Search NASA⌕ Search

SEARCH · Search NASA

Results for “total internal reflection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Imaging exocytosis of single glucagon-like peptide-1 containing granules in a murine enteroendocrine cell line with total internal reflection fluorescent microscopy

To analyze the exocytosis of glucagon-like peptide-1 (GLP-1) granules, we imaged the motion of GLP-1 granules labeled with enhanced yellow fluorescent protein (Venus) fused to human growth hormone (hGH-Venus) in an enteroendocrine cell line, STC-1 cells, by total internal reflection fluorescent (TIRF) microscopy. We found glucose stimulation caused biphasic GLP-1 granule exocytosis: during the first phase, fusion events occurred from two types of granules (previously docked granules and newcomers), and thereafter continuous fusion was observed mostly from newcomers during the second phase. Closely similar to the insulin granule fusion from pancreatic {beta} cells, the regulated biphasic exocytosis from two types of granules may be a common mechanism in glucose-evoked hormone release from endocrine cells.

60 APPLIED LIFE SCIENCES↗

Elucidation of perovskite film micro-orientations using two-photon total internal reflectance fluorescence microscopy

The emergence of efficient hybrid organic-inorganic perovskite photovoltaic materials has caused the rapid development of a variety of preparation and processing techniques designed to maximize their performance. As processing methods continue to emerge, it is important to understand how the optical properties of these materials are affected on a microscopic scale. Here polarization resolved two-photon total internal reflectance microscopy (TIRFM) was used to probe changes in transition dipole moment orientation as a function of thermal annealing time in hybrid organic-inorganic lead iodide based perovskite (CH 3 NH 3 PbI 3 ) thin films on glass. These results show that as thermal annealing time is increased the distribution of transition moments pointing out-of-plane decreases in favor of forming areas with increased in-plane orientations. As a result, it was also shown through the axial sensitivity of TIRFM that the surface topography is manifested in the signal intensity and can be used to survey aspects of morphology in coincidence with the optical properties of these films.

36 MATERIALS SCIENCE↗

Nanofiber-Based Total Internal Reflection Microscopy for Characterizing Colloidal Systems at the Microscale

Bulk colloidal interactions are dictated by the physical properties of individual particles dispersed in solution. However, for many applications it remains challenging to predict system-level colloidal behavior. Comprehensive characterization typically requires disparate techniques that can observe correlations between microscale particle–surface interactions and physical properties of the particles. In this work, we present a unique tin dioxide (SnO2) nanofiber-based total internal reflection microscopy (TIRM) method to efficiently characterize colloidal behavior as a function of particle-level properties in complex fluidic conditions. We develop and model the device physics to understand the physical underpinnings of the raw device data and then use these models to design proof-of-concept experiments to verify device function. Statistical trends in the data collected from a nominal system of 80 nm gold nanoparticles correspond to theoretical predictions as we vary key design parameters such as particle size, surface charge, and solution ionic strength. Lastly, we consider the practical limitations of the technique gleaned from our studies and offer suggestions for utilizing the platform to quantitatively analyze nonideal colloidal systems with distributed or heterogeneous system parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Total internal reflection enabled wide-field Coherent anti-Stokes Raman scattering microscopy

A system is provided. The system has a femtosecond oscillator to generate pulses used for pump and probe beams. A photonic crystal fiber is disposed in a path of the probe beam and produces pulses for a chirped probe beam. A high NA objective receives the pump and the chirped probe beam, redirects the received beams through a dielectric substrate towards an interface between a sample and the dielectric substrate to cause total internal reflection (TIR) at the sample-substrate interface, and produces corresponding evanescent waves in a portion of the sample adjacent to the sample-substrate interface, and collects a backward-propagating beam of pulses of responsive light. The portion of the sample illuminated by the evanescent waves emits responsive light. The dielectric substrate is transparent to the responsive light, the pump and the chirped probe beam. An image is produced having a specific image size using the received backward-propagating beam.

Doughty, Benjamin L.↗

Total internal reflection enabled wide-field coherent anti-Stokes Raman scattering microscopy

Wide-field coherent anti-Stokes Raman scattering (CARS) microscopy offers an attractive means for the rapid and simultaneous acquisition of vibrationally resolved images across a large field of view. A major challenge in the implementation lies in how to achieve sufficiently strong excitation fields necessary to drive the third-order optical responses over the large focal region. Here, we report a new wide-field CARS microscope enabled by a total internal reflection excitation scheme using a femtosecond Ti:Sapphire oscillator to generate pump and broadband near-infrared Stokes pulses. The spectrally broad Stokes pulse, in combination with its inherent chirp, offers not only access to a wide range of Raman modes spanning ∼ <#comment/> 1000 to ∼ <#comment/> 3500 c m − <#comment/> 1 but also a straightforward means to select vibrational transitions within this range by simply varying the time delay between the pulses. The unique capabilities of this wide-field CARS microscope were validated by acquiring high-quality CARS images from the model and complex biological samples on conventional microscope coverslips.

