Calibration and Laboratory Test of the Department of Energy Cloud Particle Imager

Calibration parameters from the Connolly et al. (2007) algorithm cannot be applied to the Department of Energy's (DOE) CPI because the DOE CPI is version 2.0. Thus, Dr. Junshik Um and Prof. Greg McFarquhar brought the DOE CPI to the University of Manchester, UK, where facilities for calibrating it were available. In addition, two other versions of CPIs (1.0 and 1.5) were available on-site at the University of Manchester so that an intercomparison of three different versions of the CPI was possible. The three CPIs (versions 1.0, 1.5, and 2.0) were calibrated by moving glass calibration beads and ice analogues of known size parallel to the object plane. The distance between the object plane and a particle, the particle's focus, its apparent maximum dimension, and a background image were measured in order to derive calibration parameters for each CPI version. The calibration parameters are used in two empirical equations that are applied to in situ CPI data to determine particle size and depth of field, and hence particle size distributions (PSDs). After the tests with the glass calibration beads to derive the calibration parameters, the three CPIs were installed at the base of the Manchester Ice Cloud Chamber and connected to air pumps that drew cloud through the sample volume. Warm liquid clouds at a temperature of 1-2 C and ice clouds at a temperature of -5 C were generated, and the resulting PSDs for each of the CPIs were determined by applying the results of each calibration.

99 GENERAL AND MISCELLANEOUS↗

Validation and Calibration of Nuclear Thermal Hydraulics Multiscale Multiphysics Models - Subcooled Flow Boiling Study

In addition to validation data plan, development of advanced techniques for calibration and validation of complex multiscale, multiphysics nuclear reactor simulation codes are a main objective of the CASL VUQ plan. Advanced modeling of LWR systems normally involves a range of physico-chemical models describing multiple interacting phenomena, such as thermal hydraulics, reactor physics, coolant chemistry, etc., which occur over a wide range of spatial and temporal scales. To a large extent, the accuracy of (and uncertainty in) overall model predictions is determined by the correctness of various sub-models, which are not conservation-laws based, but empirically derived from measurement data. Such sub-models normally require extensive calibration before the models can be applied to analysis of real reactor problems. This work demonstrates a case study of calibration of a common model of subcooled flow boiling, which is an important multiscale, multiphysics phenomenon in LWR thermal hydraulics. The calibration process is based on a new strategy of model-data integration, in which, all sub-models are simultaneously analyzed and calibrated using multiple sets of data of different types. Specifically, both data on large-scale distributions of void fraction and fluid temperature and data on small-scale physics of wall evaporation were simultaneously used in this work’s calibration. In a departure from traditional (or common-sense) practice of tuning/calibrating complex models, a modern calibration technique based on statistical modeling and Bayesian inference was employed, which allowed simultaneous calibration of multiple sub-models (and related parameters) using different datasets. Quality of data (relevancy, scalability, and uncertainty) could be taken into consideration in the calibration process. This work presents a step forward in the development and realization of the “CIPS Validation Data Plan” at the Consortium for Advanced Simulation of LWRs to enable quantitative assessment of the CASL modeling of Crud-Induced Power Shift (CIPS) phenomenon, in particular, and the CASL advanced predictive capabilities, in general. This report is prepared for the Department of Energy’s Consortium for Advanced Simulation of LWRs program’s VUQ Focus Area.

