Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single photon sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Impact Testing of Heat Source Exemplars

This report details the heat source impact testing performed at the Shock Thermodynamics Applied Research Facility (STAR). The purpose of these tests were to measure the impact behavior of a heated Ta-10W tantalum/tungsten alloy heat source exemplar. Each exemplar resembled a cylinder with a rectangular through-hole orthogonal to the cylinder axis-of-symmetry. In each test, the exemplar was impacted by a hardened steel impactor accelerated using the STAR air gun. The exemplars were impacted perpendicular to the through-hole and at an an angle to the cylindrical axis-of-symmetry. The exemplar bar stock source, impact angle, and impact velocity were varied throughout the testing series. High-speed video was used to measure dynamic impact behavior while photon doppler velocimetry (PDV) and shorting pins were used to measure the impact velocity. Foam support structures were used to thermally isolate the exemplar and provide a support structure which was non-perturbative to the impact event. Soft-catch techniques were used to minimize secondary impacts and enable recovery for detailed post-shot analysis. Results indicate positive correlation between exemplar fracture and the variables of impact velocity and impact angle. Exemplar fracture occurred consistently along a single corner of the through-hole.

36 MATERIALS SCIENCE↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

Ultra-high dose rate FLASH irradiator at the radiological research accelerator facility

The Radiological Research Accelerator Facility has modified a decommissioned Varian Clinac to deliver ultra-high dose rates: operating in 9 MeV electron mode ( FLASH mode), samples can be irradiated at a Source-Surface Distance (SSD) of 20 cm at average dose rates of up to 600 Gy/s (3.3 Gy per 0.13 µs pulse, 180 pulses per second). In this mode multiple pulses are required for most irradiations. By modulating pulse repetition rate and irradiating at SSD = 171 cm, dose rates below 1 Gy/min can be achieved, allowing comparison of FLASH and conventional irradiations with the same beam. Operating in 6 MV photon mode, with the conversion target removed ( SuperFLASH mode), samples are irradiated at higher dose rates (0.2–150 Gy per 5 µs pulse, 360 pulses per second) and most irradiations can be performed with a single very high dose rate pulse. In both modes we have seen the expected inverse relation between dose rate and irradiated area, with the highest dose rates obtained for beams with a FWHM of about 2 cm and ± 10% uniformity over 1 cm diameter. As an example of operation of the ultra-high dose rate FLASH irradiator, we present dose rate dependence of dicentric chromosome yields.

43 PARTICLE ACCELERATORS↗

Unraveling sources of emission heterogeneity in Silicon Vacancy color centers with cryo-cathodoluminescence microscopy

Diamond color centers have proven to be versatile quantum emitters and exquisite sensors of stress, temperature, electric and magnetic fields, and biochemical processes. Among color centers, the silicon-vacancy (SiV - ) defect exhibits high brightness, minimal phonon coupling, narrow optical linewidths, and high degrees of photon indistinguishability. Yet the creation of reliable and scalable SiV - -based color centers has been hampered by heterogeneous emission, theorized to originate from surface imperfections, crystal lattice strain, defect symmetry, or other lattice impurities. Here, we advance high-resolution cryo-electron microscopy combined with cathodolumines cence spectroscopy and 4D scanning transmission electron microscopy (STEM) to elucidate the structural sources of heterogeneity in SiV - emission from nanodiamond with sub-nanometer-scale resolution. Our diamond nanoparticles are grown directly on TEM membranes from molecular-level seedings, representing the natural formation conditions of color centers in diamond. We show that individual subcrystallites within a single nanodiamond exhibit distinct zero-phonon line (ZPL) energies and differences in brightness that can vary by 0.1 meV in energy and over 70% in brightness. These changes are correlated with the atomic-scale lattice structure. We find that ZPL blue shifts result from tensile strain, while ZPL red shifts are due to compressive strain. We also find that distinct crystallites host distinct densities of SiV - emitters and that grain boundaries impact SiV - emission significantly. Finally, we interrogate nanodiamonds as small as 40 nm in diameter and show that these diamonds exhibit no spatial change to their ZPL energy. Our work provides a foundation for atomic-scale structure-emission correlation, e.g., of single atomic defects in a range of quantum and two-dimensional materials.

