Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray diffraction detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characterization of MoS 2 films via simultaneous grazing incidence X-ray diffraction and grazing incidence X-ray fluorescence (GIXRD/GIXRF)

Physical vapor deposited (PVD) molybdenum disulfide (nominal composition MoS 2 ) is employed as a thin film solid lubricant for extreme environments where liquid lubricants are not viable. The tribological properties of MoS 2 are highly dependent on morphological attributes such as film thickness, orientation, crystallinity, film density, and stoichiometry. These structural characteristics are controlled by tuning the PVD process parameters, yet undesirable alterations in the structure often occur due to process variations between deposition runs. Nondestructive film diagnostics can enable improved yield and serve as a means of tuning a deposition process, thus enabling quality control and materials exploration. Grazing incidence X-ray diffraction (GIXRD) for MoS 2 film characterization provides valuable information about film density and grain orientation (texture). However, the determination of film stoichiometry can only be indirectly inferred via GIXRD. The combination of density and microstructure via GIXRD with chemical composition via grazing incidence X-ray fluorescence (GIXRF) enables the isolation and decoupling of film density, composition, and microstructure and their ultimate impact on film layer thickness, thereby improving coating thickness predictions via X-ray fluorescence. We have augmented an existing GIXRD instrument with an additional X-ray detector for the simultaneous measurement of energy-dispersive X-ray fluorescence spectra during the GIXRD analysis. This combined GIXRD/GIXRF analysis has proven synergetic for correlating chemical composition to the structural aspects of MoS 2 films provided by GIXRD. We present the usefulness of the combined diagnostic technique via exemplar MoS 2 film samples and provide a discussion regarding data extraction techniques of grazing angle series measurements.

MoS2↗

X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids

We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.

Crystal lattices↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

Nucleation and growth of polar clusters with in-phase tilts into a long-range ferroelectric matrix in a sodium niobate based complex relaxor

In this study, we have investigated the temperature dependence of atomic ordering at multiple length scales in a lead-free sodium niobate-based relaxor, i.e., 0.75 NaNbO 3 -0.25 Ba 0.9⁢ Ca 0.1⁢ TiO 3 (NN-25BCT) via synchrotron x-ray diffraction, Raman spectroscopy, and pair distribution function analysis. High-resolution synchrotron x-ray powder diffraction (SXRD) measurements reveal a ferroelectric phase transition in the relaxor ferroelectric NN-25BCT below the Vogel-Fulcher freezing temperature (𝑇 VF ≈ 270 K). In addition, SXRD analysis demonstrates the competition between in-phase octahedral tilting and ferroelectric order at the long-range scale using mode crystallography. On the other hand, Raman spectroscopic analysis provides evidence of polar ordering for 𝑇 > 𝑇 VF (with tetragonal symmetry) persisting up to the Burns temperature (𝑇 B ). Furthermore, pair distribution function (PDF) analysis reveals the presence of a polar antiferrodistortive tetragonal phase with 𝑃⁢4⁢𝑏𝑚 space group at short ranges throughout the studied temperatures (i.e., 110 K ≤ 𝑇 ≤500 K), irrespective of nonpolar long-range ordering above 𝑇 VF . Therefore, our measurements provide direct evidence for the presence of polar ordering at short ranges and their gradual transformation into long-range polar ordering using an integrated multiscale structural analysis. In conclusion, as a result of a transition from relaxor to a ferroelectric phase in the vicinity of room temperature, NN-25BCT can be exploited for applications in pyroelectric detectors, electrocaloric devices, and multilayered ceramic capacitors.

36 MATERIALS SCIENCE↗

Visualization of Thermal and Strain Dynamics in X-ray Optics by Time-Resolved Rocking Curve Imaging

The absorption of intense X-ray pulses from free-electron lasers by X-ray crystal optics triggers rapid thermal and mechanical responses, including lattice compression, expan- sion, and strain-wave propagation, which dynamically modify diffraction conditions and wavefront properties. These effects pose significant challenges for next-generation high- repetition-rate X-ray sources, particularly for crystal monochromators used in XFEL beam- lines and self-seeding. Here, we demonstrate time-resolved rocking curve imaging (TrRCI) of X-ray Bragg optics with high spatial resolution (6.4 μm) and sub-1-μrad angular resolu- tion, enabling direct visualization of lattice dynamics from nanoseconds to microseconds. By combining a high-flux beamline at SPring-8, a scintillator-coupled sCMOS detector, and a synchronized femtosecond laser system, we capture lattice dynamics induced by tran- sient laser heating with a strain sensitivity on the order of 10−6 . Our results reveal transient lattice deformation and the propagation of laser-induced strain waves over millimeter-scale distances. This approach provides experimental benchmarks for understanding heat-load effects in high-repetition-rate X-ray optics.

