Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERCONNECTED POWER SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

NREL/SCE High Penetration PV Integration Project: FY13 Annual Report

In 2010, the National Renewable Energy Laboratory (NREL), Southern California Edison (SCE), Quanta Technology, Satcon Technology Corporation, Electrical Distribution Design (EDD), and Clean Power Research (CPR) teamed to analyze the impacts of high penetration levels of photovoltaic (PV) systems interconnected onto the SCE distribution system. This project was designed specifically to benefit from the experience that SCE and the project team would gain during the installation of 500 megawatts (MW) of utility-scale PV systems (with 1-5 MW typical ratings) starting in 2010 and completing in 2015 within SCE's service territory through a program approved by the California Public Utility Commission (CPUC). This report provides the findings of the research completed under the project to date.

14 SOLAR ENERGY↗

Average and Marginal Capacity Credit Values of Renewable Energy and Battery Storage in the United States Power System

As deployment of renewable resources and storage continue to significantly grow in the coming decades, these technologies will play increasingly important roles in maintaining power systems' resource adequacy. Few analyses so far offer comprehensive comparisons of forward-looking average and marginal capacity credits of variable renewable energy and storage in the U.S. interconnections across a wide range of possible futures. To fill this research gap, we quantify the average and marginal capacity credits of solar PV, onshore and offshore wind, and batteries between 2026 and 2050 across the U.S power systems to examine the temporal trends, spatial patterns, and trade-offs between these two capacity accreditation approaches. Across technologies, capacity credits of solar PV most clearly follow downward trends over time, reflecting the significant rise in solar PV generation share as the grid decarbonizes. While battery storages' generation shares also rise significantly over time, their capacity credits always remain stably high due to their capabilities to be dispatched strategically during critical periods to maintain reliability. On the other hand, capacity credits of wind technologies in general follow slight upward trends as their generation shares level off. There are strong spatial variabilities of both average and marginal capacity credits across technologies, but capacity credits of solar PV displaying the most obvious spatial patterns with high capacity credits concentrating in wind-rich, solar-poor regions in SPP, PJM, and MISO, suggesting potential reliability benefits of interconnection-wide planning for renewable energy deployments. Additionally, except for offshore wind, average capacity credits of all other renewable technologies tend to be higher than their marginal capacity credits, indicating that existing renewable resources tend to be accredited higher than new resources at almost any time.

25 ENERGY STORAGE↗

Capacity value assessments of wind power

This article describes some of the recent research into the capacity value of wind power. With the worldwide increase in wind power during the past several years, there is increasing interest and significance regarding its capacity value because this has a direct influence on the amount of other (nonwind) capacity that is needed. We build on previous reviews from IEEE and IEA W ind T ask 25 a and examine recent work that evaluates the impact of multiple‐year data sets and the impact of interconnected systems on resource adequacy. We also provide examples that explore the use of alternative reliability metrics for wind capacity value calculations. We show how multiple‐year data sets significantly increase the robustness of results compared to single‐year assessments. Assumptions regarding the transmission interconnections play a significant role. To date, results regarding which reliability metric to use for probabilistic capacity valuation show little sensitivity to the metric. WIREs Energy Environ 2017, 6:e226. doi: 10.1002/wene.226 This article is categorized under: Wind Power > Economics and Policy Wind Power > Systems and Infrastructure Energy Infrastructure > Economics and Policy

Milligan, Michael↗

Redefining What's Possible for Renewable Energy: Grid Integration

The Energy Department's National Renewable Energy Laboratory (NREL) is spearheading engineering innovations that will help optimize the entire energy system, and the lab's analysis capabilities complement that engineering work by identifying ways to integrate renewable energy effectively and economically. This 3-minute video shows how NREL research and analysis are redefining what’s possible for renewable energy on the grid.

