Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Exergy and thermo-economic analysis for MED-TVC desalination systems

An exergo-economic model is used to simulate four different feed configurations of multi-effect desalination with thermal vapor compressor (MED-TVC) system. The feed configurations considered are backward feed (BF), forward feed (FF), parallel feed (PF) and parallel cross feed (PCF). The model results indicate that the PCF configuration has better performance characteristics than the other feed configurations regarding gain output ratio (GOR) and specific heat consumption (SHC), but it has the highest specific cooling seawater flow rate ($sM_{cw}$). On the other hand, the BF configuration has the lowest $sM_{cw}$. The highest exergy destruction (58%) occurs within the TVC unit and this can be reduced by lowering the supplied motive steam pressure. The exergy destructions in the condenser and pumps account for 4 to 6.7% of the total exergy destruction for all feed configurations. The MED-TVC under consideration has a second law efficiency between 3.9 and 4.6%. Lowering the motive steam pressure for the PCF from 2300 to 300 kPa results in a 7.5% reduction in GOR and a 25.4% increase in the second law efficiency. Reducing the exergy destruction in the TVC unit is cost-effective for the entire system even with the increase in capital investment costs. The specific exergy cost flow method is used to estimate the total water price for BF, FF, PF and PCF as 2.12, 2.30, 2.16 and 2.09 $\$/m^3$, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient performance of MED processes with different feed configurations

Four different configurations of Multi-Effect-Desalination (MED): backward feed (BF), forward feed (FF), parallel feed (PF) and parallel/cross feed (PCF) are modeled in steady and dynamic operation to examine the behavior of these configurations under transient operation. Adding thermal vapor compressor (TVC) unit with the last effect of parallel/cross configuration is also studied and compared to the other configurations to show the advantage of this type of integration. The transient operation is achieved by applying ramp changes (disturbances) in the main input parameters that include steam flow rate at the heat source and cooling seawater temperature and flow rate at the heat sink. Steady state results indicate that parallel/cross feed has a relatively better performance characteristic than the other feed configurations regarding Gain Output Ratio (GOR) and specific heat consumption (SHC). Adding TVC unit to the parallel/cross feed achieves the lowest water production cost. Dynamic results show that MED-TVC with parallel/cross feed has the fastest response while backward feed and forward feed have the slower response to the applied disturbances. In the case of heat source disturbance, MED plants operating in the backward feed arrangement may be exposed to shut down due to the significant increase in brine level for the first effect. The MED-TVC process is susceptible to the heat sink disturbances compared to the PCF and other configurations. Also, changes in input parameters lead to the highest reduction in GOR for the MED-TVC process compared to the different configurations, especially for cooling seawater temperature. The highest reduction in brine level occurs in MED-TVC for a disturbance in the cooling seawater flow rate and may lead to MED-TVC evaporator drying condition. Hence, MED-TVC will require a reliable control system to avoid this type of plant operational disturbance.

42 ENGINEERING↗

Effect of disturbances on MED-TVC plant characteristics: Dynamic modeling and simulation

This study describes a detailed steady-state analysis and transient operation of a multi-effect desalination plant with a thermal vapor compressor unit (MED-TVC). The model developed is based on solving the basic conservation equations of mass, energy, and salt. It can predict steady-state operation and transient behavior when the plant is subject to abrupt changes in the main input parameters including motive steam flow rate (m ms ), cooling seawater flow rate (m cw ) and cooling seawater temperature (T cw ). These sudden changes simulate the conditions a MED-TVC plant may be exposed to. Both the steady-state and dynamic aspects of the model are validated against published experimental data. Monitoring the variation of four state variables (vapor temperature, brine level, brine and vapor flow rates) in each effect shows that disturbances in the motive steam flow rate and the cooling seawater temperature have a significant effect on the plant performance. On the other hand, the disturbance in the cooling seawater mass flow rate has only a moderate effect. For all applied disturbances, the change in the brine level is the slowest compared to the changes in vapor temperature, and brine and vapor flow rates. Furthermore, the effect of changing seawater salinity shows a slight effect on the total distillate production and the specific heat transfer area.

