Search NASA⌕ Search

SEARCH · Search NASA

Results for “utility bill validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A New Methodology for Calculating The Energy Performance of Manufacturing Facilities

Total energy comparison (TEC), classic energy intensity (CEI), and linear regression models (LRM) are the three most common approaches used to track the energy performance of manufacturing facilities. TEC simply compares the total energy consumption from utility bills. TEC is rarely used because it does not consider the variation of any factors that may affect energy consumption. One step better, CEI considers the variation of production rates by using the ratio of annual total energy consumption over annual total production. However, CEI fundamentally assumes that energy consumption is zero if the production rate is zero. This is almost never true and can cause significant errors. Using linear regression models, LRM considers the impact of multiple variables and, therefore, most accurately tracks energy performance. Unfortunately, because of the lack of either required data or technical expertise, some facilities cannot create valid linear regression models. For these cases, CEI is the only option. Here, the goal of this article is to develop a new methodology, modified energy intensity (MEI), which is more accurate than CEI, but requires much less data and is easier to implement than LRM. Using the underlying principle of LRM, this article first outlines the mathematical derivation of the equations for MEI, then explains them from an engineering perspective. Finally, the implementation of MEI is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential retrofits at scale: opportunity identification, saving estimation, and personalized messaging based on communicating thermostat data

Basic insulation and heating system retrofits of existing homes could achieve annual energy savings of up to $4–5 billion in the USA. However, current US utility energy efficiency (EE) programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and on-line advertising that lack specificity about particular home retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments that can be inconvenient to homeowners, expensive, and of variable accuracy. Our paper discusses using communicating thermostat data to significantly increase the customer uptake of energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. We extended our previously developed gray-box building model to identify physical building parameters corresponding to the target retrofit opportunities, i.e., whole-home R value, air leakage characteristics, and heating system efficiency. Here, the estimated R values and air leakage characteristics compare favorably with the ground truth. The validated algorithms can calculate home-specific energy savings estimate for each ECM, and the algorithm outputs can be used by utility EE programs to formulate home-specific retrofit offers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Evaluation of a New Construction Pilot Community: Fresno, California

A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes (WCHH) based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the House Simulation Protocols (Hendron, Robert; Engebrecht, Cheryn (2010). Building America House Simulation Protocols. Golden, CO: National Renewable Energy Laboratory). Builders face several key problems when implementing a whole-house systems integrated measures package (SIMP) from a single test house into multiple houses. Although a technical solution already may have been evaluated and validated in an individual test house, the potential exists for constructability failures at the community scale. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a SIMP and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Low-Cost Evaluation of Energy Savings at the Community Scale, Fresno, California (Fact Sheet)

A new construction pilot community was constructed by builder-partner Wathen-Castanos Hybrid Homes (WCHH) based on a single occupied test house that was designed to achieve greater than 30% energy savings with respect to the House Simulation Protocols (Hendron, Robert; Engebrecht, Cheryn (2010). Building America House Simulation Protocols. Golden, CO: National Renewable Energy Laboratory.). Builders face several key problems when implementing a whole-house systems integrated measures package (SIMP) from a single test house into multiple houses. Although a technical solution already may have been evaluated and validated in an individual test house, the potential exists for constructability failures at the community scale. This report addresses factors of implementation and scalability at the community scale and proposes methodologies by which community-scale energy evaluations can be performed based on results at the occupied test house level. Research focused on the builder and trade implementation of a SIMP and the actual utility usage in the houses at the community scale of production. Five occupants participated in this community-scale research by providing utility bills and information on occupancy and miscellaneous gas and electric appliance use for their houses. IBACOS used these utility data and background information to analyze the actual energy performance of the houses. Verification with measured data is an important component in predictive energy modeling. The actual utility bill readings were compared to projected energy consumption using BEopt with actual weather and thermostat set points for normalization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chicago Energy Efficiency Planning and Analysis and Integrated Retrofit Strategy Validation in Single-Family Homes

In June 2020, the project team comprised of Elevate and the National Renewable Energy Laboratory (NREL), with advisory roles from the City of Chicago and Commonwealth Edison, initiated a three-year project with the U.S. Department of Energy to inform communitywide energy planning at a local scale and validate advanced retrofit packages that achieve at least 50% energy savings in existing homes. The project team has characterized Chicago’s single-family and 2-4 unit housing stock and energy use using the ResStock™ modeling tool, and with that information developed advanced whole home energy retrofit packages for single family and 2-4 unit homes that can reduce energy use by at least 50% and support climate, air quality, and other goals. This report presents an analysis of the technical potential of applying these retrofit packages at a City-wide scale, and a roadmap for rapidly scaling up retrofit programs to improve Chicago’s housing stock and target investments in the neighborhoods that need it most. The main goals of the analysis are to: 1) develop a Chicago-specific single-family and 2-4 unit building retrofit prioritization strategy; 2) identify opportunities for beneficial electrification in communities and home types that stand to benefit most; and 3) assess costs and savings potential for retrofit investments at a household and city scale, in terms of energy use, bill impacts, carbon emissions, and other outcomes.

