Search NASA⌕ Search

SEARCH · Search NASA

Results for “trimmed sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Solvent hold tank sample results for MCU-15-802-803-804-805-806-807 August monthly sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-802-803-804-805-806-807), pulled on 08/31/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-802-803-804-805-806-807 indicated a low concentration (~ 45 % of nominal) of the suppressor (TiDG) and a slightly lower than nominal concentration of the modifier (Cs-7SB) in the solvent. The extractant (MaxCalix) concentration was at its nominal value. Based on this current monthly sample, the levels of TiDG, MaxCalix, and modifier were sufficient for continuing operation without adding a trim during that time but it is recommended that an addition of TiDG, modifier and Isopar™L should be made in the next few months. This monthly sample’s rheology, as determined by Hydrogen Nuclear Magnetic Resonance (H-NMR), is consistent with the rheology of the standard NGS solvent made in the lab (Scratch solvent 5/14/2014). No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). In addition, up to 16.7 micrograms of mercury per gram of solvent (or 14 μg/mL) was detected in this sample. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

36 MATERIALS SCIENCE↗

Solvent Hold Tank Sample Results for MCU-15-556-557-558: March 2015 Monthly Sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-556, MCU-15-557, and MCU-15-558), pulled on 03/16/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-556-557-558 indicated a low concentration (~ 78 % of nominal) of the suppressor (TiDG) and concentrations of the extractant (MaxCalix), and of the modifier (CS-7SB) in the solvent that were slightly lower than nominal. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in February 2015. Based on the current monthly sample, the levels of TiDG, MaxCalix, and modifier are sufficient for continuing operation without adding a trim at this time. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). However, the p-nut vials that delivered the samples contained small (1 mm) droplets of oxidized modifier and amides (as detected by the FTIR analysis). In addition, up to 21 microgram of mercury per gram of solvent (or 17.4 µg/mL) was detected in this sample. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Meteorite Sample Section Repair at NASA Johnson Space Center

Introduction: Meteorite thin and thick sections are routinely shipped from NASA Johnson Space Center to fulfill sample allocation requests from principle investigators around the world. Sections are also re-turned to JSC when researchers are finished studying them since, in most cases, they can be reused for other studies. The sections are very fragile unfortunately, and sometimes return to us needing repairs. The fol-lowing should give you an idea of how we repair sections here in the very lab where they were created. NOTE: Please do not attempt to repair ANSMET meteorite sections that are in your possession. We will perform the repairs for you at NASA JSC if you send the section back to us. Section Delamination: The majority of the meteorite sections that we produce here are secured to the glass slide using a high quality, two-part epoxy. Occasionally, we are asked to use superglue if the researcher wishes to dismount the section from the slide. Both epoxy and superglue are excellent adhesives, but they both tend to embrittle with time which results in delamination from the slide. Exposure to vacuum can also degrade the adhesion between the sample section and the glass slide. Repeated handling of the slide edges can accelerate delamination and, as a preventive measure, the outer 1-2 mm of epoxy is trimmed from newly created sections at JSC. If conductive tapes (copper, carbon, etc.) are used on the section during analysis, great care must be taken in removing the tape so that the epoxy is not pulled up with it. If in doubt, the tape can be left on the section when it is returned to JSC. Before we perform any repairs to sample sections, carbon, gold, or other coatings are removed. We accomplish this using a slurry of 0.05 micron alumina and 190 proof ethyl alcohol applied to a felt polishing pad fitted to a rotating lap wheel. Coatings are re-moved in this manner from all sections that are re-turned to JSC. The extent of the delamination determines how we proceed with the section repair. If the meteorite sample area of the section is not disturbed, then we carefully remove the delaminated epoxy. This is done using a binocular microscope with a 6X zoom, cut-proof gloves, and a very sharp, single edged razor blade. We cut the delaminated epoxy with the blade angled away from the sample area and using very light pressure. The trimmed section is then cleaned in an ultrasonic bath of 200 proof ethyl alcohol for no more than 10 seconds and carefully dried using a lint-free clean room wipe. The section is then placed into a lab oven at 110o F in preparation for epoxy. We mix the resin and hardener components of the low viscosity epoxy and very small amounts are applied to the cut edges of the section using a needle probe and the binocular microscope. Warming the epoxy helps secure the existing section by filling any voids between the glass slide and the section. After the new epoxy cures, we give the section a light polish on a lap wheel fitted with cotton polishing paper that is charged with 1 micron diamond paste. If the section has delaminated to the point of sample area being lifted from the glass, then it may be irreparable. We employ the above technique along with clamping the section in a Teflon pad arrangement in order to flatten the sample while the epoxy cures. Otherwise, the sample will tend to curl. This works to some degree, but once the sample area curls, it seldom re-turns to the original flatness without cracking or bending. Canada Balsam and Crystalbond: We repair damaged sections that had originally been prepared using Canada Balsam or Crystalbond adhesives through the gradual application of heat. We take great care with these samples since these bonding materials tend to get brittle with age. The section is heated in gradual steps (40-50o F per hour) to the melting point of the adhesive. We repair the sample while the adhesive is fluid and then the section is cooled in the same gradual manner in which it was heated. Slide Cracks and Breaks: Accidents happen. Especially with something as small and fragile as a thin/thick section. We all know someone who has driven a microscope objective into a section. As bad as the damage may look, the section can be repaired in most instances. NOTE: Please do not try to tape or glue section pieces back together prior to returning the dam-aged section. This practice usually renders the section irreparable. If the glass slide is cracked but the section is still in one piece, we repair it by infilling the crack with the low viscosity epoxy mentioned earlier. If the slide is in pieces, we can reassemble it with epoxy on a new backer slide. This is a tricky task as the pieces need to be in the correct plane with respect to each other, especially if the sample area is split among several pieces.

