Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Wireless Temperature-Monitoring System

A relatively inexpensive instrumentation system that includes units that are connected to thermocouples and that are parts of a radio-communication network has been developed to enable monitoring of temperatures at multiple locations. Because there is no need to string wires or cables for communication, the system is well suited for monitoring temperatures at remote locations and for applications in which frequent changes of monitored or monitoring locations are needed. The system can also be adapted to monitoring of slowly varying physical quantities, other than temperature, that can be transduced by solid-state electronic sensors. electronic sensors. The system comprises any number of transmitting units and a single receiving unit. Each transmitting unit includes connections for as many as four external thermocouples, a signal-conditioning module, a control module, and a radio-communication module. The signal-conditioning module acts as an interface between the thermocouples and the rest of the transmitting unit and includes a built-in solid ambient temperature sensor that is in addition to the external thermocouples. The control module is a system-on-chip embedded processor that includes analog-to-digital converters, serial and parallel data ports, and an interface for local connection to an analog meter that is used during installation to verify correct operation. The radio-communication module contains a commercial spread-spectrum transceiver that operates in the 900-MHz industrial, scientific, and medical (ISM) frequency band. This transceiver transmits data to the receiving unit at a rate of 19,200 baud. The receiving unit includes a transceiver like that of a transmitting unit, plus a control module that contains a system-on-chip processor that includes serial data port for output to a computer that runs monitoring and/or control software, a parallel data port for output to a printer, and a seven-segment light-emitting-diode display. Each transmitting unit is battery-powered and can operate for at least seven days continuously while reporting temperatures every half hour. The receiving unit is powered by a wall-mounted transformer source. The receiving unit responds to each transmitting unit and reports the readings of each of the four thermocouples and of the ambient-temperature sensor of the transmitting unit. The end-to-end accuracy of the system is plus or minus 0.2 C over the temperature range from 0 to 100 C. The radio-communication range between the receiving and transmitting units is approximately equal to 0.5 mile (approximately equal to 0.8 km).

Solano, Wanda↗

Wireless Temperature-Monitoring System

A relatively inexpensive instrumentation system that includes units that are connected to thermocouples and that are parts of a radio-communication network has been developed to enable monitoring of temperatures at multiple locations. Because there is no need to string wires or cables for communication, the system is well suited for monitoring temperatures at remote locations and for applications in which frequent changes of monitored or monitoring locations are needed. The system can also be adapted to monitoring of slowly varying physical quantities, other than temperature, that can be transduced by solid-state electronic sensors. The system comprises any number of transmitting units and a single receiving unit (see figure). Each transmitting unit includes connections for as many as four external thermocouples, a signal-conditioning module, a control module, and a radio-communication module. The signal- conditioning module acts as an interface between the thermocouples and the rest of the transmitting unit and includes a built-in solid ambient-temperature sensor that is in addition to the external thermocouples. The control module is a "system-on-chip" embedded processor that includes analog-to-digital converters, serial and parallel data ports, and an interface for local connection to an analog meter that is used during installation to verify correct operation. The radio-communication module contains a commercial spread-spectrum transceiver that operates in the 900-MHz industrial, scientific, and medical (ISM) frequency band. This transceiver transmits data to the receiving unit at a rate of 19,200 baud. The receiving unit includes a transceiver like that of a transmitting unit, plus a control module that contains a system-on-chip processor that includes serial data port for output to a computer that runs monitoring and/or control software, a parallel data port for output to a printer, and a seven-segment light-emitting-diode display.

Solano, Wanda↗

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing Temperature Monitoring of the Bottom Anode in a Direct Current Electric Arc Furnace Operations with Distributed Optical Fiber Sensors.

The bottom anode in the Direct Current Electric Arc Furnace (DC EAF) is critical for completing the electrical circuit necessary for sustaining the arc within the furnace. For pin-type bottom anodes, monitoring of the temperature of select pins instrumented with thermocouples is performed to track bottom wear in the EAF and inform the operator when the furnace should be removed from service. Furthermore, this work presents the results from a plant trial using distributed temperature monitoring of bottom anode pins in a 165-ton DC EAF over a two-month service period utilizing two optical fiber sensing techniques: fiber Bragg grating (FBG) and Rayleigh backscattering (RBS). The early detection of temperature anomalies along the length of the anode pin through distributed sensing enhances operational safety, providing a robust alternative to traditional thermocouples.