14 SOLAR ENERGY↗

NREL + Verizon Wireless

Verizon Wireless and the National Renewable Energy Laboratory (NREL) are working to develop and validate a new design solution for telecommunications facilities. Network equipment is all DC, so rather than relying on conventional AC power, the design will employ photovoltaics (PV) and batteries, and it will require new DC cooling systems. The new design will ease utility interconnection by connecting PV to the DC bus and batteries, increase resiliency by allowing PV to contribute - and cooling to continue - in a power outage, lower costs with day-to-day utility cost savings, and increase efficiency through reduced part count and fewer power conversions from DC to AC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of climate change on water availability and its propagation through the Western U.S. power grid

Climate impact assessment for power systems has tended to focus on the effects of water availability on generation without explicitly considering how these impacts propagate through the interconnected grid to affect generation in other locations. We investigate the impact of projected water availability on the operations of the contemporary Western U.S. power grid, focusing specifically on regional interdependencies. Hydrologic simulations derived from three GCMs (CCSM4, INMCM4 and GFDL-CM3) and two radiative scenarios (RCP4.5 and RCP8.5) are used to force a large-scale, distributed water management model (MOSART-WM), which translates water availability into power generation constraints at hydropower plants and water-dependent thermo-electric plants. Power system dynamics are evaluated using the production cost model PLEXOS. We find that the inter-regional connections across the Western U.S. electricity infrastructure are key in managing drastic variations in regional water availability. Net generation in the Northwest and Northern California is substantially sensitive to local water availability. Generation from the Desert Southwest emerges as a critical resource to compensate for variations in water availability in those regions. Climate change impacts on Northwestern water availability therefore drive future changes in other regions’ generation and regional power flows. The large inter-annual hydrological variability of Northern California exacerbates grid stress arising from long-term changes in water availability in the Northwest. While the regional power flow directions seem insensitive to long-term variations in water availability, the analysis highlights the need to consider other compounding regional factors such as changes in Southern California net load or changes in regional fuel prices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Small-Signal Stability Analysis of Large-Scale Power Systems in Response to Variability of Offshore Wind Power Plants

This paper presents a methodology for a small-signal stability analysis of large-scale power systems in response to variability of offshore wind power plants. This study considers the variability of wind power as the source of disturbance introduced to the system. To accomplish this goal, a singular value decomposition-total least squares extended Prony analysis is used to assess the small-signal voltage stability. In addition, a swing-based frequency response metric is used to assess the small-signal frequency stability. The case study here considers the integration of a 1000-MW offshore wind power plant, operating in Lake Erie, into the FirstEnergy/PJM service territory. This study uses a realistic model of the 63 000-bus test system that represents the U.S. Eastern Interconnection. The results verify the utility and practicality of this methodology for the integration studies of offshore wind power plants.

17 WIND ENERGY↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the PJM Interconnection. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure to a multitude of cybersecurity threats. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a hydropower-integrated BESS topology, specifically analyzing the slow regulation signal (Reg A) coming from the PJM market. Our simulation results demonstrate that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's transient instability during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Model-less Source Location for Forced Oscillation based on Synchrophasor and Moving Fast Fourier Transformation

Forced oscillations in power systems occur when the grid is driven by an external and periodic force. To quickly detect and locate the source of the forced oscillation is critical in terms of ensuring the reliability of an interconnected power grid. This paper explores the electromechanical wave propagation theory and the Fast Fourier Transformation to analyze the forced oscillations. It proposes a model-less, adaptive, fast, and accurate source location algorithm. The proposed algorithm is extensively evaluated through simulation data from a 70k-bus U.S. Eastern Interconnection test system and field-collected synchrophasor data from the distribution-level wide-area monitoring system, FNET/GridEye. The evaluation results demonstrate the correctness and effectiveness of the proposed model-less forced oscillation source location algorithm.

Wang, Weikang↗

Vehicle-to-manufacturing (V2M) system: A novel approach to improve energy demand flexibility for demand response towards sustainable manufacturing

The U.S. manufacturing sector accounts for 77% of the industrial energy consumption, but its participation in demand response (DR) programs is largely lagged behind. The limited flexibility in production scheduling under high capacity utilization and the lack of DR schemes that incorporate energy demand flexibility measures are deemed as major barriers. In this study, a framework of the interactive vehicles-to-manufacturing (V2M) energy sharing system is proposed to improve the energy demand flexibility of the aggregated system and enhance the DR effectiveness for manufacturers. The V2M-based DR scheme aims to reduce the energy cost by load shifting through joint production and energy sharing control, which can eventually promote manufacturing DR implementation even under high capacity utilization requirements and dynamic real-time electricity prices. The V2M system is modeled based on a discrete-Markov chain considering the complex interconnections among various manufacturing resources and multi-directional energy flows among manufacturing facilities, electric vehicles, and the power grid. Based on the system model, a mixed-integer nonlinear programming (MINLP) problem is formulated to identify the optimal DR scheme. The effectiveness of the proposed approach is validated through comparisons with traditional manufacturing DR schemes. Finally, the results show that a 2.1 to 6.5 times energy demand flexibility improvement and an additional 4.7% to 6.9% energy cost reduction can be achieved by the proposed approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Interconnection and Renewables Deployment Related Air Quality and Human Health Benefits in Southeast Asia

