Search NASA⌕ Search

SEARCH · Search NASA

Results for “standardization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

InterCarb: A Community Effort to Improve Interlaboratory Standardization of the Carbonate Clumped Isotope Thermometer Using Carbonate Standards

Abstract Increased use and improved methodology of carbonate clumped isotope thermometry has greatly enhanced our ability to interrogate a suite of Earth‐system processes. However, interlaboratory discrepancies in quantifying carbonate clumped isotope (Δ 47 ) measurements persist, and their specific sources remain unclear. To address interlaboratory differences, we first provide consensus values from the clumped isotope community for four carbonate standards relative to heated and equilibrated gases with 1,819 individual analyses from 10 laboratories. Then we analyzed the four carbonate standards along with three additional standards, spanning a broad range of δ 47 and Δ 47 values, for a total of 5,329 analyses on 25 individual mass spectrometers from 22 different laboratories. Treating three of the materials as known standards and the other four as unknowns, we find that the use of carbonate reference materials is a robust method for standardization that yields interlaboratory discrepancies entirely consistent with intralaboratory analytical uncertainties. Carbonate reference materials, along with measurement and data processing practices described herein, provide the carbonate clumped isotope community with a robust approach to achieve interlaboratory agreement as we continue to use and improve this powerful geochemical tool. We propose that carbonate clumped isotope data normalized to the carbonate reference materials described in this publication should be reported as Δ 47 (I‐CDES) values for Intercarb‐Carbon Dioxide Equilibrium Scale.

58 GEOSCIENCES↗

A Life Study of Ausforged, Standard Forged and Standard Machined AISI M-50 Spur Gears

Tests were conducted at 350 K (170 F) with three groups of 8.9 cm (3.5 in.) pitch diameter spur gears made of vacuum induction melted (VIM) consumable-electrode vacuum-arc melted (VAR), AISI M-50 steel and one group of vacuum-arc remelted (VAR) AISI 9310 steel. The pitting fatigue life of the standard forged and ausforged gears was approximately five times that of the VAR AISI 9310 gears and ten times that of the bending fatigue life of the standard machined VIM-VAR AISI M-50 gears run under identical conditions. There was a slight decrease in the 10-percent life of the ausforged gears from that for the standard forged gears, but the difference is not statistically significant. The standard machined gears failed primarily by gear tooth fracture while the forged and ausforged VIM-VAR AISI M-50 and the VAR AISI 9310 gears failed primarily by surface pitting fatigue. The ausforged gears had a slightly greater tendency to fail by tooth fracture than the standard forged gears.

Townsend, D. P.↗

A life study of ausforged, standard forged, and standard machined AISI M-50 spur gears

Tests were conducted at 350 K with three groups of 8.9 cm pitch diameter spur gears made of vacuum-induction melted (VIM), vacuum-arc remelted (VAR), AISI M-50 steel and one group of vacuum-arc remelted (VAR) AISI 9310 steel. The pitting fatigue life of the standard forged and ausforged gears was approximately five times that of the VAR AISI 9310 gears and ten times that of the bending fatigue life of the standard machined VIM-VAR AISI M-50 gears run under identical conditions. There was a slight decrease in the 10-percent life of the ausforged gears from that for the standard forged gears. However, the difference is not statistically significant. The standard machined gears failed primarily by gear tooth fracture while the forged and ausforged VIM-VAR AISI M-50 and the VAR AISI 9310 gears failed primarily by surface pitting fatigue. The ausforged gears had a slightly greater tendency to fail by tooth fracture than the standard forged gears.

Townsend, D. P.↗

Standard and Non-Standard Neutrino Oscillations at the NOvA Experiment

Initially believed to be massless, the discovery of neutrino oscillations proved that neutrinos have masses, a feature not anticipated by the Standard Model of Elementary Particles. Investigations of the existence of the so-called physics Beyond the Standard Model is a subject of active effort in the field of particle physics. Interactions of neutrinos with matter are well described by the Standard Model, however in the presence of new physics our knowledge and ability to measure the standard neutrino oscillation parameters may be affected. Non-Standard Interactions (NSI) may arise as a subleading effect to the neutrino oscillation framework by introducing additional parameters resulting from a generalized matter potential.