Meteorite↗

Multihierarchy Gaussian Process Models for Probabilistic Aerodynamic Databases using Uncertain Nominal and Off-Nominal Configuration Data

Probabilistic aerodynamic databases are a crucial component of the development lifecycle for aerospace vehicles. A key challenge when building aerodynamic databases is that most data used to construct them represent various simplifications of the real flight vehicle. For example, wind tunnel models often simplify the vehicle geometry and surface roughness characteristics, while CFD computations often make simplifications to the physics being modeled, such as fully laminar or turbulent calculations. Multifidelity data fusion models rely on a user being able to define a hierarchy of fidelity levels anchored to some "truth" data. This approach is unsatisfactory when no data can be considered to accurately reflect real flight conditions. In this work, we provide an alternative approach by presenting a consistent mathematical framework for building probabilistic aerodynamic databases in the form of a conditional probability distribution described by an ensemble of multifidelity Gaussian Processes. Instead of relying on a single hierarchy of data fidelity levels, the presented framework identifies a "nominal" configuration and potential corrections to the nominal which represent specific physical phenomena not represented in the nominal data. The nominal and correction functions themselves are constructed as multifidelity Gaussian Processes and linearly combined to form an ensemble model which fuses the uncertainties associated nominal and correction models. Results obtained using the proposed framework on a simplified Orion Crew Module wind tunnel dataset demonstrate the predictive capability of the multihierarchy framework. We further demonstrate the benefits of such a probabilistic aerodynamic database approach through function sampling and computing the conditional distributions of derived quantities, such as the trim angle of attack and aerodynamic coefficients at trim.

Gaussian Processes↗

Design, implementation and flight testing of PIF autopilots for general aviation aircraft

The designs of Proportional-Integrated-Filter (PIF) auto-pilots for a General Aviation (NAVION) aircraft are presented. The PIF autopilot uses the sampled-data regulator and command generator tracking to determine roll select, pitch select, heading select, altitude select and localizer/glideslope capture and hold autopilot modes. The PIF control law uses typical General Aviation sensors for state feedback, command error integration for command tracking, digital complementary filtering and analog prefiltering for sensor noise suppression, a control filter for computation delay accommodation and the incremental form to eliminate trim values in implementation. Theoretical developments described in detail, were needed to combine the sampled-data regulator with command generator tracking for use as a digital flight control system. The digital PIF autopilots are evaluated using closed-loop eigenvalues and linear simulations. The implementation of the PIF autopilots in a digital flight computer using a high order language (FORTRAN) is briefly described. The successful flight test results for each PIF autopilot mode is presented.

