Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Performance testing of a high frequency link converter for Space Station power distribution system

The testing of a brassboard version of a 20-kHz high-frequency ac voltage link prototype converter dynamics for Space Station application is presented. The converter is based on a three-phase six-pulse bridge concept. The testing includes details of the operation of the converter when it is driving an induction machine source/load. By adapting a field orientation controller (FOC) to the converter, four-quadrant operation of the induction machine from the converter has been achieved. Circuit modifications carried out to improve the performance of the converter are described. The performance of two 400-Hz induction machines powered by the converter with simple V/f regulation mode is reported. The testing and performance results for the converter utilizing the FOC, which provides the capability for rapid torque changes, speed reversal, and four-quadrant operation, are reported.

Sul, S. K.↗

High-voltage 6H-SiC p-n junction diodes

A chemical vapor deposition (CVD) process has been used to produce device structures of n- and p-type 6H-SiC epitaxial layers on commercially produced single-crystal 6H-SiC wafers. Mesa-style p-n junction diodes were successfully fabricated from these device structures using reactive ion etching, oxide passivation, and electrical contact metallization techniques. When tested in air, the 6H-SiC diodes displayed excellent rectification characteristics up to the highest temperature tested, 600 C. To observe avalanche breakdown of the p-n junction diodes, testing under a high-electrical-strength liquid was necessary. The avalanche breakdown voltage was 1000 V representing the highest reverse breakdown voltage to be reported for any CVD-grown SiC diode.

Matus, L. G.↗

Evaluation of Series T22 Wet Tantalum Capacitors

Several types of advanced wet tantalum capacitors, and series T22 in particular, are designed without internal Teflon sealing that is used for military grade, CLR style capacitors. This raises concerns regarding hermeticity of the single seal parts and their capability to withstand high internal gas pressures that might develop during operation in space. To address these issues, T22 series capacitors rated to 50 V and 125 V were subjected to highly accelerated life testing (HALT) at 125 C and rated voltage and step stress random vibration testing (RVT). To simulate conditions of storage or operation under increased internal gas pressure, the parts were stored at temperature of 150 C for 2500 hr (HTS150). Electrical characteristics of the parts were measured through the storage testing and the hermeticity leak rate was tested before and after HTS150. To assess thermo-mechanical robustness of the part, capacitors were manually soldered onto printed wired boards (PWB) and stressed by 1000 temperature cycles between -55 C and +125 C. The effect of temperature cycling was assessed by additional HALT at different temperatures. Results show that T22 series capacitors have robust design and can satisfy requirements for space applications.

Wet tantalum capacitors↗

Shock Generation and Control Using DBD Plasma Actuators

This report is the final report of a NASA Phase I SBIR contract, with some revisions to remove company proprietary data. The Shock Boundary Layer Interaction (SBLI) phenomena in a supersonic inlet involve mutual interaction of oblique shocks with boundary layers, forcing the boundary layer to separate from the inlet wall. To improve the inlet efficiency, it is desired to prevent or delay shock-induced boundary layer separation. In this effort, Innovative Technology Applications Company (ITAC), LLC and the University of Notre Dame (UND) jointly investigated the use of dielectric-barrier-discharge (DBD) plasma actuators for control of SBLI in a supersonic inlet. The research investigated the potential for DBD plasma actuators to suppress flow separation caused by a shock in a turbulent boundary layer. The research involved both numerical and experimental investigations of plasma flow control for a few different SBLI configurations: (a) a 12 wedge flow test case at Mach 1.5 (numerical and experimental), (b) an impinging shock test case at Mach 1.5 using an airfoil as a shock generator (numerical and experimental), and (c) a Mach 2.0 nozzle flow case in a simulated 15 X 15 cm wind tunnel with a shock generator (numerical). Numerical studies were performed for all three test cases to examine the feasibility of plasma flow control concepts. These results were used to guide the wind tunnel experiments conducted on the Mach 1.5 12 degree wedge flow (case a) and the Mach 1.5 impinging shock test case (case b) which were at similar flow conditions as the corresponding numerical studies to obtain experimental evidence of plasma control effects for SBLI control. The experiments also generated data that were used in validating the numerical studies for the baseline cases (without plasma actuators). The experiments were conducted in a Mach 1.5 test section in the University of Notre Dame Hessert Laboratory. The simulation results from cases a and b indicated that multiple spanwise actuators in series and at a voltage of 75 kVp-p could fully suppress the flow separation downstream of the shock. The simulation results from case c showed that the streamwise plasma actuators are highly effective in creating pairs of counter-rotating vortices, much like the mechanical vortex generators, and could also potentially have beneficial effects for SBLI control. However, to achieve these effects, the positioning and the quantity of the DBD actuators used must be optimized. The wind tunnel experiments mapped the baseline flow with good agreement to the numerical simulations. The experimental results were conducted with spanwise actuators for cases a and b, but were limited by the inability to generate a sufficiently high voltage due to arcing in the wind-tunnel test-section. The static pressure in the tunnel was lower than the static pressure in an inlet at flight conditions, promoting arching and degrading the actuator performance.

