Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Monitoring Temperatures of Tires Using Luminescent Materials

A method of noncontact, optical monitoring of the surface temperature of a tire has been devised to enable the use of local temperature rise as an indication of potential or impending failures. The method involves the use of temperature-sensitive paint (or filler): Temperature-sensitive luminescent dye molecules or other luminescent particles are incorporated into a thin, flexible material coating the tire surface of interest. (Alternatively, in principle, the luminescent material could be incorporated directly into the tire rubber, though this approach has not yet been tested.) The coated surface is illuminated with shorter-wavelength light to excite longer-wavelength luminescence, which is observed by use of a charge-coupled-device camera or a photodetector (see Figure 1). If temporally constant illumination is used, then the temperature can be deduced from the known temperature dependence of the intensity response of the luminescence. If pulsed illumination is used, then the temperature can be deduced from the known temperature dependence of the time or frequency response of the luminescence. If sinusoidally varying illumination is used, then the temperature can be deduced from the known temperature dependence of the phase response of the luminescence. Unlike a prior method of monitoring the temperature at a fixed spot on a tire by use of a thermocouple, this method is not restricted to one spot and can, therefore, yield information on the spatial distribution of temperature: in particular, it enables the discovery of newly forming hot spots where damage may be starting. Also unlike in the thermocouple method, the measurements in this method are not vulnerable to breakage of wires in repeated flexing of the tire. Moreover, unlike in another method in which infrared radiation is monitored as an indication of surface temperature, the luminescence measurements in this method are not significantly affected by changes in infrared emissivity. This method has been demonstrated in application to the outside surface of a tire (see Figure 2), using both constant and pulsed light sources for illumination and cooled, slow-scan, gated CCD cameras for detection. For observing the temperature of the inside surface of a tire (this has not yet been done), it would probably be necessary to use fiber optics and/or windows for coupling excitation light into, and coupling luminescence out of, the interior volume.

Bencic, Timothy J↗

Global temperature monitoring from space

Global and regional temperature variations in the lower troposphere and lower stratosphere are examined for the period 1979-92 from Microwave Sounder Unit (MSU) data obtained by the Television Infrared Observation Satellite (TIROS)-N series of National Oceanic and Atmospheric Administration (NOAA) operational satellites. In the lower troposphere, globally-averaged temperature variations appear to be dominated by tropical El Nino (warm) and La Nina (cool) events and volcanic eruptions. The Pinatubo volcanic eruption in June 1991 appears to have initiated a cooling trend which persisted through the most recent data analyzed (July, 1992), and largely overwhelmed the warming from the 1991-92 El Nino. The cooling has been stronger in the Northern Hemisphere than in the Southern Hemisphere. The temperature trend over the 13.5 year satellite record is small (+0.03 C) compared to the year-to-year variability (0.2-0.4 C), making detection of any global warming signal fruitless to date. However, the future global warming trend, currently predicted to be around 0.3 C/decade, will be much easier to discern should it develop. The lower stratospheric temperature record is dominated by warm episodes from the Pinatubo eruption and the March 1982 eruption of El Chichon volcano.

Spencer, R. W.↗

Chalcogenide Glass-Capped Fiber-Optic Sensor for Real-Time Temperature Monitoring in Extreme Environments

We demonstrate a novel chalcogenide glass (ChG)-capped optical fiber temperature sensor capable of operating within harsh environment. The sensor architecture utilizes the heat-induced phase change (amorphous-to-crystalline) property of ChGs, which rapidly (80–100 ns) changes the optical properties of the material. The sensor response to temperature variation around the phase change of the ChG cap at the tip of the fiber provides abrupt changes in the reflected power intensity. This temperature is indicative of the temperature at the sensing node. We present the sensing performance of six different compositions of ChGs and a method to interpret the temperature profile between 440 °C and 600 °C in real-time using an array structure. The unique radiation-hardness property of ChGs makes the devices compatible with high-temperature and high-radiation environments, such as monitoring the cladding temperature of Light Water (LWR) or Sodium-cooled Fast (SFR) reactors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global atmospheric temperature monitoring with satellite microwave measurements - Method and results 1979-84

