Root Cause Analysis of Degradation in Protonic Ceramic Electrochemical Cell with Interfacial Electrical Sensors Using Data‐Driven Machine Learning

Abstract Protonic ceramic electrochemical cells (PCECs) offer promising paths for energy storage and conversion. Despite considerable achievements made, PCECs still face challenges such as physiochemical compatibility between componenets and suboptimal solid–solid contact at the interfaces between the electrolytes and electrodes. In this study, a novel approach is proposed that combines in situ electrochemical characterization of interfacial electrical sensor embedded PCECs and machine learning to quantify the contributions of different cell components to total degradation, as well as to predict the remaining useful life. The experimental results suggest that the overpotential induced by the oxygen electrode is 48% less than that of oxygen electrode/electrolyte interfacial contact for up to 1171 h. The data‐driven machine learning simulation predicts the RUL of up to 2132 h. The root cause of degradation is overpotential increase induced by oxygen electrode, which accounts for 82.9% of total cell degradation. The success of the failure diagnostic model is demonstrated by its consistency with degradation modes that do not manifest in electrolysis fade during early real operations. This synergistic approach provides valuable insights into practical failure diagnosis of PCECs and has the potential to revolutionize their development by enabling improved performance prediction and material selection for enhanced durability and efficiency.

25 ENERGY STORAGE↗

Endpoint Slippage Analysis in the Presence of Impedance Rise and Loss of Active Material

Endpoint slippage analysis can be used to quantify the reduction and oxidation side-reactions occurring in rechargeable batteries. Application of this technique often disregards the interference of additional aging modes, such as impedance rise and loss of active material (LAM). Here, we show that these modes can themselves induce slippage of endpoints, making the direct determination of parasitic reactions more difficult. We provide equations that describe the slippages caused by LAM and impedance rise. We show that these equations can, in principle, account for the contribution of these additional modes to endpoint slippage, enabling “correction” of testing data to quantify the side-reactions of interest. However, the challenge with this approach is that it requires information about the average Li+ content of disconnected active material domains, which is, in many cases, unknowable. The present work explores mathematical connections between measurable quantities (such as capacity fade and endpoint slippages) and the extent of LAM or impedance rise endured by the cell, and discuss how the tracking of endpoints can better serve battery diagnostics.

Rodrigues, Marco-Tulio F. [Argonne National Labora↗

Toward the Development of Molten Salt Reactor Diagnostics based on Resonantly Enhanced Laser Spectroscopy

One emerging concern within the safeguards community is how to best ensure compliance with nuclear security regulations within molten salt reactor (MSR) facilities. This problem is nontrivial as molten salts used for fuel or coolant are highly corrosive, chemically complex, and inherently require high operational temperatures. Laser spectroscopy methods such as laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF) have previously been suggested for molten salt diagnostics due to their compatibility with liquid phase samples and potential for in-situ measurements [1]. In the former, the laser is used to ionize the sample, allowing for the characteristic light from electronic de-excitation as the resultant plasma cools to be used for material characterization. In the latter, a tunable light source is set be resonant with a specific transition, resulting in element specific excitation and the emission of fluorescence light. In our previous work [2], we demonstrated that LIF could be used for the detection of fission fragments such as Nd in solution through the separation of laser scatter and fluorescence within the time domain. Here, we present progress towards two alternate measurement schemes: LIF measurements based on spectroscopic discrimination of fluorescence emissions and resonant LIBS measurements that induce plasma using a light source set to the resonant frequency of a specific electronic transition. Both methods aim to exploit resonant excitation methods to enhance the emitted signal. The studies may provide routes for element-specific detection of constituents within complicated matrices and a means to better understand the chemical behavior of lanthanides and actinides relevant to MSRs.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Optimizing ablator thickness for laser shock experiments

In laser shock experiments, a well-defined, flat-top shock wave at the ablator/sample interface is important for accurately probing material response under uniaxial strain compression. However, the relationship between the ablator thickness and the resulting shock wave characteristics is insufficiently understood, limiting the ability to design optimal experiments. To address this need, we conducted a systematic experimental study using a 100 J laser to shock-compress polyimide ablators to peak stresses ranging from 20.4 to 111.6 GPa. Laser interferometry diagnostics measured the transmitted wave profiles at the ablator/sample interface, consistently showing a single jump followed by a constant peak state before the arrival of release waves. Here, by analyzing shock transit time, flat-top duration, and stress, our results establish a framework for selecting ablator thickness to maximize the flat-top duration, improving the precision and reproducibility of laser shock experiments.

design of experiments↗

Battery state-of-health diagnostics during fast cycling using physics-informed deep-learning

