At least 361 records · Page 20

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

advanced metering infrastructure (AMI)↗

A Physical Model Enhanced Data Driven Method for High-Resolution Residential Load Profile Generation

Residential buildings account for significant energy consumption, creating opportunities to offer grid services. As electric utilities seek to implement effective system operation strategies, understanding residential energy consumption patterns becomes essential; However, the time intervals of load profiles measured by utilities' smart meters are typically from 15 minutes to 60 minutes. The low-resolution data make it hard to extract appliance-level load information, which is critical for providing grid services. This paper presents a load profile generator designed to produce synthetic load profiles for residential buildings that emphasizes the importance of accurate representations of realistic energy consumption patterns. The generator takes realistic low-resolution residential load measurements and weather data as inputs, producing 1-minute interval profiles that match the characteristics of the original profiles. Further, this generator can be used to populate load profiles in areas where actual measurements are limited to improve the ability of utilities to analyze their distribution systems. By providing more high-resolution residential building load profiles, this tool supports electric utilities to enhance their residential building load control strategies and improve overall grid stability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Loads assessment of a fixed-bottom offshore wind farm with wake steering

Wake steering via deliberate yaw offset is an emerging wind farm control technique that has the potential to mitigate wake losses and further increase wind farm energy yield. The loads impact of this technique has been studied, but there is limited insight into wind-farm-wide impacts of wake steering. Understanding such impacts is crucial to determining the feasibility of using wake steering in commercial wind farms. To that end, this work investigates the impacts of wake steering on the loads of all turbine components across all turbines in a wind farm operating under a broad set of inflow conditions, including inflow velocity, shear exponent, turbulence class, and inflow angle. This was done by performing FAST.Farm simulations of a 12-turbine wind farm array, excerpted from a larger hypothetical wind farm. The International Energy Agency Wind 15-MW reference wind turbine was modeled atop a monopile substructure, an open-source model that closely approximates the properties of similar commercial options. Wake steering was included via yaw offsets that were computed using an offline optimization with the National Renewable Energy Laboratory tool FLORIS. For each inflow case, the 12-turbine array was simulated with and without wake steering. Results were compared in terms of time-averaged means, standard deviations, ultimate loads, and damage-equivalent loads. The findings show that because wake steering is generally applied at rated wind speeds and below, it is unlikely to drive ultimate loads. For fatigue loads, wake steering does increase the overall fatigue accumulation for some load channels, such as blade-root and shaft bending. This is to be expected when overall power yield increases but may cause the damage accumulation to be more uniform throughout the array. The significance of the added fatigue loading is dependent on how frequent wake steering is utilized in the overall set of inflow conditions across the wind rose.

17 WIND ENERGY↗

Solid face sheets enable lattice metamaterials to withstand high-amplitude impulsive loading without yielding

Owing to their ability to provide tunable mechanical responses, lattice materials are frequently studied to elucidate their response to static and dynamic loads. However, these roles are typically in opposition: static loads must be supported sufficiently far away from the onset of buckling or yielding, whereas dynamic loads are typically ameliorated by crushing of the lattice, which provides excellent energy-absorption due to the large plastic deformation accompanying densification. In contrast, this work considers the octet truss as an exemplar topology, in a structural role where it must simultaneously support static loads while enduring high-amplitude impulsive loads. This study focuses on the ability to withstand impulsive loads without yielding, an essential prerequisite to enduring dual loading. Computational studies using the ALE3D hydrocode were performed to examine the response of the octet truss under a short temporal width impulse shape associated with laser-driven shocks. A key finding was that covering the lattice with a solid face sheet and treating this face sheet thickness as a design variable allows the Taylor-like pulse to be attenuated prior to entering the weaker lattice, at the cost of added mass up front. Experimental validation was accomplished by laser-driven shock testing, using octet trusses printed out of Ti-5Al-5V-5Mo-3Cr. The results show that for a given quantity of mass, the attenuation is maximized when as much mass as possible is moved into the face sheet, leaving a more slender lattice structure. The effect of placing mass in the face sheet rather than lattice beams dominates the effect of relative density, to the point where a low-mass structure with most of the mass concentrated in the face sheet can outperform a high-mass structure with most of the mass in the lattice. Finally, by further understanding the propagation of short pulse width waves within under-dense structures, this study expand the domain of applicability of such structures, including lattice materials, to challenging dual-loading regimes spanning decades of strain rates.

