Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Method for improving the angular resolution of a neutron scatter camera

An instrument that will directly image the fast fission neutrons from a special nuclear material source wherein the neutron detection efficiency is increased has been described. Instead of the previous technique that uses a time-of-flight (TOF) between 2 widely spaced fixed planes of neutron detectors to measure scatter neutron kinetic energy, we now use the recoil proton energy deposited in the second of the 2 scatter planes which can now be repositioned either much closer together or further apart. However, by doubling the separation distance between the 2 planes from 20 cm to a distance of 40 cm we improved the angular resolution of the detector from about 12.degree. to about 10.degree.. A further doubling of the separation distance to 80 cm provided an addition improvement in angular resolution of the detector to about 6.degree. without adding additional detectors or ancillary electronics. The distance between planes also may be dynamically changed using a suitable common technique such as a gear- or motor-drive to toggle between the various positions. The angular resolution of this new configuration, therefore, is increased at the expanse of detection sensitivity. However, the diminished sensitivity may be acceptable for those applications where the detector is able to interrogate a particular site for an extended period.

47 OTHER INSTRUMENTATION↗

The Closed Orbit Measurement System at the DELTA Synchrotron Radiation Facility And First Investigations Concerning the Installation of a Beam Based BPM Calibration System

For a synchrotron radiation source it is necessary to operate a monitoring system to determine the beam position with high resolution and accuracy with respect to the axis of the quadrupole magnets. In this paper the present closed orbit measurement system of the DELTA SR-Facility, concerning the hardware setup, data processing and the calibration methods, will be presented. The results of the calibration measurements and the recent operating experience will be discussed. These results show, that the system is close to the design resolution. But the BPM offsets with respect to the magnetic center of the quadrupole magnets turn out to be not acceptable. For some BPMs they are in the order of several 100 micro m. Therefore it was decided to install a beam based BPM calibration system in the near future . This system should allow to determine the BPM offsets relative to the center of the quadrupole magnets for all 40 BPMs. It is planned to install a system in order to change the focussing strength of each quadrupole individually either in a static or dynamic way.

43 PARTICLE ACCELERATORS↗

Fast Integer Ambiguity Resolution for GPS Attitude Determination

In this paper, a new algorithm for GPS (Global Positioning System) integer ambiguity resolution is shown. The algorithm first incorporates an instantaneous (static) integer search to significantly reduce the search space using a geometric inequality. Then a batch-type loss function is used to check the remaining integers in order to determine the optimal integer. This batch function represents the GPS sightline vectors in the body frame as the sum of two vectors, one depending on the phase measurements and the other on the unknown integers. The new algorithm has several advantages: it does not require an a-priori estimate of the vehicle's attitude; it provides an inherent integrity check using a covariance-type expression; and it can resolve the integers even when coplanar baselines exist. The performance of the new algorithm is tested on a dynamic hardware simulator.

Lightsey, E. Glenn↗

Carbon-enhanced metal-poor star candidates from BP/RP spectra in Gaia DR3

ABSTRACT Carbon-enhanced metal-poor (CEMP) stars comprise almost a third of stars with [Fe/H] < −2, although their origins are still poorly understood. It is highly likely that one sub-class (CEMP-s stars) is tied to mass-transfer events in binary stars, while another sub-class (CEMP-no stars) are enriched by the nucleosynthetic yields of the first generations of stars. Previous studies of CEMP stars have primarily concentrated on the Galactic halo, but more recently they have also been detected in the thick disc and bulge components of the Milky Way. Gaia DR3 has provided an unprecedented sample of over 200 million low-resolution (R ≈ 50) spectra from the BP and RP photometers. Training on the CEMP catalogue from the SDSS/SEGUE database, we use XGBoost to identify the largest all-sky sample of CEMP candidate stars to date. In total, we find 58 872 CEMP star candidates, with an estimated contamination rate of 12 per cent. When comparing to literature high-resolution catalogues, we positively identify 60–68 per cent of the CEMP stars in the data, validating our results and indicating a high completeness rate. Our final catalogue of CEMP candidates spans from the inner to outer Milky Way, with distances as close as r ∼ 0.8 kpc from the Galactic centre, and as far as r > 30 kpc. Future higher resolution spectroscopic follow-up of these candidates will provide validations of their classification and enable investigations of the frequency of CEMP-s and CEMP-no stars throughout the Galaxy, to further constrain the nature of their progenitors.

