Search NASA⌕ Search

SEARCH · Search NASA

Results for “talbot”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Simple, passive design for large optical trap arrays for single atoms

We present an approach for trapping cold atoms in a two-dimensional (2D) optical trap array generated with a 4f filtering scheme and custom transmission mask without any active device. The approach can be used to generate arrays of bright or dark traps, or both simultaneously with a single wavelength for forming two-species traps. We demonstrate the design by creating a 2D array of 1225 dark trap sites, where single Cs atoms are loaded into regions of near-zero intensity in an approximately Gaussian profile trap. Moreover, we demonstrate a simple solution to the problem of out-of-focus trapped atoms, which occurs due to the Talbot effect in periodic optical lattices. Using a high power yet low cost spectrally and spatially broadband laser, out-of-focus interference is mitigated, leading to near perfect removal of Talbot plane traps.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cone beam neutron interferometry: From modeling to applications

Phase-grating moiré interferometers (PGMIs) have emerged as promising candidates for the next generation of neutron interferometry, enabling the use of a polychromatic beam and manifesting interference patterns that can be directly imaged by existing neutron cameras. However, the modeling of the various PGMI configurations is limited to cumbersome numerical calculations and backward propagation models which often do not enable one to explore the setup parameters. Here we generalize the Fresnel scaling theorem to introduce a k -space model for PGMI setups illuminated by a cone beam, thus enabling an intuitive forward propagation model for a wide range of parameters and experimental setups. The interference manifested by a PGMI is shown to be a special case of the Talbot effect, and the optimal fringe visibility is shown to occur at the moiré location of the Talbot distances. We derive analytical expressions for the contrast and the propagating intensity profiles in various conditions and provide the first analysis of the PGMI dark-field imaging signal when considering sample characterization. The model's predictions are compared to experimental measurements and good agreement is found between them. Last, we propose and experimentally verify a method to recover contrast at typically inaccessible PGMI autocorrelation lengths. The presented work provides a toolbox for analyzing and understanding existing PGMI setups and their future applications, for example extensions to two-dimensional PGMIs and characterization of samples with nontrivial structures. Published by the American Physical Society 2024

Sarenac, D. (ORCID:0000000185753367)↗

$Z$-Pinch Interferometry Analysis With the Fourier-Based TNT Code

Here, we present the analysis of interferometry diagnostics with the user-friendly Talbot Numerical Tool (TNT), a Fourier-based postprocessing code that enables real-time assessment of plasma systems. TNT performance was explored with visible and infrared interferometry in pulsed-power-driven Z -pinch configurations to expand its capabilities beyond Talbot X-ray interferometry in the high-intensity laser environment. TNT enabled accurate electron density characterization of magnetically driven plasma flows and shocks through phase-retrieval methods that did not require data modification or masking. TNT demonstrated enhanced resolution, detecting below 4 % fringe shift, which corresponds to 8.7 × 10 15 cm –2 within 28 μ m, approaching the laser probing system limit. TNT was tested against a well-known interferometry analysis software, delivering an average resolving power nearly ten times better (~28 μ m versus ~ 210 μ m) when resolving plasma ablation features. TNT demonstrated higher sensitivity when probing sharp electron density gradients in supersonic shocks. A maximum electron areal density of 4.1 × 10 17 cm –2 was measured in the shocked plasma region, and a minimum electron density detection of ~ 1.0 × 10 15 cm –2 was achieved. When probing colliding plasma flows, the calculations of the effective adiabatic index and the associated errors were improved from γ* = 2.6 ± 1.6 – 1.4 ± 0.2 with TNT postprocessing, contributing valuable data for the interpretation of radiative transport. Additional applications of TNT in the characterization of pulsed-power plasmas and beyond are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive methods of generating complex light arrays