36 MATERIALS SCIENCE↗

Photon energy-resolved velocity map imaging from spectral domain ghost imaging

Abstract We present an approach that combines photon spectrum correlation analysis with the reconstruction of three-dimensional momentum distribution from velocity map images in an efficient, single-step procedure. We demonstrate its efficacy with the results from the photoionization of the 2 p -shell of argon using the Free-electron LASer in Hamburg free-electron laser (FEL). Distinct spectral features due to the spin-orbit splitting of Ar + ( 2 p − 1 ) are resolved, despite the large average bandwidth of the ionizing pulses from the FEL. This demonstrates a clear advantage over the conventional analysis method, and it will be broadly beneficial for velocity map imaging experiments with FEL sources. The retrieved linewidth of the binding energy spectrum approaches the resolution limitation prescribed by the spectrometers used to collect the data. Our approach presents a path to extend spectral-domain ghost imaging to the case where the photoproduct observable is high-dimensional.

47 OTHER INSTRUMENTATION↗

Prediction Accuracy of Error Rates for MPTB Space Experiment

This paper addresses the accuracy of radiation-induced upset-rate predictions in space using the results of ground-based measurements together with standard environmental and device models. The study is focused on two part types - 16 Mb NEC DRAM's (UPD4216) and 1 Kb SRAM's (AMD93L422) - both of which are currently in space on board the Microelectronics and Photonics Test Bed (MPTB). To date, ground-based measurements of proton-induced single event upset (SEM cross sections as a function of energy have been obtained and combined with models of the proton environment to predict proton-induced error rates in space. The role played by uncertainties in the environmental models will be determined by comparing the modeled radiation environment with the actual environment measured aboard MPTB. Heavy-ion induced upsets have also been obtained from MPTB and will be compared with the "predicted" error rate following ground testing that will be done in the near future. These results should help identify sources of uncertainty in predictions of SEU rates in space.

Buchner, S. P.↗

Perovskite CsPbBr 3 Single-Crystal Detector Operating at 10 10 Photons s -1 mm -2 for Ultra-High Flux X-ray Detection

Semiconductors for detecting hard radiation are confronted with considerable problems when operating at high photon fluxes. A perovskite CsPbBr 3 single-crystal detector capable of operating at X-ray fluxes of up to 10 10 photons s -1 mm -2 with beam area ≤ 0.25 mm 2 at 58.61 keV for current-mode X-ray detection is reported. The spectrometer-grade melt-grown CsPbBr 3 detectors show a gamma-ray energy resolution of ~7.5% at 122 keV for 57 Co and dark current as low as 4.3 nA (0.5 nA mm -2 ) at a reverse bias voltage of 200 V (118 V mm -1 ). The detector is tested at X-ray energies of 8.2, 10, and 58.61 keV at a synchrotron light source under a reverse bias voltage of up to 1000 V (588 V mm -1 ). Under a sufficiently high bias voltage and within several hundreds of seconds X-ray exposure, good photocurrent linearity (goodness of fit R 2 > 0.99) and reproducibility are obtained up to a flux of ≈10 10 photons s -1 mm -2 at beam area 0.25 mm 2 with Lower Limit of Detection of ≈10 5 photons s -1 mm -2 and Charge Collection Efficiency of ≈100% for 58.61 keV X-rays. Therefore, wide application of CsPbBr 3 detectors in high-flux X-ray detection is anticipated.

