Search NASA⌕ Search

SEARCH · Search NASA

Results for “water supply systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Data-driven modeling to enhance municipal water demand estimates in response to dynamic climate conditions

Altered precipitation and temperature patterns from a changing climate will affect supply, demand, and overall municipal water system operations throughout the arid western U.S. While supply forecasts leverage hydrological models to connect climate influences with surface water availability, demand forecasts typically estimate water use independent of climate and other externalities. Stemming from an increased focus on seasonal water demand management, we use the Salt Lake City, Utah municipal water system as a test bed to assess model accuracy versus complexity trade-offs between simple climate-independent econometric-based models and complex climate-sensitive data-driven models to average to extreme wet and dry climate conditions—representative of a new climate normal. Here, the climate-independent model displayed low performance during extreme dry conditions with predictions exceeding 90% and 40% of the observed monthly and seasonal volumetric demands, respectively, which we attribute to insufficient model complexity. The climate-sensitive models displayed greater accuracy in all conditions, with an ordinary least squares model demonstrating a measurable reduction in prediction bias (3.4% vs. -27.3%) and RMSE (74.0 lpcd vs. 294 lpcd) compared to the climate-independent model. The climate-sensitive workflow increased model accuracy and characterized climate-demand interactions, demonstrating a novel tool to enhance water system management.

54 ENVIRONMENTAL SCIENCES↗

A Year-Round Energy-Efficient Fresh Air Handling System with Two-Stage Heat Pumps and Lake Water Pre-Treatment

Supplying fresh air is important for indoor air quality, but the energy consumption to treat fresh air is significant. The main problems in existing fresh air system include: supplying single-temperature water to treat fresh air and not applying natural energy sufficiently restrict the efficiency improvement of cooling and heat sources; unused air handling devices under most operating conditions throughout the year increase the fan energy consumption. Thus, this study proposes an efficient fresh air system that uses lake water to pre-treat fresh air and two-stage heat pumps for further treatment, and the unused air handling devices in the system are bypassed. A fresh air system in northern China is selected as a case to show the annual energy performance of the proposed system, and a comparative analysis is conducted between the proposed system and a traditional system. The results show that the annual energy-savings of the proposed system compared to the traditional system come from fans, and compressors, which are 56.5%, and 31.1%, respectively, with an entire system energy saving of 32.2%. The proposed system can achieve an annual system coefficient of performance (COP) of 5.5. This study provides potential for further improving the energy efficiency in fresh air treatment.

Liang, Chenjiyu↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Enabling residential heating decarbonization through hydronic low-temperature thermal distribution using forced-air assistive devices

Space heating represents approximately one-tenth of the United States’ energy use and has a breadth of potential for emission reduction. An element of space heating, hydronic heat distribution methods, use water supply temperatures up to 82.2 °C (180 °F). However, this operating temperature can be incompatible with high-efficiency heat generation systems, which typically provide heating temperatures of up to 60 °C (140 °F). In this work, a low-cost retrofit solution is developed using experimentally validated computational tools by incorporating an airflow distributor that preferentially directs the airflow from a fan to enhance heat transfer over the finned-tube heat exchanger found in conventional baseboards. The same heat output of traditional baseboard heat distribution systems operating at higher water supply temperatures (71.1 – 82.2 °C) can also be achieved at lower temperatures (≤60 °C). Specifically, results indicate that the technology can produce more than a 46.7% improvement in the heat transfer output at temperatures as low as 60 °C (140 °F), effectively matching the same output range achieved by 71.1 – 82.2 °C (160–180 °F) water supply temperatures. An important benefit of this solution is that it utilizes the existing infrastructure as opposed to requiring the replacement of the entire distribution system. Additionally, this technology enables existing building infrastructure to be coupled with newer, high-efficiency heating systems such as condensing boilers, solar-thermal systems, and geothermal/air-to-water heat pumps that may produce lower water supply temperatures (60 °C). A geospatially resolved techno-economic and environmental analysis is completed and presented to further understand the equivalent carbon footprint of enabling higher efficiency heat generation systems with the improved efficiency heat distribution system disclosed. Using 2021 grid-average emission factors, an emission reduction of up to a 67.5% decrease (2658 kgCO 2 /yr) for a single-family home, depending on state and climate region, could be realized by replacing a traditional natural gas-fired boiler with an air-to-water heat pump coupled to the same high-temperature heat distribution system along with the low-cost retrofit solution. A complete CO 2 emission reduction of 6688 kgCO 2 /yr, depending on state and climate region, could be realized if all electricity is further renewably sourced. Thus, this study provides a possible pathway towards enabling the reduction of operational emissions in space heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evolution of global snow drought characteristics from 1850 to 2100