Rapid, in-situ Li-ion battery state-of-health (SOH) quantification is challenging. Li-ion battery aging can vary significantly with chemistry, operating conditions, cycling demands, electrode design, and operation history. As a cell ages, optimal and safe operating conditions need to be adapted to account for battery degradation by tracking critical aging modes such as loss-of-lithium-inventory (LLI), loss-of-active-material (LAM) in either electrode, and/or impedance rise. This manuscript describes a framework for identifying battery aging modes in-operando using fast-rate voltage charge/discharge responses. The framework uses a physically based Li-ion battery model to produce synthetic high-rate responses at aged states. The aging model is calibrated against experimental data from cells with different electrode loadings and cycled under a variety of fast-charging conditions (1 h, 15 min, 10 min, and 7 min charging). The synthetically generated high-rate responses at aged states are then used to train a deep-learning model to identify real cell state-of-health from fast charge/discharge battery voltage responses. The synthetically trained deep-learning model performance is validated by comparing to standard incremental capacity analysis and half-cell measurements. Finally, the framework demonstrates the benefits of using high-rate physics-based models to generate synthetic data for training deep-learning models.

25 ENERGY STORAGE↗

Chapter 6: Thermoelectric Energy Harvesters and Applications

With recent progress in the field of wearable and bio-integrated devices, which are widely used for various applications, such as real-time health monitoring, point-of-care diagnostics, and biological actuators, the need for a continuous and reliable power source is increasing. As solid-state devices with no moving parts, thermoelectric energy generators provide a reliable solution for harnessing body heat and converting it into electricity on demand. However, traditional thermoelectric generators, comprising inorganic materials, are rigid and bulky, limiting their wide deployment. Nonconventional thermoelectric generators, composed of organic and hybrid thermoelectric materials, are flexible and lightweight. In this chapter, we will discuss the working principle of thermoelectric energy harvesting, including materials, devices, and applications. While we briefly touch upon the inorganic materials, we will focus primarily on the organic and hybrid materials, which are nontoxic, flexible, easy to manufacture, easy to scale, and readily available at low cost, providing a promising solution for lightweight and conformal thermoelectric power generation.

body heat harvesting↗

Mass transport limitations in polymer electrolyte water electrolyzers using spatially-resolved current measurement

Here this work utilizes spatially-resolved current measurements to provide insight into mass transport limitations in electrolyzers that are not observable from traditional polarization measurement. In this study, two types of flow-fields (parallel and triple-serpentine) and two types of diffusion media (patterned porous thin titanium foil LGDLs and Ir-coated titanium felt PTLs) were examined. A non-uniform current distribution dominated by mass transport limitations was observed to be instigated by the restriction of liquid water transport to catalyst sites. Additionally, conditions are revealed which yield similar polarization performance but dissimilar current distributions. In such cases, the transport limitations for different architectures and porous media affect polarization in different regions of the active area. Furthermore, the triple-serpentine flow-field used in this study performs better than the parallel flow-field under mass transport limited operating conditions. This indicates that the parallel flow-field used in this study is more susceptible to starvation than the triple-serpentine flow-field for the electrolyzer studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laser-metal interaction dynamics during additive manufacturing resolved by detection of thermally-induced electron emission

In situ monitoring is required to improve the understanding and increase the reliability of additive manufacturing methods such as laser powder bed fusion (LPBF). Current diagnostic methods for LPBF capture optical images, X-ray radiographs, or measure the emission of thermal or acoustic signals from the component. Herein, a methodology based on the thermal emission of electrons - thermionic emission - from the metal surface during LPBF is proposed which can resolve laser-material interaction dynamics. The high sensitivity of thermionic emission to surface temperature and surface morphology is revealed to enable precise determination of the transition between conduction and keyhole mode melting regimes. Increases in thermionic emission are correlated to laser scanning conditions that give rise to pore formation and regions where surface defects are pronounced. The information presented here is a critical step in furthering our understanding and validation of laser-based metal additive manufacturing.

36 MATERIALS SCIENCE↗

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources

With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.

47 OTHER INSTRUMENTATION↗

Toward “super-scintillation” with nanomaterials and nanophotonics

Abstract Following the discovery of X-rays, scintillators are commonly used as high-energy radiation sensors in diagnostic medical imaging, high-energy physics, astrophysics, environmental radiation monitoring, and security inspections. Conventional scintillators face intrinsic limitations including a low extraction efficiency of scintillated light and a low emission rate, leading to efficiencies that are less than 10 % for commercial scintillators. Overcoming these limitations will require new materials including scintillating nanomaterials (“nanoscintillators”), as well as new photonic approaches that increase the efficiency of the scintillation process, increase the emission rate of materials, and control the directivity of the scintillated light. In this perspective, we describe emerging nanoscintillating materials and three nanophotonic platforms: (i) plasmonic nanoresonators, (ii) photonic crystals, and (iii) high-Q metasurfaces that could enable high performance scintillators. We further discuss how a combination of nanoscintillators and photonic structures can yield a “super scintillator” enabling ultimate spatio-temporal resolution while enabling a significant boost in the extracted scintillation emission.