36 MATERIALS SCIENCE↗

Tunable x-ray free electron laser multi-pulses with nanosecond separation

X-ray Free Electron Lasers provide femtosecond x-ray pulses with narrow bandwidth and unprecedented peak brightness. Special modes of operation have been developed to deliver double pulses for x-ray pump, x-ray probe experiments. However, the longest delay between the two pulses achieved with existing single bucket methods is less than 1 picosecond, thus preventing the exploration of longer time-scale dynamics. We present a novel two-bucket scheme covering delays from 350 picoseconds to hundreds of nanoseconds in discrete steps of 350 picoseconds. Performance for each pulse can be similar to the one in a single pulse operation. The method has been experimentally tested with the Linac Coherent Light Source (LCLS-I) and the copper linac with LCLS-II hard x-ray undulators.

47 OTHER INSTRUMENTATION↗

A New Superconducting Undulator Cryostat for the APS Upgrade

The Advanced Photon Source (APS) is in the midst of a major facility upgrade including both a new electron storage ring (SR) and many new insertion devices ( IDs) providing x-ray photon beams to a new suite of experimental end stations. Included among the new IDs are four 4.8-meter superconducting undulator (SCU) cryostats, each containing two 1.8-meter planar undulator magnets operating at 4.2 K in either a phase shifted or canted configuration. We describe a new, compact cryocooler-based cryostat design which supports the magnets and associated subsystems and also fits the space constraints of the SR ID straight sections. The design is an evolution of earlier single-magnet 2-meter cryostats, retaining some subsystem commonality while incorporating lessons learned and several features unique to the challenge of supporting two independently operable undulator magnets in a single device.

Anliker, E.↗

The scattered solar X-ray background in low earth orbit

In order to interpret X-ray observations of the sun-lit earth obtained with the IPC, a detailed model is developed that treats the radiative transfer of solar X-rays in single scattering approximation and employs the relevant scattering processes (elastic Thomson scattering and inelastic fluorescent scattering). The X-ray-bright earth, one of the strongest soft X-ray sources seen by the IPC, can then be understood in terms of solar X-rays scattered in the upper atmosphere. Using the CIRA 1972 Reference Atmosphere, it is possible to account for the observed 'bright earth' X-ray light curves under a variety of different viewing geometries. It is argued that the observed changes in hardness ratio of the scattered radiation can be interpreted as an indication of a change in the ratio of Thomson and fluorescently scattered photons as a function of zenith angle. The relevance of bright earth X-ray observations is further discussed in the context of operating X-ray telescopes in low-earth orbit, as well as in a broader astrophysical context.

Fink, H. H.↗

Geoscience Laser Altimeter System (GLAS) on the ICESat Mission: Initial Science Measurement Performance

The Geoscience Laser Altimeter System is the space lidar on the NASA ICESat mission. Its design combines an altimeter with 5 cm precision with a laser pointing angle determination system and a dual wavelength cloud and aerosol lidar. GLAS measures the range to the Earth s surface with 1064 nm laser pulses. Each laser pulse produces a precision pointing measurement from the stellar reference system (SRS) and an echo pulse waveform, which permits range determination and waveform spreading analysis. The single shot ranging accuracy is < 10 cm for ice surfaces with slopes < 2 degrees. GLAS also measures atmospheric backscatter profiles at both 1064 and 532 nm. The 1064 nm measurements use an analog Si APD detector and measure the height and profile the backscatter signal from thicker clouds. The measurements at 532 nm use photon counting detectors, and will measure the vertical height distributions of optically thin clouds and aerosol layers Before launch, the measurement performance of GLAS was evaluated using a lidar test instrument called the Bench Check Equipment (BCE). The BCE was developed in parallel with GLAS and served as an inverse altimeter, inverse lidar and a stellar source simulator. It was used to simulate the range of expected optical inputs to the GLAS receiver by illuminating its telescope with simulated background light as well as laser echoes with known powers, energy levels, widths and delay times. The BCE also allowed monitoring of the transmitted laser energy, the angle measurements of the SRS, the co-alignment of the transmitted laser beam to the receiver line of sight, and performance of the flight science algorithms. Performance was evaluated during the GLAS development, before and after environmental tests, and after delivery to the spacecraft. The ICESat observatory was launched into a 94 degree inclination, 590 km altitude circular polar orbit on January 12,2003. Beginning in early February, GLAS was powered on tested in stages. Its 1064 nm optical receiver was evaluated in a several tests using both solar background light and an internal test source. Laser 1 was activated on February 20,2003. GLAS operated with Laser 1 for 38 continuous days on orbit using its 1064 nm receiver channel, producing over 130 million individual laser measurements of the Earth s surface and atmosphere. These nadir-pointed measurements fell along the ICESat s ground track, and spanned more than 4 cycles of the initial 8-day ICESat repeat orbit. The initial GLAS measurement set shows strong echo pulses from ranging to the surface topography, oceans, ice sheets and cloud tops, as well as profiles of clouds and aerosols. The GLAS measurements have unprecedented vertical and angular resolution, and show nearly continuous height profiles of ice, land and ocean surfaces or cloud tops, as well profiles of backscatter from thin clouds and aerosol layers. Examples of these GLAS measurements and an initial assessment of its science measurement performance will be presented.

