Data processing and calibration for tunable diode laser harmonic absorption spectrometers

Data processing and calibration methods are described for tunable diode laser absorption spectrometers which produce harmonic absorption spectra as raw data for measuring gas mixing ratios down to parts-per-trillion levels at a variety of pressures. The methods, which take advantage of modern computer speed, memory, and data storage capabilities, are applicable to the detection of weakly absorbing gases in quantitative industrial monitoring, in addition to aircraft and balloon atmospheric measurements for which they were designed. Algorithms for calibration and data analysis, including rejection of erroneous spectra, variation of effective integration time, spectral alignment prior to averaging, and plotting and archiving of results, have been tested on actual stratospheric laser spectra recorded by the Aircraft Laser Infrared Absorption Spectrometer (ALIAS) spectrometer in numerous flights of NASA's ER-2 aircraft.

May, Randy D.↗

Consistent Pixel Resolution Characterization of Deep Convective Clouds for Calibration

The NASA CERES project provides global TOA shortwave and longwave fluxes for climate monitoring and validation that spans over 20 years. CERES utilizes broadband fluxes derived from geostationary (GEO) imagers to estimate broadband fluxes between the CERES observations. In order for these fluxes to be viable, the GEO imager calibration must be stable over time. One such calibration method used by CERES is to evaluate ensemble sets of deep convective clouds (DCC) as invariant targets (IT) over time. DCC targets can also provide radiometric scaling between sensors. An international collaboration through GSICS is also evaluating the DCC-IT calibration methodology to provide consistent calibration coefficients across geostationary sensors. Tropical DCC are the coldest, brightest, and most Lambertian TOA Earth targets identified using a window channel brightness temperature threshold. The DCC-IT technique involves a large ensemble of TOA pixel-level reflectances, which are binned into probability density functions (PDF). The PDF structure dependency on sensor pixel resolution, which can vary greatly among sensors, is not well known. This study will identify the impact of pixel resolution on the DCC PDFs by aggregating VIIRS and Landsat OLI/TIRS pixel resolutions into various coarser pixel resolutions and comparing the shape and statistics of the resulting PDFs. This study should assist in mitigating the pixel resolution dependency in the DCC-IT approach for providing scaling factors between sensors.

Conor Haney↗

Note: Improved calibration of atomic force microscope cantilevers using multiple reference cantilevers

Overall precision of the simplified calibration method in J. E. Sader et al., Rev. Sci. Instrum. 83, 103705 (2012), Sec. III D, is dominated by the spring constant of the reference cantilever. The question arises: How does one take measurements from multiple reference cantilevers, and combine these results, to improve uncertainty of the reference cantilever’s spring constant and hence the overall precision of the method? This question is addressed in this note. Its answer enables manufacturers to specify of a single set of data for the spring constant, resonant frequency, and quality factor, from measurements on multiple reference cantilevers. With this data set, users can trivially calibrate cantilevers of the same type.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MaLTESE: Large-Scale Simulation-Driven Machine Learning for Transient Driving Cycles

Optimal engine operation during a transient driving cycle is the key to achieving greater fuel economy, engine efficiency, and reduced emissions. In order to achieve continuously optimal engine operation, engine calibration methods use a combination of static correlations obtained from dynamometer tests for steady-state operating points and road and/or track performance data. As the parameter space of control variables, design variable constraints, and objective functions increases, the cost and duration for optimal calibration become prohibitively large. In order to reduce the number of dynamometer tests required for calibrating modern engines, a large-scale simulation-driven machine learning approach is presented in this work. A parallel, fast, robust, physics-based reduced-order engine simulator is used to obtain performance and emission characteristics of engines over a wide range of control parameters under various transient driving conditions (drive cycles). We scale the simulation up to 3,906 nodes of the Theta supercomputer at the Argonne Leadership Computing Facility to generate data required to train a machine learning model. The trained model is then used to predict various engine parameters of interest, and the results are compared with those predicted by the engine simulator. Our results show that a deepneural-network-based surrogate model achieves high accuracy: Pearson product-moment correlation values larger than 0.99 and mean absolute percentage error within 1.07% for various engine parameters such as exhaust temperature, exhaust pressure, nitric oxide, and engine torque. Once trained, the deep-neural-network-based surrogate model is fast for inference: it requires about 16 mu s for predicting the engine performance and emissions for a single design configuration compared with about 0.5 s per configuration with the engine simulator. Moreover, we demonstrate that transfer learning and retraining can be leveraged to incrementally retrain the surrogate model to cope with new configurations that fall outside the training data space.

