Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analytical Method Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

A HPLC method for the quantification of butyramide and acetamide at ppb levels in hydrogeothermal waters

A quantitative analytical method to determine butyramide and acetamide concentrations at the low ppb levels in geothermal waters has been developed. The analytes are concentrated in a preparation step by evaporation and analyzed using HPLC-UV. Chromatographic separation is achieved isocratically with a RP C-18 column using a 30 mM phosphate buffer solution with 5 mM heptane sulfonic acid and methanol (98:2 ratio) as the mobile phase. Absorbance is measured at 200 nm. The limit of detection (LOD) for BA and AA were 2.0 {mu}g L{sup -1} and 2.5 {mu}g L{sup -1}, respectively. The limit of quantification (LOQ) for BA and AA were 5.7 {mu}g L{sup -1} and 7.7 {mu}g L{sup -1}, respectively, at the detection wavelength of 200 nm. Attaining these levels of quantification better allows these amides to be used as thermally reactive tracers in low-temperature hydrogeothermal systems.

10 SYNTHETIC FUELS↗

A Poisson equation method for prescribing fully developed non-Newtonian inlet conditions for computational fluid dynamics simulations in models of arbitrary cross-section

Prescribing inlet boundary conditions for computational fluid dynamics (CFD) simulations of internal flow in complex geometries such as anatomical vascular models is challenging. In the absence of patient-specific inlet velocity data, a common approach for long blood vessels is to assume that the inlet flow is fully developed. In vessels of irregular cross section, however, prescribing fully developed conditions is complicated due to the lack of a general closed-form analytical solution. In this study, we develop a simple Poisson equation method for prescribing fully developed inlet conditions for the flow of either Newtonian or non-Newtonian fluids in CFD models of arbitrary cross-section. We first derive the generalized Poisson equation for fully developed flow of a non-Newtonian fluid and we then develop and verify a methodology for numerically computing the solution on any planar boundary domain. In addition, we develop a simple extension of the method for prescribing a non-orthogonal inlet velocity that represents fully developed flow from an upstream tube that is connected to the CFD inlet at a non-orthogonal angle. This may be used to investigate a common source of uncertainty in CFD simulations of internal flow that is due to a lack of information concerning the exact streamwise flow direction at the inlets. Comparison to several Newtonian and non-Newtonian benchmark verification solutions shows the method to be extremely accurate. As a practical demonstration case, we use the method to prescribe fully developed conditions on multiple non-circular inlets for the non-Newtonian flow of blood in a patient-specific model of the inferior vena cava (IVC). Finally, we further demonstrate the utility of the method by performing a sensitivity study using the patient-specific IVC model, wherein we investigate the influence of inlet velocity flow direction on the non-Newtonian IVC hemodynamics. Given its simplicity and computational efficiency, the method is shown to be far superior to alternative approaches for prescribing fully developed inlet conditions in such complicated geometries. In conclusion, to facilitate the adoption of our Poisson equation method, we have distributed our OpenFOAM source code and the associated test cases from this study as open-source software.

97 MATHEMATICS AND COMPUTING↗

Analytical Modeling of a Double-Sided Flux Concentrating E-Core Transverse Flux Machine with Pole Windings

In this paper, a nonlinear analytical model based on the Magnetic Equivalent Circuit (MEC) method is developed for a double-sided E-Core Transverse Flux Machine (TFM). The proposed TFM has a cylindrical rotor, sandwiched between E-core stators on both sides. Ferrite magnets are used in the rotor with flux concentrating design to attain high airgap flux density, better magnet utilization, and higher torque density. The MEC model was developed using a series-parallel combination of flux tubes to estimate the reluctance network for different parts of the machine including air gaps, permanent magnets, and the stator and rotor ferromagnetic materials, in a two-dimensional (2-D) frame. An iterative Gauss-Siedel method is integrated with the MEC model to capture the effects of magnetic saturation. A single phase, 1 kW, 400 rpm E-Core TFM is analytically modeled and its results for flux linkage, no-load EMF, and generated torque, are verified with Finite Element Analysis (FEA). The analytical model significantly reduces the computation time while estimating results with less than 10 percent error.