Abshire, James B.↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

Continued RXTE Observations of Three Blazars

This project continued (during Cycle 3 of the RXTE mission) weekly observations of the quasars PKS 1510-089 and 3C 454.3 and the BL Lac object OJ 287. The data were analyzed by the PI and his graduate student. In the middle of Cycle 3, the PI changed the mode of observation of 3C 454.3, based on a report from another astronomer that observations with the Rosat satellite had found a strong confusing X-ray source about 45 arcmin away. The RXTE observations, in which the flux was measured while pointing directly at 3C 454.3 and then 15' from 3C 454.3, in the direction away from the confusing source. The flux decreased considerably, and so it appears that nearly all the X-ray flux measured by RXTE comes from the confusing source rather than the quasar. OJ 287 was detected only at one epoch of the Cycle 3 observations. This corresponded to a particularly quiet period for this source, when its flux at other wavebands was also low. From the single epoch of detection, no conclusions can be drawn concerning the general nature of the X-ray emission from this object. In contrast to the other two sources, the results of the observations of PKS 1510-089, when combined with data from cycles 3 and 4, are very interesting. The RXTE (2.4-20 keV) abd 14.5 GHz University of Michigan Radio Astronomy Observatory (UMRAO) light curves through the end of RXTE Cycle 4 are shown for PKS 1510-089. Visual inspection reveals an obvious correlation between the X-ray and 14.5 GHz light curves. While this is as expected in the SSC model in a source with simultaneous mm-wave (the photons thought to be scattered to X-ray energies) and cm-wave variations, the X-ray spectrum is flat ("energy" spectral index alpha = 0.2-0.5, where F (sub v) proportional to v (sup - alpha)) compared with the mm-wave synchrotron spectrum (alpha approximately equal to 0.8). The PI is currently engaged in theoretical work to determine whether this is possible for an SSC model.

Marscher, Alan P.↗

Far Infrared Continuum Emission from the Galactic Center

High angular resolution observations of the Galactic center from the Kuiper Airborne Observatory are discussed. The results of multi-wavelength mapping reveal that the 30 micron distribution shows a single peak which lies between two emission lobes seen at the longer wavelengths. The 30 micron emission is known from ground-based measurements to peak at the galactic center. The far-infrared color temperature and luminosity also peak at the position of the galactic center, and the observations show a strong temperature gradient away from the galactic center in all directions. Consideration of these data leads to the conclusion that the dust density decreases inward over the central 3 pc of the Galaxy, and that the central parsec of the Galaxy is remarkably devoid of dust, so that optical and ultraviolet photons may traverse it freely. The inferred total luminosity of the sources that heat the dust radiating the far-infrared emission from the central few pc of the Galaxy is 1 to 3 x to the 7th power L(Sun). It is probable that these same sources are responsible for ionizing the plasma at the galactic center.