deep learning↗

Radiometric Characterization of IKONOS Multispectral Imagery

A radiometric characterization of Space Imaging's IKONOS 4-m multispectral imagery has been performed by a NASA funded team from the John C. Stennis Space Center (SSC), the University of Arizona Remote Sensing Group (UARSG), and South Dakota State University (SDSU). Both intrinsic radiometry and the effects of Space Imaging processing on radiometry were investigated. Relative radiometry was examined with uniform Antarctic and Saharan sites. Absolute radiometric calibration was performed using reflectance-based vicarious calibration methods on several uniform sites imaged by IKONOS, coincident with ground-based surface and atmospheric measurements. Ground-based data and the IKONOS spectral response function served as input to radiative transfer codes to generate a Top-of-Atmosphere radiance estimate. Calibration coefficients derived from each vicarious calibration were combined to generate an IKONOS radiometric gain coefficient for each multispectral band assuming a linear response over the full dynamic range of the instrument. These calibration coefficients were made available to Space Imaging, which subsequently adopted them by updating its initial set of calibration coefficients. IKONOS imagery procured through the NASA Scientific Data Purchase program is processed with or without a Modulation Transfer Function Compensation kernel. The radiometric effects of this kernel on various scene types was also investigated. All imagery characterized was procured through the NASA Scientific Data Purchase program.

Pagnutti, Mary↗

A protocol for calculating basal melt rates in the ISMIP6 Antarctic ice sheet projections

Climate model projections have previously been used to compute ice shelf basal melt rates in ice sheet models, but the strategies employed – e.g., ocean input, parameterization, calibration technique, and corrections – have varied widely and are often ad hoc. Here, a methodology is proposed for the calculation of circum-Antarctic basal melt rates for floating ice, based on climate models, that is suitable for ISMIP6, the Ice Sheet Model Intercomparison Project for CMIP6 (6th Coupled Model Intercomparison Project). The past and future evolution of ocean temperature and salinity is derived from a climate model by estimating anomalies with respect to the modern day, which are added to a present-day climatology constructed from existing observational datasets. Temperature and salinity are extrapolated to any position potentially occupied by a simulated ice shelf. A simple formulation is proposed for a basal melt parameterization in ISMIP6, constrained by the observed temperature climatology, with a quadratic dependency on either the nonlocal or local thermal forcing. Two calibration methods are proposed: (1) based on the mean Antarctic melt rate (MeanAnt) and (2) based on melt rates near Pine Island's deep grounding line (PIGL). Future Antarctic mean melt rates are an order of magnitude greater in PIGL than in MeanAnt. The PIGL calibration and the local parameterization result in more realistic melt rates near grounding lines. PIGL is also more consistent with observations of interannual melt rate variability underneath Pine Island and Dotson ice shelves. This work stresses the need for more physics and less calibration in the parameterizations and for more observations of hydrographic properties and melt rates at interannual and decadal timescales.

54 ENVIRONMENTAL SCIENCES↗

NOAA-11 AVHRR visible and near-IR inflight calibration

An inflight calibration method for NOAA-11 AVHRR visible and near-infrared bands using desert reflectance is discussed. The results show a decrease in sensor systems response of 22 percent and 32 percent for the visible and near-infrared bands, respectively, relative to the published preflight calibration. The relative accuracy of the present calibration to the calibration of NOAA-9, published elsewhere, is + or - 3 percent. The absolute accuracy is around + or - 6 percent. An approximate correction to the Normalized Difference Vegetation Index ratio suggests that an increase of 0.06 is required.

Holben, B. N.↗

Application of the Monte Carlo method for spectrometer calibration to determine the surface activity of radionuclides deposited on the ground

The results of efficiency calibration and verification of the in situ method with application of a handheld spectrometer with high-purity germanium detector are presented. The conducted studies show that the calibration of spectrometer efficiency with the use of the Monte Carlo method can be applied for measurement of the surface activity of radionuclides deposited on the ground with an uncertainty of not more than 22%.