97 MATHEMATICS AND COMPUTING↗

Mercury Calibration System

U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on actual capabilities of the current calibration technology. As part of the current effort, WRI worked with Thermo Fisher elemental mercury calibrator units to conduct qualification experiments to demonstrate their performance characteristics under a variety of conditions and to demonstrate that they qualify for use in the CEM calibration program. Monitoring of speciated mercury is another concern of this research. The mercury emissions from coal-fired power plants are comprised of both elemental and oxidized mercury. Current CEM analyzers are designed to measure elemental mercury only. Oxidized mercury must first be converted to elemental mercury prior to entering the analyzer inlet in order to be measured. CEM systems must demonstrate the ability to measure both elemental and oxidized mercury. This requires the use of oxidized mercury generators with an efficient conversion of the oxidized mercury to elemental mercury. There are currently two basic types of mercuric chloride (HgCl{sub 2}) generators used for this purpose. One is an evaporative HgCl{sub 2} generator, which produces gas standards of known concentration by vaporization of aqueous HgCl{sub 2} solutions and quantitative mixing with a diluent carrier gas. The other is a device that converts the output from an elemental Hg generator to HgCl{sub 2} by means of a chemical reaction with chlorine gas. The Thermo Fisher oxidizer system involves reaction of elemental mercury vapor with chlorine gas at an elevated temperature. The draft interim protocol for oxidized mercury units involving reaction with chlorine gas requires the vendors to demonstrate high efficiency of oxidation of an elemental mercury stream from an elemental mercury vapor generator. The Thermo Fisher oxidizer unit is designed to operate at the power plant stack at the probe outlet. Following oxidation of elemental mercury from reaction with chlorine gas, a high temperature module reduces the mercuric chloride back to elemental mercury. WRI conducted work with a custom laboratory configured stand-alone oxidized mercury generator unit provided by Thermo Fisher to perform experiments to demonstrate the high efficiency of oxidation on reaction with chlorine gas, and reduction back to elemental mercury.

01 COAL, LIGNITE, AND PEAT↗

Mercury Calibration System

U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on actual capabilities of the current calibration technology. As part of the current effort, WRI worked with Thermo Fisher elemental mercury calibrator units to conduct qualification experiments to demonstrate their performance characteristics under a variety of conditions and to demonstrate that they qualify for use in the CEM calibration program. Monitoring of speciated mercury is another concern of this research. The mercury emissions from coal-fired power plants are comprised of both elemental and oxidized mercury. Current CEM analyzers are designed to measure elemental mercury only. Oxidized mercury must first be converted to elemental mercury prior to entering the analyzer inlet in order to be measured. CEM systems must demonstrate the ability to measure both elemental and oxidized mercury. This requires the use of oxidized mercury generators with an efficient conversion of the oxidized mercury to elemental mercury. There are currently two basic types of mercuric chloride (HgCl{sub 2}) generators used for this purpose. One is an evaporative HgCl{sub 2} generator, which produces gas standards of known concentration by vaporization of aqueous HgCl{sub 2} solutions and quantitative mixing with a diluent carrier gas. The other is a device that converts the output from an elemental Hg generator to HgCl{sub 2} by means of a chemical reaction with chlorine gas. The Thermo Fisher oxidizer system involves reaction of elemental mercury vapor with chlorine gas at an elevated temperature. The draft interim protocol for oxidized mercury units involving reaction with chlorine gas requires the vendors to demonstrate high efficiency of oxidation of an elemental mercury stream from an elemental mercury vapor generator. The Thermo Fisher oxidizer unit is designed to operate at the power plant stack at the probe outlet. Following oxidation of elemental mercury from reaction with chlorine gas, a high temperature module reduces the mercuric chloride back to elemental mercury. WRI conducted work with a custom laboratory configured stand-alone oxidized mercury generator unit provided by Thermo Fisher to perform experiments to demonstrate the high efficiency of oxidation on reaction with chlorine gas, and reduction back to elemental mercury.

01 COAL, LIGNITE, AND PEAT↗

Scalable deep learning for watershed model calibration

Watershed models such as the Soil and Water Assessment Tool (SWAT) consist of high-dimensional physical and empirical parameters. These parameters often need to be estimated/calibrated through inverse modeling to produce reliable predictions on hydrological fluxes and states. Existing parameter estimation methods can be time consuming, inefficient, and computationally expensive for high-dimensional problems. In this paper, we present an accurate and robust method to calibrate the SWAT model (i.e., 20 parameters) using scalable deep learning (DL). We developed inverse models based on convolutional neural networks (CNN) to assimilate observed streamflow data and estimate the SWAT model parameters. Scalable hyperparameter tuning is performed using high-performance computing resources to identify the top 50 optimal neural network architectures. We used ensemble SWAT simulations to train, validate, and test the CNN models. We estimated the parameters of the SWAT model using observed streamflow data and assessed the impact of measurement errors on SWAT model calibration. We tested and validated the proposed scalable DL methodology on the American River Watershed, located in the Pacific Northwest-based Yakima River basin. Our results show that the CNN-based calibration is better than two popular parameter estimation methods (i.e., the generalized likelihood uncertainty estimation [GLUE] and the dynamically dimensioned search [DDS], which is a global optimization algorithm). For the set of parameters that are sensitive to the observations, our proposed method yields narrower ranges than the GLUE method but broader ranges than values produced using the DDS method within the sampling range even under high relative observational errors. The SWAT model calibration performance using the CNNs, GLUE, and DDS methods are compared using R 2 and a set of efficiency metrics, including Nash-Sutcliffe, logarithmic Nash-Sutcliffe, Kling-Gupta, modified Kling-Gupta, and non-parametric Kling-Gupta scores, computed on the observed and simulated watershed responses. The best CNN-based calibrated set has scores of 0.71, 0.75, 0.85, 0.85, 0.86, and 0.91. The best DDS-based calibrated set has scores of 0.62, 0.69, 0.8, 0.77, 0.79, and 0.82. The best GLUE-based calibrated set has scores of 0.56, 0.58, 0.71, 0.7, 0.71, and 0.8. The scores above show that the CNN-based calibration leads to more accurate low and high streamflow predictions than the GLUE and DDS sets. Our research demonstrates that the proposed method has high potential to improve our current practice in calibrating large-scale integrated hydrologic models.