42 ENGINEERING↗

A New ERA in Global Temperature Monitoring with the Advanced Microwave Sounding Unit (AMSU)

The launch of the first Advanced Microwave Sounding Unit (AMSU) on the NOAA-15 spacecraft on 13 May 1998 marked a significant advance in our ability to monitor global temperatures. Compared to the Microwave Sounding Units (MSU) flying since 1978 on the TIROS-N series of NOAA polar orbiters, the AMSU offers better horizontal, vertical, and radiometric resolutions. It will allow routine monitoring of 1 1 (mostly) separate layers, compared to 2 or 3 with the MSU, including layers in the middle and upper stratosphere (2.5 hPa) where increasing carbon dioxide concentrations should be causing a cooling rate of about 1 deg. C per decade. More precise limb corrections combined with low noise will allow identification of subtle spatial temperature patterns associated with global cyclone activity.

Spencer, Roy W.↗

FET Junction Temperature Monitoring Using Novel On-Chip Solution

A novel junction temperature monitoring sensor is proposed and experimentally demonstrated for application in MOS-gate power devices. The sensor is created using the polycide gate electrode layer of the devices to create a temperature-sensitive resistor without any additional fabrication steps. The resistor is located on the field oxide with one end grounded at the device reference terminal to isolate it from the device current and voltage transients. It allows in-situ monitoring of the device junction temperature during active circuit operation. The technology has been implemented to monitor the junction temperature of Silicon Carbide Junction Barrier Schottky Field Effect Transistors (SiC JBSFETs) with the bi-directional FET (BiDFET).

Bidirectional switches, SiC bidirectional FET, BiD↗

Distributed Temperature Monitoring of Tundish Refractory Lining Using Optical Fiber Sensors

Distributed temperature monitoring can provide useful insights into the thermal conditions in the continuous caster tundish that can affect operating stability and cast quality, such as preheat conditions, superheat uniformity, fill height, and refractory wear. In the current study, fiber optic sensors were embedded into the refractory lining of a lab-scale tundish to record the temperature profiles during dry-out, preheating, and direct molten steel exposure to demonstrate sensor performance. Additional trials were performed with fiber optic sensors embedded in an industrial tundish used in production. Furthermore, the results demonstrate that fiber optic sensors using Rayleigh technology can provide accurate distributed temperature measurements in refractory lined vessels and provide useful information about the process.

Continuous Caster↗

Evaluations of Silicon Carbide Temperature Monitors

The effect of irradiation on materials properties is an important field of study for materials usage in both fission and fusion systems for energy production. Neutron flux and energy spectrums are well understood; however, the irradiation temperature can be more difficult to determine. Since the early 1960s, Silicon Carbide (SiC) has been used as a passive post-irradiation temperature monitor because the irradiation defects anneal out above the irradiation temperature. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process. There are many properties that may be measured including electrical resistivity, bulk density, dimensions, thermal diffusivity, or lattice spacing. Electrical resistivity is accepted as a robust measurement technique; however, such method is time-consuming since the steps involved must be performed in a serial manner. The use of thermal expansion from continuous dilatometry is an automated process requiring minimal setup time. As part of a Nuclear Science User Facilities (NSUF) project, low dose silicon carbide monitors were irradiated in the BR2 material test reactor at SCK, Belgium, and were then evaluated at the Idaho National Laboratory (INL) High Temperature Test Laboratory (HTTL) to determine their peak temperature achieved during irradiation. The technical significance of this work was that the monitors were irradiated to a dose that was significantly less than recommended in published literature. This paper will discuss the evaluation processes available at HTTL and the performance of the low dose silicon carbide temperature monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid temperature-monitoring circuit

Hybrid circuit developed for use in hand-held vital signs monitor converts resistance of thermistor probe to 3 1/2 digit BCD (binary-coded-decimal) temperature readout. If used alone circuit can form 'stand alone' temperature monitor or can transmit temperature data via telemetry to data acquisition systems.

Rinard, G. A.↗

Monitoring Temperatures Indirectly in Cooled Combustors

Noninvasive monitoring of temperatures on inner surface of combustion liner of cooled combustor increases liner life, thereby increasing combustor reliability and performance. Technique used in furnaces, reactors, jet engines, rocket engines, stationary turbines, combustors, and heat exchangers. Growth of internal overheating streaks monitored using output from array of thermocouples on outside wall of combustor. Computer analysis of output indicates temperature pattern on combustor lining. Use of data enables timely liner maintenance or overhaul.