36 MATERIALS SCIENCE↗

Impact of Porous Transport Layer Morphology on the Performance of Proton Exchange Membrane Water Electrolyzers with Ultra-Low Iridium Loadings

Reducing Ir loadings in proton exchange membrane water electrolyzer anodes is critical for lowering capital expenses. Loading reduction could be achieved by improving the Ir activity via doping/alloying and/or the development of advanced microstructures. However, the anode porous transport layer (PTL) is a comparatively simple component whose properties also impact Ir utilization. Therefore, well-designed PTLs may also enable reduced Ir loadings. In this work, we survey eight PTLs from various manufacturers to observe their impact on cell performance at low (0.4 mg Ir cm -2 ) and ultralow (0.1 mg Ir cm -2 ) Ir loadings. The PTLs were characterized by their microstructural properties, including porosity, particle size distribution, and pore size distribution. Electrochemical cell performance was correlated to PTL morphology, and it was found that PTLs with lower porosities and smaller particle and pore radii enabled good performance even at ultralow Ir loadings. 1000-h durability testing indicated that using lower porosity PTLs can significantly improve durability behavior. A runaway voltage phenomenon was observed during durability testing of cells with ultralow Ir loadings, which was caused by increases in both anode and cathode overpotentials. Furthermore, we observed that the beginning of test performance of 0.1 mg Ir cm -2 cells correlates to the 1000-h degradation rates of 0.4 mg Ir cm -2 cells, suggesting that for the Ir catalyst used in this work, short-term testing at ultralow loadings can be used as an indicator of long-term degradation at higher loadings.

08 HYDROGEN↗

Instantaneous mesh load factor ( K γ ) measurements in a wind turbine gearbox using fiber-optic strain sensors

The mesh load factor, K γ , describes how loads are shared between planet gears and has become one of the key design challenges in modern wind turbine gearboxes. Planet load sharing directly impacts tooth root stresses, a critical driver of torque density and gearbox reliability. Experimental evaluation of K γ is typically performed from sun gear tooth root strain gauge measurements, which are complex. Furthermore, such measurements can only provide an average value of load sharing. The present study describes an alternative method to evaluate the mesh load factor in wind turbine gearboxes based on fiber-optic strain sensors installed on the outer surface of the fixed ring gear. We present the results of an extensive measurement campaign to evaluate this novel sensing solution installed on the input planetary stage of a 2-MW wind turbine gearbox at the National Renewable Energy Laboratory's Flatirons Campus (Colorado, USA). The number of strain sensors on the ring gear was selected as an integer multiple of the number of planets, which has enabled an instantaneous evaluation of the mesh load factor. The effect of operating conditions on the planet load-sharing behavior of the gearbox has been investigated. The mesh load factor measured for operating conditions close to rated was below 1.05, well below IEC 61400-4 standard requirements.

17 WIND ENERGY↗

Harmonic Modeling, Data Generation and Analysis of Power Electronics-Interfaced Residential Loads

The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.

harmonics, power quality, load modeling↗

Heliostat Consortium: Gap Analysis on State of the Art in Wind Load Design

Wind loads are a major driver of heliostat cost. Standardized methods and tools are needed for a more detailed understanding of the static and dynamic loads of a heliostat design. This will enable cost reduction of wind-dependent heliostats to avoid unnecessarily conservative heliostat designs and increase field efficiency and reliability to reduce the risk of component failures due to high-wind events. Gaps related to wind load include lack of site characterization for wind measurements, insufficient critical load cases for heliostat design, insufficient understanding of turbulence impacts on heliostat tracking error, lack of knowledge on wind load under various heliostat array configurations, and underexplored heliostat field wind-load reduction and operating strategies. Recommended pathway forward is to develop wind load and site characterization guidelines for heliostat design and develop heliostat field wind-load models with optical performance impacts.

aerodynamics↗

Validation of Local Structural Loads Computed by OpenFAST Against Measurements From the FOCAL Experimental Campaign

