Application of Distributed Fiber Optic Strain Sensors to LMQXFA Cold Mass Welding
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In the context of experimental vibration data, strain gauges can obtain linear and nonlinear dynamic measurements. However, measuring strain can be disincentivizing and expensive due to the complexity of data acquisition systems, lack of portability, and high costs. This research introduces the use of a low-cost efficient wireless intelligent sensor for strain (LEWIS-S) that is based on a portable-sensor-design platform that streamlines strain sensing. Additionally, the softening behavior of a cantilever beam with geometric and inertial nonlinearities is characterized by the LEWIS-S based on high force level inputs. Two experiments were performed on a nonlinear cantilever beam with measurements obtained by the LEWIS-S sensor and an accelerometer. First, a sine sweep test was performed through the fundamental resonance of the system, then a ring-down test was performed from a large initial static deformation. Good agreement was revealed in quantities of interest such as frequency response functions, the continuous wavelet transforms, and softening behavior in the backbone curves.
Summary Fiber-optic cables cemented outside of the casing of an unconventional well measure crosswell strain changes during fracturing of neighboring wells with low-frequency distributed acoustic sensing (LF-DAS). As a hydraulic fracture intersects an observation well instrumented with fiber-optic cables, the fracture fluid injected at ambient temperatures can cool a section of the sensing fiber. Often, LF-DAS and distributed temperature sensing (DTS) cables are run in tandem, enabling the detection of such cooling events. The increasing use of LF-DAS for characterizing unconventional hydraulic fracture completions demands an investigation of the effects of temperature on the measured strain response by LF-DAS. Researchers have demonstrated that LF-DAS can be used to extract the temporal derivative of temperature for use as a differential-temperature-gradient sensor. However, differential-temperature-gradient sensing is predicated on the ability to filter strain components out of the optical signal. In this work, beginning with an equation for optical phase shift of LF-DAS signals, a model relating strain, temperature, and optical phase shift is explicitly developed. The formula provides insights into the relative strength of strain and temperature effects on the phase shift. The uncertainty in the strain-rate measurements due to thermal effects is estimated. The relationship can also be used to quantify uncertainties in differential-temperature-gradient sensors due to strain perturbations. Additionally, a workflow is presented to simulate the LF-DAS response accounting for both strain and temperature effects. Hydraulic fracture geometries are generated with a 3D fracture simulator for a multistage unconventional completion. The fracture width distributions are imported by a displacement discontinuity method (DDM) program to compute the strain rates along an observation well. An analytic model is used to approximate the temperature in the fracture. Using the derived formulae for optical phase shift, the model outputs are then used to compute the LF-DAS response at a fiber-optic cable, enabling the generation of waterfall plots including both strain and thermal effects. The model results suggest that before, during, and immediately following a fracture intersecting a well instrumented with fiber, the strain on the fiber drives the LF-DAS signal. However, at later times, as completion fluid cools the observation well, the temperature component of the LF-DAS signal can be equal to or exceed the strain component. The modeled results are compared to a published field case in an attempt to enhance the interpretation of LF-DAS waterfall plots. Finally, we propose a sensing configuration to identify the events when “wet fractures” (fractures with fluids) intersect the observation well.