14 SOLAR ENERGY↗

ResStock Measure Documentation: Residential Single-Stage Geothermal Heat Pump (3.8 COP, 18.6 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Single-Stage Geothermal Heat Pump (GHP).?Single-stage GHPs are able to reduce energy consumption by 31% for the entire stock. Additional results provided below detail how savings changes for sections of the housing stock with different base heating fuel and in different climate zones, as well as the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

Sulfur Metabolites Play Key System-Level Roles in Modulating Denitrification

Competition between nitrate-reducing bacteria (NRB) and sulfate-reducing bacteria (SRB) for resources in anoxic environments is generally thought to be governed largely by thermodynamics. It is now recognized that intermediates of nitrogen and sulfur cycling (e.g., hydrogen sulfide, nitrite, etc.) can also directly impact NRB and SRB activities in freshwater, wastewater, and sediment and therefore may play important roles in competitive interactions. Here, through comparative transcriptomic and metabolomic analyses, we have uncovered mechanisms of hydrogen sulfide- and cysteine-mediated inhibition of nitrate respiratory growth for the NRB Intrasporangium calvum C5. Specifically, the systems analysis predicted that cysteine and hydrogen sulfide inhibit growth of I. calvum C5 by disrupting distinct steps across multiple pathways, including branched-chain amino acid (BCAA) biosynthesis, utilization of specific carbon sources, and cofactor metabolism. Here, we have validated these predictions by demonstrating that complementation with BCAAs and specific carbon sources relieves the growth inhibitory effects of cysteine and hydrogen sulfide. We discuss how these mechanistic insights give new context to the interplay and stratification of NRB and SRB in diverse environments.

59 BASIC BIOLOGICAL SCIENCES↗

Correlating and Simulating Socio-Demographically Driven Residential End-Use Activity Schedules

Incorporating socio-demographic and behavioral considerations into decision-support tools is crucial for identifying gaps and addressing consumer needs to ensure reliable and affordable energy solutions. In energy simulation models, the correlation between socio-demographics and time-use behavior is not well-captured. Thus, we developed a large-scale simulation workflow to generate schedules for 10 residential activities across 24 population segments defined by age, income, and employment status. Using pre-pandemic 2015-2019 American Time Use Survey (ATUS) data, we used ANOVA to confirm the correlation between demographic factors and time use. We explored three k-modes clustering methods-backward, forward, and a new hybrid approach-to delineate the occupancy patterns based on demographics. Using the probability of cluster membership for each population segment and a time inhomogeneous Markov chain to generate activity transition probabilities for each cluster, we simulated 50,000 schedules per segment and validated them against the ATUS data. The hybrid method produced the most socio-demographically differentiated clusters while demonstrating comparable performance to other approaches, with an overall root mean square error of 0.12 for both weekday and weekend schedules. Thus, the hybrid method, where each cluster is dominated by certain demographic segments and occupancy patterns, offers more modeling versatility in terms of scenario analysis. The new workflow improves the socio demographic differentiation of energy consumption by considering differences in time use. This approach enables future research on demographically segmented time of use (TOU) energy consumption, including impacts of TOU utility bills and rate analysis, long-run marginal emissions, and energy retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY12-Q3 National Risk Assessment Partnership (NRAP): Industrial Carbon Capture Program (Quarterly Report for LANL Activities)

This report summarizes progress of LANL activities related to the tasks performed under the LANL FWP FE102-002-FY10, National Risk Assessment Partnership (NRAP): Industrial Carbon Capture Program. This FWP is funded through the American Recovery and Reinvestment Act (ARRA). Overall, the NRAP activities are focused on understanding and evaluating risks associated with large-scale injection and long-term storage of CO 2 in deep geological formations. One of the primary risks during large-scale injection is due to changes in geomechanical stresses to the storage reservoir, to the caprock/seals and to the wellbores. These changes may have the potential to cause CO 2 and brine leakage and geochemical impacts to the groundwater systems. While the importance of these stresses is well recognized, there have been relatively few quantitative studies (laboratory, field or theoretical) of geomechanical processes in sequestration systems. In addition, there are no integrated studies that allow evaluation of risks to groundwater quality in the context of CO 2 injection-induced stresses. The work performed under this project is focused on better understanding these effects. LANL approach will develop laboratory and computational tools to understand the impact of CO 2 -induced mechanical stress by creating a geomechanical test bed using inputs from laboratory experiments, field data, and conceptual approaches. The Geomechanical Test Bed will be used for conducting sensitivity and scenario analyses of the impacts of CO 2 injection. The specific types of questions will relate to fault stimulation and fracture inducing stress on caprock, changes in wellbore leakage due to evolution of stress in the reservoir and caprock, and the potential for induced seismicity. In addition, the Geomechanical Test Bed will be used to investigate the coupling of stress-induced leakage pathways with impacts on groundwater quality. LANL activities are performed under two tasks: 1) develop laboratory and computational tools to understand CO 2 -induced mechanical impacts and 2) use natural analog sites to determine potential groundwater impacts. We are using the Springerville-St. John Dome as a field site for collecting field data on CO 2 migration through faults and groundwater impacts as well as developing and validating computational models. During the FY12 fourth quarter we received the tri-axial core-holder from New England Research Company (NERC). We have completed the construction of the experimental set up for performing coupled flow-stress experiments. We will be completing first set of flow through experiments in October.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