79 ASTRONOMY AND ASTROPHYSICS↗

Airborne gravity and other geophysical techniques for understanding the lithosphere beneath the West Antarctic Ice Sheet

As part of a program entitled Corridor Aerogeophysics of the Southeastern Ross Transect Zone (CASERTZ), an aerogeophysical platform was developed to study the interaction of geological and glaciological processes in West Antarctica. A de Havilland Twin Otter was equipped with an ice-penetrating radar, a proton precession magnetometer, an airborne gravity system, and a laser altimeter. The 60-MHz ice-penetrating radar can recover sub-ice topography with an accuracy of about 10 m through 3 km of comparatively warm West Antarctic ice, while the laser altimeter profiling of the ice surface is accurate to approximately 1 m. The magnetic field observations are accurate to several nT, and the gravity measurements are accurate to better than 3 mGal. The aircraft is navigated by a local radio transponder network, while differential positioning techniques based on the Global Positioning System (GPS) satellites are used for recovering high-resolution horizontal and vertical positions. Attitude information from an inertial navigation system is used to correct the laser altimetry and a digital pressure transducer is used to recover vertical positions and accelerations in the absence of satellite positioning. Continuous base-station observations are made for the differential GPS positioning and the removal of ionospheric noise from the airborne magnetometer measurements.

Bell, Robin E.↗

Molybdenum-silicon multilayer mirrors for the extreme ultraviolet

Multilayer structures of molybdenum and silicon have been synthesized by sputter deposition onto flat silicon single-crystal silicon substrates and spherically ground (0.5and 22.0-m radii) fused silica substrates; and the reflectivities for 170.4-A (72.8-eV), 160.1-A (77.4-eV), and 228-A (54.4-eV) light measured at near normal incidence. Observed peak values ranged from 26.2 to 78 percent, the highest reflectivities occurring closest to normal incidence. Energy resolutions were about 10 in all cases. Model calculations were performed using optical constants and experimentally determined multilayer structural parameters. In all cases the measured reflectivities were equal to or larger (by up to a factor of 2) than the calculated values, a result attributed to uncertainty in the optical constants used in the calculations. Experimental and calculated angular-peak positions and energy resolutions were in good agreement. The high reflectivities of these molybdenum-silicon structures will make possible application of traditional optics approaches in the EUV and support new developments including free-electron lasers.

Barbee, T. W., Jr.↗

Resolution study of higher-order-mode-based beam position diagnostics using custom-built electronics in strongly coupled 3.9-GHz multi-cavity accelerating module

Beam-excited higher order modes (HOMs) can provide remote diagnostics information of the beam position and cavity misalignment. In this paper we report on recent studies on the resolution with specially selected series of modes with custom-built electronics. This constitutes the first report of measurements of these cavities in which we obtained a resolution of 20 micron in beam offset. Details of the setup of the electronics and HOM measurements are provided.

43 PARTICLE ACCELERATORS↗

Validation of velocity map imaging conditions over larger areas

We have established through simulations and experiments the area over which Velocity Map Imaging (VMI) conditions prevail. We designed a VMI setup in which we can vary the ionization position perpendicular to the center axis of the time-of-flight spectrometer. We show that weak extraction conditions are far superior over standard three-plate setups if the aim is to increase the ionization volume without distorting VMI conditions. This is important for a number of crossed molecular beam experiments that already utilize weak extraction conditions, but to a greater extent for surface studies where fragments are desorbed or scattered off a surface in all directions. Our results on the dissociation of NO{sub 2} at 226 nm show that ionization of the fragments can occur up to {+-}5.5 mm away from the center axis of the time-of-flight spectrometer without affecting resolution or arrival position.

43 PARTICLE ACCELERATORS↗

A color x-ray camera for 2–6 keV using a mass produced back illuminated complementary metal oxide semiconductor sensor

There are several reports in the scientific literature of the use of mass-produced charge coupled device or complementary metal oxide semiconductor (CMOS) sensors as x-ray detectors that combine high spatial resolution with significant energy resolution. Exploiting a relatively new especially favorable ambient-temperature back-illuminated CMOS sensor, we report the development of a spectroscopic x-ray camera having particularly impressive performance for 2-6 keV photons. This instrument has several beneficial characteristics for advanced x-ray spectroscopy studies in the laboratory, at synchrotron light sources, at x-ray free electron lasers, or when using pulsed x-ray sources such as for laser plasma physics research. These characteristics include fine position and energy resolution for individual photon events, high saturation rates, frame rates above 100 Hz, easy user maintenance for damaged sensors, and software for real-time processing. We evaluate this camera as an alternative to traditional energy-dispersive solid-state detectors, such as silicon drift detectors, and also illustrate its use in a very high resolution wavelength-dispersive x-ray fluorescence spectrometer (i.e., x-ray emission spectrometer) that has recently been reported elsewhere [W. M. Holden et al., Rev. Sci. Instrum. 88(7), 073904 (2017)].