The overall goal of this project was to demonstrate and develop the usage of high-temperature (HT) harsh-environment (HE) wireless surface acoustic wave resonator (SAWR) sensor technology to promote reliable maintenance through condition-based maintenance (CBM) for field applications in harsh service conditions associated with power plant environments. The project aimed to advance the HT HE wireless SAWR sensor technology from TRL 5 to TRL 7. In addition to HT HE wireless temperature sensing, efforts were dedicated during this project to investigate, develop and increase the TRL from 3 to 5 for the following technologies: (a) HT HE strain sensors to address additional CBM monitoring needs, such as boiler tube mechanical / thermal stresses, which can provide early indications for boiler tube cracking and failure; and (b) HT aluminum nitride (AlN) and scandium aluminum nitride (ScAlN) based piezoelectric thin film fabrication and implementation of SAW sensors, with the goal of releasing the need to use single crystal piezoelectric materials for SAWRs and thus broaden possible technology applications to non-planar and harder to modify surfaces. To achieve the goals mentioned above, UMaine and its partner, Environetix Technologies Corporation, established partnerships with the following power plants: Longview Power (Maidsville, WV), a coal-fired power plant; Penobscot Energy Recovery Corp (PERC, Orrington, ME), a waste-to-energy power plant; and the UMaine Steam Plant (Orono, ME), an oil / natural gas power plant. To realize wireless HT HE SAWR sensor systems in these harsh service conditions, the University of Maine research team worked with Environetix and these power plants to define, design, fabricate, test and validate a mature prototype wireless temperature SAWR sensor system for boiler tube applications within the HT HE of the reheater pass damper chamber to directly and wirelessly monitor the temperature at eighteen independent boiler tube locations. The system included three levels, or “tiers”, of wireless communication to enable remote monitoring: Tier 1, the wireless link in the reheater pass damper chamber directly accessing the sensors on the boilers; Tier 2, the wireless local area network link, transmitting processed sensor information within the power plant to the Tier 3, a commercial wireless signal carrier company for secure remote data monitoring outside of the power plant. Regarding the wireless sensor system installed at Longview Power, temperature information from the boilers was continuously transmitted from the Longview boilers at Maidsville, WV, to Environetix headquarters, Orono, ME, over a 34 month period, when the system was finally decommissioned. Strain sensors and piezoelectric ScAlN thin film sensors were successfully installed on the exhaust duct at the UMaine Steam Power plant. The advances in wireless strain sensors and thin film piezoelectric film fabrication and testing were performed mostly in UMaine laboratories and field tested at the UMaine Steam Plant, due to its close proximity to UMaine/Environetix, access to the plant facility, and due to difficulties in accessing the other power plants during the COVID shut-down period. The project accomplished the TRL level increase of the targeted CBM technologies through the successful fabrication, installation, test, and validation of dedicated and commercial wireless sensor systems, utilizing the three different power plants. The outcomes of this project, including the wireless sensor data capability, are expected to yield an advance for CBM in harsh power plant environments. The reduction of maintenance costs, improved safety during plant operation, and increased power plant efficiency will lead to increased revenues (i.e., fewer forced outages) due to better process monitoring enabled by the wireless HT HE SAWR temperature sensor technology.
A thermo-mechanical bolometer includes a substrate and a sensing component mounted on the substrate. The sensing element comprises (a) at least one thermal-actuation component mounted in parallel with the substrate and (b) a strain sensor mounted on the at least one layer of thermal-actuation component. The at least one thermal-actuation component alone or in combination (a) absorbs electromagnetic waves and converts energy from absorbed electromagnetic waves into a change in temperature and (b) converts the change in temperature into a deformation of the at least one layer. The strain sensor comprises a layer of fragments with a gap space between the fragments, wherein the strain sensor senses the deformation or mechanical movement and exhibits a change in electrical resistance in response to the sensed deformation or mechanical movement.
A magnetoelastic sensor is provided for analyzing strain induced by a force causing mechanical deformation of a region of a substrate. The sensor includes a substrate that has a non-deformable region and a mechanically deformable region, the mechanically deformable region coupled to the non-deformable region by a linking structure. The sensor also has a transformer having a magnetic flux guide. The flux guide includes a magnetoelastic section having a magnetoelastic subsection configured to be strainable by deformation of the mechanically deformable region. In transformer embodiments, one or more drive coil and/or pickup coil has a width greater than the minimal width of the linking structure. Sensor embodiments include numerous configurations. The sensor is useful in methods for analyzing strain and force.
Accurate knowledge of the mechanical loads of wind turbine gearboxes has become essential in modern, highly loaded gearbox designs, as maintaining or even improving gearbox reliability with increasing torque density demands is proving to be challenging. Unfortunately, the traditional method of measuring dynamic mechanical torque using strain gauges placed on the outer surface of a rotating shaft and transmitting the resulting signal is unsuitable for serial deployment due to technical and economic constraints. An alternative method based on fiber-optic strain sensors placed on the stationary outer surface of the gearbox ring gear has been proposed. Like shaft torsion, the radial deformation of the ring gear is proportionate to the rotor torque. Placing the sensors on a stationary component is a cost-effective alternative for serial implementation because the need for complex and expensive data transfer via wireless transmission or a slip ring is eliminated. In this paper, we present the results of an extensive field experiment conducted to evaluate the torque measurement accuracy of this novel sensing solution installed on the gearbox of a Gamesa G97 2-MW wind turbine at the National Renewable Energy Laboratory's Flatirons Campus. Torque measurements derived from fiber-optic strain sensors placed on the ring gear of the planetary stage are compared to conventional torque measurements from strain gauges placed on the main shaft. Two different torque estimation data processing methods were evaluated, with the method based on operational deflection shapes providing the most accurate results with an average normalized root mean square error below 0.7% for a load revolution distribution analysis. The effect of operating conditions on the torque estimate was also investigated, and the third planet-passing operational deflection shape was found to be the least sensitive to nontorque load-related effects. The fiber-optic strain sensors' successful operation during the complete test campaign has demonstrated a robust and accurate solution for fleet-wide enhanced gearbox remaining useful life estimation.
