Search NASA⌕ Search

SEARCH · Search NASA

Results for “time correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Time-correlated gust loads using matched filter theory and random process theory - A new way of looking at things

This paper describes and illustrates two ways of performing time-correlated gust-load calculations. The first is based on Matched Filter Theory; the second on Random Process Theory. Both approaches yield theoretically identical results and represent novel applications of the theories, are computationally fast, and may be applied to other dynamic-response problems. A theoretical development and example calculations using both Matched Filter Theory and Random Process Theory approaches are presented.

Pototzky, Anthony S.↗

A computer program to obtain time-correlated gust loads for nonlinear aircraft using the matched-filter-based method

NASA Langley Research Center has, for several years, conducted research in the area of time-correlated gust loads for linear and nonlinear aircraft. The results of this work led NASA to recommend that the Matched-Filter-Based One-Dimensional Search Method be used for gust load analyses of nonlinear aircraft. This manual describes this method, describes a FORTRAN code which performs this method, and presents example calculations for a sample nonlinear aircraft model. The name of the code is MFD1DS (Matched-Filter-Based One-Dimensional Search). The program source code, the example aircraft equations of motion, a sample input file, and a sample program output are all listed in the appendices.

Scott, Robert C.↗

A search in the COS-B data base for correlated time variability in regions containing objects of interest

As is well known, association of the gamma-ray sources with celestial objects is, in general, difficult on a pure positional basis, while correlated time variability could obviously provide such proof. This technique can be employed on regions of the gamma-ray sky containing interesting objects of known variability at some wavelength even in the absence of a recognized gamma-ray excess with the aim to extract a weak but predictable signal from the surrounding noise. This technique is applied here on a longer variability time scale, generally of the order of days. Photons coming from the sky regions centered on the various celestial objects considered were selected with energies 100 MeV and with arrival directions within an energy-dependent area of radius of approx 6 deg at 100 MeV. In order to construct a time profile of such photons, their arrival times were grouped in bins of dimensions defined by the available photons number and by the value of the period searched for.

Caraveo, P. A.↗

Response time correlations for platinum resistance thermometers in flowing fluids

The thermal response of two types of Platinum Resistance Thermometers (PRT's), which are being considered for use in the National Transonic Wind Tunnel Facility, were studied. Response time correlations for each PRT, in flowing water, oil and air, were established separately. A universal correlation, tau WOA = 2.0 + 1264, 9/h, for a Hy-Cal Sensor (with a reference resistance of 100 ohm) within an error of 20% was established while the universal correlation for the Rosemount Sensor (with a reference resistance of 1000 ohm), tau OA = 0.122 + 1105.6/h, was found with a maximum percentage error of 30%. The correlation for the Rosemount Sensor was based on air and oil data only which is certainly not sufficient to make a correlation applicable to every condition. Therefore, the correlation needs more data to be gathered in different fluids. Also, it is necessary to state that the calculation of the parameter, h, was based on the available heat transfer correlations, whose accuracies are already reported in literature uncertain within 20-30%. Therefore, the universal response constant correlations established here for the Hy-Cal and Rosemount sensors are consistent with the uncertainty in the input data and are recommended for future use in flowing liquids and gases.

Pandey, D. K.↗

Space-Time Correlations and Spectra of Wall Pressure in a Turbulent Boundary Layer

Measurements of the statistical properties of the fluctuating wall pressure produced by a subsonic turbulent boundary layer are described. The measurements provide additional information about the structure of the turbulent boundary layer; they are applicable to the problems of boundary-layer induced noise inside an airplane fuselage and to the generation of waves-on water. The spectrum of the wall pressure is presented in dimensionless form. The ratio of the root-mean-square wall pressure to the free-stream dynamic pressure is found to be a constant square root of bar P(sup 2)/q(sub infinity) = 0.006 independent of Mach number and Reynolds number. In addition, space- time correlation measurements in the stream direction show that pressure fluctuations whose scale is greater than or equal to 0.3 times the boundary-layer thickness are convected with the convection speed U(sub c) = 0.82U(sub infinity) where U(infinity) is the free-stream velocity and have lost their identity in a distance approximately equal to 10 boundary-layer thicknesses.

Willmarth, W. W.↗

Atmospheric correlation-time measurements and effects on coherent Doppler lidar

The time for which the backscatter from an ensemble of atmospheric aerosol particles remains coherent was studied by using a pulsed TEA CO2 lidar with coherent detection. Experimental results are compared with predictions by using model pulse shapes appropriate for TEA CO2 laser transmitters. The correlation time of the backscatter return signal is important in studies of atmospheric turbulence and its effects on optical propagation and backscatter. Techniques for its measurement are discussed and evaluated.

Ancellet, Gerard M.↗

Space-time correlation measurements in a compressible turbulent boundary layer

Single and dual hot-wire probes have been used to accomplish a first look at the large-eddy structure of a supersonic turbulent boundary layer. The investigation was performed in an axisymmetric turbulent boundary layer in the Ames High Reynolds Number wind tunnel. Freestream Mach number was 2.97, the boundary layer was approximately 1.2 cm thick, and Reynolds number = 15,000. Quantities measured were streamwise turbulence intensity and higher order statistics of mass-flow fluctuations, and space-time correlations of instantaneous streamwise velocity at two locations. Conditional sampling of the hot-wire signals was performed to detect the passage and describe the character of the large turbulent eddies. Results indicate that the large scale structure in compressible turbulence is similar to that at low subsonic flow speeds except at the boundary layer edge, where the intermittency region is narrowed in compressible flow.