Structured light arrays of various shapes have been a cornerstone in optical science, driven by the complexities of precise and adaptable generation. This study introduces an approach using a spatial light modulator (SLM) as a generator for these arrays. By projecting a holographic mask onto the SLM, it functions simultaneously as an optical convolution device, focusing mechanism, and structured light beam mask. Our approach offers unmatched versatility, allowing for the experimental fabrication of traditional beam arrays like azimuthal Laguerre–Gaussian (LG), Bessel–Gaussian (BG), and Hermite–Gauss (HG) in the far-field. Notably, it has enabled a method of generating Ince–Gauss (IG) and LG radial mode beam arrays using a convolution solution. Our system provides exceptional control over array periodicity and intensity distribution, bypassing the Talbot self-imaging phenomenon seen in traditional setups. We provide an in-depth theoretical discussion, supported by empirical evidence, of our far-field results. This method has vast potential for applications in optical communication, data processing, and multi-particle manipulation. It paves the way for rapid generation of structured light with high spatial frequencies and complex shapes, promising transformative advances in these domains.

Optics↗

Evaporative Cooling in a Holographic Atom Trap

We present progress on evaporative cooling of Rb-87 atoms in our Holographic Atom Trap (HAT). The HAT is formed by the interference of five intersecting YAG laser beams: atoms are loaded from a vapor-cell MOT into the bright fringes of the interference pattern through the dipole force. The interference pattern is composed of Talbot fringes along the direction of propagation of the YAG beams, prior to evaporative cooling each Talbot fringe contains 300,000 atoms at 50 micro-K and peak densities of 2 x 10(exp 14)/cu cm. Evaporative cooling is achieved through adiabatically decreasing the intensity of the YAG laser. We present data and calculations covering a range of HAT geometries and cooling procedures.

Newell, Raymond↗

High-resolution multicontrast tomography with an X-ray microarray anode–structured target source

Multicontrast X-ray imaging with high resolution and sensitivity using Talbot–Lau interferometry (TLI) offers unique imaging capabilities that are important to a wide range of applications, including the study of morphological features with different physical properties in biological specimens. The conventional X-ray TLI approach relies on an absorption grating to create an array of micrometer-sized X-ray sources, posing numerous limitations, including technical challenges associated with grating fabrication for high-energy operations. We overcome these limitations by developing a TLI system with a microarray anode–structured target (MAAST) source. The MAAST features an array of precisely controlled microstructured metal inserts embedded in a diamond substrate. Using this TLI system, tomography of a Drum fish tooth with high resolution and tri-contrast (absorption, phase, and scattering) reveals useful complementary structural information that is inaccessible otherwise. The results highlight the exceptional capability of high-resolution multicontrast X-ray tomography empowered by the MAAST-based TLI method in biomedical applications.

47 OTHER INSTRUMENTATION↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intact, Commercial Lithium-Polymer Batteries: Spatially Resolved Grating-Based Interferometry Imaging, Bragg Edge Imaging, and Neutron Diffraction

We survey several neutron imaging and diffraction methods for non-destructive testing and evaluation of intact, commercial lithium-ion batteries. Specifically, far-field interferometry was explored as an option to probe a wide range of autocorrelation lengths within the batteries via neutron imaging. The dark-field interferometry images change remarkably from fresh to worn batteries, and from charged to discharged batteries. When attempting to search for visual evidence of battery degradation, neutron Talbot-Lau grating interferometry exposed battery layering and particle scattering through dark-field imaging. Bragg edge imaging also reveals battery wear and state of charge. Neutron diffraction observed chemical changes between fresh and worn, charged and discharged batteries. However, the utility of these methods, for commercial batteries, is dependent upon battery size and shape, with 19 to 43 mAh prismatic batteries proving most convenient for these experimental methods. This study reports some of the first spatially resolved, small angle scattering (dark-field) images showing battery degradation.