Abstract Seasonal snow is an integral part of the global water supply and storage system. Snow droughts impact ecological, agricultural, and urban systems by altering the amount and timing of meltwater delivery. These droughts are characterized by a lack of on-the-ground snow (snow water equivalent, SWE) that can be caused by low total precipitation (dry drought) or low proportion of precipitation falling as snowfall (warm drought), often combined with an early melt. The standardized SWE index (SWEI) ranks the current status of SWE for a given location compared to a baseline condition and identifies the existence, but not the cause, of snow drought. In this work, we use estimates of SWE, temperature, and precipitation from nine coupled model intercomparison project phase 6 (CMIP6) models to quantify the frequency, severity, and type of snow droughts globally for historical and future scenarios. Compared to a historical baseline (1850–1900) total snow drought frequency more than doubles under socio-economic pathway (SSP)2-4.5 and SSP5-8.5; all of the increase in snow drought frequency comes from an increase in warm droughts. The probability distribution of future SWEI in major snowy basins around the world are likely to be centered on more negative values, which corresponds to more severe drought and, with only moderate changes in distribution spread, more frequent drought. CMIP6 simulations pinpoint snow drought as an emerging global threat to water resources and highlight the need to explore higher resolution future models that better capture complex mountain topography, wildland fires, and snow-forest interactions.

CMIP6↗

A tandem radiative/evaporative cooler for weather-insensitive and high-performance daytime passive cooling

Radiative cooling and evaporative cooling with low carbon footprint are regarded as promising passive cooling strategies. However, the intrinsic limits of continuous water supply with complex systems for evaporative cooling, and restricted cooling power as well as the strict requirement of weather conditions for radiative cooling, hinder the scale of their practical applications. Here, we propose a tandem passive cooler composed of bilayer polymer that enables dual-functional passive cooling of radiation and evaporation. Specifically, the high reflectivity to sunlight and mid-infrared emissivity of this polymer film allows excellent radiative cooling performance, and its good atmospheric water harvesting property of underlayer ensures self-supply of water and high evaporative cooling power. Consequently, this tandem passive cooler overcomes the fundamental difficulties of radiative cooling and evaporative cooling and shows the applicability under various conditions of weather/climate. It is expected that this design can expand the practical application domain of passive cooling.

54 ENVIRONMENTAL SCIENCES↗

Manganese in drinking-water reservoirs: a multi-disciplinary review of current issues, biogeochemical controls, and oxygenation-based management

Decreased water quality and increased treatment costs due to excess manganese (Mn) in drinking-water supplies are critical issues globally. To combat on-going and emerging taste and odour issues with Mn and other contaminants (e.g., algal toxins), many utilities are using engineered oxygenation or aeration (EOA) systems to improve water quality in lakes and reservoirs. Resultant shifts in key biogeochemical and physical processes are still poorly understood, often leading to inefficiently managed systems. Paired with knowledge gaps regarding environmental drivers of Mn and the complexity of Mn redox kinetics, Mn problems persist. This review presents the state of current research in areas critical to optimisation of EOA mitigation of Mn, with focus on i) Mn biogeochemical cycling within drinking-water reservoirs; ii) influences of local catchment geology, hydrology, and land use on Mn dynamics; and iii) Mn management using different EOA approaches. The importance of considering the combined implications of these factors for successful Mn management in reservoirs is highlighted by an evaluation of relevant field-based studies; a wide range in EOA performance is observed, from a 97 % decrease in soluble Mn up to a ∼400 % increase in total Mn. Despite the breadth of studies that consider Mn in water-supply systems, there are still several areas of research which warrant further investigation, including: the influence of natural sources and anthropogenic activities on Mn within a given catchment, Mn speciation and transport in stratified and destratified lakes and reservoirs, and optimal site-specific EOA strategies for Mn mitigation.