30 DIRECT ENERGY CONVERSION↗

A note on the cylindrical solitary waves in an electron-acoustic plasma with vortex electron distribution

In the present work, we consider the propagation of nonlinear electron-acoustic non-planar waves in a plasma composed of a cold electron fluid, hot electrons obeying a trapped/vortex-like distribution, and stationary ions. The basic nonlinear equations of the above described plasma are re-examined in the cylindrical coordinates through the use reductive perturbation method in the long-wave approximation. The modified cylindrical Korteweg-de Vries equation with fractional power nonlinearity is obtained as the evolution equation. Due to the nature of nonlinearity, which is fractional, this evolution equation cannot be reduced to the conventional Korteweg–de Vries equation. An analytical solution to the evolution equation, by use of the method developed by Demiray [Appl. Math. Comput. 132, 643 (2002); Comput. Math. Appl. 60, 1747 (2010)] and a numerical solution by employing a spectral scheme are presented and the results are depicted in a figure. The numerical results reveal that both solutions are in good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advancing lightweight mirror design: a paradigm shift in mirror preforms by utilizing design for additive manufacturing

Additive manufacturing is a disruptive technology that can be leveraged by the redesign of components in most engineering fields. Fundamental engineering resources for lightweight mirrors were developed more than 30 years ago with a main design limitation, state of the art manufacturing. In this study, we present two design methodologies for the design of lightweight mirrors. The first method utilizes analytical expressions to design a traditional isogrid mirror, which provided the foundation for most lightweight mirrors to date. The second method employs a combination of topology optimization, lattice infill, and analytical estimation to develop an advanced lightweight mirror designed for additive manufacturing. The advanced mirror design outperforms the traditional design for each functional requirement, including a 94% reduction in predicted surface quilting and a higher specific stiffness. The manufacturing of the advanced mirror is only possible with an additive manufacturing process.

36 MATERIALS SCIENCE↗

Comparison of Laboratory Analytical Methods for Uranium Analysis Superior Steel FUSRAP Site - 16606

The Superior Steel Site processed uranium metal in support of the Atomic Energy Commission's fuel-element development program in the 1950's, and was subsequently classified as a Formerly Utilized Sites Remedial Action Program (FUSRAP) Site. Previous investigations at the site identified uranium contamination both inside and outside the buildings associated with historic uranium metalworking activities. The U.S. Army Corps of Engineers (USACE) is currently engaged in the Remedial Investigation (RI) phase in accordance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980, as amended. As part of the RI, gamma spectroscopy analysis of environmental samples was performed on-site using a laboratory-grade, high-purity germanium (HPGe) spectrometer. The gamma spectroscopy analysis included isotopes of uranium and their progeny. As a quality assurance measure, a subset of samples already analyzed on-site were sent to a certified, commercial, off-site laboratory for analysis using a suite of analytical methods including gamma spectroscopy, alpha spectroscopy, and mass spectroscopy. As an element of the quality assurance program implemented for the RI, an assessment of the correlations between the various analytical methods employed by both the on-site and off-site laboratory was performed. This assessment revealed inconsistencies between on-site and off-site gamma spectroscopy analytical results, which raised concerns about the appropriateness and suitability of the analytical data. To resolve the data quality concerns and better understand the source(s) of analytical results variability, the Superior Steel RI team (USACE together with its contractor, Amec Foster Wheeler) developed a quality control test whose design objective was to control or practically eliminate sampling and sample preparation variability in order to focus more clearly on analytical variability. This paper discusses the results of this supplemental quality control test, showing the differences in the various analytical methods (both on-site and off-site). It demonstrates in a practical and real world setting how sample preparation and analytical variability, if not controlled and understood can impact data quality and data defensibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Theoretical understanding of photon spectroscopies in correlated materials in and out of equilibrium

Photon-based spectroscopies have had a significant impact on both fundamental science and applications by providing an efficient approach to investigate the microscopic physics of materials. Together with the development of synchrotron X-ray techniques, theoretical understanding of the spectroscopies themselves and the underlying physics that they reveal has progressed through advances in numerical methods and scientific computing. In this Review, we provide an overview of theories for angle-resolved photoemission spectroscopy and resonant inelastic X-ray scattering applied to quantum materials. First, we discuss methods for studying equilibrium spectroscopies, including first-principles approaches, numerical many-body methods and a few analytical advances. Second, we assess the recent development of ultrafast techniques for out-of-equilibrium spectroscopies, from characterizing equilibrium properties to generating transient or metastable states, mainly from a theoretical point of view. Lastly, we identify the main challenges and provide an outlook for the future direction of the field.