Doughty, Benjamin (ORCID:0000000164299329)↗

Total internal reflection enabled wide-field coherent anti-Stokes Raman scattering microscopy

Wide-field coherent anti-Stokes Raman scattering (CARS) microscopy offers an attractive means for the rapid and simultaneous acquisition of vibrationally resolved images across a large field of view. A major challenge in the implementation lies in how to achieve sufficiently strong excitation fields necessary to drive the third-order optical responses over the large focal region. Here, we report a new wide-field CARS microscope enabled by a total internal reflection excitation scheme using a femtosecond Ti:Sapphire oscillator to generate pump and broadband near-infrared Stokes pulses. The spectrally broad Stokes pulse, in combination with its inherent chirp, offers not only access to a wide range of Raman modes spanning ${\sim}{1000}$ to ${\sim}{3500}\;{{\rm cm}^{- 1}}$ but also a straightforward means to select vibrational transitions within this range by simply varying the time delay between the pulses. The unique capabilities of this wide-field CARS microscope were validated by acquiring high-quality CARS images from the model and complex biological samples on conventional microscope coverslips.

36 MATERIALS SCIENCE↗

Extrinsic Absorption Pathways in Vanadium-Doped SiC Measured Using a Total Internal Reflection Geometry

Vanadium-doped SiC is under study for high-power photoconductive switches and is receiving increased attention as a potential material system for quantum computing, as the V can act as a quantum emitter at telecom wavelengths. Knowledge of the defect-mediated electronic transition pathways from sub-bandgap illumination in this material with low absorption and multi-photon and multi-path transition probability is important in optimizing quantum efficiency. Herein, the optical transitions of vanadium-doped SiC for two polytypes as a function of dopant concentration using a total internal reflection (TIR) geometry are examined. Furthermore, normalized quantum efficiency is reported and correlated with both dopant concentrations (V, N, B, and Al) measured by secondary ion mass spectroscopy (SIMS) and absorption measurements. Although both polytypes respond well to 532 nm light, efficiency at longer wavelengths does not correlate 1:1 with absorption coefficient and strongly depends on the polytype and net background co-dopant concentration. This has important implications for efficient excitation of both carriers for optoelectronics and for the use of V as a quantum emitter.

36 MATERIALS SCIENCE↗

Total-internal reflection elastic metasurfaces: design and application

An acoustic shield for protecting a vibrational sensitive device includes a first unit cell and a second unit cell. The first unit cell includes a first locally resonant unit. The first locally resonant unit controls a first phase gradient and the first unit cell includes a first surface. The second unit cell includes a second surface proximate to the first surface. The second unit cell includes a second locally resonant unit embedded along the second interface. The second locally resonant unit controls a second phase gradient. The first phase gradient is different from the second phase gradient. The first unit cell and the second unit cell comprise a super cell. The acoustic shield is configured such that a vibrational wave from a first side of the super cell to a second side of the super cell is substantially attenuated.

Walsh, Timothy↗

The development of optical microscopy techniques for the advancement of single-particle studies