47 OTHER INSTRUMENTATION↗

The Energy Exascale Earth System Model Simulations With High Vertical Resolution in the Lower Troposphere

Abstract General circulation models (GCMs) are typically run with coarse vertical resolution. For example, the Energy Exascale Earth System Model (E3SM) has a vertical resolution of about 200 m in the boundary layer, which is far too coarse to resolve sharp gradients often found in the thermodynamic fields capping subtropical marine stratocumulus. In this article, we present a series of multiyear atmosphere only simulations of E3SM version 1 where we progressively increase the vertical resolution in the lower troposphere to scales approaching those often used in large eddy simulation (LES). We report marginal impacts in regards to the simulation of boundary layer clouds when vertical resolution is moderately increased, yet find significant positive impacts when the vertical resolution approaches that typically used in LES (∼10 m). In these experiments, there is a marked change in the simulated turbulence and thermodynamics which leads to more abundant marine stratocumulus. However, these simulations are burdened with excessive computational cost. They are also subject to degradations in overall climate metrics due to time step sensitivities and because some processes and parameterizations are sensitive to changes in the vertical resolution.

54 ENVIRONMENTAL SCIENCES↗

On controlling robots with redundancy

An adaptive position control scheme for manipulators possessing either kinematic or actuator redundancy is presented. The controller is developed by considering the end-effector position control problem and redundancy resolution problem separately. The end-effector position control problem is solved by using an adaptive scheme to generate the Cartesian-space control input required to track the desired end-effector position trajectory; this control problem is nonredundant even for redundant robots. The Cartesian-space position controller is derived using a model reference adaptive control (MRAC) approach, and does not require knowledge of the complex robot dynamic model or parameter values for the robot or the payload. As a result, the scheme is applicable to both open-chain and closed-chain robots, and is computationally efficient for on-line implementations.

Colbaugh, R.↗

Development of thin-gap GEM- μ RWELL hybrid detectors

Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles impacting at a large angle with respect to the axis perpendicular to detector plane, the spatial resolution degrades significantly because of the long trail of ionization charges produced in clusters all along the track in the drift region of the detector. The long ionization charge trail results in registering hits from large number of strips in the readout plane which makes it challenging to precisely reconstruct the particle’s position using simple center of gravity algorithm. As a result, the larger the drift gap, the more severe the deterioration of spatial resolution for inclined tracks. For the same reason, the position resolution is also severely degraded in a large magnetic field, where the Lorentz E x B effect causes the ionization charges to follow a curved and longer path in the detector gas volume. In this paper, we report on the development of thin-gap MPGDs as a way to maintain excellent spatial resolution capabilities of MPGD detectors over a wide angular range of incoming particles. In a thin-gap MPGD, the thickness of the gas volume in the drift region is reduced from typically 3 mm to 1 mm or less. We present preliminary test beam results demonstrating the improvement in spatial resolution from 400 m with a standard 3 mm gap μ RWELL prototype to ~140 μ m with a double amplification GEM- μ RWELL thin-gap hybrid detector. Here, we also discuss the impact of a thin-gap drift volume on other aspects of the performance of MPGD technologies such as the efficiency and detector stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New detector for use in fast neutron radiography