Werner, M. W.↗

Vacuum system design, construction, and operation for the Cornell High Energy Synchrotron Source upgrade

During the summer and fall 2018, the Cornell High Energy Synchrotron Source (CHESS), underwent an upgrade that recast the facility as primarily a low emittance X-ray source. The upgrade replaced one sixth of the Cornell Electron Storage Ring (CESR) with six double-bend achromats, featuring four novel CHESS Compact Undulator (CCU) insertion devices, and switched CESR to single particle beam operation. At the time of this writing, the upgraded storage ring has achieved the CHESS-U design goal of operating with 200 mA of positron current at 6.0 GeV beam energy. Additionally, seven out of eleven CHESS-U beamlines are currently in X-ray user operation. The construction and the commissioning of the new section of the CESR accelerator required novel solutions to design, fabrication, and vacuum system operations. Significant design considerations and efforts were made to minimize X-ray ‘dark-time’, returning to operation less than 1 year. This paper describes the important milestones of the process, the solutions implemented, and the present status of CHESS-U.

43 PARTICLE ACCELERATORS↗

Creating heralded hyper-entangled photons using Rydberg atoms

Entangled photon pairs are a fundamental component for testing the foundations of quantum mechanics, and for modern quantum technologies such as teleportation and secured communication. Current state-of-the-art sources are based on nonlinear processes that are limited in their efficiency and wavelength tunability. This motivates the exploration of physical mechanisms for entangled photon generation, with a special interest in mechanisms that can be heralded, preferably at telecommunications wavelengths. Here we present a mechanism for the generation of heralded entangled photons from Rydberg atom cavity quantum electrodynamics (cavity QED). We propose a scheme to demonstrate the mechanism and quantify its expected performance. The heralding of the process enables non-destructive detection of the photon pairs. The entangled photons are produced by exciting a rubidium atom to a Rydberg state, from where the atom decays via two-photon emission (TPE). A Rydberg blockade helps to excite a single Rydberg excitation while the input light field is more efficiently collectively absorbed by all the atoms. The TPE rate is significantly enhanced by a designed photonic cavity, whose many resonances also translate into high-dimensional entanglement. The resulting high-dimensionally entangled photons are entangled in more than one degree of freedom: in all of their spectral components, in addition to the polarization—forming a hyper-entangled state, which is particularly interesting in high information capacity quantum communication. We characterize the photon comb states by analyzing the Hong-Ou-Mandel interference and propose proof-of-concept experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗

Statistical modelling and Bayesian inversion for a Compton imaging system: application to radioactive source localization

Abstract This paper presents a statistical forward model for a Compton imaging system, called Compton imager. This system, under development at the University of Illinois Urbana Champaign, is a variant of Compton cameras with a single type of sensors which can simultaneously act as scatterers and absorbers. This imager is convenient for imaging situations requiring a wide field of view. The proposed statistical forward model is then used to solve the inverse problem of estimating the location and energy of point-like sources from observed data. This inverse problem is formulated and solved in a Bayesian framework by using a Metropolis within Gibbs algorithm for the estimation of the location, and an expectation-maximization algorithm for the estimation of the energy. This approach leads to more accurate estimation when compared with the deterministic standard back-projection approach, with the additional benefit of uncertainty quantification in the low photon imaging setting.