54 ENVIRONMENTAL SCIENCES↗

Photogrammetric Deflection Measurements for the Tiltrotor Test Rig (TTR) Multi-Component Rotor Balance Calibration

Calibrating the internal, multi-component balance mounted in the Tiltrotor Test Rig (TTR) required photogrammetric measurements to determine the location and orientation of forces applied to the balance. The TTR, with the balance and calibration hardware attached, was mounted in a custom calibration stand. Calibration loads were applied using eleven hydraulic actuators, operating in tension only, that were attached to the forward frame of the calibration stand and the TTR calibration hardware via linkages with in-line load cells. Before the linkages were installed, photogrammetry was used to determine the location of the linkage attachment points on the forward frame and on the TTR calibration hardware. Photogrammetric measurements were used to determine the displacement of the linkage attachment points on the TTR due to deflection of the hardware under applied loads. These measurements represent the first photogrammetric deflection measurements to be made to support 6-component rotor balance calibration. This paper describes the design of the TTR and the calibration hardware, and presents the development, set-up and use of the photogrammetry system, along with some selected measurement results.

Calibration↗

Photogrammetric Deflection Measurements for the Tiltrotor Test Rig (TTR) Multi-Component Rotor Balance Calibration

Calibrating the internal, multi-component balance mounted in the Tiltrotor Test Rig (TTR) required photogrammetric measurements to determine the location and orientation of forces applied to the balance. The TTR, with the balance and calibration hardware attached, was mounted in a custom calibration stand. Calibration loads were applied using eleven hydraulic actuators, operating in tension only, that were attached to the forward frame of the calibration stand and the TTR calibration hardware via linkages with in-line load cells. Before the linkages were installed, photogrammetry was used to determine the location of the linkage attachment points on the forward frame and on the TTR calibration hardware. Photogrammetric measurements were used to determine the displacement of the linkage attachment points on the TTR due to deflection of the hardware under applied loads. These measurements represent the first photogrammetric deflection measurements to be made to support 6-component rotor balance calibration. This paper describes the design of the TTR and the calibration hardware, and presents the development, set-up and use of the photogrammetry system, along with some selected measurement results.

Calibration↗

Evaluation of the Accuracy of the Load Prediction Equations of Low-Load Balance Calibration Data

Accuracy and reliability of the load prediction equations of a low-load calibration data set of a force balance were investigated. First, independent load prediction equations were generated from the data of a full-load and low-load machine calibration. Then, the low- load data set was processed as a set of precision check loads for the load prediction equations that were obtained from the full-load and low-load calibrations. Finally, the load prediction equations of the two calibrations were applied to four manual check load data sets that were recorded between 2009 and 2022. The residuals of the predicted calibration and check loads were compared in all cases. No systematic improvement of the load prediction accuracy was observed when the load prediction equations of the low-load calibration were applied to the check load data sets. Therefore, it is recommended to apply a full-load calibration to a six-component balance even if the balance is not used across its entire design envelope. This approach has the advantage that the resulting load prediction equations are less likely to be applied outside of the calibration load ranges. In addition, it is expected that the numerical estimates of the gage sensitivities are more reliable assuming that the uncertainties of the applied loads and measured outputs of the calibration data are more or less constant across the load range of the balance.

strain-gage balance↗

Evaluation of the Accuracy of the Load Prediction Equations of Low-Load Balance Calibration Data