Single particle orientation and rotational tracking (SPORT) has recently become a powerful optical microscopy tool that can expose many molecular motions. Unfortunately, there is not yet a single microscopy technique that can decipher all particle motions in all environmental conditions, thus there are limitations to current technologies. Within, the two powerful microscopy tools of total internal reflection and interferometry are advanced to determine the position, orientation, and optical properties of metallic nanoparticles in a variety of environments. Total internal reflection is an optical phenomenon that has been applied to microscopy to produce either fluorescent or scattered light. The non-invasive far-field imaging technique is coupled with a near-field illumination scheme that allows for better axial resolution than confocal microscopy and epi-fluorescence microscopy. By controlling the incident illumination angle using total internal reflection fluorescence (TIRF) microscopy, a new type of imaging probe called “non-blinking” quantum dots (NBQDs) were super-localized in the axial direction to sub-10-nm precision. These particles were also used to study the rotational motion of microtubules being propelled by the motor protein kinesin across the substrate surface. The same instrument was modified to function under total internal reflection scattering (TIRS) microscopy to study metallic anisotropic nanoparticles and their dynamic interactions with synthetic lipid bilayers. Utilizing two illumination lasers with opposite polarization directions at wavelengths corresponding to the short and long axis surface plasmon resonance (SPR) of the nanoparticles, both the in-plane and out-of-plane movements of many particles could be tracked simultaneously. When combined with Gaussian point spread function (PSF) fitting for particle super-localization, the binding status and rotational movement could be resolved without degeneracy. TIRS microscopy was also used to find the 3D orientation of stationary metallic anisotropic nanoparticles utilizing only long-axis SPR enhancement. The polarization direction of the illuminating light was rotated causing the relative intensity of p-polarized and s-polarized light within the evanescent field to change. The interaction of the evanescent field with the particles is dependent on the orientation of the particle producing an intensity curve. This curve and the in-plane angle can be compared with simulations to accurately determine the 3D orientation. Differential interference contrast (DIC) microscopy is another non-invasive far-field technique based upon interferometry that does not rely on staining or other contrast enhancing techniques. In addition, high numerical aperture condensers and objectives can be used to give a very narrow depth of field allowing for the optical tomography of samples, which makes it an ideal candidate to study biological systems. DIC microscopy has also proven itself in determining the orientation of gold nanorods in both engineered environments and within cells. Many types of nanoparticles and nanostructures have been synthesized using lithographic techniques on silicon wafer substrates. Traditionally, reflective mode DIC microscopes have been developed and applied to the topographical study of reflective substrates and the imaging of chips on silicon wafers. Herein, a laser-illuminated reflected-mode DIC was developed for studying nanoparticles on reflective surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated freeform optical couplers

Reflecting light beams off of microscale three-dimensional (3D) freeform surfaces can yield highly efficient coupling into and out of optical waveguides, optical fibers, and photonic chips. The structure of the 3D freeform reflective surface determines the shape of the reflected beam. This allows freeform reflectors to control the mode profile, rotation angle, and divergence angle of light beams. Control of beam shape enables mode matching between source output mode and target input mode, which results in low-loss optical coupling. An inventive freeform reflective surface can direct light beams in plane or out of plane via specular reflection or total internal reflection. A photonic integrated circuit with this type of freeform optical coupler can operate with a bandwidth range of at least 400 nm, potentially encompassing all visible or telecommunications wavelengths, and can be volume manufactured in photonic chips.

Yu, Shaoliang↗

Multimodal Broadband Vibrational Sum Frequency Generation (MM-BB-V-SFG) Spectrometer and Microscope

A broadband sum frequency generation (BB-SFG) spectrometer with multimodal (MM) capabilities was constructed, which could be routinely reconfigured for tabletop experiments in reflection, transmission, and total internal reflection (TIR) geometries, as well as microscopic imaging. The system was constructed using a Ti:sapphire amplifier (800 nm, pulse width = 85 fs, repetition rate = 2 kHz), an optical parameter amplification (OPA) system for production of broadband IR pulses tunable between 1000 and 4000 cm –1 , and two Fabry–Pérot etalons arranged in series for production of narrowband 800 nm pulses. The key feature allowing the MM operation was the nearly collinear alignment of the visible (fixed, 800 nm) and infrared (tunable, 1000–4000 cm –1 ) pulses which were spatially separated. Physical insights discussed in this paper include the comparison of spectral bandwidth produced with 40 and 85 fs pump beams, the improvement of spectral resolution using etalons, the SFG probe volume in bulk analysis, the normalization of SFG signals, the stitching of multiple spectral segments, and the operation in different modes for air/liquid and adsorbate/solid interfaces, bulk samples, as well as spectral imaging combined with principle component analysis (PCA). Finally, the SFG spectral features obtained with the MM-BB-SFG system were compared with those obtained with picosecond-scanning-SFG system and high-resolution BB-SFG system (HR-BB-SFG) for dimethyl sulfoxide, α-pinene, and various samples containing cellulose (purified commercial products, Cladophora cell wall, cotton and flax fibers, and onion epidermis cell wall).

47 OTHER INSTRUMENTATION↗

Acceleration of electrons by a laser pulse at its output onto an optical surface of the vacuum – transparent medium interface. Laser synchrotron

We consider the electron dynamics in the field of an electromagnetic wave produced at the vacuum – transparent medium interface upon reflection from the boundary, close to total internal reflection. The propagation velocity of a constant phase of the electromagnetic wave along the interface can vary from c/n to infinity (c is the speed of light in vacuum, and n is the refractive index of the medium at the interface). In this case, there emerge regions of positive and negative phases of the field with wavelengths, approximately equal to half the wavelength of the original laser beam, which can propagate at a speed close to that of light in vacuum. If a beam of relativistic electrons propagates along the surface, they can gain energy and accelerate, as well as radiate. With closed trajectories of electron motion, a laser synchrotron will be implemented as a result of many acceleration cycles. (extreme laser radiation: physics and fundamental applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