AGR-5/6/7 TRISO fuel irradiation experiment. The fission product inventories deposited on capsule components outside of the fuel (e.g., stainless-steel shells, graphite holders, Grafoil disks, and associated hardware) were quantified as part of the post-irradiation examination (PIE) to assess the performance of this fuel. Comparisons were made between these inventories and depletion calculations, non-destructive measurements of fuel fission product inventories in the intact fuel compacts, prior AGR experiments, and results from among each of the five distinct AGR-5/6/7 capsules. The data served as estimates of the condensable fission products released from the fuel during irradiation. Excluding Capsule 1 (which experienced accidental damage during irradiation) and Capsule 3 (which was tested at very high irradiation temperatures of >1300°C), the results indicate that the AGR-5/6/7 fuel performed comparably to fuel from earlier AGR experiments. The mass balance results were also used to estimate the number of particles with in-pile SiC failures. Subject to the assumptions made in these estimates, and excluding Capsules 1 and 3, the in-pile SiC failure rates for AGR-5/6/7 are comparable to those observed in AGR-2.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiolytic Gas Generation and Pressure Buildup in a Closed System Containing Mo-99 Solution

This study measured radiolytic gas generation and pressure buildup in a sealed stainless-steel system containing alkaline Mo-99 solution with added sodium nitrate as a hydrogen suppressant. In each of two experiments, approximately 200 Ci of Mo-99 solution was transferred into a closed experimental vessel inside a hot cell, isolated, and monitored for pressure rise caused by gas generation during radioactive decay. After pressure buildup, headspace gas samples were collected and analyzed by mass spectrometry to determine hydrogen and oxygen concentrations. The purpose was to quantify the magnitude of pressure buildup in a closed system and to characterize the gas composition produced by radiolysis of the Mo-99 target solution under representative handling and storage conditions. The two experiments used similar total Mo-99 activity but differed in solution volume, headspace volume, and leak integrity. In the first experiment, 197.5 Ci of Mo-99 in 16.92 mL of solution was loaded into a vessel with a 31.1-mL headspace; a small leak was later identified, and the measured peak pressure of 46 psig was extrapolated to about 70 psig in the absence of leakage. The headspace gas from this experiment contained about 21.4% H2 and 63.4% O2, but the composition was influenced by preferential hydrogen loss through the leak. In the second experiment, 193 Ci of Mo-99 in 5.41 mL of solution with 0.46 g NaNO3 was loaded into a vessel with a larger 42.61 mL headspace, and no detectable leak was observed. This experiment reached a peak pressure of 38 psig, and the measured gas composition was approximately 28.2% H2 and 51.5% O2. Because the second experiment was leak-free, it is considered the more reliable indicator of the true pressure buildup and intrinsic radiolytic gas composition of the Mo-99 solution.

Chemerisov, Sergey D.↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Impact of Irradiation on Corrosion Performance of Hybrid Organic/Inorganic Coatings on Austenitic Stainless Steel

The effects of gamma radiation on the performance of two corrosion-resistant coatings applied to stainless-steel 304L (SS304L) surfaces are presented. Specifically, the ability of the coatings to mitigate corrosion of SS304L surfaces as a function of the dose received (0–1300 Mrad) and dose rate (176 compared to 1054 rad/s) is evaluated using electrochemical methods, spectroscopy, and microscopy. Coating A, an organic/inorganic hybrid coating consisting of a two-part silica ceramic component and a polymer linker was evaluated in comparison to Coating B, which utilized Coating A as a topcoat for a commercial, off-the-shelf, Zn-rich primer. Post irradiation, Coating A demonstrated some corrosion protection following exposure to low levels of gamma radiation, but coating degradation occurred with an increased exposure dose and resulted in isolated regions of corrosion initiation. For Coating B, greater corrosion resistance was observed compared to Coating A due to the sacrificial nature of the Zn at elevated doses of gamma radiation. No effect of the dose rate (for the single dose examined) was observed for either coating. It is proposed for Coating B that as the polymer coating thermally degrades above 250 °C (bond scission of the polymer occurs), the remaining Zinc layer adhered to the SS304L post-irradiation enables enhanced corrosion resistance as compared to Coating A, which displays solely polymer degradation. The results presented herein establish an understanding of coating behavior with radiation exposure, specifically the relationship between corrosion coating performance and radiation dose, and can inform ageing and lifetime management for various applications.