36 MATERIALS SCIENCE↗

Ontology-Enriched Specifications Enabling Findable, Accessible, Interoperable, and Reusable Marine Metagenomic Datasets in Cyberinfrastructure Systems

Marine microbial ecology requires the systematic comparison of biogeochemical and sequence data to analyze environmental influences on the distribution and variability of microbial communities. With ever-increasing quantities of metagenomic data, there is a growing need to make datasets Findable, Accessible, Interoperable, and Reusable (FAIR) across diverse ecosystems. FAIR data is essential to developing analytical frameworks that integrate microbiological, genomic, ecological, oceanographic, and computational methods. Although community standards defining the minimal metadata required to accompany sequence data exist, they haven’t been consistently used across projects, precluding interoperability. Moreover, these data are not machine-actionable or discoverable by cyberinfrastructure systems. By making ‘omic and physicochemical datasets FAIR to machine systems, we can enable sequence data discovery and reuse based on machine-readable descriptions of environments or physicochemical gradients. In this work, we developed a novel technical specification for dataset encapsulation for the FAIR reuse of marine metagenomic and physicochemical datasets within cyberinfrastructure systems. This includes using Frictionless Data Packages enriched with terminology from environmental and life-science ontologies to annotate measured variables, their units, and the measurement devices used. This approach was implemented in Planet Microbe, a cyberinfrastructure platform and marine metagenomic web-portal. Here, we discuss the data properties built into the specification to make global ocean datasets FAIR within the Planet Microbe portal. We additionally discuss the selection of, and contributions to marine-science ontologies used within the specification. Finally, we use the system to discover data by which to answer various biological questions about environments, physicochemical gradients, and microbial communities in meta-analyses. This work represents a future direction in marine metagenomic research by proposing a specification for FAIR dataset encapsulation that, if adopted within cyberinfrastructure systems, would automate the discovery, exchange, and re-use of data needed to answer broader reaching questions than originally intended.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging MS Methodology for More Chemical Information in Less Data Acquisition Time Utilizing a Hybrid Linear Ion Trap-Orbitrap Mass Spectrometer

A novel mass spectrometric imaging method is developed to reduce the data acquisition time and provide rich chemical information using a hybrid linear ion trap-orbitrap mass spectrometer. In this method, the linear ion trap and orbitrap are used in tandem to reduce the acquisition time by incorporating multiple linear ion trap scans during an orbitrap scan utilizing a spiral raster step plate movement. The data acquisition time was decreased by 43-49% in the current experiment compared to that of orbitrap-only scans; however, 75% or more time could be saved for higher mass resolution and with a higher repetition rate laser. Using this approach, a high spatial resolution of 10 {micro}m was maintained at ion trap imaging, while orbitrap spectra were acquired at a lower spatial resolution, 20-40 {micro}m, all with far less data acquisition time. Furthermore, various MS imaging methods were developed by interspersing MS/MS and MSn ion trap scans during orbitrap scans to provide more analytical information on the sample. This method was applied to differentiate and localize structural isomers of several flavonol glycosides from an Arabidopsis flower petal in which MS/MS, MSn, ion trap, and orbitrap images were all acquired in a single data acquisition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis of boron nitride nanotubes with SiC nanowire as template

Highlights: {yields} Boron nitride nanotubes (BNNTs) have been fabricated using SiC nanowires as template. {yields} SiC nanowires could be effectively etched out by the vapors decomposed from ammonia borane, leading to the formation of BNNTs. {yields} A template self-sacrificing mechanism is responsible for the formation of BNNTs. -- Abstract: A novel template method for the preparation of boron nitride nanotubes (BNNTs) using SiC nanowire as template and ammonia borane as precursor is reported. We find out that the SiC nanowires could be effectively etched out by the vapors decomposed from ammonia borane, leading to the formation of BNNTs. The as-prepared products are well characterized by means of complementary analytical techniques. A possible formation mechanism is disclosed. The method developed here paves the way for large scale production of BNNTs.