79 ASTRONOMY AND ASTROPHYSICS↗

A practical approach to using the Genomic Standards Consortium MIxS reporting standard for comparative genomics and metagenomics

Comparative analysis of (meta)genomes necessitates aggregation, integration, and synthesis of well-annotated data using standards. The Genomic Standards Consortium (GSC) collaborates with the research community to develop and maintain the Minimal Information about any (x) Sequence (MIxS) reporting standard for genomic data. To facilitate use of the GSC’s MIxS reporting standard, we provide a description of the structure and terminology, how to navigate ontologies for required terms in MIxS, and demonstrate practical usage through a soil metagenome example.

standards, metadata, genome, metagenome, schema, v↗

ESDIS Standards Office (ESO): Requirements, Standards and Practices

The ESDIS Standards Office assists the ESDIS Project in formulating standards policy for NASA Earth Science Data Systems (ESDS), coordinates standards activities within ESDIS, and provides technical expertise and assistance with standards related tasks within the NASA Earth Science Data System Working Groups (ESDSWG). This poster summarizes information found on the earthdata.nasa.gov site that describes the ESO.

Interoperability↗

EcoFAB: Advancing microbiome science through standardized fabricated ecosystems

The vital role microbiomes play in ecosystems and for human health is now apparent. Great progress has been made by using model systems to gain insight into host-microbe interactions, yet lack of standardized reproducible experimental systems and methods greatly limits microbiome science. Recent successes highlight the importance of developing these types of systems to deconstruct mechanisms mediating host-microbe interactions. Standardization of ‘fabricated ecosystems’ would enable detailed mechanistic interrogation and more effective knowledge transfer between researchers – analogous to the significant impact model organisms and cell systems have had in molecular and cell biology. To advance these efforts we advocate for strategies and overarching themes to enable communities of scientists to work together to develop standardized laboratory microbial consortia for studying host-associated microbiomes.

Zengler, Karsten↗

Standardization and Recommendations for EVSE Cybersecurity Standards

Currently, there is an absence of cybersecurity certification programs specifically for EVSE. Many existing standards focus primarily on safety, such as battery safety, while others provide cybersecu rity guidelines for different types of equipment, which could be adapted for EVSE. Among these, ISA/IEC 62443 has been identified as highly aligned with EVSE security needs. This report is a follow on to the previous research published (“Assessment and Coordination of EVSE Cybersecurity Standards,”). This report aims to find appropriate strategies for closing the gaps found in the aforementioned report and continue to work towards a comprehensive cybersecurity certification program for EVSE. Future testing will leverage this standard to assess EVSE security gaps and strengths, providing valuable insights to support certification development and harmonization of cybersecurity standards.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Historical Evolution of NASA Standard Materials Testing with Hypergolic Propellants and Ammonia (NASA Standard 6001 Test 15)

The NASA Johnson Space Center White Sands Test Facility (WSTF) has performed testing of hazardous and reactive aerospace fluids, including hypergolic propellants, with materials since the 1960s with the Apollo program. Amongst other test activities, Test 15 is a NASA standard test for evaluating the reactivity of materials with selected aerospace fluids, in particular hydrazine, monomethylhydrazine, uns-dimethylhydrazine, Aerozine 50, dinitrogen tetroxide oxidizers, and ammonia. This manuscript provides an overview of the history of Test 15 over a timeline ranging from prior to its development and first implementation as a NASA standard test in 1974 to its current refinement. Precursor documents to NASA standard tests, as they are currently known, are reviewed. A related supplementary test, international standardization, and enhancements to Test 15 are also discussed. Because WSTF was instrumental in the development and implementation of Test 15, WSTF experience and practices are referred to in this manuscript.

Greene, Benjamin↗

Standardized uptake values in FDG PET/CT for prosthetic heart valve endocarditis: a call for standardization

Background: The significance of and threshold values for the standardized uptake value (SUV) in FDG PET/CT to diagnose prosthetic heart valve (PHV) endocarditis (PVE) are unclear at present. Methods: A literature search was performed in the PubMed and EMBASE medical databases, comprising the following terms: (FDG OR *fluorode* OR *fluoro-de*) AND (endocarditis OR prosthetic heart valve OR valve replacement). Studies reporting SUVs correlated to the diagnosis of PVE were selected for analysis. Results: 8 studies were included, with a total of 330 PHVs assessed. SUVs for PVE varied substantially across studies due to differences in acquisition, reconstruction, and measurement protocols, with median SUVmax values for rejected PVE ranging from 0.5 to 4.9 and for definite PVE ranging from 4.2 to 7.4. Conclusion: Reported SUV values for PVE are not interchangeable between sites, and further standardization of quantification is desirable. To this end, optimal protocols for patient preparation, image acquisition, and reconstruction and measurement methods need to be standardized across centers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fine particulate matters: The impact of air quality standards on cardiovascular mortality