42 ENGINEERING↗

Utilization of waste heat from a commercial GT for freshwater production, cooling and additional power: Exergoeconomic analysis and optimization

In this work, a multigeneration system is proposed for power, cooling and freshwater production. The waste heat from a SIEMENS SGT6-2000E GT is utilized to drive a supercritical CO 2 recompression Brayton cycle (SCRBC) and multi-effect desalination (MED) with thermal vapor compressor (TVC), while the waste heat from the pre-cooler of the SCRBC is utilized to drive an absorption cooling cycle. Detailed thermodynamic, exergy and exergoeconomic analyses are performed for the proposed multigeneration system using Engineering Equation Solver (EES). A sensitivity study is also performed to study the effects of the main operational parameters on the proposed system performance. Finally, multi-objective optimization using a genetic algorithm approach in EES is carried out to reach the optimal design. The proposed system can consume 34.2% less energy input and reduce CO 2 emission by 39.3% compared to the stand-alone systems for power, cooling and freshwater production. The results show that the energy utilization factor and exergy efficiency of the proposed system are improved by 33.6% and 14.3%, respectively, while the total unit product cost is reduced by 11.3% compared to the stand-alone GT cycle. Further, from exergoeconomic optimization, the proposed system can produce 132.4 MW of power, 7.09 MW of cooling and 650 kg/s of freshwater at energy utilization factor of 57.5%, exergy efficiency of 39.7% and total unit product cost of 16.3 $/GJ.

42 ENGINEERING↗

A Non-condensing Thermal Compression Power Generation System

Organic Rankine cycle (ORC) systems have attracted interest for more than three decades due to advantages in operation at lower working temperature, low maintenance requirements, and relative simplicity (fewer components). In theory, these advantages should make ORC technology more economically attractive for the small and medium power scales (10 kW to 10 MW). Unfortunately, the theoretical promise of ORC systems for power generation has been realized at only a relatively small fraction of the potential market. Although there are a number of reasons for the low utilization of ORC technology, the root cause is directly tied to the relatively low heat-to-power conversion efficiency (2 to 7% typically) and high cost of specially designed expander–generator equipment that is up to 60% of total system cost. The resulting high cost of the power produced just does not make economic sense except in very specialized situations where on-site power is needed but unavailable (at any cost) or where local generation costs are well above regional averages. The overarching objective of the work presented here is to break this paradigm by developing and demonstrating a new harmonic adsorption recuperative power cycle (HARP) system that offers 40% more efficient power generation as compared with a standard ORC system and estimated electric power production costs at very competitive rates below $0.10/kWh.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Thermal Powered Technology for UUV Persistent Surveillance

Buoyancy Generation: Various technology attempts include melting a wax, which pushes directly against a piston (U.S. Patent 5,291,847) or against a bladder (Webb Research), using ammonia or Freon 21 (U.S. Patent 5,303,552), and using solar heat to expand an oil (www.space.com, April, 10, 2002). All these heat-activated buoyancy control designs have thus far proved impractical and have ultimately failed during repeated cycling in ocean testing. JPL has demonstrated fully reversible 10 C encapsulated wax phase change, which can be used to change buoyancy without electrical hydraulic pumps. This technique has greatly improved heat transfer and much better reversibility than previous designs. Power Generation: Ocean Thermal Energy Conversion (OTEC) systems have been designed that transfer deep, cold sea water to the surface to generate electricity using turbine cycles with ammonia or water as the working fluid. JPL has designed several UUV systems: 1) Using a propeller water turbine to generate power on a gliding submersible; 2) Employing a compact CO2 turbine cycle powered by moving through thermoclines; and 3) Using melted wax to directly produce power through a piston-geared generator.

submersible↗

Compressor-less Hydrogen Refueling Station Using Thermal Compression

The goal of this project was to demonstrate the technical and economic feasibility of using thermal compression to create the hydrogen pressure necessary to operate vehicle hydrogen fueling stations. The concept of utilizing the exergy within liquid hydrogen to build pressure rather than mechanical components such as compressors or cryogenic liquid pumps has several advantages. In theory, the compressor-less hydrogen station will have lower operating and maintenance costs because the compressors found in conventional stations require large amounts of electricity to run and are prone to mechanical breakdowns. The thermal compression station also utilizes some of the energy used to liquefy the hydrogen as work to build pressure, this is energy that in conventional stations is lost as heat to the environment.