Aeration↗

Comparative Techno-Economic and Life Cycle Analysis of Water Oxidation and Hydrogen Oxidation at the Anode in a CO 2 Electrolysis to Ethylene System

We compare the economic viability of employing hydrogen oxidation versus water oxidation at the anode of a commercial-scale electrolysis plant that converts CO 2 to ethylene. We vary the electrolyzer capital cost, membrane lifetime, and renewable electricity price to represent a current and future market scenario. We find that anodic hydrogen oxidation with membraneless reactor design can reduce the electrolyzer capital cost by up to 48% and reduce electricity demand by at least 50% with the current underdeveloped electrolyzer market. These capital and operating cost savings could further lead to a lower ethylene production cost from anodic hydrogen oxidation than the anodic water oxidation system with hydrogen supplied at less than $\$6$ kg. In the future scenario with a fully developed electrolyzer market and cheap renewable electricity, we find that the anodic hydrogen oxidation system requires hydrogen cheaper than $0.7/kg to compete with the anodic water oxidation system. Moreover, hydrogen oxidation at the anode enables extremely low cradle-to-gate emission ethylene by utilizing negative emission hydrogen such as biomass gasification with carbon capture and sequestration, ~240% lower than ethylene produced from the wind/solar electricity-driven water oxidation system. Furthermore, this low carbon footprint ethylene can further boost the economic competitiveness for anodic hydrogen oxidation with a future carbon credit market.

54 ENVIRONMENTAL SCIENCES↗

Desalination for a circular water economy

Today's water systems are enabled by ample fresh water sources, low-cost centralized treatment, and facile wastewater disposal. Climatic change, aging infrastructure, and source water contamination have exposed the vulnerabilities of this linear water paradigm. While seawater desalination enables coastal communities to augment their supply, more broadly securing water systems for municipal, industrial, and agricultural water users will require distributed desalination and fit-for-purpose reuse of nontraditional water sources. Our linear water economy must evolve into a resilient circular water economy, where water is continuously reused and “contaminants” become the feedstocks for other economically valuable processes. Additionally, technology innovation is needed to deliver autonomous, precise, resilient, intensified, modular, and electrified desalination systems that reduce the cost, improve the performance, and enhance the resilience of nontraditional water reuse systems. Meanwhile, strong federal leadership and coordination is needed to accelerate desalination research, promote information gathering efforts to direct technology development, and create an expanded role for non-profit organizations in knowledge dissemination.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Applying a Multisector Scenario Framework to Evaluate Past and Future Public Surface Water Supply Infrastructure Strategies in Texas

Datasets supporting the index model and scenario analysis used in evaluating surface water supply strategies across different water system types in Texas. These data underpin the scenario development and application of five key indicators: Water Availability Index (WAI), Water Quality Index (WQI), Energy Requirement Index (ERI), Water Treatment Cost (WTC), and Water Infrastructure Cost (WIC). The datasets are organized by system type—stream reaches (flowlines), waterbodies, and reservoirs—and include both raw and standardized index values. The integrated datasets also provide scenario classifications (original and adjusted) based on infrastructure and planning priorities, enabling comparison across Shared Socioeconomic Pathways (SSPs). Additional strategy-level data are included to support evaluation of state-level new reservoir projects in relation to cost and availability tradeoffs. Please refer to the README file provided in Files for more details. Descriptions of the datasets are provided below. Dataset(s) Descriptions Folder: Index_model_database.zip Subfolder: Stream_reach.zip Fl_wf.csv, Fl_wq.csv, Fl_er.csv, Fl_wf_wtcUV.csv, Fl_wf_wtcnoUV.csv, Fl_allfac_wic1.csv, Fl_allfac_wic2.csvDatasets for computing WAI, WQI, ERI, WTC, and WIC for surface water systems classified as stream reaches (flowlines). Subfolder: Waterbody.zip Wb_wf.csv, Wb_wq.csv, Wb_er.csv, Wb_wf_wtcUV.csv, Wb_wf_wtcnoUV.csv, Wb_allfac_wic1.csv, Wb_allfac_wic2.csvEquivalent index model datasets for waterbodies, reflecting hydrologic and infrastructure attributes specific to impounded natural systems. Subfolder: Reservoir.zip Rs_wf.csv, Rs_wq.csv, Rs_er.csv, Rs_wf_wtcUV.csv, Rs_wf_wtcnoUV.csv, Rs_allfac_wic1.csv, Rs_allfac_wic2.csvIndex model datasets specific to regulated reservoir systems, incorporating both resource indicators and cost parameters. Folder: Integrated data.zip combined_merged_data.csv, combined_merged_data_scenario.csvDatasets integrating index model indicators (both raw and scaled) with scenario classifications, including adjustments reflecting SSP-aligned transitions and planning shifts. Folder: Additional data.zip wai_supplystrat_wic_merged.csvCurated dataset capturing proposed major reservoir-based municipal water supply strategies in Texas. Integrates site-level planning data with estimated capital infrastructure costs and water availability scores for comparative assessment.

