Search NASA⌕ Search

SEARCH · Search NASA

Results for “submillimeter wave imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Airborne imaging of tropospheric emission at millimeter and submillimeter wavelengths

In September 1993, the NASA Millimeter-wave Imaging Radiometer (MIR) flew on board the NASA ER-2 high-altitude aircraft during CAMEX, and obtained the first wideband millimeter- and submillimeter-wavelength images of tropospheric emission. The MIR is a cross-track radiometer with channels at 89, 150, 183 +/- 1, 3, 7, 220, and 325 +/- 1, 3, 8 GHz. This set provides upwelling brightness information at the two strong rotational water vapor lines at 183.310 and 325.153 GHz and three nearby atmospheric transmission windows. The wideband MIR images of convective raincells reveal unique cloud and precipitation mapping capabilities that are not available from lower frequency microwave channels. Comparisons between the 183 and 325 GHz spectra also reveal differential brightness temperature modes that are related to cloud water.

Wang, J. R.↗

Report of the heterodyne submillimeter-wave sensors panel

After reviewing the science goals of the Astrotech 21 mission set, and comparing the resulting receiver performance requirements with existing technology, the panel determined that there were significant unmet requirements in four areas: local oscillator power and mixer sensitivity in the Tera-Hz regime, infrared spectrometer channel count, and array technology in any form. A comprehensive development plan has been prepared to provide these capabilities in the time frame needed before technology freeze dates of the respective missions. It was also noted that development of these capabilities has immense payoff for future astrophysics missions, as it opens entire new areas of spectroscopy and imaging in the critical submillimeter wave regime rich in molecular transitions.

Wilson, Robert↗

ALMA Band-to-band Phase Referencing: Imaging Capabilities on Long Baselines and High Frequencies

High-frequency long-baseline experiments with the Atacama Large Millimeter/submillimeter Array were organized to test the high angular resolution imaging capabilities in the submillimeter wave regime using baselines up to 16 km. Four experiments were conducted, two Band 7 (289 GHz) and two Band 8 (405 GHz) observations. Phase correction using band-to-band (B2B) phase referencing was used with a phase calibrator only [[Formula]] away observed in Band 3 (96 GHz) and Band 4 (135 GHz), respectively. In Band 8, we achieved the highest resolution of 14 × 11 mas. We compared the synthesis images of the target quasar using 20 and 60 s switching cycle times in the phase referencing. In Band 7, the atmosphere had good stability in phase rms (<0.5 rad over 2 minutes), and there was little difference in image coherence between the 20 and 60 s switching cycle times. One Band 8 experiment was conducted under a worse phase rms condition (>1 rad over 2 minutes), which led to a significantly reduced coherence when using the 60 s switching cycle time. One of our four experiments indicates that the residual phase rms error after phase referencing can be reduced to 0.16 rad at 289 GHz in using the 20 s switching cycle time. Such conditions would meet the phase correction requirement of image coherence of >70% in Band 10, assuming a similar phase calibrator separation angle, emphasizing the need for such B2B phase referencing observing at high frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

New Challenges of Cloud Remote Sensing from Space

Clouds are recognized as a major source of uncertainties in predicting climate change. Lack of observational constraints on cloud processes has hindered the development of more reliable climate and weather models. With the advanced NASA EOS and A-Train sensors, we now have better knowledge about vertical distribution, water content, and occurrence frequency of global cloudiness. New ice water content (IWC) measurements from CloudSat and MLS have led to several improvements in model physics and parameterization schemes. MISR and GPS high-resolution data start to reveal deep insights on cloud processes and dynamicS in the planetary boundary layer (PBL). However, Earth sciences are still facing urgent needs to measure cloud microphysical properties, interactions between clouds and aerosol/precipitation, and processes that are coupled in 3-D space but not adequately sampled by the A-Train curtains or by the 2-D imageries. Submillimeter- wave, multi-angle imaging, and GPS radio occultation have emerged as promising remote sensing techniques to meet the challenges and enable new sciences for mid-tropospheric and PBL clouds.