36 MATERIALS SCIENCE↗

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

Atomic-scale characterization of (electro-)catalysts and battery materials by atom probe tomography

To optimise the performance of heterogeneous (electro-)catalysts and battery electrodes, it is essential to establish the structure-property relationships. This can only be achieved by obtaining a full three-dimensional (3D) characterisation of atomic-scale structure and chemistry of these advanced materials. Atom probe tomography (APT) can provide unique insights into 3D elemental distribution, including low atomic mass elements, with sub-nanometer spatial resolution. Despite its superior chemical analytical capability and spatial resolution, APT has limited applications for sustainable energy materials due to technical and analytical challenges. The recent developments in experimental setups, sample preparation methods and data analysis algorithms have opened the door to the possibility of analysing heterogeneous (electro-)catalysts and battery electrodes. This perspective provides an overview of these developments, exemplified by recent achievements of analyzing model heterogeneous model (electro-)catalysts, nanoparticles, zeolites, MOFs and Li-ion battery electrodes, followed by a discussion of limitations, opportunities, and potentials of APT for future scientific exploration.

atom probe tomography↗

A theoretical study of the upper bound of surface elevation variance in the Phillips initial stage during wind-wave generation

The resonance mechanism in the initial of wind-wave generation proposed by Phillips is a foundation of wind-wave generation theory, but a precise theoretical quantification of wave energy growth in this initial stage has not been obtained yet after more than six decades of research. In this study, we aim to address this knowledge gap by developing an analytical approach based on a novel complex analysis method to theoretically investigate the temporal evolution of the wave energy in the Phillips initial stage. We quantitatively derive and analyse the growth behaviour of the surface wave energy and obtain an analytical solution for its upper bound. Our result highlights the crucial effects of surface tension. Because the phase velocity of gravity–capillary waves has a minimal value at a critical wavenumber, gravity–capillary waves and gravity waves (which neglect surface tension) exhibit distinct resonance curve properties and wave energy growth behaviours. For gravity waves, the resonance curve extends indefinitely; for gravity–capillary waves, it either forms a finite-length curve or does not exist, depending on the wind speed. The leading-order term of the upper-bound solution of the energy of gravity waves increases linearly over time, while for gravity–capillary waves, the term increases linearly over time under strong wind conditions but remains finite under weak wind conditions. This theoretical study provides an analytical framework for the generation of wind-waves in the Phillips initial stage, which may inspire further theoretical, numerical and experimental research.

58 GEOSCIENCES↗

Surface Modification of Silicon Pillar Arrays To Enhance Fluorescence Detection of Uranium and DNA

There is an ever-growing need for detection methods that are both sensitive and efficient, such that reagent and sample consumption is minimized. Nanopillar arrays offer an attractive option to fill this need by virtue of their small scale in conjunction with their field enhancement intensity gains. This work investigates the use of nanopillar substrates for the detection of the uranyl ion and DNA, two analytes unalike but for their low quantum efficiencies combined with the need for high-throughput analyses. Here in this paper, the adaptability of these platforms was explored, as methods for the successful surface immobilization of both analytes were developed and compared, resulting in a limit of detection for the uranyl ion of less than 1 ppm with a 0.2 μL sample volume. Moreover, differentiation between single-stranded and double-stranded DNA was possible, including qualitative identification between double-stranded DNA and DNA of the same sequence, but with a 10-base-pair mismatch.

36 MATERIALS SCIENCE↗

Signal, Noise and Resolution in Linear and Nonlinear Structured-Illumination Microscopy

Structured-illumination microscopy allows widefield fluorescence imaging with resolution beyond the classical diffraction limit. Its linear form extends resolution by a factor of two, and its nonlinear form by an in-principle infinite factor, the effective resolution in practice being determined by noise. In this article, we analyze the noise properties and achievable resolution of the method from a frequency-space perspective. We develop an analytical theory for a general case of linear or nonlinear fluorescent imaging, and verify the analytical calculations with numerical simulation for a special case where nonlinearity is produced by photo-switching of fluorescent labels. We compare the performance of two alternative implementations, using either two-dimensional illumination patterns or sequentially rotated one-dimensional patterns. We show that one-dimensional patterns are advantageous in the linear case, and that in the nonlinear case two-dimensional patterns provide a slight signal-to-noise advantage under idealized conditions, but perform worse than one-dimensional patterns in the presence of non-switchable fluorescent background.

