Dynamic modelling of flexible dispatch in a novel nuclear-solar integrated energy system with thermal energy storage
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
A new Dynamic zOnal Model with Air-diffuser (DOMA) was developed. Several case studies were investigated and tested to evaluate and validate this program using measurement data. This new model was integrated into a TRaNsient SYstems Simulation program library and coupled with the multi-zone thermal model. The DOMA/TRNSYS coupled model was then used to predict room temperature distribution over an entire day of a single-zone building. The results show that increasing the heating outputs of the electric floor system, for example, from 75 to 200 W/m 2 , would not effectively improve the indoor thermal comfort, since the thermostat will reach the set point first and then turn off the system before the room gets enough heat and reach a comfortable level. This indicates the importance of selecting an appropriate location and set point for the thermostat when using a floor heating system. This potential thermal comfort issue can only be identified through the two-node model with a dynamic zonal model rather than the conventional PMV model, which thus suggests that for optimizing indoor thermal comfort of a building equipped with a time-sensitive control strategy and/or HVAC system, the TSENS results obtained from the two-node model integrated with DOMA are more appropriate than PMVs.
Thermal fluctuations cause perturbations of fluid-fluid interfaces and highly nonlinear hydrodynamics in multiphase flows. In this work, we develop a novel multiphase smoothed dissipative particle dynamics model. This model accounts for both bulk hydrodynamics and interfacial fluctuations. Interfacial surface tension is modeled by imposing a pairwise force between SDPD particles. We show that the relationship between the model parameters and surface tension, previously derived under the assumption of zero thermal fluctuation, is accurate for fluid systems at low temperature but overestimates the surface tension for intermediate and large thermal fluctuations. To analyze the effect of thermal fluctuations on surface tension, we construct a coarse-grained Euler lattice model based on the mean field theory and derive a semi-analytical formula to directly relate the surface tension to model parameters for a wide range of temperatures and model resolutions. We demonstrate that the present method correctly models the dynamic processes, such as bubble coalescence and capillary spectra across the interface.
Following the reports of water accumulation in the Extravehicular Mobility Unit (EMU) helmet during the ISS US EVA-80, various efforts for mitigation and further understanding of this phenomenon have been undertaken with the goal of prevention and to ensure crew safety in future EVAs. In support of this goal, a combination of Thermal Desktop thermal modeling and Computational Fluid Dynamics (CFD) has been performed in order to characterize the performance of the EMU components, specifically those within the ventilation/cooling water loops. This modeling effort evaluates the dry/wet gas pressure drop and flow distribution through gas and liquid flow paths using CFD, as well as a two-phase flow assessment of condensation production and water separation/removal performance using an integrated Thermal Desktop model of important EMU ventilation loop components. The models assess this overall thermal-fluid performance in comparison with previous existing models, design points, and historical EVA data using their inputs.
Following the reports of water accumulation in the Extravehicular Mobility Unit (EMU) helmet during the ISS US EVA-80, various efforts for mitigation and further understanding of this phenomenon have been undertaken with the goal of prevention and to ensure crew safety in future EVAs. In support of this goal, a combination of Thermal Desktop thermal modeling and Computational Fluid Dynamics (CFD) has been performed in order to characterize the performance of the EMU components, specifically those within the ventilation/cooling water loops. This modeling effort evaluates the dry/wet gas pressure drop and flow distribution through gas and liquid flow paths using CFD, as well as a two-phase flow assessment of condensation production and water separation/removal performance using an integrated Thermal Desktop model of important EMU ventilation loop components. The models assess this overall thermal-fluid performance in comparison with previous existing models, design points, and historical EVA data using their inputs.
A coupled ferromagnetic–thermal solver is developed for the multiphysics and multiscale modeling and simulation of nonlinear magnetic materials in the time domain. By adopting a temperature-dependent dynamic hysteresis model, the power loss is characterized and calculated from the solution of Maxwell's equations, which serves as the heat source for the thermal problem. By solving the thermal problem, the temperature change is obtained, and its effect on the magnetic material property can be quantified, which is then coupled back to Maxwell's equations. Due to different temporal characteristics of the electromagnetic fields and the thermal response, the resulting coupled ferromagnetic–thermal system has two significantly different time scales. Such a temporal multiscale issue is addressed with a proposed multiscale time integration method to account for the multiscale coupling between the two physics. With the proposed multiphysics and multiscale modeling method, both the electromagnetic fields and the thermal responses can be captured accurately in a dynamic operation.