Wu, Dong L.↗

Contemplating Synergistic Algorithms for the NASA ACE Mission

ACE is a proposed Tier 2 NASA Decadal Survey mission that will focus on clouds, aerosols, and precipitation as well as ocean ecosystems. The primary objective of the clouds component of this mission is to advance our ability to predict changes to the Earth's hydrological cycle and energy balance in response to climate forcings by generating observational constraints on future science questions, especially those associated with the effects of aerosol on clouds and precipitation. ACE will continue and extend the measurement heritage that began with the A-Train and that will continue through Earthcare. ACE planning efforts have identified several data streams that can contribute significantly to characterizing the properties of clouds and precipitation and the physical processes that force these properties. These include dual frequency Doppler radar, high spectral resolution lidar, polarimetric visible imagers, passive microwave and submillimeter wave radiometry. While all these data streams are technologically feasible, their total cost is substantial and likely prohibitive. It is, therefore, necessary to critically evaluate their contributions to the ACE science goals. We have begun developing algorithms to explore this trade space. Specifically, we will describe our early exploratory algorithms that take as input the set of potential ACE-like data streams and evaluate critically to what extent each data stream influences the error in a specific cloud quantity retrieval.

precipitation↗

'Long-wavelength astronomy' - A major future thrust

NASA plans for space-based studies of the portion of the electromagnetic spectrum spanning about 30 through 1000 microns are reviewed. The scientific goals of such investigations are examined, and the relevant missions are discussed, including the Space Infrared Telescope Facility (SIRTF), the Submillimeter Wave Astronomy Satellite (SWAS), the Submillimeter Imager and Line Survey (SMILS), the Large Deployable Reflector (LDR), and the lunar submillimeter interferometer. Performance comparisons for these long wavelength missions are presented.

Swanson, Paul N.↗

Imaging Antenna Structure For Submillimeter Wavelengths

Integrated-circuit antenna structure contains two-dimensional array of antennas and antenna reflectors. In receiving mode, each antenna acts as part of detector for one picture element in millimeter- or submillimeter-wavelength imaging radar system. Millimeter-wave imaging system used to view objects through fog, smoke, or smog with resolution intermediate between microwave and visible-light imaging systems. Antenna elements, supports, and reflectors made by integrated-circuit techniques. Structures fabricated on front and back substrates separately. Substrates then joined. Inexpensive way to provide large number of small antenna elements required for imaging, all mounted rigidly in way that does not degrade operation.

Rebeiz, G.↗

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record↗

Investigation of Passive Atmospheric Sounding Using Millimeter- and Submillimeter- Wavelength Channels

This report summarizes progress made during the period from July 1, 1994 through June 30, 1996 on the development of satellite-based observational techniques for high resolution imaging of precipitation and sounding of atmospheric ice and water vapor using passive microwave radiometers in the millimeter (MMW)- and submillimeter (SMMW)-wavelength. This is being achieved by radiative transfer modeling a millimeter and submillimeter wave frequencies and by the development and operation of an airborne millimeter wave imaging radiometer (MIR). The MIR has been used in both airborne and ground-based experiments. Its primary application is to provide calibrated radiometric imagery to verify MMW and SMMW radiative transfer models in clear air, cloud, and precipitation and to develop retrieval techniques using MMW and SMMW channels. The MIR imagery over convective storm cells has been used to illustrate the potentially useful cloud and water vapor sensing and storm-cell mapping capabilities of SMMW channels. The radiometric data has also been used to analyze radiative transfer model discrepancies caused by water vapor errors in radiosondes. The MMW and SMMW channels can be used to extend the altitude that water vapor sounding can be performed up into the lower stratosphere. Together, the use of both SMMW and MMW channels are expected to provide additional observational degrees of freedom related to cloud ice particle size.

