Trimmed sampling algorithm for the noisy generalized eigenvalue problem
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The LAB4D is a new application-specific integrated circuit (ASIC) of the Large Analog Bandwidth Recorder and Digitizer with Ordered Readout (LABRADOR) family, for use in direct wideband radio frequency digitization such as is used in ultrahigh energy neutrino and cosmic ray astrophysics. The LAB4D is a single channel switched-capacitor array (SCA) 12-bit sampler with integrated analog-to-digital converters (ADC), developed in the TSMC 0.25um process. The LAB4D, operating at 3.2GSa/s, contains 4096 total samples arranged in 32 windows, for a total record length of 1280ns. The 3dB bandwidth is approximately 1.3GHz, with a directly-coupled 50ohm input. This represents a factor of 16 increase in the sample depth and an increase in analog bandwidth and sampling depth in comparison to the previous generation LAB3 digitizer. Individually addressable windows allow for sampling and digitization to occur simultaneously, leading to nearly deadtime-free readout for kHz readout rates. All biases and current references are generated via internal digital-to-analog converters (DACs), resulting in a stand-alone digitizer with no additional support circuitry. In addition, the LAB4D contains sample cell timebase trimming capabilities, reducing the intrinsic sample-to-sample time variance to less than 5ps; an improvement of about 80%. This allows the LAB4D to be used in precision timing applications with minimal post-hoc calibration.
Explore the source record for details and available documents.
ABSTRACT Gamma-ray bursts (GRBs), can be employed as standardized candles, extending the distance ladder beyond Type Ia supernovae (SNe Ia, z = 2.26). We standardize GRBs using the three-dimensional (3D) Fundamental Plane relation (the Dainotti relation) among the rest-frame end time of the X-ray plateau emission, its corresponding luminosity, and the peak prompt luminosity. Combining SNe Ia and GRBs, we constrain ΩM = 0.299 ± 0.009 assuming a flat Λ cold dark matter (ΛCDM) cosmology with and without correcting GRBs for selection biases and redshift evolution. Using a 3D optical Dainotti correlation, we find this sample is as efficacious in the determination of ΩM as the X-ray sample. We trimmed our GRB samples to achieve tighter planes to simulate additional GRBs. We determined how many GRBs are needed as stand-alone probes to achieve a comparable precision on ΩM to the one obtained by SNe Ia only. We reach the same error measurements derived using SNe Ia in 2011 and 2014 with 142 and 284 simulated optical GRBs, respectively, considering the error bars on the variables halved. These error limits will be reached in 2038 and in 2047, respectively. Using a doubled sample (obtained by future machine learning approaches allowing a light-curve reconstruction and the estimates of GRB redshifts when z is unknown) compared to the current sample, with error bars halved we will reach the same precision as SNe Ia in 2011 and 2014, now and in 2026, respectively. If we consider the current SNe precision, this will be reached with 390 optical GRBs by 2054.
This research work focuses on a specific defect which occurs during cold rolling of steel strips: edge-serration. Investigations on the industrial processes have led to the conclusion that this defect is the result of the edge-trimming and cold rolling sequences. The aim of this research work is to analyze the effect of the cutting process and the cold rolling on cracks occurrence, especially on strip edges.This study is performed using an experimental testing stand called Upsetting Rolling Test (URT). It allows to reproduce cold rolling contact parameters such as forward slip, reduction ratio and friction coefficients. Specimens sampled near trimmed industrial strip edges are deformed using the URT stand. Two sets of specimens with different stress states, obtained by annealing, are submitted to two reduction passes with extreme forward slips.Scanning electron microscopy observations added to 3D optical surface profiler topographies show that on one hand, forward slip has a major effect on cracks opening. On the other hand, cracks opening decreases according to high roll strip speed gradient. Concerning the heat-treated specimens, no crack appeared after all reduction passes, showing a large influence of the cutting process and consequently of the local stress state in the vicinity of the burnish and fracture regions.
