Search NASA⌕ Search

SEARCH · Search NASA

Results for “ultrasensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ultra-sensitive transducer advances micro-measurement range

An ultrasensitive piezoelectric transducer, that converts minute mechanical forces into electrical impulses, measures the impact of micrometeoroids against space vehicles. It has uniform sensitivity over the entire target area and a high degree of stability.

Rogallo, V. L.↗

Kinetic inductance measured in a superconducting wire

Ultrasensitive technique to measure kinetic inductance has test specimen included as part of the inductance of a tank circuit of a tunnel diode oscillator. Frequency counter measures shift in frequency of oscillator, caused by changes in inductance. Frequency shift in tank circuit is proportional to change in kinetic inductance

Meservey, R. H.↗

Remote detection of turbulence in clear air.

Various concepts for remote detection of turbulence in the clear air are reviewed. It is concluded that there is at present no technique available for operational use to remotely detect and measure turbulence in the clear air. Several techniques with good potentials for future application currently being studied include a laser Doppler radar method for airborne and ground-based use and an approach utilizing ground-based ultrasensitive microwave Doppler radars.

Mcgowan, W. A.↗

Intensive probing of a clear air convective field by radar and instrumental drone aircraft.

An instrumented drone aircraft was used in conjunction with ultrasensitive radar to study the development of a convective field in the clear air. Radar data are presented which show an initial constant growth rate in the height of the convective field of 3.8 m/min, followed by a short period marked by condensation and rapid growth at a rate in excess of 6.1 m/min. Drone aircraft soundings show general features of a convective field including progressive lifting of the inversion at the top of the convection and a cooling of the air at the top of the field. Calculations of vertical heat flux as a function of time and altitude during the early stages of convection show a linear decrease in heat flux with altitude to near the top of the convective field and a negative heat flux at the top. Evidence is presented which supports previous observations that convective cells overshoot their neutral buoyancy level into a region where they are cool and moist compared to their surroundings. Furthermore, only that portion of the convective cell that has overshot its neutral buoyancy level is generally visible to the radar.

Rowland, J. R.↗

Development of a microbalance suitable for space application

The tapered element oscillating microbalance (TEOM), an ultrasensitive mass measurement device which is suitable for both particulate and vapor deposition measurements is described. The device can be used in contamination measurements, surface reaction studies, particulate monitoring systems or any microweighing activity where either laboratory or field monitoring capability is desired. The active element of the TEOM consists of a tube or reed constructed of a material with high mechanical quality factor and having a special taper. The element is firmly mounted at the wide end while the other end supports a substrate surface which can be composed of virtually any material. The tapered element with the substrate at the free (narrow) end is set into oscillation in a clamped free mode. A feedback system maintains the oscillation whose natural frequency will change in relation to the mass deposited on the substrate.

Patashnick, H.↗

Measurements of Cl-36 in Antarctic meteorites and Antarctic ice using a Van de Graaff accelerator

The paper presents measurements of cosmic-ray produced (Cl-36) in Antarctic meteorites and ice using a Van de Graaff accelerator as an ultrasensitive mass spectrometer. Results from this ion counting technique are used to support a two-stage irradiation model for the Yamato-7301 and Allan Hills-76008 meteorites and to show a long terrestrial age for Allan Hills-77002. Yamato-7304 has a terrestrial age of less than 0.1 m.y., and the (Cl-36) content of the Antarctic ice sample from the Yamato mountain is consistent with levels expected in currently depositing snow implying that the age of the ice cap at this site is less than on (Cl-36) half-life.

Nishiizumi, K.↗

On the trail of Comet G-Z

The International Cometary Explorer (ICE) is to investigate the magnetic and electric fields, plasmas, and particles in the Comet Giacobini-Zinner (G-Z) and to study its interaction with solar wind. The ICE can pass through the comet only once and it will take 90 minutes to cross from one side of the tail to the other. Since the Comet G-Z often changes its orbit due to nongravitational forces changing its direction and velocity, ICE's position needs to be adjusted. The probe is aimed 10,000 km from the nucleus in order to be provided the best passage through the Comet G-Z. The 64-meter dishes of JPL's Deep-Space Network (DSN) will receive data transmitted on two adjacent S-band frequencies at the rate of 1024 bits per second. Also NASA has arranged for the radio telescope at Arecibo to record the transmission. The Japanese 64-meter tracking antenna at Usada, equipped with an ultrasensitive receiver for one ICE frequency, will provide pre-encounter and post-encounter tracking. The ICE data may provide information about the dust tail in the Comet G-Z which could be compared to previous research.

Maran, S. P.↗

Microscopic Gas-Flow Controller

Proposed flow-controlling and -measuring device made by batch solid-state microelectronic-fabrication techniques. Device contains ultrasensitive silicon capacitive pressure transducer, gas-flow channels etched in silicon wafer, and integrated microvalves. Used to control and monitor low gas flows at low pressures.

Wise, Kensall D.↗

Experimental Resonance Enhanced Multiphoton Ionization (REMPI) studies of small molecules

Resonance enhanced multiphoton ionization (REMPI) utilizes tunable dye lasers to ionize an atom or molecule by first preparing an excited state by multiphoton absorption and then ionizing that state before it can decay. This process is highly selective with respect to both the initial and resonant intermediate states of the target, and it can be extremely sensitive. In addition, the products of the REMPI process can be detected as needed by analyzing the resulting electrons, ions, fluorescence, or by additional REMPI. This points to a number of exciting opportunities for both basic and applied science. On the applied side, REMPI has great potential as an ultrasensitive, highly selective detector for trace, reactive, or transient species. On the basic side, REMPI affords an unprecedented means of exploring excited state physics and chemistry at the quantum-state-specific level. An overview of current studies of excited molecular states is given to illustrate the principles and prospects of REMPI.