This paper describes a method for determining global atmospheric-temperature anomalies by means of satellite microwave radiometry. It is shown that microwave measurements of molecular oxygen thermal emission by the Microwave Sounding Units (MSUs) flying aboard the NOAA-6 and NOAA-7 can be used to monitor tropospheric temperature anomalies on global basis to a high level of precision. Comparisons between monthly MSU-derived hemispheric temperature anomalies with those computed from surface thermometer data show a very good agreement over the United States, although not for the hemispheres, especially the Southern Hemisphere. In this latter case, the poor agreement is ascribed to weaker thermal coupling between the ocean and the deep troposphere than that over the U.S. Annual anomalies for the hemispheres exhibit better correlations than do monthly anomalies.

Spencer, Roy W.↗

Monitoring Temperature in High Enthalpy Arc-heated Plasma Flows using Tunable Diode Laser Absorption Spectroscopy

A tunable diode laser sensor was designed for in situ monitoring of temperature in the arc heater of the NASA Ames IHF arcjet facility (60 MW). An external cavity diode laser was used to generate light at 777.2 nm and laser absorption used to monitor the population of electronically excited oxygen atoms in an air plasma flow. Under the assumption of thermochemical equilibrium, time-resolved temperature measurements were obtained on four lines-of-sight, which enabled evaluation of the temperature uniformity in the plasma column for different arcjet operating conditions.

Martin, Marcel Nations↗

Sound Speed as a Candidate for Internal Temperature Monitoring During Solid Phase Processing of Materials

Internal temperature is an important parameter for understanding the solid phase processing (SPP) of materials and improving feedback control of these processes. Friction stir processes, shear assisted processing and extrusion (ShAPE ™ ), and ultrahigh velocity (UHV) cold spray are examples of such processes. Simple thermal models based on temperatures measured at the boundary of the deforming body cannot capture the dynamic nature of temperature generation within the deforming solid. One possibly way of understanding internal temperature is by measuring sound speed, which varies as a function of temperature for materials and directing ultrasonic wave propagation through selected material volumes of interest. In this project, longitudinal wave speed is estimated for aluminum 6061. Piezoelectric materials bonded to a specimen provided data from which longitudinal wave speed was estimated. A discussion evaluated the linear relationship of wave speed versus temperature and postulated how wave speed measurements could be used to estimate the internal temperature of selected material volumes for feedback during SPP of materials. Instrumentation, data and analysis, and a discussion are reviewed.

36 MATERIALS SCIENCE↗

Precision lower stratospheric temperature monitoring with the MSU - Technique, validation, and results 1979-1991

The stability of TIROS-N Microwave Sounding Unit (MSU) channel 4, which monitors the deep-layer averaged temperature of the lower stratosphere, is tested by intercalibrating MSU channel 4 data from the NIROS-N series of NOAA satellites during 1979-1991. The monthly gridpoint anomalies are validated with 10 years of radiosonde data during 1979-1988. The results demonstrated that the satellite sensors are very stable in their calibration and that the previously reported uncertainties in the stratospheric temperature information produced by NOAA are not the result of calibration changes in the MSUs. It was found that the largest globally averaged temperature variations during 1979-1991 occur after the El Chichon (1982) and Pinatubo (1991) volcanic eruptions. These warm events are superimposed upon a net downward trend in temperatures during the period. The cooling trend is strongest in polar regions and the Northern Hemisphere middle latitudes.

Spencer, Roy W.↗

Additive Manufacturing of Miniaturized Peak Temperature Monitors for In-Pile Applications

Passive monitoring techniques have been used for peak temperature measurements during irradiation tests by exploiting the melting point of well-characterized materials. Recent efforts to expand the capabilities of such peak temperature detection instrumentation include the development and testing of additively manufactured (AM) melt wires. In an effort to demonstrate and benchmark the performance and reliability of AM melt wires, we conducted a study to compare prototypical standard melt wires to an AM melt wire capsule, composed of printed aluminum, zinc, and tin melt wires. The lowest melting-point material used was Sn, with a melting point of approximately 230 °C, Zn melts at approximately 420 °C, and the high melting-point material was aluminum, with an approximate melting point of 660 °C. Through differential scanning calorimetry and furnace testing we show that the performance of our AM melt wire capsule was consistent with that of the standard melt-wire capsule, highlighting a path towards miniaturized peak-temperature sensors for in-pile sensor applications.