Summary Low-frequency distributed acoustic sensing (LF-DAS) responds to strain changes due to far-field fracture propagation. To better understand the LF-DAS response to fracture propagation, we performed laboratory-scale hydraulic fracture experiments with embedded optical strain sensors. The objectives of this research are to generate hydraulic fractures of known geometry, measure the strain response along the embedded fiber-optic cable comparable to LF-DAS measurements, and use the results to inform the interpretation of field-derived LF-DAS data. The experiments were conducted in unconfined transparent cubic blocks with a dimension of 8 in. on each side. The block was made of transparent epoxy to visualize the fracture propagation. Fiber-optic sensing cables were embedded in the block at different distances to the source of injection. We injected dyed water through an injection tubing to generate a transverse, radial fracture along an initial flaw. An optical interrogator recorded the response of offset fiber Bragg grating (FBG) strain sensors normal to the plane of the fracture. The strain data were visualized on a waterfall plot, akin to visualizations of field-derived LF-DAS data. Dimensional analysis was used to scale the laboratory results to field conditions. We compared the evolution of the strain response at the fiber-optic cable, injection pressure, and rate with known fracture geometry. The measured strains were compared with Sneddon’s (1946) linear elastic solution for a penny-shaped crack and found to follow this behavior. The generated radial fractures in transparent media can be modeled with Sneddon’s linear elastic radial fracture model and a Mode I critical stress intensity factor. The LF-DAS characteristic response of a narrowing region of extension surrounded by compression was exhibited as a fracture that approached and intersected the fiber-optic cable. The experimentally derived strain and strain-rate waterfall plots with known fracture geometry, injection rate, and pressure response provide insight in understanding LF-DAS responses in the field. Furthermore, we developed a method to estimate fracture geometry evolution from the fiber-optic strain data and validated the method against the experimental data.
Optomechanical strain sensing provides attractive opportunities for novel particle detection schemes, as well as studying stress-induced (i.e. non-radiogenic) phonon bursts, which have been demonstrated to limit the coherence times of superconducting qubits [1,2] and are a suspected culprit in the low energy excesses observed by many dark matter direct detection experiments [3,4]. We are investigating SiN microring optical resonator strain sensors, developed at Purdue University [5], for applications in fundamental particle sensing and QIS. These sensors can be embedded in the substrate upon which superconducting qubits are patterned, providing a handle to distinguish decoherence events of radiogenic origin from those due to crystal stress. In a similar way, these sensors can be operated in conjunction with superconducting detectors (e.g., MKIDs, TES) to enable multi-channel readout of particle interactions in the device substrate or serve as anticoincidence detectors, which may be r equired to identify low-energy interactions from dark matter particles down to the fermionic thermal relic mass limit of a few keV. Such sensors can also be used to directly observe resonant scattering processes of gamma rays (and perhaps neutrinos) where no detectable quanta are produced in the target, via the microscopic strain induced by the momentum transfer to the (fixed-in-place) crystal lattice as a whole. These strain sensors have so far found application in photonics and communications, but have yet to be adopted for HEP uses, where they can provide unique capabilities in the search for dark matter, observing neutrino interactions, and improving the coherence times of superconducting qubits.