Accuracy and reliability of the load prediction equations of a low-load calibration data set of a force balance were investigated. First, independent load prediction equations were generated from the data of a full-load and low-load machine calibration. Then, the low-load data set was processed as a set of precision check loads for the load prediction equations that were obtained from the full-load and low-load calibrations. Finally, the load prediction equations of the two calibrations were applied to four manual check load data sets that were recorded between 2009 and 2022. The residuals of the predicted calibration and check loads were compared in all cases. No systematic improvement of the load prediction accuracy was observed when the load prediction equations of the low-load calibration were applied to the check load data sets. Therefore, it is recommended to apply a full-load calibration to a six-component balance even if the balance is not used across its entire design envelope. This approach has the advantage that the resulting load prediction equations are less likely to be applied outside of the calibration load ranges. In addition, it is expected that the numerical estimates of the bridge sensitivities are more reliable assuming that the uncertainties of the applied loads and measured outputs of the calibration data are more or less constant across the load range of the balance.

strain-gage balance↗

Calibration of the SNPP and NOAA 20 VIIRS Sensors for Continuity of the MODIS Climate Data Records

Accurate long-term sensor calibration and periodic re-processing to ensure consistency and continuity of atmospheric, land and ocean geophysical retrievals from space within the mission period and across different missions is a major requirement of climate data records. In this work, we applied the Multi-Angle Implementation of Atmospheric Correction (MAIAC)-based vicarious calibration technique over Libya-4 desert site to perform calibration analysis of Visible Infrared Imaging Radiometer Suite (VIIRS) on Suomi National Polar-orbiting Partnership (SNPP) and NOAA-20 satellites. For both VIIRS sensors we characterized residual linear calibration trends and cross-calibrated both sensors to MODerate resolution Imaging Spectroradiometer (MODIS) Aqua regarded as a calibration standard. The relative spectral response (RSR) differences were accounted for using the German Aerospace Center (DLR) Earth Sensing Imaging Spectrometer (DESIS) hyperspectral surface reflectance data. Our results agree with independent vicarious calibration results of both the MODIS/VIIRS Characterization Support Team as well as the CERES Imager and Geostationary Calibration Group within estimated uncertainty of 1–2%. Analysis of MAIAC geophysical products with the new calibration shows a high level of agreement of MAIAC aerosol, surface reflectance and NDVI records between MODIS and VIIRS. Excluding high aerosol optical depth (AOD), all three sensors agree in AOD with mean difference (MD) less than 0.01 and residual mean squared difference rmsd ∼ 0.04. Spectral geometrically normalized surface reflectance agrees within rmsd of 0.003–0.005 in the visible and 0.01–0.012 at longer wavelengths. The residual surface reflectance differences are fully explained by differences in spectral filter functions. Finally, difference in NDVI is characterized by rmsd ∼ 0.02 and MD less than 0.003 for NDVI based on VIIRS imagery bands I1/I2 and less than 0.01 for NDVI based on VIIRS radiometric bands M5/M7. In practical sense, these numbers indicate consistency and continuity in MAIAC records ensuring the smooth transition from MODIS to VIIRS.

MAIAC↗

Beowulf - Beta-Gamma Detector Calibration Graphical User Interface

Pacific Northwest National Laboratory (PNNL) has demonstrated significant advancement in using beta-gamma coincidence detectors to detect a wide range of radioxenon isotopes. To obtain accurate activities with the detector it must be properly calibrated by measuring a series of calibration gas samples. The data is analyzed to create the calibration block used in the International Monitoring System file format. Doing the calibration manually has proven to be tedious and prone to errors, requiring a high degree of expertise. The Beowulf graphical user interface (GUI) is a software application that encompasses several components of the calibration task and generates a calibration block, as well as, a detailed report describing the specific calibration process used. This additional document can be used as a Quality assurance certificate to assist in auditing the calibration. This paper consists of two sections. Section 1 will describe the capabilities of Beowulf and section 2 will be a representative report generated or the 137Cs calibration and quality assurance source.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Self-calibration performance in stereoscopic PIV acquired in a transonic wind tunnel

Three stereoscopic PIV experiments have been examined to test the effectiveness of self-calibration under varied circumstances. Furthermore, we our measurements taken in a streamwise plane yielded a robust self-calibration that returned common results regardless of the specific calibration procedure, but measurements in the crossplane exhibited substantial velocity bias errors whose nature was sensitive to the particulars of the self-calibration approach. Self-calibration is complicated by thick laser sheets and large stereoscopic camera angles and further exacerbated by small particle image diameters and high particle seeding density. In spite of the different answers obtained by varied self-calibrations, each implementation locked onto an apparently valid solution with small residual disparity and converged adjustment of the calibration plane. Thus, the convergence of self-calibration on a solution with small disparity is not sufficient to indicate negligible velocity error due to the stereo calibration.