Source record↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

Correlation of Processing and Structure in an Ethylene‐Glycol Side‐Chain Modified Polythiophene via Combined X‐Ray Scattering and 4D Scanning Transmission Electron Microscopy

The results of a combined grazing incidence wide-angle X-ray scattering (GIWAXS) and 4D scanning transmission microscopy (4D-STEM) analysis of the effects of thermal processing on poly(3[2-(2-methoxyethoxy)ethoxy]-methylthiophene-2,5-diyl) are reported, a conjugated semiconducting polymer used as the active layer in organic electrochemical transistor devices. GIWAXS provides a measure of overall crystallinity in the film, while 4D-STEM produces real-space maps of the morphology and orientation of individual crystallites along with their spatial extent and distribution. The sensitivity of the 4D-STEM detector allows for collection of electron diffraction patterns at each position in an image scan while limiting the imparted electron dose to below the damage threshold. In conclusion, the effects of heat treatment on the distribution and type of crystallites present in the films is determined.

36 MATERIALS SCIENCE↗

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)↗

DENNIS: a design and analysis tool for dynamic material x-ray diffraction experiments

We present DENNIS (Diffraction Experiment desigN and aNalysiS): a graphical software tool useful for the design and analysis of dynamic x-ray diffraction experiments, such as those performed on the Z Pulsed Power Facility, Thor Pulsed Power Generator, and Dynamic Compression Sector (DCS) of the Advanced Photon Source. DENNIS provides rapid powder and single-crystal diffraction pattern predictions and powder diffraction pattern image integration in three-dimensional geometries. Additional features include crystallographic information file reading, image processing, and synthetic diffraction pattern image generation. We overview the software's capabilities, detail the prediction and integration methodologies, and provide example implementations on Z and DCS experiments.

47 OTHER INSTRUMENTATION↗

A structural analysis of ordered Cs3Sb films grown on single crystal graphene and silicon carbide substrates

Alkali antimonides are well established as high efficiency, low intrinsic emittance photocathodes for accelerators and photon detectors. However, conventionally grown alkali antimonide films are polycrystalline with surface disorder and roughness that can limit achievable beam brightness. Ordering the crystalline structure of alkali antimonides has the potential to deliver higher brightness electron beams by reducing surface disorder and enabling the engineering of material properties at the level of atomic layers. In this report, we demonstrate the growth of ordered Cs3Sb films on single crystal substrates 3C-SiC and graphene-coated 4H-SiC using pulsed laser deposition and conventional thermal evaporation growth techniques. The crystalline structures of the Cs3Sb films were examined using reflection high energy electron diffraction and x-ray diffraction diagnostics, while film thickness and roughness estimates were made using x-ray reflectivity. With these tools, we observed ordered domains in less than 10 nm thick films with quantum efficiencies greater than 1% at 530 nm. Moreover, we identify structural features such as Laue oscillations indicative of highly ordered films. We found that Cs3Sb films grew with flat, fiber-textured surfaces on 3C-SiC and with multiple ordered domains and sub-nanometer surface roughness on graphene-coated 4H-SiC under our growth conditions. We identify the crystallographic orientations of Cs3Sb grown on graphene-coated 4H-SiC substrates and discuss the significance of examining the crystal structure of these films for growing epitaxial heterostructures in future experiments.

36 MATERIALS SCIENCE↗

Taking three-dimensional x-ray diffraction (3DXRD) from the synchrotron to the laboratory scale

Three-dimensional x-ray diffraction (3DXRD), a rotating x-ray diffraction technique, is a powerful tool for studying the micromechanical behavior of polycrystalline materials, capable of measuring the volume, position, orientation, and strain of thousands of grains simultaneously. However, its application has been historically limited to synchrotron facilities. Here, we present the first demonstration of laboratory-scale 3DXRD (Lab-3DXRD) using a liquid-metal-jet source. Lab-3DXRD achieves accuracy comparable to synchrotron-based 3DXRD, as validated against laboratory diffraction contrast tomography (LabDCT) and synchrotron-3DXRD. Over 96% of the grains detected with Lab-3DXRD are cross-validated, particularly for coarse grains (> ~60 μm), while the results suggest that finer grains should be accessible by taking advantage of high-efficiency detectors. We further demonstrate that its sensitivity to finer grains is enhanced by incorporating pre-characterization into the analysis. This study establishes Lab-3DXRD as a practical alternative to synchrotron techniques, making 3DXRD accessible to a wider range of academic and industrial researchers.

characterization and analytical techniques↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Harmonic Generation Seeding Echo-Enabled Harmonic Generation toward a Storage Ring-Based Tender and Hard X-ray-Free Electron Laser