degradation↗

Effect of sintering temperature on adhesion of spray-on piezoelectric transducers

Conventionally sol-gel spray-on transducers require a high-temperature (> 700 ◦C) sintering process; however, this process can affect the microstructure of the substrate material. For mechanical elbows and valves utilized for fluid transport in the energy sector, the components are designed to have a specific microstructure, and deviations from these specifications can create weak points in the system. For this reason it is important to investigate how the temperature of the deposition process affects the substrate. This paper investigates the effect of high-temperature and low-temperature (< 150 ◦C) processing conditions on the surface composition of the substrate. Furthermore, the resultant transducers from high- and low-temperature fabrication processes are compared to determine if a low-temperature processing method is feasible. For these studies a sol-gel spray-on process is employed to deposit piezoelectric ceramics onto a stainless-steel 316L substrate. Energy-dispersive X-ray spectroscopy is utilized to determine the composition of the substrate surface before and after transducer deposition. Results indicate that the high-temperature processing conditions may alter the surface composition of the metal due to a diffusion of the metal into the ceramic, which results in a metal surface that is bonded to the ceramic. Furthermore, it is shown that low-temperature processing of spray-on transducers is a viable method for transducer fabrication where the resultant transducers meet the industry minimum requirement of 30 dB signalto-noise ratio. In parallel simulation calculations, finite-element method (FEM) studies were performed to model the adhesive strength of the low-temperature processed transducer to the substrate surface. Comparisons between the simulations and experiments suggest that the bond strength is much greater than the commercial gel bonds and closer to hardened epoxy glue bonds. These results indicate that spray-on transducers fabricated under lowtemperature processing conditions are a viable solution for leave-in-place monitoring of structures.

M. Sinding, Kyle↗

Determining Drying Conditions to Mitigate Hanford Transfer Line Corrosion

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site.1,2,3 The underground transfer lines are used to transfer the waste between the tanks and other assets at the Hanford tank farm facilities. The transfer lines constructed before 1990 are pipe-in-pipe design with most of the lines having carbon steel carrier pipe and carbon steel encasements. The lines constructed after 1990 have a stainless-steel carrier with a carbon steel encasement. The carrier lines, which are in contact with the waste, provide a critical confinement function, while the encasements provide secondary containment to reduce the risk of a release and contamination to the environment. In 2022, a visual inspection of the annulus between the encasement and the carrier for one of the pre-1990 transfer lines revealed standing liquid in contact with the carrier pipe. Additionally, a significant build-up of corrosion products on the exterior of the carrier pipe and the interior of the encasement pipe was observed. To assess the extent of condition, borescope inspections were performed in the encasement space of additional transfer lines in the facility to provide a baseline. The inspection revealed that of the lines inspected, 29 had either moisture present or evidence that moisture had been present in the past (e.g., waterline corrosion where the pipe had been exposed to standing water). Additional inspections indicated several instances of pitting corrosion on the interior of the encasement and exterior the carrier transfer lines. An image of the carrier pipe with several pits is presented in Figure 1(a) and the profiled image of the transfer line section along with the pit depths are presented Figure 1(b). As seen in the figure, the deepest pit was 73 mils on the pipe section. These lines were designated as “do-not-use” until further compensatory actions are implemented to return the lines to service.

Shukla, Pavan K. [Savannah River National Laborato↗

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho Na- tional Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1000 hours, as a test of detrimental, long-term effects of heat pipe operation. The setup consists of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic fiber heater configuration and cooled via a water-cooled calorimeter. Measurements include temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, this data is utilized to validate heat pipe models in the heat pipe application Sockeye, which is based upon the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment in SPHERE using various heat pipe models with Sockeye, including heat conduction-based models and compressible flow models of the heat pipe interior. These models are compared to the experimental data to assess the accuracy of several aspects of heat pipe modeling, including frozen startup, the effect of non-condensable gases, and the coupling of the heat pipe to its environment.

97 - MATHEMATICS AND COMPUTING↗