The current mission at H-Canyon involves the dissolution of an Alternate Feedstocks 2 (AFS-2) inventory that contains plutonium metal. Once dissolved, HB-Line is tasked with purifying the plutonium solution via anion exchange, precipitating the Pu as oxalate, and calcining to form plutonium oxide (PuO 2 ). The PuO 2 will provide feed product for the Mixed Oxide (MOX) Fuel Fabrication Facility, and the anion exchange raffinate will be transferred to H-Canyon. The results presented in this report document the potential success of the RE resin column extraction application on highly concentrated Pu samples to meet MOX feed product specifications. The original 'Hearts Cut' sample required a 10000x dilution to limit instrument drift on the ICP-MS method. The instrument dilution factors improved to 125x and 250x for the sample raffinate and sample eluent, respectively. As noted in the introduction, the significantly lower dilutions help to drop the total MRL for the analyte. Although the spike recoveries were half of expected in the eluent for several key elements, they were between 94-98% after Nd tracer correction. It is seen that the lower ICD limit requirements for the rare earths are attainable because of less dilution. Especially important is the extremely low Ga limit at 0.12 μg/g Pu; an ICP-MS method is now available to accomplish this task on the sample raffinate. While B and V meet the column A limits, further development is needed to meet the column B limits. Even though V remained on the RE resin column, an analysis method is ready for investigation on the ICP-MS, but it does not mean that V cannot be measured on the ICP-ES at a low dilution to meet the column B limits. Furthermore, this column method can be applicable for ICP-ES as shown in Table 3-2, in that it trims the sample of Pu, decreasing and sometimes eliminating Pu spectral interferences.
SRNL received two sets of SHT samples (MCU-14-667-672, pulled 8/27/2014 and MCU-14-846-847, pulled on 9/22/2014) for analysis. The samples were analyzed for composition. It is recommended that the solvent receives Isopar® L and TiDG trimming at this time. Analysis of sample MCU-14-846-847 indicates the solvent has evaporated Isopar®L and has lost TiDG to a level below the recommended minimum 1 mM level. Since the addition of MaxCalix to the SHT in early July 2014, the MaxCalix concentration in the solvent has reached nominal values. The laboratory will continue to monitor the quality of the solvent in particular for any new impurity or degradation of the solvent components.
Data were developed to compare the extent of structural damage associated with high temperature exposure to an air leak. Two materials, NBG-18 graphite and unpurified PCEA graphite have been tested as of this report. The scope was limited to isothermal oxidation at a single temperature, 750°C. Ambient post-oxidation compression strength testing was performed for three levels of burn off (1%, 5%, and 10% mass loss) for two leak scenarios: 100% air and 10% air in helium. Temperature, gas flow, and dynamic mass loss oxidation conditions were monitored and recorded for each sample. The oxidation period was controlled with flow of inert gas during the thermal ramp and upon cool down with a constant 10 liter per minute flow maintained throughout furnace operation. Compressive strengths of parallel un-oxidized samples were tested to assess the relative mass loss effects. In addition to baseline samples matching the un-oxidized dimensions of the oxidized samples, two sets of mechanically reduced samples were prepared. One set was trimmed to achieve the desired mass loss by removing an effectively uniform depth from the geometric surface of the sample. The other set was cored to produce a full penetration axial hole down the center of each sample.
A trend summary of three sets of Solvent Hold Tank (SHT) monthly samples (MCU-19-2-3-4, MCU-19-83-84-85, MCU-19-208-209-210); and a set from a special trim (MCU-19-138-139-140) are reported. Most of the conclusions are based on the March SHT sample (MCU-18-208-209-210). Analyses of the March SHT sample (MCU-19-208-209-210) indicated that the Modifier (Cs-7SB) and the Extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,900 mg/L, respectively) by 3% and 6%, respectively. The Suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has increased since the January 2019 measurement to 1141 mg/L, which is above the minimum recommended concentration (479 mg/L). These new concentrations are consistent with the concentrations observed when MCU was fully operational in 2016. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected presence of phthalates at a few ppm. The impurity concentration was highest in the January sample and consistently detected in the February and March samples (but always registered as a few ppm or less). Another impurity observed in the samples was mercury. Based on the March SHT sample, up to 25 ± 5 micrograms of mercury per mL of solvent was detected (as the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three-monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10. The gamma concentration (~2.55E5 dpm/mL) measured in the March 2019 SHT samples was consistent with previous values observed when MCU was operating continuously (for example, between December 2016 and January 2017). Statistical analysis of the different analytical methods detected a bias (a statistical difference at 5% level) between the FT-HNMR and HPLC methods when measuring the MaxCalix and Modifier concentration; the FT-HNMR gave a higher concentration possibly due to peak overlapping in the measured data. A bias was also detected when measuring total mercury by the DMA method versus the XRF method with the XRF method reported higher mercury concentrations. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.