Highlights: • PM{sub 2.5} decreased following implementation of annual PM{sub 2.5} standard. • Cardiovascular mortality decreased with a decrease in PM{sub 2.5}. • Attainment counties had greater health benefit compared to nonattainment counties. • Associations were not statistically different. • Health benefits were shown even in counties below the current standard. In 1997 the U.S. Environmental Protection Agency set the first annual National Ambient Air Quality Standard (NAAQS) for fine particulate matter (PM{sub 2.5}). Although the weight of scientific evidence has determined that a causal relationship exists between PM{sub 2.5} exposures and cardiovascular effects, few studies have concluded whether NAAQS-related reductions in PM{sub 2.5} led to improvements in public health.

54 ENVIRONMENTAL SCIENCES↗

Regulatory Protection and Control Standards Applicable to The Vietnam Grid Under High Inverter-Based Resource (IBR) Penetration: A Review of Standards Applicable for Vietnam Grid

This report provides a review of the current standards and practices followed by regulatory authorities for interconnection of inverter-based resources (IBR). With the increased penetration of IBRs into the transmission and distribution networks, the legacy protection methodologies are getting challenged. Due to the lack of regulations on IBR operations under a fault it is essential to have a thorough understanding of the present-day interconnection standards to ensure proper IBR operations. A focus is placed on the regulation and standards enforced by the North American Reliability Corporation (NERC), Federal Energy Regulatory Commission (FERC), Institute of Electrical and Electronics Engineer (IEEE), Underwriters Laboratories (UL) and other regulations proposed by the responsible commissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA/NBS (National Aeronautics and Space Administration/National Bureau of Standards) standard reference model for telerobot control system architecture (NASREM)

The document describes the NASA Standard Reference Model (NASREM) Architecture for the Space Station Telerobot Control System. It defines the functional requirements and high level specifications of the control system for the NASA space Station document for the functional specification, and a guideline for the development of the control system architecture, of the 10C Flight Telerobot Servicer. The NASREM telerobot control system architecture defines a set of standard modules and interfaces which facilitates software design, development, validation, and test, and make possible the integration of telerobotics software from a wide variety of sources. Standard interfaces also provide the software hooks necessary to incrementally upgrade future Flight Telerobot Systems as new capabilities develop in computer science, robotics, and autonomous system control.

Albus, James S.↗

Product specification documentation standard and Data Item Descriptions (DID). Volume of the information system life-cycle and documentation standards, volume 3

This is the third of five volumes on Information System Life-Cycle and Documentation Standards which present a well organized, easily used standard for providing technical information needed for developing information systems, components, and related processes. This volume states the Software Management and Assurance Program documentation standard for a product specification document and for data item descriptions. The framework can be applied to any NASA information system, software, hardware, operational procedures components, and related processes.

Callender, E. David↗

Exploring a Black Body Source as an Absolute Radiometric Calibration Standard and Comparison with a NIST Traced Lamp Standard

Radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is required for the scientific research and application objectives pursued with the spectroscopic measurements. Specifically calibration is required for: inter-comparison of AVIRIS data measured at different locations and at different times; analysis of AVIRIS data with data measured by other instruments; and analysis of AVIRIS data in conjunction with computer models. The primary effect of radiometric calibration is conversion of AVIRIS instrument response values (digitized numbers, or DN) to units of absolute radiance. For example, a figure shows the instrument response spectrum measured by AVIRIS over a portion of Rogers Dry Lake, California, and another figure shows the same spectrum calibrated to radiance. Only the calibrated spectrum may be quantitatively analyzed for science research and application objectives. Since the initial development of the AVIRIS instrument-radiometric calibration has been based upon a 1000-W irradiance lamp with a calibration traced to the National Institute of Standards and Technology (NIST). There are several advantages to this irradiance-lamp calibration approach. First, the considerable effort of NIST backs up the calibration. Second, by changing the distance to the lamp, the output can closely span the radiance levels measured by AVIRIS. Third, this type of standard is widely used. Fourth, these calibrated lamps are comparatively inexpensive. Conversely, there are several disadvantages to this approach as well. First, the lamp is not a primary standard. Second, the lamp output characteristics may change in an unknown manner through time. Third, it is difficult to assess, constrain, or improve the calibration uncertainty delivered with the lamp. In an attempt to explore the effect and potentially address some of these disadvantages a set of analyses and measurements comparing an irradiance lamp with a black-body source have been completed. This research is ongoing, and the current set of measurements, analyses, and results are presented in this paper.

Green, Robert O.↗