This work presents the validation of the local structural load modeling capability in OpenFAST for floating substructures based on data from the FOCAL experimental campaign. Previously, OpenFAST could only represent the floating substructure as a rigid body, and though this approach can model the global response of the floater in most cases, it is not able to capture the structural loads within the floater's individual members. Consideration of local substructure loads is important for some floating designs, because the pursuit of cost reduction often results in lighter and more flexible structures. To address this limitation, the HydroDyn (hydrodynamics) and SubDyn (substructure dynamics) modules of OpenFAST have been recently extended to account for the flexibility of floating substructures. To validate this new capability, we compare the results obtained by OpenFAST with data measured during the FOCAL experimental campaign, which analyzed a 1:70 scale performance-matched model of the IEA 15-MW reference turbine atop a modified University of Maine VolturnUS-S semisubmersible in a wave basin under the action of both wind and waves. For the purposes of the present work, the most important feature of the experiment is the presence of load cells at the root of each pontoon, and our objective is to assess how well those loads are reproduced by OpenFAST. To model the distributed hydrodynamic and hydrostatic loads along the floating substructure, we adopt a strip-theory approach based on the Morison equation, and we discuss the impact of different hydrodynamic modeling options (wave stretching, MacCamy-Fuchs correction, and second-order wave kinematics) on both motions and loads. For simplicity, we focus on wave-only conditions, both regular and irregular. The results demonstrate good overall agreement for the loads at the root of the pontoons for the waves analyzed in this work, especially given the assumptions and simplifications inherent to a simple strip-theory model.

floating offshore wind turbine↗

Commercialization of Distribution System Load Modeling Tool for Improved DER Interconnection Studies

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

14 SOLAR ENERGY↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services

Flexible loads have great potential to improve the electric grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. This paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environmental impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

61 RADIATION PROTECTION AND DOSIMETRY↗

Wind Turbine Gust Load Alleviation with Active Flow Control

Large wind turbine rotors are becoming more common in utility-scale wind power, especially for offshore wind plants. However, the trend toward large rotors can be limited by their ability to manage dynamic and extreme loads. To provide a safety margin for the rotor design and avoid catastrophic events such as tower strikes, extreme loads need to be controlled. The objective of this study is to develop and evaluate a feedback control system to alleviate extreme loads and reduce blade deflections under gust events using active flow control devices. We also propose a modification in the turbine controller to achieve further reduction in extreme loads. The extreme load reductions are evaluated under gust wind conditions with direction changes according to the IEC standard. The effects of the gust alleviation controller on turbine performance and fatigue loads are investigated as well. With the deployment of the gust alleviation controller and modified turbine baseline controller, the extreme loads and deflections reduce by up to 23%. The energy captured by the turbine is not affected by the proposed gust alleviation controller. The fatigue loads of various wind turbine components are either reduced or remain unchanged.

17 WIND ENERGY↗

Impacts of wind field characteristics and non-steady deterministic wind events on time-varying main-bearing loads

Abstract. This work considers the characteristics and drivers of the loads experienced by wind turbine main bearings. Simplified load response models of two different hub and main-bearing configurations are presented, representative of both inverting direct-drive and four-point-mounted geared drivetrains. The influences of deterministic wind field characteristics, such as wind speed, shear, yaw offset, and veer, on the bearing load patterns are then investigated for similarity scaled 5, 7.5, and 10 MW reference wind turbine models. Main-bearing load response in cases of deterministic gusts and extreme changes in wind direction are also considered for the 5 MW model. Perhaps surprisingly, veer is identified as an important driver of main-bearing load fluctuations. Upscaling results indicate that similar behaviour holds as turbines become larger, but with mean loads and load fluctuation levels increasing at least cubically with the turbine rotor radius. Strong links between turbine control and main-bearing load response are also observed.

17 WIND ENERGY↗

Comparison of Two Load Prediction Methods for Strain-Gage Balances

Data from a five-component semi-span balance is used to perform a systematic comparison of the load prediction accuracy of two load prediction methods. Both methods independently obtain the load prediction equations from multivariate least squares fits of balance calibration data. The first method is called the Non-Iterative Method. This approach directly uses regression models of the individual load components of a balance for the load prediction. The second method is called the Iterative Method. This alternate approach uses a load iteration equation for the load prediction that is constructed from the regression coefficients of the gage outputs of the balance. Basic characteristics of the two methods are reviewed. Afterwards, both methods are applied to calibration, check load, and wind tunnel test data of a five-component semi-span balance. Selected analysis results are compared. These comparisons confirm that the accuracy of the two methods is the same for all practical purposes.

strain-gage balance↗

Effect of Loading Rate on the Open Hole Compression Strength of Quasi-Isotropic Carbon/Epoxy Laminates