geospatial↗

Characterizing the multisectoral impacts of future global hydrologic variability

There is significant uncertainty in how global water supply will evolve in the future, due to uncertain climate, socioeconomic, and land use change drivers and variability of hydrologic processes. It is critical to characterize the potential impacts of uncertainty in future water supply given its importance for food and energy production. In this work, we introduce a framework that integrates stochastic hydrology and human-environmental systems to characterize uncertainty in future water supply and its multisector impacts. We develop a global stochastic watershed model and demonstrate that this model can generate a large ensemble of realizations of basin-scale runoff with global coverage that preserves the mean, variance, and spatial correlation of a historical benchmark. We couple this model with a well-known human-environmental systems model to explore the impacts of runoff variability on the water and agricultural sectors across spatial scales. We find that the impacts of future hydrologic variability vary across sectors and regions. Impacts are felt most strongly in the water and agricultural sectors for basins that are expected to have unsustainable water use in the future, such as the Indus River basin. For this basin, we find that the variability in future irrigation water withdrawals and irrigated cropland increase over time due to uncertainty in renewable water supply. We also use the Indus basin to show how our stochastic ensemble can be leveraged to explore the global multisector consequences of local extreme runoff conditions. This work introduces a novel technique to explore the propagation of future hydrologic variability across human and natural systems and spatial scales.

54 ENVIRONMENTAL SCIENCES↗

Laboratory Testing and Performance Characterization of the High Efficiency Dehumidification System (HEDS) Technology

The high efficiency dehumidification system (HEDS) is a unique air handling unit (AHU) design with two water coils. Connected in series, these water coils can sensibly reheat the airstream after it is cooled and dehumidified, thereby mitigating (or sometimes eliminating) the need for conventional sensible reheat with additional energy from hot water, electric resistance or steam coils. Another unique design feature is the size of the HEDS primary cooling coil. While typical AHU cooling coils have a 6-row geometry, the HED's cooling coil has a deeper 10-row geometry enabling discharge air dew point temperatures at or below 55 degrees F despite warmer chilled water supply temperatures approaching (sometimes exceeding) 50 degrees F. The ability to meet acceptable discharge air dew points with warmer chilled water supply temperatures improves both operational efficiency and system resilience against chilled water plant operational or control issues. This report summarizes the 59 steady-state test results that form a comprehensive performance map of the HEDS technology including its reheat capability. The breadth of outdoor air conditions and flow rates over which the HEDS technology was tested and characterized encompasses the unit 1) operating as a dedicated outdoor air system or mixed air system and 2) controlled with constant air volume or variable air volume fan control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analytical investigation of the dew point water recovery system with potential application for drinking water production

The article presents the analytical investigation of the Dew Point Water Recovery (DPWR) system with potential application for drinking water production. Four different configurations of the DPWR system were proposed, differing in the number and type of dew point cooling exchangers used, and their operation was described using a validated convective heat transfer coefficient mathematical model. It was found that the three stage configu-ration of the DPWR system with a regenerative exchanger has the best water recovery performance, while the three stage configuration with a counter-flow exchanger has the best ratio of energy supplied to the system in relation to the amount of water produced. It was also found that the DPWR system can operate in a wide range of operating conditions with a specific electric energy consumption reaching below 0.9 kWh/m 3 and GOR in the range of 0.36-2.16. What distinguishes the DPWR system from other methods of drinking water production is the ability to work without an additional source of thermal energy apart from the energy of the air supplied to the system. Thanks to this property, the system has the potential to fill the technological gap of a low-energy and easily accessible method of drinking water production.