47 OTHER INSTRUMENTATION↗

Reduced-dimension Bayesian optimization for model calibration of transient vapor compression cycles

Development and calibration of first-principles dynamic models of vapor compression cycles (VCCs) is of critical importance for applications that include control design and fault detection and diagnostics. Nevertheless, the inherent complexity of models that are represented by large systems of differential–algebraic equations leads to significant challenges for model calibration processes that utilize classical gradient-based methods. Bayesian optimization (BO) is a sample-efficient and gradient-free approach using a probabilistic surrogate model and optimal search over a feasible parameter space. Despite the benefits of BO in reducing computational costs, challenges remain in dealing with a high-dimensional calibration task resulting from a large set of parameters that have significant impacts on system behavior and need to be calibrated simultaneously. This paper presents a reduced-dimension BO framework for calibrating transient VCCs models where the calibration space is projected to a low-dimensional subspace for accelerating convergence of the solution algorithm and consequently reducing the number of transient simulations. The proposed approach was demonstrated via two case studies associated with different VCC applications where 10 parameters were calibrated in each case using laboratory measurements. The reduced-dimension BO framework only required 1 / 8 th of the iterations associated with a standard BO method that deals with high-dimensional calibration parameters for converged solutions and yielded comparable accuracy. Furthermore, both calibrated models revealed significant accuracy improvements compared to uncalibrated models.

Ma, Jiacheng↗

SCALA: In situ calibration for integral field spectrographs

The scientific yield of current and future optical surveys is increasingly limited by systematic uncertainties in the flux calibration. This is the case for type Ia supernova (SN Ia) cosmology programs, where an improved calibration directly translates into improved cosmological constraints. Current methodology rests on models of stars. Here we aim to obtain flux calibration that is traceable to state-of-the-art detector-based calibration. Methods. We present the SNIFS Calibration Apparatus (SCALA), a color (relative) flux calibration system developed for the SuperNova integral field spectrograph (SNIFS), operating at the University of Hawaii 2.2 m (UH 88) telescope. Results. By comparing the color trend of the illumination generated by SCALA during two commissioning runs, and to previous laboratory measurements, we show that we can determine the light emitted by SCALA with a long-term repeatability better than 1%. We describe the calibration procedure necessary to control for system aging. We present measurements of the SNIFS throughput as estimated by SCALA observations. Conclusions. The SCALA calibration unit is now fully deployed at the UH 88 telescope, and with it color-calibration between 4000 Å and 9000 Å is stable at the percent level over a one-year baseline.

79 ASTRONOMY AND ASTROPHYSICS↗

Innovative methodology for intercomparison of radionuclide calibrators using short half-life in situ prepared radioactive sources

Purpose: An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as{sup 99m}Tc or most positron emission tomography radiopharmaceuticals. Methods: By evaluation of the resulting net optical density (netOD) using a standardized scanning method of irradiated Gafchromic XRQA2 film, a comparison of the netOD measurement with a previously determined calibration curve can be made and the difference between the tested radionuclide calibrator and a radionuclide calibrator used as reference device can be calculated. To estimate the total expected measurement uncertainties, a careful analysis of the methodology, for the case of{sup 99m}Tc, was performed: reproducibility determination, scanning conditions, and possible fadeout effects. Since every factor of the activity measurement procedure can influence the final result, the method also evaluates correct syringe positioning inside the radionuclide calibrator. Results: As an alternative to using a calibrated source sent to the surveyed site, which requires a relatively long half-life of the nuclide, or sending a portable calibrated radionuclide calibrator, the proposed method uses a source preparedin situ. An indirect activity determination is achieved by the irradiation of a radiochromic film using {sup 99m}Tc under strictly controlled conditions, and cumulated activity calculation from the initial activity and total irradiation time. The irradiated Gafchromic film and the irradiator, without the source, can then be sent to a National Metrology Institute for evaluation of the results. Conclusions: The methodology described in this paper showed to have a good potential for accurate (3%) radionuclide calibrators intercomparison studies for{sup 99m}Tc between Nuclear Medicine centers without source transfer and can easily be adapted to other short half-life radionuclides.