Robinson, S. K.↗

A timed-correlated four-link Doppler Tracking system

Phase perturbations that occur in the following components of the one and two-way systems are considered: (1) one-way system (signal from A to B): station a oscillator - transmitter A antenna A - signal path - antenna B - receiver B station B oscillator - recording system B; (2) two-way system (signal from A to B back to A): station A oscillator - transmitter A - antenna A - signal path up - antenna B - transponder B - antenna B - signal path down - receiver A - station A oscillator - recording system A. A symmetrical one- and two-way system which can identify the place of origin of the fluctuation and quantify it so as to recover the unperturbed phase at a given moment of time by time-correlating the phase fluctuations obtained in the one- and two-way data taken at both stations is described

Vessot, R. F. C.↗

Time-Resolved PIV for Space-Time Correlations in Hot Jets

Temporally Resolved Particle Image Velocimetry (TR-PIV) is being used to characterize the decay of turbulence in jet flows a critical element for understanding the acoustic properties of the flow. A TR-PIV system, developed in-house at the NASA Glenn Research Center, is capable of acquiring planar PIV image frame pairs at up to 10 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered 6 nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centered along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space-time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number.

Wernet, Mark P.↗

Time Resolved PIV for Space-Time Correlations in Hot Jets

Temporally Resolved Particle Image Velocimetry (TR-PIV) is the newest and most exciting tool recently developed to support our continuing efforts to characterize and improve our understanding of the decay of turbulence in jet flows -- a critical element for understanding the acoustic properties of the flow. A new TR-PIV system has been developed at the NASA Glenn Research Center which is capable of acquiring planar PIV image frame pairs at up to 25 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered 6 nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centered along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space-time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number

Wernet, Mark P.↗

Response time correlations for platinum resistance thermometers

The 'plunge method' recommended by ASTM has been used to determine the time constant of 100-ohm platinum resistance thermometers (PRT) considered for use in the National Transonic Facility. It is shown that the response time of ventilated PRT can be correlated with the reciprocal of the heat transfer coefficient in a given field. Universal correlations are established for the 100- and 1000-ohm PRT with uncertainties of 20 and 30 percent, respectively. The correlations are found to be consistent with the uncertainty involved in heat transfer correlations available in the literature and are recommended for use in flowing liquids and gases.

Pandey, D. K.↗

Optimal filtering in the presence of unmodeled time correlated driving disturbances.

In many realistic data filtering problems, the cross correlation of the state estimation error and the state forcing function is unknown due to the poor knowledge of the time history of the forcing function. In this paper, the conservative and minimal approximation to the cross correlation terms is presented. It requires only the knowledge of the estimation error covariance and the forcing function covariance, with the choice of an associated free parameter left to the user. If the estimation error covariance and/or the forcing function covariance are bounded from above but not known exactly, the cross correlation approximation using those upper bounds remains conservative. This cross correlation approximation leads to a conservative approximation to the estimation error covariance matrix differential equation between measurement times. The free parameter is determined as the analytic solution to an associated optimal control problem. The procedure is expanded to include discrete linear measurement incorporation.

Fraser, D. C.↗

A Multiwavelength Search for Correlated Time Variations in the Brightest Egret Blazers

The February 1996 flare of 3C279 peaked at the highest gamma-ray intensity ever recorded for this object. Compton Gamma Ray Observatory (CGRO), Rossi X-Ray Timing Explorer (RXTE), Advanced Satellite For Cosmology and Astrophysics (ASCA), Roentgen Satellite (ROSAT), International Ultraviolet Explorer (IUE), Hubble Space Telescope (HST), Infrared Space Observatory (ISO) and 18 ground-based observatories participated in observations at various times during January and February 1996. The CGRO EGRET and RXTE light curves are correlated during the flare without any lag larger than the temporal resolution of about 1 day. We present simultaneous spectral energy distributions prior to and near the flare peak. The gamma-rays vary by more than the square of the observed infrared-optical flux change, which poses some problems for specific blazar models.

Urry, C. Megan↗

Precise timing correlation in telemetry recording and processing systems

Independent PCM telemetry data signals received from missiles must be correlated to within + or - 100 microseconds for comparison with radar data. Tests have been conducted to determine RF antenna receiving system delays; delays associated with wideband analog tape recorders used in the recording, dubbing and repdocuing processes; and uncertainties associated with computer processed time tag data. Several methods used in the recording of timing are evaluated. Through the application of a special time tagging technique, the cumulative timing bias from all sources is determined and the bias removed from final data. Conclusions show that relative time differences in receiving, recording, playback and processing of two telemetry links can be accomplished with a + or - 4 microseconds accuracy. In addition, the absolute time tag error (with respect to UTC) can be reduced to less than 15 microseconds. This investigation is believed to be the first attempt to identify the individual error contributions within the telemetry system and to describe the methods of error reduction within the telemetry system and to describe the methods of error reduction and correction.

Pickett, R. B.↗

Gravitational waves and red shifts - A space experiment for testing relativistic gravity using multiple time-correlated radio signals

A two-step satellite mission for improving the accuracy of gravitational wave detection and for observing actual gravity waveforms is proposed. The spacecraft would carry both a highly stable hydrogen maser, which would control a transmitter sending signals to earth, and a Doppler transponder operating in the two-way mode. The use of simultaneous one- and two-way Doppler transmissions offers four time records of frequency pulsations, which can reveal gravitational radiation at 1-10 MHz with an amplitude accuracy of a factor of six. The first mission phase would consist of a Shuttle launch into a highly eccentric orbit to obtain measurements of the gravitational redshift using gravitational potentials of different earth regions to establish that gravity is describable by a metric theory. Then, after a boost into a heliocentric orbit at 6 AU, the earth-satellite system could detect gravitational waves in the solar system, as well as bursts emitted by the collisions of supermassive black holes.

Smarr, L. L.↗