07 ISOTOPE AND RADIATION SOURCES↗

Estimation Matrix Calibration of PMU Data-driven State Estimation Using Neural Network

Linear state estimation (LSE) is a phasor measurement unit (PMU) data-based power system state estimation that incorporates a linear measurement model in rectangular coordinates. Due to the high computational efficiency and high observational time-resolution, LSE can act as a supplementary state estimation in a wide-area monitoring system (WAMS). The performance of LSE is relatively sensitive to noises in measurements. Therefore, the estimation accuracy relies heavily on the accuracy of the estimation matrix, which is directly influenced by the measurement weight matrix. This paper proposes two novel calibration method of the estimation matrix using neural networks. One is based on the minimum absolute network loss (ANL), and the other is based on the minimum average squared network loss (ASNL). Both methods are tested and compared with LSE algorithms on the IEEE 14-bus system

neural network↗

The WRF-Solar Ensemble Prediction System to Provide Solar Irradiance Probabilistic Forecasts

In this study, we introduce the recently developed WRF-solar ensemble prediction system and a calibration method. The performances of forecast models are evaluated using the National Solar Radiation Database observational analysis for day-ahead solar irradiance predictions. The results demonstrate that the ensemble forecast improves the quality of the forecasts by considering the uncertainty of each ensemble member. The analog ensemble calibration contributed to the reduction of positive bias and an overall improvement in the probabilistic attributes, such as reliability and statistical consistency.

14 SOLAR ENERGY↗

SNPP VIIRS Day Night Band: Ten Years of On-Orbit Calibration and Performance

Aboard the polar-orbiting SNPP satellite, the VIIRS instrument has been in operation since launch in October 2011. It is a visible and infrared radiometer with a unique panchromatic channel capability designated as a day-night band (DNB). This channel covers wavelengths from 0.5 to 0.9 µm and is designed with a near-constant spatial resolution for Earth observations 24 h a day. The DNB operates at 3 gain stages (low, middle, and high) to cover a large dynamic range. An onboard solar diffuser (SD) is used for calibration in the low gain stage, and to enable the derivation of gain ratios between the different stages. In this paper, we present the SNPP VIIRS DNB calibration performed by the NASA VIIRS characterization support team (VCST). The DNB calibration algorithms are described to generate the calibration coefficient look up tables (LUTs) for the latest NASA Level 1B Collection 2 products. We provide an evaluation of DNB on-orbit calibration performance. This activity supports the NASA Earth science community by delivering consistent VIIRS sensor data products via the Land Science Investigator-led Processing Systems, including the SD degradation applied for DNB calibrations in detector gain and gain ratio trending. The DNB stray light contamination and its correction are highlighted. Performance validations are presented using comparisons to the calibration methods employed by NOAA’s operational Interface Data Processing Segment. Further work on stray light corrections is also discussed.

VIIRS↗

Advances in turbine blade temperature measurements

Radiation pyrometry principles and imaging methods like photography and photoelectric scanning are combined to make accurate research quality temperature measurements on turbine airfoils. Two systems are described for obtaining detailed temperature distribution measurements: an infrared photographic system for stationary vanes and a photoelectric scanning system for rotating blades. An overview is presented outlining the design, calibration methods, and recent test results.

Pollack, F. G.↗

Advances in turbine blade temperature measurements

Radiation pyrometry principles and imaging methods like photography and photoelectric scanning are combined to make accurate research quality temperature measurements on turbine airfoils. Two systems are described for obtaining detailed temperature distribution measurements: an infrared photographic system for stationary vanes and a photoelectric scanning system for rotating blades. An overview is presented outlining the design, calibration methods, and recent test results

Pollack, F. G.↗

SU-F-J-75: Accuracy and Stability of Electron Density Measurements Across Patient Size Using Dual Energy CT