This study was undertaken to examine how well the 0.05 inch/min loading rate typically used to develop allowables for open hole compression strength of carbon/epoxy laminates represents structures that may experience a much lower loading rate (such as civil engineering structures) or a much higher loading rate (such as a rocket interstage at liftoff). The Composite Materials Handbook-17 (CMH-17) suggests developing strength allowables at the coupon level (lowest level of the “building block” approach) and using a rigorous statistical analysis to arrive at a strength allowable upon which the structure is to be further designed at higher levels of the building block pyramid. But do these coupon level tests truly represent meaningful stresses at which the composite in the final structure can withstand considering the effects of loading rate? Open hole compression (OHC) strength was chosen for this study since most structures are designed to some damage tolerance criteria and OHC strength testing is rather simple to perform. A quasi-isotropic lay-up was chosen since this is a very common lay-up sequence. The results show that for structures that experience a very small loading rate (0.0005 in/min) the allowables developed at the standard 0.05 in/min loading rate are higher than what the composite can withstand at this lower loading rate. Conversely, at a high loading rate of 10 in/min the strength values found at the standard test rate of 0.05 in/min are slightly lower and not “in family” using the statistics suggested in CMH-17. These results question if standardized test rates are reliable, at least to the fidelity of being “in family” per CMH-17. Some creep rupture tests were also performed to demonstrate that OHC strength values could be lower than the slowest test speed used in this study (0.0005 in/min).

open hole compression strength↗

Uneven Inflation Load Share Trends in Clusters

The use of parachute clusters for payload recovery is still seeing widespread use ever since the early days of WWII. By involving the (near) simultaneous deployment of several smaller and identical canopies connected to the payload, cluster systems offer flexibility in tailoring to needed descent rates and load management, as well as providing robustness against individual canopy deployment or opening failure. Their downside, of course, resides in the possibility of differing inflation rates by each cluster member as caused by deployment variability, canopy-to-canopy interference, etc. Such variability leads to the lead-lag phenomenon, which causes uneven loading among the parachutes, often times leaving a single canopy to take up a significant portion of the system’s inflation loads. Herein we investigate how serious such an effect can be in terms of the number N of cluster members, underinflation drag of the lagging canopies, inflation swiftness of the leader in comparison to the laggards’, disreefing cutter activation staggering and pre-disreefing drag area. Two new metrics are used to highlight load share unevenness, namely, the peak and average leader canopy riser load in comparison to the leader’s drag during no-lead-lag; and leader peak load, as compared to total peak load. Results are calculated from data collected in NASA’s Orion/CPAS test program, as well as from simple algebraic expressions informing leader drag as sustained in different cluster systems (i.e., of different N) and varying leader inflation time relative to the laggards. Generally, using large-N cluster systems confers better load sharing among canopies. However, and in deployments where significant lead-lag occur, large-N systems may feature greater leader overload excursions, oftentimes in excess of 50% the no-lead-lag levels. These excursions are particularly made worse when cutter activation among the members are far from simultaneous and the laggards’ pre-disreefing drag area is small in comparison to the leader’s.

parachutes↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services: Preprint

Flexible loads have great potential to improve the power grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. The paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environment impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

control↗

Validation of Local Structural Loads Computed by OpenFAST Against Measurements From the Focal Experimental Campaign: Preprint

This work presents the validation of the local structural load modeling capability in OpenFAST for floating substructures based on data from the FOCAL experimental campaign. Previously, OpenFAST could only represent the floating substructure as a rigid body, and though this approach can model the global response of the floater in most cases, it is not able to capture the structural loads within its individual members. Consideration of local substructure loads is important for some floating designs, as the pursuit of cost reduction often results in lighter and more flexible structures. To address this limitation, the HydroDyn (hydrodynamics) and SubDyn (substructure dynamics) modules of OpenFAST have been recently extended to account for the flexibility of floating substructures. To validate this new capability, we compare the results obtained by OpenFAST with data measured during the FOCAL experimental campaign, which analyzed a 1:70 scale performance-matched model of the IEA 15-MW reference turbine atop a modified University of Maine VolturnUS-S semisubmersible in a wave basin under the action of both wind and waves. For the purposes of the present work, the most important feature of the experiment is the presence of load cells at the root of each pontoon, and our objective is to assess how well those loads are reproduced by OpenFAST. To model the distributed hydrodynamic and hydrostatic loads along the floating substructure, we adopt a strip-theory approach based on the Morison equation, and we discuss the impact of different hydrodynamic modeling options (wave stretching, MacCamy-Fuchs correction, and second-order wave kinematics) on both motions and loads. For simplicity, we focus on wave-only conditions, both regular and irregular. The results demonstrate good overall agreement for the loads at the root of the pontoons for the waves analyzed in this work, especially given the assumptions and simplifications inherent to a simple strip-theory model.

floating offshore wind turbine↗