Dehmer, J. L.↗

Gradiometer accommodation on board a drag-free satellite

Accommodation of the GRADIO instrument, composed of eight three-axis ultrasensitive accelerometers located at the corners of a cubic structure on a Geopotential Research Mission spacecraft is discussed. A two-stage DISCOS configuration with a magnetically suspended inner-stage; and a very fine control of the Earth pointed inner-stage taking into account the GRADIO accelerometer measurements in order to limit the variations of the angular accelerations are required. For diagonal tensor components and an averaging time of 4 sec, the overall goal is 0.1 Eotvos at 160 km altitude.

Touboul, P.↗

Prospects for observations of nucleosynthetic gamma-ray lines and continuum from SN 1987A

Expected flux levels for nucleosynthetic gamma-ray line and continuum emissions from SN 1987A are calculated for several models. The dominant line emission is from freshly synthesized Ni-56 and its decay daughters, and the continuum is from Compton scattering of line photons. For a 15 solar mass Type II model, the light curve for the 0.847 MeV gamma-ray line peaks in September 1988 at 3 x 10 to the -4th photons/sq cm/s. This is detectable only by new, ultrasensitive balloon-borne spectrometers. For models with substantial mass loss from their envelopes, the peak is in early 1988 at about 0.01 photons/sq cm/s, which is detectable at high significance levels by all current instruments. The continuum emission in the 0.05-0.5 MeV band peaks about 100 days before the 0.847 MeV line peak. This Compton precursor is observable at about the same significance level as the lines.

Gehrels, Neil↗

Observed rate of ionization in shaped-charge releases of barium in the ionosphere

Data from 36 Ba shaped-charge releases carried out at an angle of less than 25 deg to the magnetic field, by the technique of Wescott et al. (1972) and Michel (1974), were examined for evidence of a sustained rate of ionization in excess of that attributable to sunlight. In four of the experiments, the time constant for the decay of the neutrals was measured using an ultrasensitive color TV camera and was found to have a value of about 30 sec, consistent with slow (solar) ionization. Although the qualitative appearance of most jets was found to be consistent with a slow process of ionization, some releases produced a thin confined jet that was suggestive of rapid ionization. Two of these jets were analyzed in detail, but no evidence of anomalous ionization was produced. The data obtained in this work agree with the geometrical predictions of the Swift model.

Hallinan, Thomas J.↗

Capacitive Position Sensor For Accelerometer

Capacitive position sensor measures displacement of proof mass in prototype accelerometer described in "Single-Crystal Springs for Accelerometers" (NPO-18795). Sensor is ultrasensitive, miniature device operating at ultra-high frequency and described in more detail in "Ultra-High-Frequency Capacitive Displacement Sensor," (NPO-18675). Advances in design and fabrication of prototype accelerometer also applicable to magnetometers and other sensors in which sensed quantities measured in terms of deflections of small springs.

Vanzandt, Thomas R.↗

Evaluation of HAN-TEAN Stabilizers using Microcalorimetry

HAN-TEAN (hydroxylammonium nitrate - triethanolammonium nitrate - in water) is being considered for various propellant applications. This propellant has advantages in terms of insensitivity to impact and fire, low vapor pressure and environmentally benign reaction products. One office concerns with HAN-TEAN is its stability and shelf-life, especially when contaminated with trace metals. Stabilizer systems, consisting of anti-oxidants and/or chealating agents were investigated for their ability to control the decomposition of HAN-TEAN. Isothermal microcalorimetry, an ultrasensitive heat measurement technique, was used to monitor the decomposition of HANTEAN at near ambient temperatures. Isothermal microcalorimetry measures the heat flow from a reaction vessel into a surrounding heat sink. Microcalorimetry is approximately 1,000 times more sensitive than accelerating rate calorimetry (ARC) or differential scanning calorimetry (DSC) for measuring heat flow. Samples of HAN-TEAN containing the stabilizers were spiked with 50 ppm iron and the heat evolution monitored for a period of at least 30 days. Ten stabilizer combinations were tested and the rates of HAN-TEAN decomposition were lowered by 74 to 95 percent in the presence of iron.

Hornung, Steven D.↗

Microcalorimetric Measurements of Hydrogen Peroxide Stability

Recent interest in propellants with nontoxic reaction products has led to a resurgence of interest in hydrogen peroxide for various propellant applications. Because hydrogen peroxide is sensitive to contaminants and materials interactions, stability and shelf life are issues. A relatively new, ultrasensitive heat measurement technique, isothermal microcalorimetry, is being used at the White Sands Test Facility to monitor the decomposition of hydrogen peroxide at near ambient temperatures. Isothermal microcalorimetry measures the beat flow from a reaction vessel into a surrounding heat sink. In these applications, microcalorimetry is approximately 1,000 times more sensitive than accelerating rate calorimetry or differential scanning calorimetry for measuring thermal events. Experimental procedures have been developed for the microcalorimetric measurement of the ultra-small beat effects caused by incompatible interactions of hydrogen peroxide. The decomposition rates of hydrogen peroxide at the picomole/sec/gram level have been measured showing the effects of stabilizers and peroxide concentration. Typical measurements are carried out at 40 C over a 24-hour period, This paper describes a method for the conversion of the heat flow measurements to chemical reaction rates based on thermochemical considerations. The reaction rates are used in a study of the effects of stabilizer levels on the decomposition of propellant grade hydrogen peroxide.

Davis, Dennis D.↗