36 MATERIALS SCIENCE↗

Atmospheric Aerosol Chemical Composition Measurements for the Subsonic Aircraft: Contrail and Cloud Effects Special Study (SUCCESS)

We received funding to provide measurements of the chemical composition of aerosols aboard the NASA Ames DC-8 research aircraft during the SUCCESS mission. These measurements were successfully completed and the final data resides in the Cloud I computer archive at NASA Ames Research Center. The interpretation of the data obtained on this mission over the central United States has been published in special issues of Geophysical Research Letters. The papers with the University of New Hampshire as first author constitute this report and summarize the salient features of our data. The paper by Talbot et al. discusses the impact of vertical transport on free tropospheric chemistry over the the central USA in springtime. This transport was a dominant feature of the aerosol chemistry during SUCCESS. The paper by Dibb et al. discusses aerosol chemistry specifically as it related to free tropospheric sulfate related to jet exhaust and surface sources. Somewhat surprisingly, we found that surface sources appeared to dominant the distribution of aerosol sulfate in the free troposphere. In addition to these first authored papers, researchers from the University of New Hampshire were co-authors on numerous other companion papers in the special issues.

Talbot, Robert W.↗

Neutron Grating Interferometry at the High Flux Isotope Reactor

Neutron imaging is a non-destructive probe that can spatially resolve bulk materials’ internal features/structures. Neutron imaging spatial resolution is driven by detector technology, i.e., pixel size, and is currently on the order of 10–20 µm. This limitation can be alleviated by the use of neutron grating interferometry – an advanced neutron imaging technique – that enables simultaneous access to three contrast mechanisms: attenuation, differential phase, and small-angle neutron scattering. Recently, a Talbot-Lau neutron grating interferometry has been implemented at the Multimodal Advanced Radiography Station at the High Flux Isotope Reactor. In this work, the design, setup and performance of the grating apparatus are presented.

Zhang, Yuxuan [ORNL] (ORCID:0000000200831408)↗

Matter-wave interference of a native polypeptide

The de Broglie wave nature of matter is a paradigmatic example of quantum physics and it has been exploited in precision measurements of forces and fundamental constants. However, matter-wave interferometry has remained an outstanding challenge for natural polypeptides, building blocks of life, which are fragile and difficult to handle. Here, we demonstrate the wave nature of gramicidin, a natural antibiotic composed of 15 amino acids. Its center of mass is delocalized over more than 20 times the molecular size in our timedomain Talbot-Lau interferometer. We compare the observed interference fringes with a model that includes both a rigorous treatment of the peptide’s quantum wave nature as well as a quantum chemical assessment of its optical properties to distinguish our result from classical predictions. The realization of quantum optics with this prototypical biomolecule paves the way for quantum-assisted measurements on a large class of biologically relevant molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A large field-of-view high-resolution hard x-ray microscope using polymer optics

Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

47 OTHER INSTRUMENTATION↗

Shock propagation in aerogel and TPP foams for inertial fusion energy target design

Achieving practical inertial fusion energy (IFE) requires the development of target designs with well-characterized microstructure and compression response. We measured shock dynamics in low-density (17.5–500 mg/cm 3 ) aerogel and two-photon polymerization (TPP) foams using x-ray phase contrast imaging (XPCI) methods and the Velocity Interferometer System for Any Reflector. By analyzing shock front evolution, we examined how target type and density influence shock propagation and energy dissipation. Talbot-XPCI shows that aerogels support a smooth, bowed shock front due to their homogeneous nanometer-scale pore network. In contrast, TPP foams exhibit irregular, stepwise propagation driven by interactions with their periodic micrometer-scale lattice. Shock velocity follows a power-law relation: aerogels deviate from classical ρ −1/2 scaling due to pore-collapse dissipation, while TPP foams follow the trend with larger uncertainties from density variations. Comparisons with xRAGE simulations reveal systematic underestimation of shock speeds. These results provide the first experimental constraints on shock propagation in TPP foams over a wide density range and highlight the influence of internal structure on anisotropic shock behavior. Our findings support improved benchmarking of EOS and hydrodynamic models and inform the design of foam architectures that promote implosion symmetry in IFE capsules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Increased spatial coherence length from an asymmetric crystal reflection at grazing exit