A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-18-301-302-303, MCU-18- 357-359-360 and MCU-18-402-410 are reported. Most of the conclusions are based on the September SHT sample (MCU-18-402-410). Analyses of the September SHT sample (MCU-18-402-410) indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 5% and 8% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 241 mg/L, well below the minimum recommended concentration (479 mg/L). The apparent “downwards” trends observed in the TiDG, MaxCalix, and Modifier measurements are consistent with the startup (or Proficiency Runs) of MCU on May 22, 2018; new levels are consistent with the concentrations observed when MCU was fully operational in 2016. This analysis confirms the Isopar™ L addition to the solvent on July 2 and August 9, 2018. This analysis also indicates the solvent did require a trim addition. Based on the current monthly sample, the concentrations of Isopar™ L, MaxCalix, and Modifier are sufficient for continuing operation but are expected to decrease with time. The TiDG concentration was below its recommended level. Periodic characterization and trimming additions to the solvent are recommended. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected a low concentration of sec-butyl phenol (SBP) at levels of a few ppm. The impurity concentration was highest in the July sample and consistently detected in the August and September samples (but always a few ppm or less). The source of this impurity is due to the degradation of the Modifier. Another impurity observed in the samples was mercury. Based on the September SHT sample, up to 17 ± 3 micrograms of mercury per mL of solvent was detected (the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10 (SB 10 was recently added to Tank 49H in March 2017). The gamma concentration (~2.3E5 dpm/mL) measured in the September SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) and it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.
The Japanese space agency's (JAXA) Hayabusa mission returned the first particulate samples (typically <100micron) from the surface of an asteroid (25143 Itokawa). These precious samples provide important insights into early Solar System processes, but their sizes pose tremendous challenges to coordinated analysis using a variety of nano- and micro-beam techniques. The ability to glean maximal information from individual particles has become increasingly important and depends critically on sample preparation. We developed a hybrid technique combining traditional ultramicrotomy with focused ion beam (FIB) techniques, allowing for more thorough in situ investigations of grain surfaces and interiors. Using this method, we increase the number of FIB-prepared sections that can be recovered from a particle with dimensions on the order of tens of microns. These sections can be subsequently analyzed using a variety of analytical techniques. Particle RA-QD02-0211 is a approx. 40×40×20 micron particle from Itokawa containing olivine and Fe sulfides. It was embedded in low viscosity epoxy and partly sectioned to a depth of approx 10 micron; sections are placed on Cu grids with thin amorphous films for transmission electron microscope (TEM) analyses. With the sample surface partly exposed, the epoxy bullet is trimmed to a height of approx. 5mm to accommodate the allowable dimensions for FIB work (FEI Quanta 600 3D dual beam FIB-SEM). Using a diamond trim knife, the epoxy surrounding the grain is removed on 3 sides (to within a few microns of the grain); the depth of material removed extends well below the bottom of the particle. The sample is attached to an SEM pin mount, the epoxy coated with conductive paint, and the entire assembly coated with approx. 40nm of carbon to eliminate sample charging during FIB work. A protective carbon cap is placed according to the plan for the 15 FIB sections. The central 'spine' of the cap runs perpendicular to the front of the sample, and the 'ribs' protruding from either side run parallel. Each rib indicates the location of a planned FIB section, and the spine contains the final two planned sections. We use a cap with a 4 micron-wide spine and 2micron-wide ribs that have ≳3.5 micron of space between them (narrower cuts result in too much re-deposition of material inside the trenches). Using a 30kV, 3nA ion-beam we expose the front surface of the grain and commence milling trenches between sections. Rather than using the typical C-cut to prepare the sample for lift-out, an L-cut is used instead, leaving the sample connected by an interior tab. tab. Sections are lifted out, attached to TEM grids and thinned to electron transparency. TEM analyses show that our hybrid technique preserves both interior and edge features, including surface modifications from exposure to the space environment, such as damaged rims that form in response to solar wind implantation effects and adhering grains. In addition, the FIB sections provide larger areas that are free of fractures and chatter effects in comparison to the microtome thin sections, thus enabling more accurate measurements of solar flare particle track densities that are used to determine the surface exposure age of the particles.