We consider the problem of optimizing the cost of procuring electricity for a large collection of homes managed by a load serving entity, by pre-cooling or pre-heating the thermal inertial loads in the homes to avoid procuring power during periods of peak electricity pricing. We would like to accomplish this objective in a completely privacy-preserving and model-free manner, that is, without direct access to the state variables (temperatures or power consumption) or the dynamical models (thermal characteristics) of individual homes, while guaranteeing personal comfort constraints of the consumers. We propose a two-stage optimization and control framework to address this problem. In the first stage, we use a long short-term memory (LSTM) network to predict hourly electricity prices, based on historical pricing data and weather forecasts. Given the hourly price forecast and thermal models of the homes, the problem of designing an optimal power consumption trajectory that minimizes the total electricity procurement cost for the collection of thermal loads can be formulated as a large-scale integer program (with millions of variables) due to the on-off cyclical dynamics of such loads. We provide a simple heuristic relaxation to make this large-scale optimization problem model-free and computationally tractable. In the second stage, we translate the results of this optimization problem into distributed open-loop control laws that can be implemented at individual homes without measuring or estimating their state variables, while simultaneously ensuring consumer comfort constraints. We demonstrate the performance of this approach on a large-scale test case comprising of 500 homes in the Houston area and benchmark its performance against a direct model-based optimization and control solution.
Presentation detailing dynamic modeling progress on a heat pipe integrated thermal battery system.
GridLAB-D is a power distribution systems simulation and analysis tool developed by Pacific Northwest National Laboratory. Although GridLAB-D and its underlying residential load model has been used in a variety of power systems analyses, comprehensive documentation of the derivation of the residential house model has not been formally published. The purpose of this technical support document is to serve as a comprehensive resource for the thermal dynamics modeling and house definition implemented in GridLAB-D. It covers model derivation, parameter definitions, and implementation steps in the codebase.
A distributed energy management system for community microgrids is developed here. Unlike a centralized optimization-based energy management system, it schedules distributed energy resources and energy storage systems, as well as residential appliances, indirectly through iterative interaction between the microgrid central controller and home energy management systems, based on price signals. In each iteration, the microgrid central controller adjusts the scheduling of distributed energy resources and energy storage systems at the microgrid level. Meanwhile, the home energy management system of each house adjusts the scheduling of residential appliances. Then, the energy price at each bus is updated according to the unbalanced power between generation and demand. The optimization converges when the unbalanced power of all buses is close to zero, i.e., the microgrid central controller and home energy management systems reach an agreement on the energy price and generation/consumption. In particular, a detailed thermal dynamic model of the house is integrated into the HEMS scheduling for intelligent control of the heating, ventilation, and air-conditioning system by customers. Lastly, the distribution network is also considered to make the energy price signal locational. Results of case studies validate the efficacy of the proposed distributed energy management system.
Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. Here, the applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.
The author has identified the following significant results. Results of studies of the oceanography of the northern Gulf of California (Mexico) are reported. A remote, instrumented buoy measuring and telemetering oceanographic data by ERTS-1 satellite was designed, constructed, deployed, and tested. Regular cruises by a research ship on a pattern of 47 oceanographic stations collected data which are analyzed and referenced to analysis of ERTS-1 satellite imagery. A thermal dynamic model of current patterns in the northern Gulf of California is proposed. Findings are examined in relation to the model.
Topics concerning the modeling, analysis, and optimization of large space structures are discussed including structure-control interaction, structural and structural dynamics modeling, thermal analysis, testing, and design.