We have developed and tested a new type detector for use in the fast neutron (FN) imaging radiography applications. FN radiography is generally used for nondestructive material testing, medical and biology applications, border patrol, transportation and cargo screening tasks. It is complementary to other types of radiography, providing additional information on light element content of the material samples. Distinct from other FN imagers presently known, our device implements a neutron-sensitive scintillator attached to a position-sensitive photomultiplier tube (PSPMT), and operates in an event-by-event readout mode, acquiring energy, timing, and pulse shape information for all detected radiation events. The information is used to help separate events of FN interactions in the scintillator from the background events caused by the electronics noise and by the other types of background radiation. Selection of pure fast neutron events in the final image allows us to achieve ultimate image contrast and resolution, as compared with other types of FN imaging devices operating most commonly in an integration mode, in which the detector?s dark noise and radiation background dilute the images. The detector performance for FN imaging application was tested using D-D neutron generator, designed and manufactured by Adelphi Technology, Inc. This essentially point-like neutron source operates in continuous mode producing up to 109 of 2.5 MeV neutrons per second. Samples made of metals plastic and other material were used to measure the detector resolution, efficiency and uniformity. Results of these tests are presented and discussed. Fig. 1 shows one of the test FN radiographic images obtained using the sample made of 11 styrene plastic strips. All strips are squares 4.8 x 4.8 mm2 with six different lengths 10 to 60 mm with 10 mm increment. [A] [B] [C] Fig. 1. [A]-layout of the test sample; [B]-raw FN shadow image of the sample; [C]-map of the plastic strips as they appear on the image, with measured FN absorption factor shown in percent. Both X and Y position resolution of the FN imaging detector are estimated to be less than 0.5 mm (sigma) based on the analysis of the edges of the strip shadows in the plot. Because this detector shows the fraction-of-a-millimeter resolution desirable for most of FN applications, and is built using radiation hard materials, we believe it could be a good alternative to other FN imaging systems based on CCD or solid state detectors. In addition, having a sub-nanosecond timing resolution, it is suitable for the time-of-flight energy-resolved FN imaging.

Popov, V.↗

SU-F-T-288: Impact of Trajectory Log Files for Clarkson-Based Independent Dose Verification of IMRT and VMAT

Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dose deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

To B or not to B: a question of resolution?

A simple rule of thumb based on resolution is not adequate to identify the best treatment of atomic displacements in macromolecular structural models. The choice to use isotropic B factors, anisotropic B factors, TLS models or some combination of the three should be validated through statistical analysis of the model refinement. In choosing and refining any crystallographic structural model, there is tension between the desire to extract the most detailed information possible and the necessity to describe no more than what is justified by the observed data. A more complex model is not necessarily a better model. Thus, it is important to validate the choice of parameters as well as validating their refined values. One recurring task is to choose the best model for describing the displacement of each atom about its mean position. At atomic resolution one has the option of devoting six model parameters (a ‘thermal ellipsoid’) to describe the displacement of each atom. At medium resolution one typically devotes at most one model parameter per atom to describe the same thing (a ‘B factor’). At very low resolution one cannot justify the use of even one parameter per atom. Furthermore, this aspect of the structure may be described better by an explicit model of bulk displacements, the most common of which is the translation/libration/screw (TLS) formalism, rather than by assigning some number of parameters to each atom individually. One can sidestep this choice between atomic displacement parameters and TLS descriptions by including both treatments in the same model, but this is not always statistically justifiable. The choice of which treatment is best for a particular structure refinement at a particular resolution can be guided by general considerations of the ratio of model parameters to the number of observations and by specific statistics such as the Hamilton R-factor ratio test.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure of hepatitis C virus IRES subdomain IIa

The hepatitis C (HCV) internal ribosome entry site (IRES) element plays a central role in cap-independent translation of the viral genomic RNA. The unique conformation of IRES domain II is critical for 80S ribosomal assembly and initiation of viral translation. Here, the crystal structure of subdomain IIa of the HCV IRES has been determined at 2.3 {angstrom} resolution, revealing the positions of divalent metal ions and complex inter-strand interactions that stabilize the L-shaped conformation of the RNA. The presence of divalent metal ions was necessary for crystal formation. Magnesium ions occupy specific sites that appear to be critical for the formation of the folded conformation. Subdomain IIa also was crystallized in the presence of strontium, which improved the diffraction quality of the crystals and the ability to identify interactions of the RNA with metal ions and tightly bound water molecules. The hinge region and noncanonical G-U base-pair motifs are stabilized by divalent metal ions and provide unique structural features that are potential interaction sites for small-molecule ligands. The information obtained from the crystal structure provides a basis for structure-guided design of HCV translation inhibitors targeting disruption of ribosomal assembly.

60 APPLIED LIFE SCIENCES↗

Performance characterization of an internsity-modulated fiber optic displacement sensor

A testbed simulating an intensity-modulated fiber optic displacement sensor is experimentally characterized, and the implications regarding sensor design are discussed. Of interest are the intensity distribution of the transmitted optical signal and the relationships between sensor architecture and performance. Particularly, an intensity-modulated sensor's sensitivity, linearity, displacement range, and resolution are functions of the relative positioning of its transmitting and receiving fibers. In this paper, sensor architectures with various combinations of these performance metrics are discussed. A sensor capable of micrometer resolution is reported, and it is concluded that this work could lead to an improved methodology for sensor design.

42 ENGINEERING↗