08 HYDROGEN↗

Oil‐Free, High-Temperature Heat Transfer Fluid Circulator

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems How Mohawk and Velo3Dare Printing the Future of Energy

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗

An analysis of thermal stress and gas bending effects on vibrations of compressor rotor stages

A preliminary study conducted by Kerrebrock et al. (1976) has shown that the torsional rigidity of untwisted thin blades of a transonic compressor can be reduced significantly by transient thermal stresses. The aerodynamic loads have various effects on blade vibration. One effect is that gas bending loads may result in a bending-torsion coupling which may change the characteristics of the torsion and bending vibration of the blade. For a general study of transient-temperature distribution within a rotor stage, a finite-element heat-conduction analysis was developed. The blade and shroud are divided into annular elements. With a temperature distribution obtained from the heat-conduction analysis and a prescribed gas bending load distribution along the blade span, the static deformation and moment distributions of the blade can be solved iteratively using the finite-element method. The reduction of the torsional rigidity of pretwisted blades caused by the thermal stress effect is then computed. The dynamic behavior of the blade is studied by a modified Galerkin's method.

Chen, L.-T.↗

Exprimental Results of the First Two Stages of an Advanced Transonic Core Compressor Under Isolated and Multi-Stage Conditions.

NASA's Environmentally Responsible Aviation (ERA) Program calls for investigation of the technology barriers associated with improved fuel efficiency for large gas turbine engines. Under ERA, the highly loaded core compressor technology program attempts to realize the fuel burn reduction goal by increasing overall pressure ratio of the compressor to increase thermal efficiency of the engine. Study engines with overall pressure ratio of 60 to 70 are now being investigated. This means that the high pressure compressor would have to almost double in pressure ratio while keeping a high level of efficiency. NASA and GE teamed to address this challenge by testing the first two stages of an advanced GE compressor designed to meet the requirements of a very high pressure ratio core compressor. Previous test experience of a compressor which included these front two stages indicated a performance deficit relative to design intent. Therefore, the current rig was designed to run in 1-stage and 2-stage configurations in two separate tests to assess whether the bow shock of the second rotor interacting with the upstream stage contributed to the unpredicted performance deficit, or if the culprit was due to interaction of rotor 1 and stator 1. Thus, the goal was to fully understand the stage 1 performance under isolated and multi-stage conditions, and additionally to provide a detailed aerodynamic data set for CFD validation. Full use was made of steady and unsteady measurement methods to understand fluid dynamics loss source mechanisms due to rotor shock interaction and endwall losses. This paper will present the description of the compressor test article and its measured performance and operability, for both the single stage and two stage configurations. We focus the paper on measurements at 97% corrected speed with design intent vane setting angles.

transonic compressors↗

Effects of Cold Temperature and Main Compressor Intercooling on Recuperator and Recompression Cycle Performance

<span>This study investigates the effects of cold supercritical CO2 (sCO2) temperatures, compressor inlet pressures, and main compressor intercooling on the efficiency and specific power of recompression sCO2 cycles. Reducing the cold sCO2 temperature increases the compressor inlet density, thus reducing required compression power and increasing cycle thermal efficiency. &nbsp;Similarly, main compressor intercooling improves the specific power of a recompression cycle, reducing sCO2 mass flow, cycle size and cost for a given power output, though it is also shown to lead to an internal pinch point in the low temperature recuperator. Strategies for remediation of internal pinch points for recuperators as well as for the main CO2 cooler and the flue gas cooler are discussed, and apply to recompression cycles for all sCO2 applications.&nbsp; Upfront consideration of these remediation strategies is essential to determine attainable sCO2 cycle operating conditions and component sizing requirements.</span>

Weiland, Nathan↗

Effects of Cold Temperature and Main Compressor Intercooling on Recuperator and Recompression Cycle Performance

<span>This study investigates the effects of cold supercritical CO2 (sCO2) temperatures, compressor inlet pressures, and main compressor intercooling on the efficiency and specific power of recompression sCO2 cycles. Reducing the cold sCO2 temperature increases the compressor inlet density, thus reducing required compression power and increasing cycle thermal efficiency. &nbsp;Similarly, main compressor intercooling improves the specific power of a recompression cycle, reducing sCO2 mass flow, cycle size and cost for a given power output, though it is also shown to lead to an internal pinch point in the low temperature recuperator. Strategies for remediation of internal pinch points for recuperators as well as for the main CO2 cooler and the flue gas cooler are discussed, and apply to recompression cycles for all sCO2 applications.&nbsp; Upfront consideration of these remediation strategies is essential to determine attainable sCO2 cycle operating conditions and component sizing requirements.</span>