Coherent X-ray imaging is an active field at synchrotron sources. The images rely on the available coherent flux over a limited field of view. At many synchrotron beamlines a double-crystal monochromator (DCM) is employed in a standard nondispersive arrangement. For coherent diffraction imaging it is advantageous to increase the available field of view by increasing the spatial coherence length (SCL) of a beam exiting such a DCM. Here, Talbot interferometry data together with ray-tracing simulations for a (+ − − +) four-reflection experimental arrangement are presented, wherein the first two reflections are in the DCM and the final fourth reflection is asymmetric at grazing exit. Analyses of the interferometry data combined with the simulations show that compared with the beam exiting the DCM a gain of 76% in the SCL was achieved, albeit with a factor of 20 reduction in flux density, which may not be a severe penalty at a synchrotron beamline. Previous efforts reported in the literature to increase the SCL that employed asymmetric crystal diffraction at grazing incidence are also discussed. A much reduced SCL is found presently in simulations wherein the same asymmetric crystal is set for grazing incidence instead of grazing exit. In addition, the present study is compared and contrasted with two other means of increasing the SCL. These are (i) focusing the beam onto an aperture to act as a secondary source, and (ii) allowing the beam to propagate in vacuum an additional distance along the beamline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of Data Acquisition Algorithms on X-ray Phase Contrast Imaging Computed Tomography

X-ray phase contrast imaging (XPCI) is a non-destructive evaluation technique that enables high-contrast detection of low-attenuation materials that are largely transparent in traditional radiography. Extending a grating based Talbot-Lau XPCI system to three- dimensional imaging with computed tomography (CT) imposes two motion requirements: the analyzer grating must translate transverse to the optical axis to capture image sets for XPCI reconstruction, and the sample must rotate to capture angular data for CT reconstruction. The acquisition algorithm choice determines the order of movement and positioning of the two stages. The choice of image acquisition algorithm for XPCI CT is instrumental to collecting high fidelity data for reconstruction. We investigate how data acquisition influences XPCI CT by comparing two simple data acquisition algorithms and determine that capturing a full phase-stepping image set for a CT projection before rotating the sample results in higher quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources

With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.

47 OTHER INSTRUMENTATION↗

X-Ray Phase Contrast Imaging for Dynamic Material Mix Experiments, LAO-003-17, Year 3 of 3

X-ray phase contrast imaging with transmission gratings for density profile measurements has been developed and tested for dynamic experimental applications. Talbot-Lau x-ray deflectometry is a new method of measuring x-ray refraction in addition to attenuation and ultrasmall-angle scattering that has recently been developed for static imaging, primarily for medical and industrial applications. To obtain density profiles from fast-evolving systems, we must use a flash x-ray source with a spot size much larger than the continuous microfocus sources of static imaging systems, and we can obtain only a single exposure. The challenges to measuring electron density profiles of two mixed elements from a single-image, low spatial resolution system are addressed, and initial results from the first dynamic experiments with one such system, conducted on a gas launcher at the end of FY 2018 and beginning of FY 2019, are presented. In FY 2019, we designed and built a new deflectometer designed for detonator experiments to test new techniques to improve the sensitivity and reliability of the diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MELCOR Deposition Models Applied to Noble Metals

Noble metals are chemically inert elements that form particles that can circulate around the fuel loop of a liquid-fueled molten salt reactor (LF-MSR). Due to their health-hazardous abilities, it is important to track these elements and to understand their contributions to source term during a reaction, particularly for Te as it decays into iodine. This report describes three solid deposition models that were implemented into the MELCOR reactor modeling code. The models that were implemented were Dittus-Boelter for turbulent fluid deposition, Talbot thermophoretic transport equation and Richardson-Zaki gravitational deposition. These closures were used to calculate the mass transfer coefficient and was compared to those reported for the Molten Salt Reactor Experiment (MSRE). The impacts of salt, operation and particle parameters on how they affect solid deposition are described, and found that solid deposition is strongly dependent on salt flow and viscosity, as well as particle diffusion rate and size. The conclusions form the basis for activities to be carried out in FY26 and for pursuit of future activities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