To align with the global trend of integrating synchrotron light source (SLS) and free electron laser (FEL) facilities on one site, in line with examples such as SPring-8 and SACLA in Japan and ELETTRA and FERMI in Italy, we actively explore FEL options leveraging the ultralow-emittance electron beam of the NSLS-II upgrade. These options show promising potential for synergy with storage ring (SR) operations, thereby significantly enhancing our facility’s capabilities. Echo-enabled harmonic generation (EEHG) is well-suited to SR-based FELs, and has already been demonstrated with the capability of generating extremely narrow bandwidth as well as high brightness, realized using diffraction-limited short pulses in transverse planes and Fourier transform-limited bandwidth in the soft X-ray spectrum. However, regarding a conventional EEHG scheme, the combination of the shortest seed laser wavelength (256 nm) and highest harmonic (200) sets the short wavelength limit to λ = 1.28 nm. To further extend the short wavelength limit down to the tender and hard X-ray region, a vital option is to shorten the seed laser wavelength. Thanks to recent advances in high harmonic generation (HHG), packing 10 9 photons at one harmonic within a few-femtosecond pulse could turn such a novel HHG source into an ideal seeding for EEHG. Thus, compared to the cascaded EEHG, the HHG seeding option could not only lower the cost, but also free the SR space for accommodating more user beamlines. Moreover, to mitigate the SASE background noise on the sample and detector, we combine the HHG seeding EEHG with the crab cavity short pulse scheme for maximum benefit.

36 MATERIALS SCIENCE↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

Molecular beam epitaxy of superconducting zirconium nitride on GaN substrates

Epitaxial integration of metals and semiconductors can enable enhanced performance and novel functionality. Achieving such pristine interfaces with superconducting materials is of increasing interest for quantum devices and detectors, but the experimental demonstration remains challenging, given the very limited studies on single crystalline systems. To expand the potential materials for these systems, this work explores the deposition of zirconium nitride superconducting thin films on GaN substrates at various temperatures using molecular beam epitaxy. A general trend of decreasing superconducting critical temperature is observed as the deposition temperature is reduced. The optical properties reveal a transition from metallic to dielectric behavior with colder deposition. The plasma frequency of the metallic films is also observed to be a function of growth temperature. These results pave the way for the integration of a highly tunable metal nitride with a well-established semiconductor system.

36 MATERIALS SCIENCE↗

AUTOIGNITION DELAY TIMES FOR REFORMATE GAS MIXTURES FROM METHANE GAS ENGINES

Methane slip is a prominent issue in natural gas reciprocating engines that are used in transportation and marine applications. The incomplete combustion that results in methane slip can be resolved with the introduction of hydrogen within the combustion mixture to improve methane oxidation and further enable combustion within the engine crevices where methane has previously remained unreacted. Steam methane reforming (SMR) is a common method used to produce hydrogen and can be used to design an onboard device to reduce methane slip from reciprocating engines. The development of this reformer device requires the validation of high-fidelity chemical kinetic models at the low temperatures of the crevice volumes of these engines. In this work, auto-ignition data is obtained using a shock tube at lean (φ—0.714 or λ—1.4) and stoichiometric (φ, λ = 1) equivalence ratios spanning a temperature range of 1042–1234 K at the 80-bar operating pressure of the test engine. Blends of methane, hydrogen, and reformate products from the SMR reaction are shock-heated in synthetic air, with the ignition delay time measured using an OH* chemiluminescence detector at 310 nm and a CH* detector at 430 nm. The experimental results are compared to several state-of-the-art chemical kinetic mechanisms from the literature. In general, most of the mechanisms show very good agreement with experiments at higher temperatures, with simulation results showing little deviation from experiments at lower temperatures. A sensitivity analysis was conducted, and the results reveal that the reaction H2 + CH3O2 = H + CH3O2H has a very significant role in determining low-temperature ignition delay times (IDTs) of SMR mixtures. These findings provide valuable insights into the chemical kinetics governing methane reformate combustion and contribute to the optimization of onboard reformer designs aimed at mitigating methane slip in natural gas-fueled engines.

Fraze, Matthew↗

Adaptively coupled phase retrieval in multi-peak Bragg coherent diffraction imaging

Recent advances in Bragg coherent diffraction imaging (BCDI) experimental techniques permit routine measurement of multiple Bragg peaks from a single crystalline grain. The resulting images contain the full lattice distortion vector field which can be differentiated to provide lattice strain and rotation. With the advent of fourth-generation synchrotron light sources, such multi-peak datasets are produced at high rates, facilitating the need for rapid phase retrieval of the multiple peaks and subsequent image analysis. Here we describe and demonstrate a new implementation of a coupled phase retrieval technique for multi-peak BCDI which simultaneously treats each Bragg peak of the dataset and produces a three-dimensional image of the crystal's morphology and lattice distortion field. In addition, this method uses the redundant information contained in the various Bragg diffraction patterns to detect and suppress spurious signal appearing on the detector in a subset of the measurements. Compared with manual data editing, adaptive coupling produces a more consistent phase profile in reciprocal space and sharper surfaces in direct space, with no significant difference in computational cost. These improvements reduce the need for manual preprocessing and enable robust high-throughput analysis of multi-peak BCDI data, supporting near-real-time strain microscopy at modern synchrotron facilities.

36 MATERIALS SCIENCE↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