Gasiewski, Albin J.↗

NASA Tech Briefs, June 2010

Topics covered include: Situational Awareness from a Low-Cost Camera System; Data Acquisition System for Multi-Frequency Radar Flight Operations Preparation; Mercury Toolset for Spatiotemporal Metadata; Social Tagging of Mission Data; Integrating Radar Image Data with Google Maps; Demonstration of a Submillimeter-Wave HEMT Oscillator Module at 330 GHz; Flexible Peripheral Component Interconnect Input/Output Card; Interface Supports Lightweight Subsystem Routing for Flight Applications; MMIC Amplifiers and Wafer Probes for 350 to 500 GHz; Public Risk Assessment Program; Particle Swarm Optimization Toolbox; Telescience Support Center Data System Software; Update on PISCES; Ground and Space Radar Volume Matching and Comparison Software; Web-Based Interface for Command and Control of Network Sensors; Orbit Determination Toolbox; Distributed Observer Network; Computer-Automated Evolution of Spacecraft X-Band Antennas; Practical Loop-Shaping Design of Feedback Control Systems; Fully Printed High-Frequency Phased-Array Antenna on Flexible Substrate; Formula for the Removal and Remediation of Polychlorinated Biphenyls in Painted Structures; Integrated Solar Concentrator and Shielded Radiator; Water Membrane Evaporator; Modeling of Failure for Analysis of Triaxial Braided Carbon Fiber Composites; Catalyst for Carbon Monoxide Oxidation; Titanium Hydroxide - a Volatile Species at High Temperature; Selective Functionalization of Carbon Nanotubes: Part II; Steerable Hopping Six-Legged Robot; Launchable and Retrievable Tetherobot; Hybrid Heat Exchangers; Orbital Winch for High-Strength, Space-Survivable Tethers; Parameterized Linear Longitudinal Airship Model; and Physics of Life: A Model for Non-Newtonian Properties of Living Systems.

Source record↗

Investigation of passive atmospheric sounding using millimeter and submillimeter wavelength channels

Progress by the Georgia Institute of Technology's Laboratory for Radio-science and Remote Sensing in developing techniques for passive microwave retrieval of water vapor profiles and cloud and precipitation parameters using millimeter and submillimeter wavelength channels is reviewed. Channels of particular interest are in the tropospheric transmission windows at 90, 166, 220, 340, and 410 GHz and centered around the water vapor lines at 183 and 325 GHz. Collectively, these channels have potential application in high-resolution precipitation mapping (e.g., from geosynchronous orbit), remote sensing of cloud and precipitation parameters, including cirrus ice mass, and improved retrieval of water vapor profiles. During the period from January 1, 1994 through June 30, 1994 research activities focussed on calibrating and interpreting data from the Millimeter-Wave Imaging Radiometer (MIR). The MIR was deployed on the NASA ER-2 during the Convective Atmospheric Moisture Experiment (CAMEX, September-October 1993) to obtain the first submillimeter-wave tropospheric imagery of convective precipitations. A 325-GHz radiometer consisted of a submillimeter-wave DSB receiver with three IF channels at +/- 1, 3, and 8.5 GHz, and approximately 14 dB DSB noise figure was successfully operated during these experiments. Activities supported under this grant include a study of the impact of local oscillator reflections from the MIR calibration loads, the development of optimal gain and offset filters for radiometric calibration, and the modeling and interpretation of the MIR 325-GHz data over both clear and cloudy atmospheres. In addition, polarimetric radiometer measurements and modeling for ocean surface and atmospheric cloud-ice studies_were supported.

Gasiewski, Albin J.↗

Investigation of passive atmospheric sounding using millimeter and submillimeter wavelength channels