Wagner, W.↗

Raspberry Pi–powered temperature monitoring of growth chamber microclimates

While controlled environments are desirable for growing and measuring plants, growth chambers and greenhouses typically have microclimates that impact plant growth, development, and stress responses. Furthermore, opening and closing the doors of a controlled environment introduces variation in the environment, especially at temperature extremes, affecting both the measurements and the organisms within. Using multiple temperature data loggers to normalize results can be cost-prohibitive and rarely offers real-time feedback on temperature status. We used low-cost single-board computers, cameras, and temperature sensors to manage and capture growth chamber temperatures while acquiring plant image data. Detailed here are methods to document microclimates within a growth chamber so that data can be normalized to measured temperature information. This protocol describes a low-cost method for automated temperature monitoring, which enables both high-throughput measurements of temperature along with plant growth and stress responses via plant imaging.

Plant Sciences↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Controller and temperature monitor for solar heating

Report describes development and certification of 77-171 differential thermostat for controlling solar-heating and cooling systems and 77-180 temperature monitor of indoor, outdoor, and storage temperatures. Units are commercially available.

Hankins, J. D.↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Global Surface Skin Temperature Monitoring from Satellites

Surface skin temperature has been retrieved from IASI measurements. Monthly and spatially gridded surface skin temperature is produced to show some phenomena of its natural variability, which is also reflected in the surface emissivity and/or soil moisture derived from the same time series of measurements. The anomalies of surface skin temperature are used to estimate its trend. Error estimation and/or evaluation has been performed and discussed to understand the uncertainty in the trends. The trend of IASI global surface skin temperature is compared with that of NASA GISS global surface air temperature. Despite the physical differences between surface skin and air temperatures, agreement is shown between these two datasets indicating consistency and global surface warming during the past 15 years. The trend of IASI global surface skin temperature reports a positive increase has evolved during 2007–2022. This warming trend is more pronounced in the northern hemisphere. Retrieving, analyzing, and monitoring surface parameters from such advanced hyperspectral infrared sounders will continue.

global warming↗

Evaluation of Low Dose Silicon Carbide Temperature Monitors

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at materials and test reactors. Melt wires or paint spots are often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires and paint spots as a post-irradiation technique for peak temperature indication. Unfortunately, these techniques are limited in that they can only detect whether a single temperature is or is not exceeded. Silicon carbide (SiC) monitors are advantageous because a single monitor can be used to determine the peak temperature reached within a relatively broad range (200 – 800°C). Although the use of SiC monitors was proposed more than five decades ago, the ultimate performance limits of this technique are not fully understood. The Nuclear Science User Facilities (NSUF) is the United States Department of Energy Office of Nuclear Energy's only designated nuclear energy user facility. Its mission is to provide nuclear energy researchers access to world-class capabilities and to facilitate the advancement of nuclear science and technology. This mission is supported by providing access to state-of-the-art experimental irradiation testing, post irradiation examination facilities, and high performance computing capabilities as well as technical and scientific assistance for the design and execution of projects. As part of an NSUF project, low dose silicon carbide monitors were irradiated in the Belgian Reactor 2 and were then evaluated both at the SCK•CEN and at Idaho National Laboratory's High Temperature Test Laboratory to determine their peak temperature achieved during irradiation. The technical significance of this work was that the monitors were irradiated to a dose that was significantly less than recommended in published literature. This paper will discuss the evaluation process, the irradiation test, and the performance of the low dose silicon carbide temperature monitors.

36 MATERIALS SCIENCE↗

Toward local core outlet temperature monitoring in gas-cooled nuclear reactors using distributed fiber-optic temperature sensors

Gas-cooled nuclear reactors operate at temperatures up to 950 °C with significant spatial variations in power generation and coolant flow through hundreds of parallel flow channels, resulting in complex mixing at the core outlet. The high temperatures and complex mixing can damage downstream components, challenge reactor calorimetry for power determination, and result in significant conservatism in calculated peak fuel temperatures, which ultimately limits the total power output. Directly measuring each gas stream individually is unrealistic using single point thermocouples, requiring more robust sensing techniques. Fiber-optic sensors are resilient to high temperatures (up to 1,000 °C) and radiation damage. Moreover, distributed measurements can be made along the length of one fiber, making them potential candidates for monitoring local core outlet temperatures to improve core calorimetry and identify hot channels. Here, to the authors’ knowledge, this manuscript is the first to report spatially distributed fiber optic temperature measurements to quantify mixing at the outlet of a relevant orifice plate under prototypic temperature and flow regimes to assess the feasibility of using fiber-optic sensors for distributed measurements of coolant temperature in gas-cooled reactors. A single optical fiber captured dynamic changes in local temperatures, whereas the mixed outlet temperature exhibited a muted response and could not identify which channels were responsible for the change in the mixed outlet temperature. The discussion focuses on potential challenges for deploying distributed optical fibers in gas-cooled reactors, including the effects of vibrations, radiation-induced signal attenuation and drift, and routing of the fiber while minimizing flow obstructions.

42 ENGINEERING↗