H2FIRST Reference Station Design Task: Project Deliverable 2-2

This report presents near-term station cost results and discusses cost trends of different station types. It compares various vehicle rollout scenarios and projects realistic near-term station utilization values using the station infrastructure rollout in California as an example. It describes near-term market demands and matches those to cost-effective station concepts. Finally, the report contains detailed designs for five selected stations, which include piping and instrumentation diagrams, bills of materials, and several site-specific layout studies that incorporate the setbacks required by NFPA 2, the National Fire Protection Association Hydrogen Technologies Code. This work identified those setbacks as a significant factor affecting the ability to site a hydrogen station, particularly liquid stations at existing gasoline stations. For all station types, utilization has a large influence on the financial viability of the station.

30 DIRECT ENERGY CONVERSION↗

NASA Crew Launch Vehicle Approach Builds on Lessons from Past and Present Missions

The United States Vision for Space Exploration, announced in January 2004, outlines the National Aeronautics and Space Administration's (NASA) strategic goals and objectives, including retiring the Space Shuttle and replacing it with a new human-rated system suitable for missions to the Moon and Mars. The Crew Exploration Vehicle (CEV) that the new Crew Launch Vehicle (CLV) lofts into space early next decade will initially ferry astronauts to the International Space Station and be capable of carrying crews back to lunar orbit and of supporting missions to Mars orbit. NASA is using its extensive experience gained from past and ongoing launch vehicle programs to maximize the CLV system design approach, with the objective of reducing total lifecycle costs through operational efficiencies. To provide in-depth data for selecting this follow-on launch vehicle, the Exploration Systems Architecture Study was conducted during the summer of 2005, following the confirmation of the new NASA Administrator. A team of aerospace subject matter experts used technical, budget, and schedule objectives to analyze a number of potential launch systems, with a focus on human rating for exploration missions. The results showed that a variant of the Space Shuttle, utilizing the reusable Solid Rocket Booster as the first stage, along with a new upper stage that uses a derivative of the RS-25 Space Shuttle Main Engine to deliver 25 metric tons to low-Earth orbit, was the best choice to reduce the risks associated with fielding a new system in a timely manner. The CLV Project, managed by the Exploration Launch Office located at NASA's Marshall Space Flight Center, is leading the design, development, testing, and operation of this new human-rated system. The CLV Project works closely with the Space Shuttle Program to transition hardware, infrastructure, and workforce assets to the new launch system . leveraging a wealth of lessons learned from Shuttle operations. The CL V is being designed to reduce costs through a number of methods, ranging from validating requirements to conducting trades studies against the concept design. Innovations such as automated processing will build on lessons learned from the Shuttle, other launch systems, Department of Defense operations experience, and subscale flight tests such as the Delta Clipper-Experimental Advanced (DCXA) vehicle operations that utilized minimal touch labor, automated cryogen ic propellant loading , and an 8-hour turnaround for a cryogenic propulsion system. For the CLV, the results of hazard analyses are contributing to an integrated vehicle health monitoring system that will troubleshoot anomalies and determine which ones can be solved without human intervention. Such advances will help streamline the mission operations process for pilots and ground controllers alike. In fiscal year 2005, NASA invested approximately $4.5 billion of its $16 bill ion budget on the Space Shuttle. The ultimate goal of the CLV Project is to deliver a safe, reliable system designed to minimize lifecycle costs so that NASA's budget can be invested in missions of scientific discovery. Lessons learned from developing the CLV will be applied to the growth path for future systems, including a heavy lift launch vehicle.