42 ENGINEERING↗

Failure analysis of a cooling pump using modal and vibration analysis

Four pumps redundantly supply cooling water to a system. All four pumps underwent maintenance during a recently scheduled downtime. During preliminary evaluation following maintenance, one pump, the subject of this document, exhibited higher vibration levels compared to the other three pumps. The pump underwent further performance testing to rule out potential damage resulting from the higher vibration. Vibration analysis and modal analysis including steady state spectrum, operational deflection shape, run up transients, and modal impact have been utilized to identify dynamic characteristics that could contribute to the increased vibration levels. This article will cover the testing setup, methodology, analysis results, and recommendations.

42 ENGINEERING↗

Comparative life cycle assessment of remote potable water supply for the Department of Defense

The Department of Defense (DOD) and other agencies, including relief organizations, require potable water for remote missions around the globe. As part of recent initiative by the U.S. Federal government through Executive Order 14057, the DOD has been instructed to investigate the sustainability of operations and practices within the context of climate change. One such practice that needs to be addressed is the procurement of potable water, an essential requirement of any remote mission or location. Currently, there are three primary means of procuring potable water at remote locations: bottled water, on-site purification, or tie-in to existing, local infrastructure. The first two operations are often considered the most secure options, but have sustainability concerns. The purpose of this study is to compare the environmental impacts of bottled water procurement versus on-site treatment via a mobile Reverse Osmosis Water Purification Unit (ROWPU), which uses multiple levels of filtration to make potable water from a local source. A cradle-to-gate assessment was developed for both systems to compare different options for potable water supply. An in person inventory was paired with data taken from the Ecoinvent 3.8 database to directly compare the two systems. The two systems are compared on a 5-year timeline to analyze the environmental impact of repeated bottled water transport versus diesel generator-fueled on-site treatment. Across all impact categories, the results indicate that high energy costs of the reverse osmosis process have significantly less impact on the environment than the repetitive transport and procurement of bottled water. The results of the study have important implications for advancing sustainable operations for remote communities or temporary settlements.

54 ENVIRONMENTAL SCIENCES↗

Photovoltaic-assisted heat pump water heater system and method

A solar power system has a photovoltaic module that supplies electrical current derived from sunlight to a heater system of a hot water tank. The heater system uses the electrical energy from the photovoltaic module, and optionally also from a local power grid, to heat water up to a selected maximum stored hot water temperature. Control circuitry senses when the level of electrical power is below a threshold solar-power level, and in response sets the stored hot water temperature for the heater system to a first lower temperature value. The control circuitry also senses when the level of electrical power is above the threshold solar-power level, an in response sets the stored hot water temperature for the heater system to a second elevated temperature value higher than the lower temperature, making advantageous use of solar power when available. A mixing unit adds cold water to set the dispensed water temperature.

14 SOLAR ENERGY↗

Emerging Technologies Review: Water Reuse Systems for Cooling Tower Applications

This report explores the concept of water reuse systems for cooling tower water makeup, specifically focusing on the use of alternative water sources, and the viability of these systems for Air Force installations and operations. Cooling is a critical requirement for DAF operations, and alternative water supplies that enable cooling tower use during a disruption of utility-supplied water increase Air Force resilience. The components of a water reuse system for cooling towers include alternative water supplies, storage, treatment, and distribution in addition to the cooling tower itself. Alternative water sources are not derived from fresh surface water or groundwater and can provide a redundant water supply to utility supply or to fresh water produced on site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Policy Brief: Integrated Nexus Policies for Sustainable and Resilient Energy, Water, and Food Systems

Population growth, climate change, and resource depletion put food and water security and energy supply at risk. Sustainable and resilient water, food, and energy systems are crucial to meet Sustainable Development Goals (SDGs) and increase resilience to global health crises such as the COVID-19 pandemic. This policy brief describes the challenges and presents proposals regarding synergies in the land, water, and energy nexus to maximize net environmental, health, and social benefits. First, this brief focuses on water desalination, where the nexus approach helps to balance the full cost, including externalities, of desalinated water, and its socio-economic benefits. Second, this policy brief highlights nutrition-sensitive food policies that improve health and contribute to the preservation of natural resources. Finally, this brief presents challenges and opportunities for developing renewable energy.

energy↗