Optomechanical strain sensing provides attractive opportunities for novel particle detection schemes, as well as studying stress-induced (i.e. non-radiogenic) phonon bursts, which have been demonstrated to limit the coherence times of superconducting qubits and are a suspected culprit in the low energy excesses observed by many dark matter direct detection experiments. We are investigating SiN microring optical resonator strain sensors, developed at Purdue University, for applications in fundamental particle sensing and QIS. These sensors can be embedded in the substrate upon which superconducting qubits are patterned, providing a handle to distinguish decoherence events of radiogenic origin from those due to crystal stress. In a similar way, these sensors can be operated in conjunction with superconducting detectors (e.g., MKIDs, TES) to enable multi-channel readout of particle interactions in the device substrate or serve as anticoincidence detectors, which may be required to ident ify low-energy interactions from dark matter particles down to the fermionic thermal relic mass limit of a few keV. Such sensors can potentially be used to directly observe resonant scattering processes of gamma rays (and perhaps neutrinos) where no detectable quanta are produced in the target, via the microscopic stress induced by the momentum transfer to the (fixed-in-place) crystal lattice as a whole. These strain sensors have so far found application in photonics and communications, but have yet to be adopted for HEP uses, where they can provide unique capabilities in the search for dark matter as well as understanding and improving the coherence times of superconducting qubits.
Changes in barometric pressure propagate into the subsurface where they can affect water level measurements in wells and cause vertical strain. Previous strain sensors were developed to measure vertical strain, but they were limited to measurements at a single depth, making it difficult to evaluate strains from a migrating pressure wave. Technology known as Coherence-length-gated Microwave Photonics Interferometry (CMPI) uses optical fiber sensors to measure strain at multiple locations. It has the potential to detect strain caused by variations in barometric pressure at multiple depths in the subsurface. The goal of this study is to evaluate the feasibility of using this technology to record the changes in vertical strain in the vadose zone from small fluctuations in air pressure. Propagation of these air pressure fluctuations is affected by hydrogeological properties such as water content and permeability. A second goal of this study is to evaluate how these properties affect the air pressure distribution, strain, and gas-phase diffusivity with a long-term goal of using strain to monitor the vadose zone. The focus of this study is on a suite of laboratory experiments that used a sand-filled column with an open head space. The CMPI fiber was packaged and embedded along the axis of the column to measure the strain at multiple locations while air pressure transducers were installed through the wall of the column. Small periodic fluctuations in air pressure, similar to barometric pressure fluctuations, were created in the head space of the column using an audio driven speaker driven at 4 Hz using a sinusoidal signal created by a function generator. Then, the fluctuations propagated along the column where they were measured by the transducers and recorded as functions of time. Initial tests were conducted using dry sand, but then additional tests were conducted after injecting water into the column, which changed the hydrologic and mechanical properties. Another experiment was conducted after creating a thin barrier to air flow, which was designed to simulate a thin layer of saturated ground during rainfall. A final experiment was conducted by changing the grain size of the material to create a heterogeneity in the upper half of the column. The suite of six experiments was conducted to highlight effects of variations in water content and heterogeneities on air pressure and vertical strain. Numerical simulations were also created to evaluate the laboratory data and to provide a baseline analysis for the results. The numerical simulations used the governing equations to linear poroelasticity and two-phase flow with boundary conditions representing the experiments. The conceptual model for strain caused by barometric pressure recognizes that a fluctuating barometric pressure causes fluctuations in the air pore pressure that decrease in amplitude and lag in time with increase depth. The pressure distribution results in two different loads that cause strain: 1.) a mechanical load as the barometric pressure acts on the ground surface; and 2.) pressure loading in the pore space. The results show that the total vertical strain is a contribution of both of these loads, and this is the strain that was observed in the laboratory. The lab experiments show that both air pressure and strain vary as sinusoids that propagate with depth. The amplitude of the air pressure and strain decrease as a function of depth in all the conditions that were evaluate. For example, in the dry sand, the amplitude of the air pressure decreases from 25 Pa at the head space to 5 Pa at a depth of 70 cm, whereas the amplitude of the strain decreases from 0.15 to 0.06 µε over the same depth interval. In many cases the amplitudes decrease is approximately negative exponential functions of depth. When water was injected into the sand and the saturation increased, the amplitude of the air pressure increased in the partially saturated sand but decreased sharply to zero where the soil was saturated. The strain decreased with depth, but the transition from partially to fully saturated conditions had little effect on the strain profile, even though it had a major effect on the air pressure. This apparently is because strain is caused by variations in both water and air pressure. The fluctuating air pressure caused the water pressure to fluctuate, which caused strain throughout the column. Phase delay of the air pressure and the strain both increase as linear to bi-linear functions of depth. The phase delays indicate that pressure propagates at a velocity of 7 to 8 m/s in dry or partially saturated sand, but it drops by more than an order of magnitude in the vicinity of the capillary fringe. The phase delays indicate the strain propagates faster than the pressure. The data indicate that the strain propagates from 1.2 to more than 4x faster than the pressure. Switching from sand to silt in the column caused the velocity of the pressure to drop by roughly half for both pressures, but curiously, it had little effect on the velocity of the strain.