Purpose: Dual energy (DE) CT can be used to characterize tissue composition. One application of DE CT is to measure electron density (ED, rho) and atomic number (Z) for use in radiation therapy treatment planning. This work evaluated the accuracy and stability of ED estimation as patient size varied for both single-energy (SE) and DE CT. Methods: An ED phantom (CIRS) and four torso-shaped water tanks (lateral widths 15, 25, 35 and 45 cm) containing 8 tissue-simulating cylinders of known ED were scanned on a dual-source CT system (Siemens Somatom Force) in SE (120 kV) and DE (90/150Sn) modes. Additional scans were performed on the 15 and 25 cm water tanks using DE techniques of 70/150Sn and 80/150Sn, respectively. CTDIvol was matched for all SE and DE scans for a given phantom size. Images were reconstructed using quantitative kernels to preserve CT number accuracy. ED was estimated in each test cylinder and in solid and liquid water using calibration measurements acquired in the CIRS phantom (SE) and a Rho-Z algorithm (DE). Results: ED estimates showed good agreement with the nominal ED values when using Rho-Z (slope = 1.0051, R2 = 0.9982). Mean percent error was similar between SE (1.21%) and DE (1.28%). Mean deviation across patient size decreased 34% (1.43% with SE, 0.95% with DE). When compared to 90/150Sn, DE techniques of 70/150Sn and 80/150Sn showed mean differences in ED of 0.43% and 0.15%, respectively. Conclusion: While both DE Rho-Z and SE CT number calibration methods are both accurate for estimating ED, Rho-Z offers the advantages of having less variability across patient size, not requiring a phantom calibration, and being able to distinguish between materials of similar attenuation, but different chemical composition. Low kV DE pairs are an option in small patients due to lack of effect on ED accuracy. This research was supported by Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

The WRF-Solar Ensemble Prediction System to Provide Solar Irradiance Probabilistic Forecasts

In this study, we introduce the recently developed WRF-Solar Ensemble System (WRF-Solar EPS) and a calibration method. The performances of forecast models are evaluated using the National Solar Radiation Data Base (NSRDB) observational analysis for day-ahead solar irradiance predictions. The results demonstrate that the ensemble forecast improves the quality of the forecasts by taking into account the uncertainty of each ensemble member. The Analog Ensemble (AnEn) calibration contributed to the reduction of positive bias and an overall improvement in the probabilistic attributes such as reliability and statistical consistency.

analog ensemble↗

MO-A-BRC-02: TG167 Report - Detailed Description

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. NRC, FDA, Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, European Commission for CE Marking, and institutional review boards and radiation safety committees. Learning Objectives: Understand the necessary dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use. Evaluate risks and benefits from regulatory and safety perspectives. Identify necessary resources and create a plan for clinical introduction of innovative brachytherapy device or applications. Consultant for Theragenics Corp.; R. Nath, Consultant to Theragenics Corp.

60 APPLIED LIFE SCIENCES↗

MO-A-BRC-00: TG167: Clinical Recommendations for Innovative Brachytherapy Devices and Applicators

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. NRC, FDA, Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, European Commission for CE Marking, and institutional review boards and radiation safety committees. Learning Objectives: Understand the necessary dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use. Evaluate risks and benefits from regulatory and safety perspectives. Identify necessary resources and create a plan for clinical introduction of innovative brachytherapy device or applications. Consultant for Theragenics Corp.; R. Nath, Consultant to Theragenics Corp.

60 APPLIED LIFE SCIENCES↗

MO-A-BRC-01: TG167 Report - Introduction

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used to evaluate innovative radiotherapy devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining equivalence of the innovative device to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of an innovative brachytherapy device or application is a critical part in which physicists are actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative products or applications and includes evaluation of 1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, 2) risks and benefits from regulatory and safety perspectives, and 3) resource assessment and preparedness. Further, calibration methods should be traceable to a primary standards dosimetry laboratory such as NIST in the U.S. or to other primary standards dosimetry laboratory located elsewhere. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the ADCLs is encouraged before a source is introduced into widespread routine clinical use. The AAPM and GEC-ESTRO have developed guidelines for the safe and consistent application of brachytherapy using innovative brachytherapy devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. NRC, FDA, Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, European Commission for CE Marking, and institutional review boards and radiation safety committees. Learning Objectives: Understand the necessary dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use. Evaluate risks and benefits from regulatory and safety perspectives. Identify necessary resources and create a plan for clinical introduction of innovative brachytherapy device or applications. Consultant for Theragenics Corp.; R. Nath, Consultant to Theragenics Corp.

60 APPLIED LIFE SCIENCES↗