One of the more challenging aspects of the trajectory design for the OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer) mission at asteroid Bennu was maneuvering while in orbit. The orbital dynamics were highly perturbed by various sources, most notably solar radiation pressure, which degraded accuracy of long term predictions of the spacecraft’s location in orbit. Generally, the Navigation team had to solve three separate issues: correcting a perturbed orbit, changing to a different orbit, or phasing the or bitto place the spacecraft at a specific location at a specific time. The team composed a common framework using up to two maneuvers that could solve all of these problems using an identical schedule that allowed for consistent planning long before the final trajectory could be designed. This orbit trim strategy was successfully used for the first time in the Orbital B phase of the mission to maximize the duration of usable observing geometry in a time-variable orbit with strict operational limits. It was used an additional 3 times throughout the mission to adjust and/or change the orbit, most notably altering the orbit in the weeks prior to the successful Touch-And-Go (TAG)sample collection attempt. This same strategy was used to phase the orbit a total 10 times in preparation for each of the science sorties over potential sample sites, the TAG Rehearsals, and TAG. The trim strategy was demonstrated to be robust and performed exceptionally well in all aspects, which proved critical to a successful sample collection.
Savannah River National Laboratory (SRNL) analyzed solvent samples from the Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-1403, MCU-13-1404, MCU-13-1405, MCU-13-1406, MCU-13-1407, and MCU-13-1408 received on September 17, 2013 are reported. This sample was taken after the addition of the Next Generation Solvent (NGS) cocktail to produce a NGS-MCU blended solvent. The results show that the solvent contains a slight excess of Isopar ® L and a deficit concentration of modifier and TiDG when compared to the target composition. Addition of TiDG trim is recommended. SRNL also analyzed the SHT sample for 137 Cs content and determined the measured value is within tolerance and that the value has returned to levels observed in 2011. In contrast to what was observed in the heel prior to adding the NGS cocktail, no organic impurities were detected in these solvent samples.
The Savannah River National Lab (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-661, MCU-15-662, and MCU-15-663 pulled on April 2, 2015) for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-661-662-663 indicated a low concentration (~ 63% of nominal) of the suppressor (TiDG) and a slightly below the nominal concentration (~ 10% below nominal) of the extractant (MaxCalix). The modifier (CS-7SB) level was also 10% below its nominal value while the Isopar™ L level was slightly above its nominal value. This analysis confirms the addition of Isopar™L to the solvent on March 6, 2015. Despite that the values are below target component levels, the current levels of TiDG, CS-7SB and MaxCalix are sufficient for continuing operation without adding a trim at this time until the next monthly sample. No impurities above the 1000 ppm level were found in this solvent. However, the sample was found to contain approximately 18.4 ug/g solvent mercury. The gamma level increased to 8 E5 dpm/mL solvent and it represents an order of magnitude increase relative to previous solvent samples. The increase means less cesium is being stripped from the solvent. Further analysis is needed to determine if the recent spike in the gamma measurement is due to external factors such as algae or other material that may impede stripping. The laboratory will continue to monitor the quality of the solvent in particular for any new impurity or degradation of the solvent components.