Broussard, J. R.↗

SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 AND MCU-11-319

Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 and MCU-11-319 are reported. The results show that the solvent at MCU does not require an Isopar{reg_sign} L addition, but it will require addition of trioctylamine. Cesium mass transfer testing with the solvent matches expected extraction behavior but shows a slightly lower stripping efficiency than seen in the original process demonstration for Macrobatch 3. The entrained aqueous solution indicates the scrub wash is significantly out of specification. As a result, the facility replaced the scrub wash. Unlike the previous solvent sample results, these analyses indicate that the solvent does not require minor Isopar{reg_sign} L trimming at this time. However, addition of TOA is warranted. These findings indicate that the new protocols for solvent monitoring and control are yielding favorable results. Nevertheless, the deviation in the TOA concentration since the last analysis indicates continued periodic (i.e., quarterly) monitoring is recommended. The {sup 137}Cs mass transfer results from the solvent sample testing show possible evidence of slightly reduced stripping efficiency. An evaluation (using a model) of expected system performance for MCU using the measured distribution values predicts an {approx}50% decline in DFs given the ESS test results. The customer should consider pulling a SHT sample for reanalysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The rapid-tome, a 3D-printed microtome, and an updated hand-sectioning method for high-quality plant sectioning

Abstract Background Microscopic analysis of plant anatomy is a common procedure in biology to study structure and function that requires high-quality sections for accurate measurements. Hand sectioning of specimens is typically limited to moderately soft tissue while harder samples prohibit sectioning by hand and/or result in inconsistent thicknesses. Results Here we present both a clearly described hand-sectioning method and a novel microtome design that together provide the means to section a variety of plant sample types. The described hand-sectioning method for herbaceous stems works well for softer subjects but is less suitable for samples with secondary growth (e.g., wood production). Instead, the “Rapid-Tome” is a novel tool for sectioning both soft and tougher high-aspect-ratio samples, such as stems and roots, with excellent sample control. The Rapid-Tome can be 3D-printed in approximately 18 h on a mid-quality printer common at university maker spaces. After printing and trimming, Rapid-Tome assembly takes a few minutes with five metal parts common at hardware stores. Users sectioned a variety of plant samples including the hollow internodes of switchgrass ( Panicum virgatum ), fibrous switchgrass roots containing aerenchyma, and woody branches of eastern red cedar ( Juniperus virginiana ) and American sycamore ( Platanus occidentalis ). A comparative analyses with Rapid-Tome-produced sections readily revealed a significant difference in seasonal growth of sycamore xylem vessel area in spring (49%) vs. summer (23%). Additionally, high school students with no prior experience produced sections with the Rapid-Tome adequate for comparative analyses of various plant samples in less than an hour. Conclusions The described hand-sectioning method is suitable for softer tissues, including hollow-stemmed grasses and similar samples. In addition, the Rapid-Tome provides capacity to safely produce high-quality sections of tougher plant materials at a fraction of the cost of traditional microtomes combined with excellent sample control. The Rapid-Tome features rapid sectioning, sample advancement, blade changes, and sample changes; it is highly portable and can be used easily with minimal training making production of thin sections accessible for classroom and outreach use, in addition to research.

3D-printing↗

Solvent Hold Tank Sample Results for MCU-14-135/136 and MCU-14-214/215/216: February and March 2014 Monthly Samples

SRNL received two sets of SHT samples (MCU-14-135-136 in February 2014 and MCU-14-214-216 in March 2014) for analysis. The samples were analyzed for composition. As with the previous solvent sample results, these analyses indicate that the solvent does not require Isopar ® L trimming at this time. However, the addition of TiDG (suppressor) to the blended solvent is recommended. Evidence of possible (slight) isomerization of the solvent, probably Isopar ® L or TiDG degradation products, was observed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-14-259/260/261 AND MCU-14-315/316/317: APRIL AND MAY 2014 MONTHLY SAMPLES

SRNL received two sets of SHT samples (MCU-14-259/260/261 in April 2014 and MCU-14- 315/316/317 in May 2014) for analysis. The samples were analyzed for composition. Both samples have similar chemical composition. As with the previous solvent sample results, these analyses indicate that the solvent does not require Isopar® L trimming at this time. Since an addition of TiDG and MaxCalix to the SHT was added in early July 2014, the solvent does not require TiDG addition at this time. The current TiDG level (1.5 mM) is above the minimum recommended operating level of 1 mM.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results For MCU-15-750-751-752-: June Monthly Sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-750, MCU-15-751, and MCU-15-752), pulled on 06/22/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-750-751-752 indicated a low concentration (~ 49 % of nominal) of the suppressor (TiDG) and slightly lower than nominal concentrations of the extractant (MaxCalix), and of the modifier (Cs-7SB) in the solvent. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in February 2015. Based on the current monthly sample, the levels of TiDG, MaxCalix, and modifier are sufficient for continuing operation without adding a trim at this time but it is recommended that an addition of TiDG, modifier and Isopar™L should be made in the near future. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). In addition, up to 13.9 micrograms of mercury per gram of solvent (or 11.5 µg/mL) was detected in this sample. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent hold tank sample results for MCU-16-1363-1365. November 2016 monthly sample

Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1363-1364-1365), pulled on 11/15/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1363-1364-1365 indicated the Isopar™L concentration is at its nominal level (100%). The extractant (MaxCalix) and the modifier (CS- 7SB) are 8% and 2 % below their nominal concentrations. The suppressor (TiDG) is 7% below its nominal concentration. This analysis confirms the trim and Isopar™ additions to the solvent in November. This analysis also indicates the solvent did not require further additions. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Grid generation on trimmed Bezier and NURBS quilted surfaces

This paper presents some recently added capabilities to RAGGS, Rockwell Automated Grid Generation System. Included are the trimmed surface handling and display capability and structures and unstructured grid generation on trimmed Bezier and NURBS (non-uniform rational B-spline surfaces) quilted surfaces. Samples are given to demonstrate the new capabilities.

Woan, Chung-Jin↗

Trimming and Decontamination of Metagenomic Data can Significantly Impact Assembly and Binning Metrics, Phylogenomic and Functional Analysis

Background: Investigators using metagenomic sequencing to study microbiomes often trim and decontaminate reads without knowing their effect on downstream analyses. Objective: This study was designed to evaluate the impacts JGI trimming and decontamination procedures have on assembly and binning metrics, placement of MAGs into species trees, and functional profiles of MAGs extracted from complex rhizosphere metagenomes, as well as how more aggressive trimming impacts these binning metrics. Methods: Twenty-three Miscanthus x giganteus rhizosphere metagenomes were subjected to different combinations and thresholds of force, kmer, and quality trimming and decontamination using BBDuk. Reads were assembled and binned in KBase. Phylogenomic and statistical analyses were applied to evaluate the effects of trimming and decontamination on downstream analyses. Results: We found that JGI trimmed and decontaminated reads had significant impacts on assembly and binning metrics compared to raw reads, including significantly higher total contig counts, more contigs greater than 10k bp in length, and larger total lengths of raw assemblies compared to QC assemblies, and 2.0% lower average contamination of QC MAGs compared to raw MAGs. We also found that differences in the placement of MAGs in species trees increased with decreasing completeness and contamination thresholds. Furthermore, aggressive trimming (Q20) was found to significantly reduce MAG counts. Conclusion: Trimming and decontamination of metagenomics reads prior to assembly can change an investigator’s answer to the questions, “Who is there and what are they doing?” However, mild trimming and decontamination of metagenomic reads with high-quality scores are recommended for removing sample processing and sequencing artifacts.

Whitham, Jason M.↗

Solvent hold tank sample results for MCU-16-1488-1493 (December 2016), MCU-17-86-88 (January 2017), and MCU-17-119-121 (February 2017): Quarterly Report

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-16-1488-1493 (December 2016), MCU-17-86-88 (January 2017), and MCU-17-119-121 (February 2017) are reported. Analyses indicate that the modifier (CS-7SB) and the extractant (MaxCalix) concentrations are at their nominal recommended levels (169,000 mg/L and 46,300 mg/L respectively). The suppressor (TiDG) level has decreased to a steady state level of 673 mg/L well above the minimum recommended level (479 mg/L). This analysis confirms the Isopar™ addition to the solvent in January 18, 2017. This analysis also indicates the solvent did not require further additions. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). Another impurity observed in the samples was mercury. Up to 38 ± 8 micrograms of mercury per mL of solvent was detected in these samples (the average of the CV-AA and XRF methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 8 and 9 (Tank 49H) or mixing of previously undisturbed areas of high mercury concentration in Tank 49H. The gamma level (0.21E5 dpm/mL) measured in the February SHT sample was one order of magnitude lower than the gamma levels observed in the December and January SHT samples. The February gamma level is consistent with the solvent being idle (since January 10, 2017). The gamma levels observed in the December and January SHT samples were consistent with previous monthly measurements where the process operated normally. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and flight testing of a digital optimal control general aviation autopilot

This paper presents the designs of Proportional-Integral-Filter (PIF) autopilots for a General Aviation (NAVION) aircraft. The PIF autopilots use modern control theory to determine heading select and altitude select and hold autopilot modes. The PIF control law uses typical General Aviation sensors for state feedback; command error integration for command tracking; digital complimentary filtering and analog prefiltering for sensor noise suppression; a control filter for computation delay accommodation; and the incremental form to eliminate trim values in implementation. Theoretical developments for the control law are described which combine the sampled-data regulator with command generator tracking for use as a digital flight control system. The digital PIF autopilots are evaluated using closed-loop eigenvalues and simulations. Successful flight test results for the PIF autopilots are presented for different turbulence conditions and quadratic weights.