Activities within the period from July 1, 1992 through December 31, 1992 by Georgia Tech researchers in millimeter and submillimeter wavelength tropospheric remote sensing have been centered around the calibration of the Millimeter-wave Imaging Radiometer (MIR), preliminary flight data analysis, and preparation for TOGA/COARE. The MIR instrument is a joint project between NASA/GSFC and Georgia Tech. In the current configuration, the MIR has channels at 90, 150, 183(+/-1,3,7), and 220 GHz. Provisions for three additional channels at 325(+/-1,3) and 8 GHz have been made, and a 325-GHz receiver is currently being built by the ZAX Millimeter Wave Corporation for use in the MIR. Past Georgia Tech contributions to the MIR and its related scientific uses have included basic system design studies, performance analyses, and circuit and radiometric load design, in-flight software, and post-flight data display software. The combination of the above millimeter wave and submillimeter wave channels aboard a single well-calibrated instrument will provide unique radiometric data for radiative transfer and cloud and water vapor retrieval studies. A paper by the PI discussing the potential benefits of passive millimeter and submillimeter wave observations for cloud, water vapor and precipitation measurements has recently been published, and is included as an appendix.

Gasiewski, Albin J.↗

International Symposium on Space Terahertz Technology, 1st, University of Michigan, Ann Arbor, Mar. 5, 6, 1990, Proceedings

Problems, proposed solutions, and recent results related to the development of solid-state oscillators, detectors, mixers, diode multipliers, and antennas at THz frequencies are addressed. Individual topics considered include: submillimeter heterodyne remote sensing of upper atmospheric gases, planar dipole array antenna with an elliptical lens, twin slot antenna structures integrated with microbolometer detectors for 94-GHz imaging. Also discussed are: quantum-well and quantum-barrier diodes for generating submillimeter wave power, planar Schottky barrier mixer diodes for space applications at submillimeter wavelengths, GaAs Schottky barrier varactor diodes for submillimeter wavelength power generation, planar doped barrier devices for subharmonic mixers.

Ulaby, Fawwaz↗

Dielectric Covered Planar Antennas at Submillimeter Wavelengths for Terahertz Imaging

Most optical systems require antennas with directive patterns. This means that the physical area of the antenna will be large in terms of the wavelength. When non-cooled systems are used, the losses of microstrip or coplanar waveguide lines impede the use of standard patch or slot antennas for a large number of elements in a phased array format. Traditionally, this problem has been solved by using silicon lenses. However, if an array of such highly directive antennas is to be used for imaging applications, the fabrication of many closely spaced lenses becomes a problem. Moreover, planar antennas are usually fed by microstrip or coplanar waveguides while the mixer or the detector elements (usually Schottky diodes) are coupled in a waveguide environment. The coupling between the antenna and the detector/ mixer can be a fabrication challenge in an imaging array at submillimeter wavelengths. Antennas excited by a waveguide (TE10) mode makes use of dielectric superlayers to increase the directivity. These antennas create a kind of Fabry- Perot cavity between the ground plane and the first layer of dielectric. In reality, the antenna operates as a leaky wave mode where a leaky wave pole propagates along the cavity while it radiates. Thanks to this pole, the directivity of a small antenna is considerably enhanced. The antenna consists of a waveguide feed, which can be coupled to a mixer or detector such as a Schottky diode via a standard probe design. The waveguide is loaded with a double-slot iris to perform an impedance match and to suppress undesired modes that can propagate on the cavity. On top of the slot there is an air cavity and on top, a small portion of a hemispherical lens. The fractional bandwidth of such antennas is around 10 percent, which is good enough for heterodyne imaging applications.The new geometry makes use of a silicon lens instead of dielectric quarter wavelength substrates. This design presents several advantages when used in the submillimeter-wave and terahertz bands: a) Antenna fabrication compatible with lithographic techniques. b) Much simpler fabrication of the lens. c) A simple quarter-wavelength matching layer of the lens will be more efficient if a smaller portion of the lens is used. d) The directivity is given by the lens diameter instead of the leaky pole (the bandwidth will not depend anymore on the directivity but just on the initial cavity). The feed is a standard waveguide, which is compatible with proven Schottky diode mixer/detector technologies. The development of such technology will benefit applications where submillimeter- wave heterodyne array designs are required. The main fields are national security, planetary exploration, and biomedicine. For national security, wideband submillimeter radars could be an effective tool for the standoff detection of hidden weapons or bombs concealed by clothing or packaging. In the field of planetary exploration, wideband submillimeter radars can be used as a spectrometer to detect trace concentrations of chemicals in atmospheres that are too cold to rely on thermal imaging techniques. In biomedicine, an imaging heterodyne system could be helpful in detecting skin diseases.