Patel, Mehul P.↗

Tevatron Electron Lens Upgrade

A novel high voltage modulator had been under development for 1.5 years. It was completed tested on the bench and became a part of the TEL2 system in October 2008. The modulator is used to drive the electron gun anode. We provide technical details on the stacked transformer modulator, analyze its performance and discuss the design challenges. The results of the beam studies made possible by the new high voltage modulator are reported.

Saewert, G. W.↗

Ground testing of array modules for the photovoltaic array space power (PASP) experiment

One of the objectives of the PASP experiment is the verification of cost-effective ground simulations of high-voltage solar array/space-environment interactions by comparing the results with flight data. These ground tests consist of electrical characterization, thermal cycling, and plasma chamber simulations. The results of the latter tests are reported. Five array modules which are representative of the flight arrays were tested. The module types are planar silicon, planar gallium arsenide, planar silicon passivated with an integrally deposited cover glass, mini-Cassegrainian concentrator, and SLATS concentrator. The modules were biased to -1000 V in varying plasma densities from 4 x 103 to 2 x 105 e-/cu cm. Each array was tested in both dark and illuminated conditions with a load resistance. In addition to monitoring arcing during the plasma tests, the arrays were visually inspected and electrically characterized before and after exposure in the chamber. The electrical results are tabulated and briefly discussed.

Morris, Robert K.↗

A SEP Mission to Jupiter Using the Stretched Lens Array

As space exploration continues to be a primary focus of NASA, solar electric propulsion (SEP) becomes a forerunner in the mode of transportation to reach other planets in our solar system. Several critical issues emerge as potential barriers to this approach such as reducing solar array radiation damage, operating the array at high voltage (>300 V) for extended times for Hall or ion thrusters, and designing an array that will be resistant to micrometeoroid impacts and the differing environmental conditions as the vehicle travels further into space. It is also of great importance to produce an array that is light weight to preserve payload mass fraction and to do this at a cost that is lower than today's arrays. This paper will describe progress on an array that meets all these requirements and will detail its use in a solar electric mission to Jupiter. From 1998-2001, NASA flew the Deep Space 1 mission that validated the use of ion propulsion for extended space missions. This highly successful two-year mission also used a novel SCARLET solar array that concentrated sunlight eight-fold onto small area solar cells. This array performed flawlessly and within 2% of its projected performance over the entire mission. That design has evolved into the Stretched Lens Array (SLA) shown in figure 1. The primary difference between SCARLET and the SLA is that no additional glass cover is used over the silicone lens. This has led to significant mass, cost and complexity reductions. The module shown in figure 1 is the latest version of the design. This design leads to a specific power exceeding 300 W/kg at voltages exceeding 300 V. In addition, this module has been tested to voltages over 1000 V while under hypervelocity particle impact in a plasma environment with no arcing. Furthermore array segments are under test for corona breakdown that can become a critical issue for long term, high voltage missions.