Broussard, J. R.↗

Using a Blender to Assess the Microbial Density of Encapsulated Organisms

There are specific NASA requirements for source-specific encapsulated microbial density for encapsulated organisms in non-metallic materials. Projects such as the Mars Science Laboratory (MSL) that use large volumes of non-metallic materials of planetary protection concern pose a challenge to their bioburden budget. An optimized and adapted destructive hardware technology employing a commercial blender was developed to assess the embedded bioburden of thermal paint for the MSL project. The main objective of this optimization was to blend the painted foil pieces in the smallest sizes possible without excessive heating. The small size increased the surface area of the paint and enabled the release of the maximum number of encapsulated microbes. During a trial run, a piece of foil was placed into a blender for 10 minutes. The outside of the blender was very hot to the touch. Thus, the grinding was reduced to five 2-minute periods with 2-minute cooling periods between cycles. However, almost 20% of the foil fraction was larger (>2 mm). Thus, the largest fractions were then put into the blender and reground, resulting in a 71% increase in particles less than 1 mm in size, and a 76% decrease in particles greater than 2 mm in size. Because a repeatable process had been developed, a painted sample was processed with over 80% of the particles being <2 mm. It was not perceived that the properties (i.e. weight and rubber-like nature) of the painted/foil pieces would allow for a finer size distribution. With these constraints, each section would be ground for a total of 10 minutes with five cycles of a 2-minute pulse followed by a 2-minute pause. It was observed on several occasions that a larger blade affected the recovery of seeded spores by approximately half an order of magnitude. In the standard approach, each piece of painted foil was aseptically removed from the bag and placed onto a sterile tray where they were sized, cut, and cleaned. Each section was then weighed and placed into a sterile Waring Laboratory Blender. Samples were processed on low speed. The ground-up samples were then transferred to a 500-mL bottle using a sterile 1-in. (.2.5-cm) trim brush. To each of the bottles sterile planetary protection rinse solution was added and a modified NASA Standard Assay (NASA HBK 6022) was performed. Both vegetative and spore plates were analyzed.

Benardini, James N.↗

Simplifying Satellite and Ground Data Validation with Level-2 Subsetting

We demonstrate that scientists can simplify their satellite data validation workflow with the use of NASA Godddard Earth Sciences Data and Information Services Center (GES DISC) subsetting services. We perform a sample validation of Aura ozone products collocated with ground-based ozone measurements using subsetting services to trim satellite data to only the relevant user-defined variables and spatio-temporal region. Because the subsetting service automatically returns only relevant data granules that adhere to a set of user-defined coincidence criteria, user workload is greatly reduced. Moreover, the resultant data files are substantially smaller than full data granules due to the subsetting service further culling the data to the relevant geospatio-temporal coincidence criteria, user-defined variables, and user-defined dimensions of variables. This decreases data download throughput and file storage requirements. The validation presented here quantifies the time and file size savings that can be achieved by utilizing subsetting services within the satellite data validation workflow.

Johnson, James↗

Solvent hold tank sample results for MCU-15-815-816-817-818-819-820 November monthly sample

Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-815-816-817-818-819-820), pulled on 11/29/2015 for analysis. The samples were inspected, combined, and analyzed for composition. Chemical analysis of the composite sample MCU-15-815-816-817-818-819-820 indicated the TiDG, Isopar™L, and MaxCalix are at nominal levels. The modifier concentration is 3% below its nominal concentration. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent on November 28, 2015. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, up to 12.5 ± 3 micrograms of mercury per gram of solvent (or 10.4 μg/mL) was detected in this sample. The solids residues found at the bottom of the p-nut vial from sample MCU-15-815 were determined to be left-over pipe residues that were flushed into the sample and they were found to have no impact on the solvent purity or on the chemical and physical properties of the solvent. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