Chattopadhyay, Goutam↗

Planar Submillimeter-Wave Mixer Technology with Integrated Antenna

High-performance mixers at terahertz frequencies require good matching between the coupling circuits such as antennas and local oscillators and the diode embedding impedance. With the availability of amplifiers at submillimeter wavelengths and the need to have multi-pixel imagers and cameras, planar mixer architecture is required to have an integrated system. An integrated mixer with planar antenna provides a compact and optimized design at terahertz frequencies. Moreover, it leads to a planar architecture that enables efficient interconnect with submillimeter-wave amplifiers. In this architecture, a planar slot antenna is designed on a thin gallium arsenide (GaAs) membrane in such a way that the beam on either side of the membrane is symmetric and has good beam profile with high coupling efficiency. A coplanar waveguide (CPW) coupled Schottky diode mixer is designed and integrated with the antenna. In this architecture, the local oscillator (LO) is coupled through one side of the antenna and the RF from the other side, without requiring any beam sp litters or diplexers. The intermediate frequency (IF) comes out on a 50-ohm CPW line at the edge of the mixer chip, which can be wire-bonded to external circuits. This unique terahertz mixer has an integrated single planar antenna for coupling both the radio frequency (RF) input and LO injection without any diplexer or beamsplitters. The design utilizes novel planar slot antenna architecture on a 3- mthick GaAs membrane. This work is required to enable future multi-pixel terahertz receivers for astrophysics missions, and lightweight and compact receivers for planetary missions to the outer planets in our solar system. Also, this technology can be used in tera hertz radar imaging applications as well as for testing of quantum cascade lasers (QCLs).

Chattopadhyay, Gautam↗

A 311-GHz Fundamental Oscillator Using InP HBT Technology

This oscillator uses a single-emitter 0.3- m InP heterojunction bipolar transistor (HBT) device with maximum frequency of oscillation (fmax) greater than 500 GHz. Due to high conductor and substrate losses at submillimeterwave frequencies, a primary challenge is to efficiently use the intrinsic device gain. This was done by using a suitable transmission-line media and circuit topology. The passive components of the oscillator are realized in a twometal process with benzocyclobutene (BCB) used as the primary transmission line dielectric. The circuit was designed using microstrip transmission lines. The oscillator is implemented in a common-base topology due to its inherent instability, and the design includes an on-chip resonator, outputmatching circuitry, and an injection-locking port, the port being used to demonstrate the injection-locking prin ciple. A free-running frequency of 311.6 GHz has been measured by down-converting the signal. Ad di tionally, injection locking has been successfully demonstrated with up to 17.8 dB of injection-locking gain. The injection-locking reference signal is generated using a 2 20 GHz frequency synthesizer, followed by a doubler, active tripler, a W-band amplifier, and then a passive tripler. Therefore, the source frequency is multiplied 18 times to obtain a signal above 300 GHz that can be used to injection lock the oscillator. Measurement shows that injection locking has improved the phase noise of the oscillator and can be also used for synchronizing a series of oscillators. A signal conductor is implemented near the BCP -InP interface and the topside of the BCB layer is fully metallized as a signal ground. Because the fields are primarily constrained in the lower permittivity BCB region, this type of transmission line is referred to as an inverted microstrip. In addition, both common-emitter and commonbase circuits were investigated to determine optimum topology for oscillator design. The common -base topology required smaller amount of feedback than the common-emitter design, therefore preserving device gain, and was chosen for the oscillator design. The submillimeter-wave region offers several advantages for sensors and communication systems, such as high resolution and all-weather imaging due to the short-wavelength, and improved communication speeds by access to greater frequency bandwidth. This oscillator circuit is a prototype of the first HBT oscillator operating above 300 GHz. Additional development is necessary to increase the output power of the circuit for radar and imaging applications.

Gaier, Todd↗