Brandhorst, Henry W.↗

Assessment of lumen degradation and remaining useful life of LEDs using particle filter

With the development of light-emitting diode (LED) technology, light emitting diodes system is becoming a popular light source in daily life and industry area. It has shown that Led from same factory and work under same working condition, may have significantly different behavior. Therefore, it is very important to learn the fail mechanisms, especially in the case of safety critical and harsh environment application. This paper focus on a prognostic health management (PHM) method based on the measurement of forward voltage and forward current of bare LED under harsh environment. In this paper, experiment has been done with ten samples. Ten pristine bare LEDs have been tested at 85°C while simultaneously being subjected to 85% humid environment. Pulse width modulation (PWM) control method has been employed to drive the bare LED in order to reduce the heat effect caused by forward current and high frequency (300HZ) data acquisition has been used to measure the peak forward voltage and forward current. Test to failure (lumen drops to 70 percent) data has been measured to study the effects of high temperature and humid environment loadings on the bare LED. Also, solid state cooling method with peltier cooler has been used to control the temperature of LED in the integrating sphere when take the measurement of lumen flux. The shift of forward voltage forward current curve and lumen degradation has been recorded to help build the fail model and predicted the remaining useful life. In this method, particle filter has been employed to predict the remaining useful life (RUL) of the bare LED and give us a whole picture how Led system fails. Result shows that predication of remaining useful life of Led, made by the particle filter model works under reasonable limit, and hence this method can be employed to predict the failure of Led caused by thermal and humid stress under harsh environment.

42 ENGINEERING↗

Distributed Energy Communications & Controls, Lab Activities - Synopsis

Electric power distribution systems are experiencing outages due to a phenomenon known as fault induced delayed voltage recovery (FIDVR) due to air conditioning (A/C) compressor motor stall. Local voltage collapse from FIDVR is occurring in part because modern air-conditioner and heat pump compressor motors are much more susceptible to stalling during a voltage sag or dip than older motors. These motors can stall in less than three cycles (0.05 s) when a fault, for example, on the sub-transmission system, causes voltage on the distribution system to sag to 70% or less of nominal. We completed a new test system for A/C compressor motor stall testing at the DECC Lab. The A/C Stall test system is being used to characterize when and how compressor motors stall under low voltage and high compressor pressure conditions. However, instead of using air conditioners, we are using high efficiency heat pumps. We have gathered A/C stall characterization data for both sustained and momentary voltage sags of the test heat pump. At low enough voltage, the heat pump stalls (compressor motor stops and draws 5-6 times normal current in trying to restart) due to low inertia and low torque of the motor. For the momentary sag, we are using a fast acting contactor/switch to quickly switch from nominal to the sagged voltage in cycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling high areal capacity for Co-free high voltage spinel materials in next-generation Li-ion batteries

The rapidly growing technological demand for lithium-ion batteries has prompted the development of novel cathode materials with high energy density, low cost, and improved safety. High voltage spinel, LiNi 0.5 Mn 1.5 O 4 (LNMO), is one of the most promising candidates yet to be commercialized. The two primary obstacles for this material are the inferior electronic conductivity and fast capacity degradation in full cells due to the high operating voltage. By systematically addressing these limitations, we successfully develop a thick LNMO electrode with areal capacity loadings up to 3 mAh·cm –2 . The optimized thick electrode is paired with a commercial graphite anode at both the coin cell and pouch cell level, achieving a full cell capacity retention as high as 72% and 78%, respectively, after 300 cycles. We attribute this superior cycling stability to careful optimizations of cell components and testing conditions, with a specific focus improving electronic conductivity and high voltage compatibility. These results suggest precise control of materials quality, electrode architecture and electrolyte optimization can soon support the development of a cobalt-free battery system based on a thick LNMO cathode (>4 mAh·cm 2 ), which will eventually meet the needs of next-generation Li-ion batteries with reduced cost, improved safety, and assured sustainability.

25 ENERGY STORAGE↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

Discharge of 1400 AH lithium thionyl chloride cells into voltage reversal

The development of a high energy density battery is discussed. Tests were conducted on a 1400 AH cell and they include: drop tests, crush tests, vibration and shock tests, hydrostatic pressure effects, charge current tests, and discharge tests. None of these tests led to a venting or explosion of the cell. Criteria are presented for extending RV safety of a 1400 AH cell.

Zolla, A. E.↗

Predictive Coordinated and Cooperative Voltage Control for Systems With High Penetration of PV

In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.