White, Chuck↗

Preliminary conceptual design and weight of a one-megawatt space-based laser power station utilizing a solar-pumped iodine lasant

A preliminary conceptual design of a space-based solar-pumped iodide laser emitting 1 MW of laser power for space-to-space power transmission is described. A near-parabolic solar collector focuses sunlight onto the t-C4F9I lasant within a transverse-flow optical cavity. Using waste heat, a thermal system supplies compressor and auxiliary power. The major system components are designed with weight estimates assigned. In particular, it is found that laser efficiency is not a dominant weight factor, the dominant factor being the laser transmission optics. The station mass is 92,000 kg, requiring approximately eight Shuttle flights to LEO, where an orbital transfer vehicle can transport it to the final altitude of 6378 km.

De Young, R. J.↗

Nonlinear Acoustics Used To Reduce Leakage Flow

Leakage and wear are two fundamental problems in all traditional turbine seals that contribute to an engine's inefficiency. The solutions to seal leakage and wear conflict in the conventional design space. Reducing the clearance between the seal and rotating shaft reduces leakage but increases wear because of increased contact incidents. Increasing the clearance to reduce the contact between parts reduces wear but increases parasitic leakage. The goal of this effort is to develop a seal that restricts leakage flow using acoustic pressure while operating in a noncontacting manner, thereby increasing life. In 1996, Dr. Timothy Lucas announced his discovery of a method to produce shock-free high-amplitude pressure waves. For the first time, the formation of large acoustic pressures was possible using dissonant resonators. A pre-prototype acoustic seal developed at the NASA Glenn Research Center exploits this fundamental acoustic discovery: a specially shaped cavity oscillated at the contained fluid's resonant frequency produces high-amplitude acoustic pressure waves of a magnitude approaching those required of today's seals. While the original researchers are continuing their development of acoustic pumps, refrigeration compressors, and electronic thermal management systems using this technology, the goal of researchers at Glenn is to apply these acoustic principles to a revolutionary sealing device. When the acoustic resonator shape is optimized for the sealing device, the flow from a high-pressure cavity to a low-pressure cavity will be restricted by a series of high-amplitude standing pressure waves of higher pressure than the pressure to be sealed. Since the sealing resonator cavity will not touch the adjacent sealing structures, seal wear will be eliminated, improving system life. Under a cooperative agreement between Glenn and the Ohio Aerospace Institute (OAI), an acoustic-based pre-prototype seal was demonstrated for the first time. A pressurized cavity was attached to one end of the resonator while the other end remained open to ambient pressure. Measurements were taken at several values of applied pressure with the assembly stationary, oscillated at an off-resonance frequency, and then oscillated on-resonance. The three cases show that the flow through the conical resonator can be reduced by oscillating the resonator at the resonance frequency of the air contained within the cavity. The results are currently being compared with results obtained from a commercial computational fluid dynamics code. The objective is to improve the design through numerical simulation before fabricating a next-generation prototype sealing device. Future work is aimed at implementing acoustic seal design improvements to further reduce the leakage flow rate through the device and at reducing the device's overall size.

Daniels, Christopher C.↗

Modeling the Integrated Thermal Amine Scrubber and Air Cooled-Temperature Swing Adsorbent Compressor

As part of a larger CO2 removal architecture study, a model was developed in Aspen Custom Modeler of the Thermal Amine Scrubber (TAS), an ISS flight experiment intended to scrub CO2 from the cabin air. In order to minimize mass losses, it was determined the TAS should work in conjunction with the Air Cooled-Temperature Swing Adsorption Compressor (AC-TSAC) to reduce the CO2 for O2 production. First the TAS removes CO2 from the cabin atmosphere, then the AC-TSAC compresses the CO2 and feeds it in a steady steam to a Sabatier or Bosch process. This document details an effort to add a model of the AC-TSAC to the existing TAS model to determine if the two hardware systems will have deleterious effects on each other’s performance. It was found the AC-TSAC provided sufficient vacuum for the TAS’s desorption to occur, but not the same level of vacuum as space vacuum. This lower quality vacuum led to a reduction in the total cyclical uptake capacity of the TAS and thus a lower CO2 removal under the same conditions. The TAS did not remove enough CO2 to fill the AC-TSAC bed to capacity during the production phase which caused the AC-TSAC to run out of CO2 during production. This renders the addition of the AC-TSAC pointless. It is believed these effects can be overcome with a redesign of one or both systems.

TAS↗