Carr Delgado, Hamish↗

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of multiple heat flux components at the divertor target by using surface eroding thermocouples (invited)

The Surface Eroding Thermocouple (SETC) is a robust diagnostic utilized in DIII-D to provide fast, edge-localized modes (ELMs) resolved heat flux measurements, in particular in geometric regions that are too shadowed for traditional infrared thermography. In order to further investigate the power dissipation in the divertor region, a combination of flush-mounted and recessed SETCs was developed to assess the effect on surface heating from non-charged particles at the divertor target. Utilizing the Divertor Materials Evaluation System sample exposure platform, the first demonstration of the feasibility of using this new method to distinguish between the heat flux from charged particles and that from neutrals and radiative heating was achieved. This paper details the process of using the combination of flush SETCs and recessed SETCs to measure the multiple heat flux components at the divertor target and further discusses how to determine two important ratios, α (ratio of heat flux from charged particles deposit on recessed SETC to that deposit on flush SETC) and β (ratio of heat flux from non-charged particles deposit on recessed SETC to that deposit on flush SETC), in the estimation of the heat flux from non-charged particle sources. Using a time dependent ratio α, it was found that ~50% of the total incident heat flux is attributable to the non-charged particles in the fully detached open divertor in DIII-D. Finally, the new application of similar SETC diagnostics in the Small Angle Slot divertor with a V-like configuration and partial tungsten coated surface (SAS-VW) is also introduced.

47 OTHER INSTRUMENTATION↗

Hydro-scaling of direct-drive cylindrical implosions at the OMEGA and the National Ignition Facility

Deceleration-phase Rayleigh–Taylor instability (RTI) growth during inertial confinement fusion capsule implosions significantly affects the performance as it mixes cold ablator material into the fuel. Precise measurements of such instability growth are essential for both validating the existing simulation codes and improving our predictive capability. RTI measurements on the inner surface of a spherical shell are limited and are often inferred indirectly at limited convergence. In contrast, cylindrical implosions allow for direct diagnostic access to the converging interface by imaging down the cylinder axis while retaining the effects of convergence. We have performed direct-drive cylindrical implosion experiments at both the OMEGA and the NIF laser facilities using scaled targets. RTI growth is demonstrated to be scale-invariant between the cylindrical targets at OMEGA and similar targets at the NIF, which are scaled up by a factor of three in the radial dimension. Single-mode (m = 0) instability growth factors of ~14 are measured at a convergence ratio (CR) ~ 2.5 with nearly identical mode growth at both scales. The measurements are in agreement with xRAGE radiation-hydrodynamics simulations. In addition, we have developed the Bayesian-inference-engine method to account for the variations in the target alignment, magnification, and the parallax effect in the measurement, allowing a more precise comparison between the experimental data and the simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of magnetic angle on the E × B drift in a magnetic presheath

In this work, we provide experimental measurements of the E X B flow above a non-magnetic, absorbing boundary in a magnetized plasma. Measurements are taken as a function of the angle between the background magnetic field and the boundary normal. The measurements are compared to computational predictions for oblique magnetic fields based on Chodura's model. Ion flow measurements were obtained with laser induced fluorescence and the presheath potential structure was measured with an emissive probe. The ions were found to accelerate to nearly 30% of the sound speed parallel to the boundary at oblique angles of the magnetic field (~80°) and the ion speed at the electrostatic sheath edge was found to decrease with angle. The edge of the magnetic presheath has been experimentally determined based on the appearance of the E X B drift and is found to be independent of the angle of the magnetic field. We also demonstrate that laser induced fluorescence is suitable as a non-perturbative diagnostic to measure the electric field in a magnetized sheath.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics Goals of DWA Experiments at FACET-II

The dielectric wakefield acceleration (DWA) program at FACET produced a multitude of new physics results that range from GeV/m acceleration to the discovery of high field-induced conductivity in THz waves, and beyond, to a demonstration of positron-driven wakes. Here we review the rich program now developing in the DWA experiments at FACET-II. With increases in beam quality, a key feature of this program is extended interaction lengths, near 0.5 m, permitting GeV-class acceleration. Detailed physics studies in this context include beam breakup and its control through the exploitation of DWA structure symmetry. The next step in understanding DWA limits requires the exploration of new materials with low loss tangent, large bandgap, and improved thermal characteristics. Advanced structures with photonic features for mode confinement and exclusion of the field from the dielectric, as well as quasi-optical handling of coherent Cerenkov signals is discussed. Use of DWA for laser-based injection and advanced temporal diagnostics is examined.

43 PARTICLE ACCELERATORS↗