This paper presents a coupled elastic-thermal dynamic model and a quasi-static strategy on the analysis of the reflector dynamics in the space mission. The linearized model, its natural frequencies and mode shapes are then derived upon the nonlinear static equilibrium of the structure. The numerical example is provided to fully adapt the strategy and investigate the dynamic behaviors of the structure. Finally the proposed method is applied on the sample of the deployable mesh reflector and the simulation results are presented. The research work delivered in the paper will be used to design the feedback surface in future.
A real time thermal monitoring and prediction system (TMPS) is provided for use in monitoring and operating a transformer. The TMPS may be used to estimate a maximum loading level for the transformer over a future time period using a dynamic thermal model for the transformer and ambient temperature forecasts. The transformer may be loaded to its maximum loading level during power congestion or a service restoration process.
Although computational fluid dynamics (CFD) has been widely adopted to improve data center thermal management, the high computational demand limits its applications, such as multivariate optimal design and operation. Fast fluid dynamics (FFD), which has been applied for fast airflow simulation, shows great potential. However, few research applied FFD for optimal design and operation of data center thermal management. This research improves the FFD model for data centers and conducts a comprehensive evaluation and demonstration. First, the FFD model is improved by solving the advection and diffusion equations together using an upwind scheme instead of a semi-Lagrangian advection solver in the conventional FFD model. Second, new features for data centers are added, such as a pressure correction method to simulate plenum airflow and dynamic boundary conditions for IT racks. The new FFD model is first validated with two indoor environment cases and the results show that the new FFD model has slightly better overall prediction accuracy and faster speed compared to the conventional FFD model. It is also observed that both FFD models achieve acceptable accuracy, except for a few localized disparities with experimental data, which might be due to simplified handling of turbulence viscosity near the boundaries. Furthermore, validation with a real data center shows that the FFD model achieves a similar level of accuracy as CFD when compared to the experimental measurements with some level of uncertainties. It is then demonstrated for data center optimal design and operation, which saves 53.4–58.8% of annual energy while still meeting the thermal requirements. In conclusion, with a much faster speed and comparable accuracy compared to CFD, the FFD model parallelized on a graphics processing unit is promising for practical model-based data center early design and operation.
Computational fluid dynamics simulations of solar-thermal dry reforming of methane using a parabolic trough configuration were performed. Parametric simulations of different combinations of gas flow rate, receiver tube emissivity, and geometric concentration ratio were conducted to determine configurations that could achieve the required catalyst temperatures of at least 700 °C to achieve high conversion of CH4 and CO2 to H2 and CO. Results showed that the concentration ratio of the parabolic trough collector had to be increased from ~70 to ~120 and the receiver-tube emissivity had to be reduced to ~0.2 to achieve bulk average catalyst temperatures of greater than 700 °C. Lower gas flow rates also reduced enthalpic heat losses and increased catalyst temperatures.
This paper presents dynamic modeling of the crew exploration vehicle (Orion) active thermal control system (ATCS) using Simulink (Simulink, developed by The MathWorks). The model includes major components in ATCS, such as heat exchangers and radiator panels. The mathematical models of the heat exchanger and radiator are described first. Four different orbits were used to validate the radiator model. The current model results were compared with an independent Thermal Desktop (TD) (Thermal Desktop, PC/CAD-based thermal model builder, developed in Cullimore & Ring (C&R) Technologies) model results and showed good agreement for all orbits. In addition, the Orion ATCS performance was presented for three orbits and the current model results were compared with three sets of solutions- FloCAD (FloCAD, PC/CAD-based thermal/fluid model builder, developed in C&R Technologies) model results, SINDA/FLUINT (SINDA/FLUINT, a generalized thermal/fluid network-style solver ) model results, and independent Simulink model results. For each case, the fluid temperatures at every component on both the crew module and service module sides were plotted and compared. The overall agreement is reasonable for all orbits, with similar behavior and trends for the system. Some discrepancies exist because the control algorithm might vary from model to model. Finally, the ATCS performance for a 45-hr nominal mission timeline was simulated to demonstrate the capability of the model. The results show that the ATCS performs as expected and approximately 2.3 lb water was consumed in the sublimator within the 45 hr timeline before Orion docked at the International Space Station.