EDGE bioinformatics was developed to help biologists process Next Generation Sequencing data (in the form of raw FASTQ files), even if they have little to no bioinformatics expertise. EDGE is a highly integrated and interactive web-based platform that is capable of running many of the standard analyses that biologists require for viral, bacterial/archaeal, and metagenomic samples. EDGE provides the following analytical workflows: quality trimming and host removal, assembly and annotation, comparisons against known references, taxonomy classification of reads and contigs, whole genome SNP-based phylogenetic analysis, and PCR analysis. EDGE provides an intuitive web-based interface for user input, allows users to visualize and interact with selected results (e.g. JBrowse genome browser), and generates a final detailed PDF report. Results in the form of tables, text files, graphic files, and PDFs can be downloaded. A user management system allows tracking of an individual’s EDGE runs, along with the ability to share, post publicly, delete, or archive their results.
EDGE bioinformatics was developed to help biologists process Next Generation Sequencing data (in the form of raw FASTQ files), even if they have little to no bioinformatics expertise. EDGE is a highly integrated and interactive web-based platform that is capable of running many of the standard analyses that biologists require for viral, bacterial/archaeal, and metagenomic samples. EDGE provides the following analytical workflows: quality trimming and host removal, assembly and annotation, comparisons against known references, taxonomy classification of reads and contigs, whole genome SNP-based phylogenetic analysis, and PCR analysis. EDGE provides an intuitive web-based interface for user input, allows users to visualize and interact with selected results (e.g. JBrowse genome browser), and generates a final detailed PDF report. Results in the form of tables, text files, graphic files, and PDFs can be downloaded. A user management system allows tracking of an individual’s EDGE runs, along with the ability to share, post publicly, delete, or archive their results.
Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-189, MCU-13-190, and MCU-13-191 received on September 4, 2013 are reported. The results show that the solvent (remaining heel in the SHT tank) at MCU contains excess Isopar ® L and a deficit concentration of modifier and trioctylamine when compared to the standard MCU solvent. As with the previous solvent sample results, these analyses indicate that the solvent does not require Isopar ® L trimming at this time. Since MCU is switching to NGS, there is no need to add TOA nor modifier. SRNL also analyzed the SHT sample for 137 Cs content and determined the measured value is within tolerance and the value has returned to levels observed in 2011.
This plan provides the technical basis and associated protocols to support Phase 1 final status survey (FSS) data collection and interpretation as part of the West Valley Demonstration Project Phase 1 Decommissioning Plan process. This plan is consistent with the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). The Phase 1 Decommissioning Plan provides the relevant derived concentration guideline levels (DCGLs) for the Phase 1 radionuclides of interest. This plan includes protocols that will be applied to the deep excavations planned for Waste Management Area (WMA) 1 and WMA 2, for surface soils outside the WMA 1 and WMA 2 excavations that do not have contamination impacts at depths greater than one meter, and for areas that are used for Phase 1 contaminated soil lay-down purposes. All excavated and lay-down areas will be classified as MARSSIM Class 1 areas. Surface soils that have not been excavated, are not expected to exceed DCGLs, and do not have contamination impacts at depths greater than one meter will be divided into either Class 1 or Class 2 areas depending on the expected potential for surface soil contamination in those areas. The plan uses gamma scans combined with biased soil samples to address DCGLemc concerns. The plan uses systematic soil sampling combined with area factors to address DCGLw and DCGLemc concerns. The Sign test will be used to statistically evaluate DCGLw compliance. If the results from the characterization sampling and analysis plan (CSAP) data collection indicate that background may be a significant issue for Sign test implementation, the Wilcoxon rank sum (WRS) test will be used instead to demonstrate DCGLw compliance. A reference area will be selected on the basis of CSAP data results if the WRS test becomes a necessity. The WMA 1 excavation footprint includes approximately 476 foundation pilings that will be trimmed and left in place. Piling-specific systematic and biased sampling will be conducted to address concerns that these pilings may have served as preferential flow pathways into the underlying Lavery till. Phase 1 FSS data collection results will be summarized, presented, and interpreted in one or more FSS reports.