36 MATERIALS SCIENCE↗

Brillouin Sensing with PCA, and PCA-Based Neural Networks for Efficient Temperature Monitoring

This work explores peak estimation techniques in Brillouin Optical Time Domain Analysis (BOTDA), emphasizing both accuracy and efficiency. Euclidean distance measurement method is applied to principal components derived from Brillouin Gain Spectrum data. It offers a major speed advantage being 180 170 times faster than traditional curve fitting methods such as Lorentzian curve fitting, while maintaining similar accuracy. Additionally, a PCA- based neural network model shows significant reduction of peak estimation time compared to Lorentzian fitting. Results show Brillouin frequency shift errors lie under 0.75 MHz in both Euclidean distance-based and neural network-based methods, both of which utilize PCA components. For large data sets and long length fibers, PCA- assisted neural network for peak estimation would be an efficient solution.

Distributed optical fiber sensing↗

Aquarius Reflector Surface Temperature Monitoring Test and Analysis

The presentation addresses how to infer the front side temperatures for the Aquarius L-band reflector based upon backside measurement sites. Slides discussing the mission objectives and design details are at the same level found on typical project outreach websites and in conference papers respectively. The test discussion provides modest detail of an ordinary thermal balance test using mockup hardware. The photographs show an off-Lab vacuum chamber facility with no compromising details.

Comision Nacional para el Uso Eficiente de la Ener↗

Update on Earth Skin Temperature Monitoring From 16 Years of IASI Satellite Observations

Surface parameters such as emissivity and skin temperature have been retrieved from IASI measurements of last 16 years. Monthly and spatially gridded surface skin temperature is produced to show the phenomena of its natural variability, which is also reflected in the surface emissivity and/or soil moisture content derived from the same time series of measurements. The anomalies of surface skin temperature are used to estimate its trend. The IASI global surface skin temperature trend is comparable with the NASA GISTEMP5 global surface air temperature trend. The trend of IASI global surface skin temperature reports that an approximate 0.027 K/yr. increase has evolved during 2007–2023. Attention has been given to the arctic region where an average warming rate is near 3 times higher than the global average. In some arctic regions, the rapid warming rate has reached 0.2-0.3 K/yr. which is about 10 times higher than the global average. Geophysical distribution of the surface temperature trend in the arctic region is emphasized and reported.

Global warming↗

Supersonic combustion performance of hydrogen/hydrocarbon mixtures as determined by a nonintrusive temperature monitor

A simple and reliable OH absorption technique was developed and applied to measure path integrated temperature and OH number density in scramjet combustor hardware. The first series of measurements was made in premixed combustion products at the exit of a Mach 2 nozzle mounted on a hydrogen fueled vitiated heater. The second series of tests was conducted during supersonic combustion evaluation of hydrogen/hydrocarbon fuel mixtures. These measurements were made near the exit of a 48-inch long diverging supersonic combustor. The OH number density measurements indicated that both the nozzle and the combustor flow were not in equilibrium.

Northam, G. Burton↗

High Temperature Monitoring the Height of Condensed Water in Steam Pipes

An in-service health monitoring system is needed for steam pipes to track through their wall the condensation of water. The system is required to measure the height of the condensed water inside the pipe while operating at temperatures that are as high as 250 deg. C. The system needs to be able to make real time measurements while accounting for the effects of cavitation and wavy water surface. For this purpose, ultrasonic wave in pulse-echo configuration was used and reflected signals were acquired and auto-correlated to remove noise from the data and determine the water height. Transmitting and receiving the waves is done by piezoelectric transducers having Curie temperature that is significantly higher than 250 deg. C. Measurements were made at temperatures as high as 250 deg. C and have shown the feasibility of the test method. This manuscript reports the results of this feasibility study.

fluid height monitoring↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

Doped Lanthanum Chromite-refractory Based Composites Sensors for High Temperature Monitoring in Harsh Environments Systems