Tarpau, Cécilia (ORCID:0000000286539490)↗

HEASARC Software Archive

(1) Chandra Archive: SAO has maintained the interfaces through which HEASARC gains access to the Chandra Data Archive. At HEASARC's request, we have implemented an anonymous ftp copy of a major part of the public archive and we keep that archive up-to- date. SAO has participated in the ADEC interoperability working group, establishing guidelines or interoperability standards and prototyping such interfaces. We have provided an NVO-based prototype interface, intending to serve the HEASARC-led NVO demo project. HEASARC's Astrobrowse interface was maintained and updated. In addition, we have participated in design discussions surrounding HEASARC's Caldb project. We have attended the HEASARC Users Group meeting and presented CDA status and developments. (2) Chandra CALDB: SA0 has maintained and expanded the Chandra CALDB by including four new data file types, defining the corresponding CALDB keyword/identification structures. We have provided CALDB upgrades for the public (CIAO) and for Standard Data Processing. Approximately 40 new files have been added to the CALDB in these version releases. There have been in the past year ten of these CALDB upgrades, each with unique index configurations. In addition, with the inputs from software, archive, and calibration scientists, as well as CIAO/SDP software developers, we have defined a generalized expansion of the existing CALDB interface and indexing structure. The purpose of this is to make the CALDB more generally applicable and useful in new and future missions that will be supported archivally by HEASARC. The generalized interface will identify additional configurational keywords and permit more extensive calibration parameter and boundary condition specifications for unique file selection. HEASARC scientists and developers from SAO and GSFC have become involved in this work, which is expected to produce a new interface for general use within the current year. (3) DS9: One of the decisions that came from last year's HEADCC meeting was to make the ds9 image display program the primary vehicle for displaying line graphics (as well as images). The first step required to make this possible was to enhance the line graphics capabilities of ds9. SAO therefore spent considerable effort upgrading ds9 to use Tcl 8.4 so that the BLT line graphics package could be built and imported into ds9 from source code, rather than from a pre-built (and generally outdated) shared library. This task, which is nearly complete, allows us to extend BLT as needed for the HEAD community. Following HEADCC discussion concerning archiving and the display of archived data, we extended ds9 to support full access to many astronomical Web-based archives sites, including HEASARC, MAST, CHANDRA, SKYVIEW, ADS, NED, SIMBAD, IRAS, NVRO, SAO TDC, and FIRST. Using ds9's new internal Web access capabilities, these archives can be accessed via their Web page. FITS images, plots, spectra, and journal abstracts can be referenced, down-loaded, and displayed directly and easily in ds9. For more information, see: http://hea-www.harvard.edu/saord/ds9. Also after the HEADCC discussion concerning region filtering, we extended the Funtools sample implementation of region filtering as described in: http://hea-www.harvard.edu/saord/funtools/regions.html. In particular, we added several new composite regions for event and image filtering, including elliptical and box annuli. We also extended the panda (Pie AND Annulus) region support to include box pandas and elliptical pandas. These new composite regions are especially useful in programs that need to count photons in each separate region using only a single pass through the data. Support for these new regions was added to ds9. In the same vein, we developed new region support for filtering images using simple FITS image masks, i.e. 8-bit or 16-bit FITS images where the value of a pixel is the region id number for that pixel. Other important enhancements to DS9 this year, include supporor multiple world coordinate systems, three dimensional event file binning, image smoothing, region groups and tags, the ability to save images in a number of image formats (such as JPEG, TIFF, PNG, FITS), improvements in support for integrating external analysis tools, and support for the virtual observatory. In particular, a full-featured web browser has been implemented within D S 9 . This provides support for full access to HEASARC archive sites such as SKYVIEW and W3BROWSE, in addition to other astronomical archives sites such as MAST, CHANDRA, ADS, NED, SIMBAD, IRAS, NVRO, SA0 TDC, and FIRST. From within DS9, the archives can be searched, and FITS images, plots, spectra, and journal abstracts can be referenced, downloaded and displayed The web browser provides the basis for the built-in help facility. All DS9 documentation, including the reference manual, FAQ, Know Features, and contact information is now available to the user without the need for external display applications. New versions of DS9 maybe downloaded and installed using this facility. Two important features used in the analysis of high energy astronomical data have been implemented in the past year. The first is support for binning photon event data in three dimensions. By binning the third dimension in time or energy, users are easily able to detect variable x-ray sources and identify other physical properties of their data. Second, a number of fast smoothing algorithms have been implemented in DS9, which allow users to smooth their data in real time. Algorithms for boxcar, tophat, and gaussian smoothing are supported.

White, Nicholas↗