The Association of Southeast Asian Nations (ASEAN) has increasingly focused on multilateral electricity trade, improved grid resiliency and modernization. These opportunities in the power sector have been studied through the ASEAN Interconnection Masterplan Studies, the most recent of which is the ASEAN Interconnection Masterplan Study III (AIMS III). AIMS III assessed four different scenarios of power system in the ASEAN countries that include a base scenario and three additional scenarios (called optimum RE, ASEAN RE, and High RE) considering different levels of deployment of renewable energy (RE) and cross-border generation and trade of electricity for three years (2025, 2030, 2040). In this work, we quantify the potential air quality and public health co-benefits of AIMS III scenarios. For a rapidly expanding, energy hungry region like SE Asia generation is power generation is expected to increase significantly. The AIMS III scenarios' capacity expansion modeling suggest that: 1) Generation nearly doubles from 2025 to 2040 in all four AIMS III scenarios; 2) Most of the increased generation is met by coal in all four AIMS III scenarios; 3) While renewables generation increases in all four AIMS III scenarios, the fraction of total generation (its share) generally decreases because of the much greater increase in non-renewable sources, mostly coal. Only in the High RE Target scenario do renewables represent a higher share in 2040 than in 2025, though even here it is at the expense of natural gas rather than coal; 4) As a result, emissions of gaseous and aerosol pollutants increase significantly in all scenarios. Because emissions increase in 2040 compared to 2025 for all four AIMS III scenarios, so do PM2.5 concentrations. Even for the High RE Target scenario (the scenario with highest share of renewable energy), compared to the Base scenario in 2025, in 2040 PM2.5 concentrations are higher. Compared to the Base scenario in the same years, the Optimum RE and ASEAN RE Target scenarios do not differ very much from the Base in terms of PM2.5 concentration. The High RE Target scenario, on the other hand, yields noticeably lower PM2.5 concentration. For example, in 2040 the population-weighted decrease in annual average PM2.5 concentration in the High RE Target scenario relative to the Base scenario is 0.5 ug m-3. Compared to the Base scenario in 2040, each of the alternative AIMS III scenarios is estimated to result in net reductions in power-sector air quality-related excess mortality in the ASEAN region. Yet there are a few countries for which the Optimum RE and ASEAN RE Target result in increases in PM2.5-related excess mortality (Thailand and Vietnam for the ASEAN RE Target scenario and Thailand for the Optimum RE scenario). However, for the High RE Target scenario, all countries benefit and find reductions in excess mortality resulting from the power sector scenarios modeled in AIMS III with regionwide mortality decreasing by 16,000 compared to the Base scenario in 2040. In summary, our analysis finds that changing power generation emissions is a crucial lever for improving public health in ASEAN member countries and provides a pathway for policymakers to make decision backed by a realistic power sector expansion and air quality analyses.

air quality↗

Protecting Intelligent Distributed Power Grids against Cyber Attacks

Like other industrial sectors, the electrical power industry is facing challenges involved with the increasing demand for interconnected operations and control. The electrical industry has largely been restructured due to deregulation of the electrical market and the trend of the Smart Grid. This moves new automation systems from being proprietary and closed to the current state of Information Technology (IT) being highly interconnected and open. However, while gaining all of the scale and performance benefits of IT, existing IT security challenges are acquired as well. The power grid automation network has inherent security risks due to the fact that the systems and applications for the power grid were not originally designed for the general IT environment. In this paper, we propose a conceptual layered framework for protecting power grid automation systems against cyber attacks. The following factors are taken into account: (1) integration with existing, legacy systems in a non-intrusive fashion; (2) desirable performance in terms of modularity, scalability, extendibility, and manageability; (3) alignment to the 'Roadmap to Secure Control Systems in the Energy Sector' and the future smart grid. The on-site system test of the developed prototype security system is briefly presented as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interconnection of Distributed Energy Resources in the Indian Context: IEEE 1547-2018 Adaptation for Locally-Appropriate Grid Code Development