In order to test and monitor the operational stability and conditions of various energy, and manufacturing systems and their components, development of accurate sensors capable of operating at temperatures in excess of 1000 °C in various environments for long durations is required. In addition, many of these harsh-environment systems do not permit sensors to be directly inserted, so these sensors need to be embedded into thermal protective materials. In this work were developed high-temperature embedded thermocouples composed of various doped lanthanum chromites-refractory based composites synthesized by a mixed-oxide route and directly embedded into a Al2O3 based refractory. The electrical properties were specifically manipulated by altering the level of percolation of the conductive phase within the refractory constituent. Chemical stability of sensors was determined by phase development analysis by X-ray diffraction and X-ray photoelectron spectroscopy; Seebeck coefficients were determined by thermoelectric voltages measurements at temperature up to 1400 oC.

Perovskite LaCrO3, High-temperature conductivity, ↗

Satellite temperature monitoring and prediction system

The paper describes the Florida Satellite Freeze Forecast System (SFFS) in its current state. All data collection options have been demonstrated, and data collected over a three year period have been stored for future analysis. Presently, specific minimum temperature forecasts are issued routinely from November through March. The procedures for issuing these forecast are discussed. The automated data acquisition and processing system is described, and the physical and statistical models employed are examined.

Barnett, U. R.↗

Kankakee River Water Resources: Monitoring Temperature and Vegetation to Detect River Flow Impediments at Energy Intake Structures

The goal of this tutorial is to provide a comprehensive and accessible guide for detecting aquatic vegetation within the Kankakee River using Earth Observation data as well as pairing these observations with environmental trends monitoring. By offering step-by-step instructions and insights into the latest remote sensing technologies, this tutorial aims to equip readers with the knowledge and tools necessary to identify and track aquatic vegetation within a river extent of their choice.

Marisa Smedsrud↗

Precision Lower Stratospheric Temperature Monitoring with the MSU: Technique, Validation, and Results, 1979-1991

Microwave Sounding Unit channel 4 data from the TIROS-N (Television and Infrared Operational Satellite)-N series of NOAA (National Oceanic and Atmospheric Administration) satellites are intercalibrated to provide a continuous global record of deep-layer averaged lower stratospheric temperatures during 1979-1991. A 13-year record of temperature anomalies is time averaged into pentads and months on a 2.5 deg. grid. The monthly gridpoint anomalies are validated with ten years of radiosonde data during 1979-88. The calibration stability of each satellite's measurements is evaluated during satellite overlap periods, the longest of which reveal no measurable instrumental drift at the level of 0.01 C yr (exp -1). Intercomparisons between NOAA-6 and NOAA- 7 anomalies indicate monthly gridpoint precision of 0.05 C in the tropics to around 0.10 C in the extratropics, and signal-to-noise ratios precision and stability statistics are much better than have been previously reported by other investigators for MSU channel 4. Pentad precision is about 0.10 C in the tropics to around 0.25 C at high latitudes and signal-to- noise ratios generally over 250 in the tropics and high latitudes, but 100-200 in the middle latitudes. Radiosonde comparisons to the monthly gridpoint anomalies have correlations ranging from 0.90 in the tropics (where the interannual variability is smallest) to as high as 0.99 at high-latitude stations. The corresponding standard error of estimate is generally around 0.3 C. A significant difference in decadal trends is found between the satellite and radiosonde systems, with a step change of 0.21 C (sondes cooler) compared to the satellite measurements. Investigations of the possible sources of the discrepancy lead us to suspect that the gradual transition from on-site calibration of sondes with thermometers to factory calibration of sondes around 1982 might have caused a change in the calibration, although this conclusion must be viewed as tentative. The largest globally averaged temperature variations during 1979-91 occur after the El Chichon (1982) and Pinatubo (1991) volcanic eruptions. These warm events are superimposed upon a net downward trend in temperatures during the period. This cooling trend has more of a step function than linear character, with the step occurring during the El Chichon warm event. It is strongest in polar regions and the Northern Hemisphere middle latitudes. These characteristics are qualitatively consistent with radiative adjustments expected to occur with observed ozone depletions.

Spencer, Roy W.↗