Not provided.
Abstract Wearable sensors that measure parameters associated with physical activity and bodily motions have been regarded as an indispensable tool for assessing personal wellness. Recent advances in nanocomposite strain sensors have been successfully used for monitoring skin strains and other strain‐derived physiological parameters. This study complements the existing body of work and presents a flexible, self‐adhering, fabric‐based wearable sensor for measuring skin strains and human motions. Graphene nanosheet thin films are directly spray‐coated onto kinesiology tape (K‐Tape) to obtain a self‐adhering strain sensor of high sensitivity and linearity. Their stable sensing performance and high repeatability are verified, while human subject tests confirm that they adequately capture muscle engagement during functional movements. In addition, densely distributed strain monitoring can be achieved using an electrical impedance tomography measurement approach and algorithm. Spatial strain sensing is successfully demonstrated using a single strip of piezoresistive K‐Tape, as well as when a K‐Tape network or mesh pattern is formed. The results show promise for using graphene K‐Tape meshes to measure how specific major muscle groups engage during different physical activities.
Dynamic strain sensing is relevant in numerous applications involving structural health monitoring, condition-based maintenance, operation efficiency preservation, and work environment safety. These sensors are particularly critical for high-temperature (HT) harsh-environment (HE) industries such as aerospace, automotive, power plants, and advanced manufacturing. In HT/HE, sensor implementation and measurement present challenges such as maintaining sensor stability, accounting for temperature cross-sensitivity, providing HT attachment, and packaging of the sensors and system. Surface acoustic wave resonator (SAWR) sensors can address these needs and offer additional benefits such as compact size and wireless interrogation capability. The SAWR sensitivity to dynamic strain is temperature dependent, making it necessary to measure the sensor temperature in order to use the correct dynamic strain calibration curve. In this work, a method for determining the temperature, dynamic strain magnitude, and dynamic strain spectral components using a single SAWR sensor is presented. Here, the established technique for determining operational temperature and dynamic strain magnitude/spectral components using only one SAWR simplifies the sensor measurement system, thus being very attractive for HT /HE applications.
Real-time monitoring of the liquid core position during the continuous casting of steel has been demonstrated using low-cost distributed optical-fiber-based strain sensors. These sensors were installed on the containment roll support structures in the segments of a production continuous caster to detect the position of the solid–liquid interface and monitor the strand condition during the continuous casting. Distributed Fiber Bragg Grating sensors (FBGs) were used in this work to monitor strain at six roll positions in the caster. The sensor performance was first validated by comparing optical strain measurements with conventional strain gauge measurements in the lab. Next, optical strain measurements were performed on an isolated caster segment in a segment maintenance facility using hydraulic jacks to simulate the presence of a liquid core under the roll. Finally, the sensors were evaluated during caster operation. The sensors successfully detected the load increase associated with the presence of a liquid core under each instrumented roll location. Incidents of bulging and roll eccentricity were also detected using frequency analysis of the optical strain signal. The liquid core position measurements were compared using predictions from computer models (digital twins) in use at the production site. The measurements were in good agreement with the model predictions, with a few exceptions. Under certain transient caster operating conditions, such as spraying practice changes and SEN exchanges, the model predictions deviated slightly from the liquid core position determined from strain measurements.
A stretchable pressure sensor is a necessary tool for perceiving physical interactions that take place on soft/deformable skins present in human bodies, prosthetic limbs, or soft robots. However, all existing types of stretchable pressure sensors have an inherent limitation, which is the interference of stretching with pressure sensing accuracy. Here, we present a design for a highly stretchable and highly sensitive pressure sensor that can provide unaltered sensing performance under stretching, which is realized through the synergistic creations of an ionic capacitive sensing mechanism and a mechanically hierarchical microstructure. Via this optimized structure, our sensor exhibits 98% strain insensitivity up to 50% strain and a low pressure detection limit of 0.2 Pa. With the capability to provide all the desired characteristics for quantitative pressure sensing on a deformable surface, this sensor has been used to realize the accurate sensation of physical interactions on human or soft robotic skin.