The rapid growth of distributed energy resources (DERs) in India and ambitious renewable energy goals set forth by the Indian government have created the need for appropriate distribution interconnection standards to ensure continued system stability, reliability, and resilience. Existing DER interconnection codes in India, at the time of publishing this report, lack many of the critical grid support functionalities for DERs which may protect bulk system stability, such as event ride-through provisions, frequency droop control, or appropriate trip thresholds given the increasing importance of distributed generation. The formal adoption of IEEE 1547-2018 by the Bureau of Indian Standards (BIS) marks a significant step towards achieving appropriate interconnection of DERs, though the implementation of such a standard must be accompanied with careful consideration of the current codes, regulations, and operation of the Indian power system. Studies on the performance of the functionalities within 1547-2018, which properly incorporate local operating conditions, can inform decisions related to the adoption and adaptation of the clauses present in the standard. This report outlines several of these key considerations for stakeholders and provides analyses illustrating the performance of grid support functionalities on typical Indian distribution feeders.

1547↗

A Review of Distributed Wind Interconnection Technology and Standards

The objectives of this report are to discuss the uniqueness of power converters in distributed wind (DW), identify challenges in complying with existing standards, prioritize technological innovations to facilitate interconnection of DW energy systems, and, where necessary, propose potential clarifications or revisions to standards. This report evaluates IEEE 1547-2018, IEEE 1547.1-2020, and UL 1741 SB standards and their implications for DW. A standards review and interviews of DW industry stakeholders were conducted to identify challenges in the application of current standards to DW. The study concludes with a combination of recommendations of pathways towards facilitating DW product commercialization and DW interconnection, which draws on participation from multiple stakeholders in the space. These solutions can continue to be explored to improve DW standards compliance, improve the applicability of the standards to DW, reduce certification testing barriers, and ensure the safe and reliable operation of DW energy resources and electric power systems.

17 WIND ENERGY↗

Microgrid Building Block Architecture, and Subcomponents Modeling and Demonstration in Controller Hardware-in-the-Loop

The recently proposed Microgrid Building Blocks (MBB) are ready-to-use components to build microgrids quickly, cheaply, and modularly. This work presents and demonstrates in controller hardware-in-the-loop (CHIL) three key subcomponents of an MBB architecture: power converter topology, control scheme, and communication framework. The addressed architecture aims for systems interconnection such as microgrid to grid and microgrid to microgrid. This paper studies each subcomponent in detail and validates the efficacy of the architecture through CHIL results.

Adib, Aswad [ORNL] (ORCID:000000020997056X)↗

Data sampling system for monitor and control station

System design is based on development of standardized, interchangeable modules that minimize power dissipation, interconnecting cables and size. Maximum flexibility is achieved by using building block approach where all data modules are identical and are connected at any remote location and addressed in random fashion from central unit.

Source record↗

Coupling of horizontal, vertical, and temporal resolving power of a satellite temperature sounder

This paper examines the interconnection between the vertical, horizontal, and temporal resolving power of satellite temperature-sounding system. Using a temperature cross section produced by interpolating a set of RAOBs taken at three locations in Texas; Shreveport, Louisiana; Jackson, Mississippi; and Montgomery, Alabama, and an artificially constructed temperature cross section, it was found that the horizontal and temporal resolving power are subject to strong controls imposed by the vertical resolving power of the sounder. Thus, to improve the horizontal or temporal resolving power it is necessary to improve the vertical resolving power' of the satellite instrument itself, or to extend the a priori external information to include correct horizontal and temporal structure.

Thompson, Owen E.↗

Eastern Interconnection Demand Response Potential

Demand response (DR), one of the key components in the Smart Grid initiative, has received increasing interest in recent years among power utilities, independent system operators, and policy makers. With this surge of interest in DR, in April 2010 the Department of Energy (DOE) issued a research call to provide technical support to the interconnection-level electric infrastructure planning projects they had issued earlier in the year. In Area of Interest 2, they identified a need/purpose: “The Eastern Interconnection States’ Planning Council (EISPC) seeks to significantly improve the knowledge base and modeling capabilities of demand-side resources for purposes of transmission planning.” In response to the research call, Oak Ridge National Laboratory (ORNL) conducted a research project to estimate the DR potential peak load reductions in the Eastern Interconnection area over the next two decades until 2030, as well as analyzed costs and benefits occurring out of the DR resources. This final report is the outcome of the study by a team of ORNL researchers with diverse backgrounds in engineering, economics, and public policy.

demand response↗