14 SOLAR ENERGY↗

Leo space plasma interactions

Photovoltaic arrays interact with the low earth orbit (LEO) space plasma in two fundamentally different ways. One way is the steady collection of current from the plasma onto exposed conductors and semiconductors. The relative currents collected by different parts of the array will then determine the floating potential of the spacecraft. In addition, these steady state collected currents may lead to sputtering or heating of the array by the ions or electrons collected, respectively. The second kind of interaction is the short time scale arc into the space plasma, which may deplete the array and/or spacecraft of stored charge, damage solar cells, and produce EMI. Such arcs only occur at high negative potentials relative to the space plasma potential, and depend on the steady state ion currents being collected. New high voltage solar arrays being incorporated into advanced spacecraft and space platforms may be endangered by these plasma interactions. Recent advances in laboratory testing and current collection modeling promise the capability of controlling, and perhaps even using, these space plasma interactions to enable design of reliable high voltage space power systems. Some of the new results may have an impact on solar cell spacing and/or coverslide design. Planned space flight experiments are necessary to confirm the models of high voltage solar array plasma interactions. Finally, computerized, integrated plasma interactions design tools are being constructed to place plasma interactions models into the hands of the spacecraft designer.

Ferguson, Dale C.↗

Breakdown voltage of metal-oxide resistors in liquid argon

We characterized a sample of metal-oxide resistors and measured their breakdown voltage in liquid argon by applying high voltage (HV) pulses over a 3 second period. This test mimics the situation in a HV-divider chain when a breakdown occurs and the voltage across resistors rapidly rise from the static value to much higher values. All resistors had higher breakdown voltages in liquid argon than their vendor ratings in air at room temperature. Failure modes range from full destruction to coating damage. In cases where breakdown was not catastrophic, subsequent breakdown voltages were lower in subsequent measuring runs. One resistor type withstands 131 kV pulses, the limit of the test setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photocathode Optimization for a Dynamic Transmission Electron Microscope: Final Report

The Dynamic Transmission Electron Microscope (DTEM) team at Harvey Mudd College has been sponsored by LLNL to design and build a test setup for optimizing the performance of the DTEM's electron source. Unlike a traditional TEM, the DTEM achieves much faster exposure times by using photoemission from a photocathode to produce electrons for imaging. The DTEM team's work is motivated by the need to improve the coherence and current density of the electron cloud produced by the electron gun in order to increase the image resolution and contrast achievable by DTEM. The photoemission test setup is nearly complete and the team will soon complete baseline tests of electron gun performance. The photoemission laser and high voltage power supply have been repaired; the optics path for relaying the laser to the photocathode has been finalized, assembled, and aligned; the internal setup of the vacuum chamber has been finalized and mostly implemented; and system control, synchronization, and data acquisition has been implemented in LabVIEW. Immediate future work includes determining a consistent alignment procedure to place the laser waist on the photocathode, and taking baseline performance measurements of the tantalum photocathode. Future research will examine the performance of the electron gun as a function of the photoemission laser profile, the photocathode material, and the geometry and voltages of the accelerating and focusing components in the electron gun. This report presents the team's progress and outlines the work that remains.

42 ENGINEERING↗

Investigation of problems associated with solid encapsulation of high voltage electronic assemblies; also Reynolds connector study

Electric breakdown prevention in vacuum and encapsulation of high voltage electronic circuits was studied. The lap shear method was used to measure adhesive strengths. The permeation constants of air at ambient room temperature through four different space-grade encapsulants was measured. Order of magnitude was calculated for the time that air bubble pressures drop to the corona region. High voltage connectors with L-type cable attached were tested in a vacuum system at various pressures. The cable system was shown to suppress catastrophic breakdown when filled with and surrounded by gas in the corona region of pressures, but did not prove to be completely noise free.

Bever, R. S.↗

Direct measurement of lower atmospheric vertical potential differences

A high impedance system has been developed to make direct measurements of the atmospheric potential difference up to several thousand feet. A tethered balloon flown from Wallops Island, Virginia was used to loft a high voltage, insulated wire and a conducting collector in a test flight to 550 meters for two days of experiments in October 1980. The balloon was equipped with a payload to measure exact altitude, wind speed and direction, and other meteorological parameters. Electric potentials of 170,000 volts at 550 meters were measured. The collected currents which could be drawn through the wire by grounding the lower end were in the 10 microamp range indicating a system impedance of about 10 to the 10th ohms. This paper describes the apparatus and details of these measurements.

Holzworth, R. H.↗