07 ISOTOPE AND RADIATION SOURCES↗

Automatic Energy Calibration of Gamma-Ray Spectrometers

The software provides automatic method for calibrating the energy scale of high-purity germanium (HPGe) and scintillation gamma-ray spectrometers, using natural background radiation as the source of calibration gamma rays. In field gamma-ray spectroscopy, radioactive check sources may not be available; temperature changes can shift detector electronic gain and scintillator light output; and a user's experience and training may not include gamma-ray energy calibration. Hence, an automated method of calibrating the spectrometer using natural background would simplify its operation, especially by technician-level users, and by enhancing spectroscopic data quality, it would reduce false detections. Following a typically one-minute count of background gamma-rays, the measured spectrum is searched for gamma-ray peaks, producing a list of peak centroids, in channels1. Next, the ratio algorithm attempts to match the peak centroids found in the search to a user-supplied list of calibration gamma-ray energies. Finally, if three or more calibration energies have been matched to peaks, the energy equation parameters are determined by a least-squares fit2, and the spectrum has been energy-calibrated. The ratio algorithm rests on the repeatable but irregular spacing of the background gamma-ray energies together they form a unique set of ratios, when normalized to the highest energy calibration gamma ray; so too, the corresponding peak centroids in the spectrum. The algorithm matches energy ratios to peak centroid ratios, to determine which peak matches a given calibration energy.

Caffrey, Gus↗

Interlaced Characterization and Calibration (ICC) for Improved Computational Simulation Credibility

Accurate material characterization and model calibration are pivotal for simulations used for high-consequence engineering decisions. Current characterization and calibration methods (1) use simplified test specimen geometries and global data, (2) cannot guarantee that sufficient characterization data is collected for a specific model of interest, (3) provide only mean parameter values with no uncertainty quantification, and (4) are sequential, inflexible, and time-consuming. This work developed a new paradigm—coined Interlaced Characterization and Calibration (ICC)—which drives forward the state-of-the-art in model calibration by bringing together recent advancements into one improved workflow. The ICC paradigm (1) employs tools to efficiently use full-field data to calibrate high-fidelity material models, (2) aligns the data needed with the data collected by adopting an optimal experimental design protocol, (3) provides uncertainty metrics on the calibrated model parameters, and (4) incorporates these advances into a quasi real-time feedback loop. The ICC framework was validated synthetically with both low-fidelity and high-fidelity simulations paired with several different elastoplastic material models, and was also demonstrated experimentally with an aluminum 6061 cruciform exemplar specimen. Results showed that the ICC framework—in which Bayesian optimal experimental design actively guided the experiment— resulted in calibrations with similar or better accuracy than predetermined experiments based on subject matter expertise. Moreover, the ICC framework produced a complete model calibration— with quantified uncertainties on model parameters—in 1 week, a 5 - 10× increase in efficiency over traditional approaches. Thus, the ICC paradigm improves both the calibration process and quality, by (1) improving efficiency, which increases agility of solid mechanics modeling and enables utilization of computational simulation (CompSim) at earlier stages of the design cycle and (2) providing quantified, and in some cases reduced, parameter uncertainties, which increases confidence in model predictions and supports credible decision making.

97 MATHEMATICS AND COMPUTING↗

Evaluation of compressible-flow Preston tube calibrations

An experimental and analytical study has been made of the accuracy of various Preston tube calibration equations to determine local skin friction in two-dimensional supersonic and low-hypersonic flows. Experimental Preston tube calibration data from the present and previous studies were used to evaluate the calibration equations. The maximum value of the calibration parameters of the present data is more than an order of magnitude larger than that previously obtained; thereby, the evaluation of the various calibration equations is facilitated. The Preston tube technique was found to be very inaccurate in the low range of the calibration parameters. Above this range, there was a steady increase in accuracy with increasing values of the calibration parameters. No critical maximum tube diameter was found even with tubes about twice as large as the theoretical maximum allowable diameter. Of the two forms of the calibration equation previously existing, the logarithmic laws gave more accurate results than the power laws over an extended range of the calibration parameters in supersonic adiabatic flow.

Allen, J. M.↗