Dumbacher, Daniel L.↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

Performance Results from DOE Cold Climate Heat Pump Challenge Field Validation

Space conditioning and water heating consume over 40% of the nation’s primary energy use and represent a significant component of many homeowners’ monthly energy bill. However, in cold climates, performance of heat pumps has traditionally suffered as the units have been unable to efficiently transfer heat from colder outdoor air temperatures to warm the interior space of homes. Optimizing heat pumps for cold climates (5 °F and below) requires coordinated effort to ensure heat pump technologies can be enjoyed by Americans living in these regions. The DOE Cold Climate Heat Pump (CCHP) Challenge sought to address this challenge by partnering with industry to develop, test, and validate the performance of new, highly efficient heat pumps in real homes. The Challenge, launched in 2021, brought together leading heating, ventilation, and air conditioning (HVAC) manufacturers to develop prototype units optimized for performance at cold climates. This report summarizes results from the field validation that occurred 2022-2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep in Data: Empirical Data Based Software Accuracy Testing Using the Building America Field Data Repository: Preprint

An opportunity is available for using home energy consumption and building description data to develop a standardized accuracy test for residential energy analysis tools. That is, to test the ability of uncalibrated simulations to match real utility bills. Empirical data collected from around the United States have been translated into a uniform Home Performance Extensible Markup Language format that may enable software developers to create translators to their input schemes for efficient access to the data. This may facilitate the possibility of modeling many homes expediently, and thus implementing software accuracy test cases by applying the translated data. This paper describes progress toward, and issues related to, developing a usable, standardized, empirical data-based software accuracy test suite.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Through Lighting Upgrades

Lighting upgrades including neon to LED, incandescent to CFL's and T-12 to T-8 and T-5's were completed through this grant. A total of 16 Chickasaw nation facilities decreased their carbon footprint because of these grant funds. Calculations used were based on comparing the energy usage from the previous year's average and the current energy usage. For facilities without a full year's set of energy bills, the month after installation was compared to the same month from the previous year. Overall, the effect the lighting change-outs had for the gaming centers and casinos far exceeded expectations. For the Madill Gaming Center; both an interior and exterior upgrade was performed which resulted in a 31% decrease in energy consumption. This same reduction was seen in every facility that participated in the grant. Just by simply changing out light bulbs to newer energy efficient equivalents, a decrease in energy usage can be achieved and this was validated by the return on investment seen at Chickasaw Nation facilities. Along with the technical project tasks were awareness sessions presented at Chickasaw Head Starts. The positive message of environmental stewardship was passed down to head start students and passed along to Chickasaw employees. Excitement was created in those that learned what they could do to help reduce their energy bills and many followed through and took the idea home. For a fairy low cost, the general public can also use this technique to lower their energy consumption both at home and at work. Although the idea behind the project was somewhat simple, true benefits have been gained through environmental awareness and reductions of energy costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving 50% Energy Savings in Chicago Homes: A Case Study for Advancing Equity and Climate Goals

Since 2019, the National Renewable Energy Laboratory (NREL) and Elevate have collaborated to identify pathways to deep energy retrofits in Chicago's housing stock, document equity implications and co-benefits of this transition, and validate the findings by implementing retrofits in real Chicago homes. This document summarizes our analysis process to model advanced retrofit packages that lead to greater than 50% energy savings in Chicago homes. Based on these findings, we have also developed a roadmap with the City to guide implementation, and are deploying the recommended retrofit packages in real Chicago homes to realize these energy savings. This work was developed in collaboration with two key stakeholders - the City of Chicago and Commonwealth Edison (ComEd) - and funded by the U.S. Department of Energy (DOE). NREL's Residential Buildings team maintains the best-in-class ResStock™ energy model of the U.S. residential building stock. For this work, we calibrated ResStock to Chicago's unique local housing stock to accurately simulate energy use in Chicago homes both for current conditions and with various retrofit scenarios. We simulated a wide range of potential building retrofits covering all aspects of residential energy use and then grouped these into packages based on energy and utility bill savings. ResStock can model diverse building types and housing characteristics, so we're able to observe the range of outcomes that might occur when these upgrades are deployed across the entire housing stock. We can then estimate potential energy savings from an advanced retrofit program on Chicago's housing stock by comparing the modeled energy use before versus after a retrofit. This novel version of ResStock, calibrated to Chicago with data from Elevate, can help City officials, ComEd, and other partners plan for community-scale decarbonization via residential retrofits. Specifically, this work contributes the following project goals: Develop a building retrofit prioritization strategy for Chicago single-family and 2- to 4-unit buildings; Identify neighborhoods and home types that have the highest potential for savings from electrification; and Assess the impact of advanced building retrofits on energy use, utility bills, and CO2 emissions at the city and building level. Although this study is specific to Chicago, its methods and learnings are applicable across the United States. These findings are especially notable for heat pumps and electrification retrofits in cold climates.

building energy modeling↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