99 GENERAL AND MISCELLANEOUS↗

Define and Quantify the Physics of Air Flow, Pressure Drop and Aerosol Collection in Nuclear Grade HEPA Filters

Objective: Develop a set of peer-review and verified analytical methods to adjust HEPA filter performance to different flow rates, temperatures and altitudes. Experimental testing will measure HEPA filter flow rate, pressure drop and efficiency to verify the analytical approach. Nuclear facilities utilize HEPA (High Efficiency Particulate Air) filters to purify air flow for workspace ventilation. However, the ASME AG-1 technical standard (Code on Nuclear Air and Gas Treatment) does not adequately describe air flow measurement units for HEPA filter systems. Specifically, the AG-1 standard does not differentiate between volumetric air flow in ACFM (actual cubic feet per minute)compared to mass flow measured in SCFM (standard cubic feet per minute). More importantly, the AG-1 standard has an overall deficiency for using HEPA filter devices at different air flow rates, temperatures, and altitudes. Technical Approach: The collection efficiency and pressure drops of 18 different HEPA filters will be measured over a range of flow rates, temperatures and altitudes. The experimental results will be compared to analytical scoping calculations. Three manufacturers have allocated six HEPA filters each for this effort. The 18 filters will be tested at two different flow rates, two different temperatures and two different altitudes. The 36 total tests will be conducted at two different facilities: the ATI Test facilities (Baltimore MD) and the Los Alamos National Laboratory (Los Alamos NM). The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally designed to evaluate small air samplers. In 2010, modifications were started to convert the wind tunnel for HEPA filter testing. (Extensive changes were necessary for the required aerosol generators, HEPA test fixtures, temperature control devices and measurement capabilities.) To this date, none of these modification activities have been funded through a specific DOE or NNSA program. This is expected to require six months of time, after receipt of funding. Benefits: US DOE facilities that use HEPA filters will benefit from access to the new operational measurement methods. Uncertainty and guesswork will be removed from HEPA filter operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

CRADA Final Report: Weld Predictor App

Welding is an important manufacturing process used in a broad range of industries and market sectors, including automotive, aerospace, heavy manufacturing, medical, and defense. During welded fabrication, high localized heat input and subsequent rapid cooling result in the creation of residual stresses and distortion. These residual stresses can significantly affect the fatigue resistance, cracking behavior, and load-carrying capacity of welded structures during service. Further, additional fitting and tacking time is often required to fit distorted subassemblies together, resulting in non-value added cost. Using trial-and-error methods to determine which welding parameters, welding sequences, and fixture designs will most effectively reduce distortion is a time-consuming and expensive process. For complex structures with many welds, this approach can take several months. For this reason, efficient and accurate methods of mitigating distortion are in-demand across all industries where welding is used. Analytical and computational methods and commercial software tools have been developed to predict welding-induced residual stresses and distortion. Welding process parameters, fixtures, and tooling can be optimized to reduce the HAZ softening and minimize weld residual stress and distortion, improving performance and reducing design, fabrication and testing costs. However, weld modeling technology tools are currently accessible only to engineers and designers with a background in finite element analysis (FEA) who work with large manufacturers, research institutes, and universities with access to high-performance computing (HPC) resources. Small and medium enterprises (SMEs) in the US do not typically have the human and computational resources needed to adopt and utilize weld modeling technology. To allow an engineer with no background in FEA and SMEs to gain access to this important design tool, EWI and the Ohio Supercomputer Center (OSC) developed the online weld application software tool “WeldPredictor” ( https://eweldpredictor.ewi.org ). About 1400 users have tested this application. This project marked the beginning of development on the next version of WeldPredictor that addresses many outstanding features of the original, including 3D models, allow more material hardening laws, model material phase transformation, and uses open source finite element solvers to quickly solve problems (as opposed to expensive commercial tools).

42 ENGINEERING↗