Search NASA⌕ Search

SEARCH · Search NASA

Results for “Superconducting Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Statistics and sensitivity of axion wind detection with the homogeneous precession domain of superfluid helium-3

The homogeneous precession domain (HPD) of superfluid He 3 has recently been identified as a detection medium which might provide sensitivity to the axion-nucleon coupling g a N N competitive with, or surpassing, existing experimental proposals. In this work, we make a detailed study of the statistical and dynamical properties of the HPD system in order to make realistic projections for a full-fledged experimental program. We include the effects of clock error and measurement error in a concrete readout scheme using superconducting qubits and quantum metrology. This work also provides a more general framework to describe the statistics associated with the axion gradient coupling through the treatment of a transient resonance with a nonstationary background in a time-series analysis. Incorporating an optimal data-taking and analysis strategy, we project a sensitivity approaching g a N N ∼ 10 − 12 GeV − 1 across a decade in axion mass. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Graphene-based analog of single-slit electron diffraction

In this study, we report on the experimental demonstration of single-slit diffraction exhibited by electrons propagating in encapsulated graphene with an effective de Broglie wavelength corresponding to their attributes as massless Dirac fermions. Nanometer-scale device designs were implemented to fabricate a single-slit followed by five detector paths. Predictive calculations were also utilized to readily understand the observations reported. These calculations required the modeling of wave propagation in ideal case scenarios of the reported device designs to more accurately describe the observed single-slit phenomenon. This experiment was performed at room temperature and 190 K, where data from the latter highlighted the exaggerated asymmetry between electrons and holes, recently ascribed to slightly different Fermi velocities near the K point. This observation and device concept may be used for building diffraction switches with versatile applicability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hyperspectral X-ray Imaging: Progress Towards Chemical Analysis in the SEM

The Hyperspectral X-ray Imaging (HXI) project will enable non-destructive chemical-state determination of nano-scale samples in the electron microscope for nuclear safeguards applications. To efficiently measure chemical state through electron-excited X-ray emission requires a combination of wide spectral bandwidth, high resolution, and high count rate capability. We are building a next-generation X-ray detector based on an array of transition edge sensors (TESs) to make these measurements possible and routine in the scanning electron microscope (SEM). Leveraging the large pixel densities afforded by microwave multiplexing readout and continuous, uninterrupted operation of a cryogen-free dilution refrigerator, this instrument will have efficiency to allow chemical species identification of nano-scale samples in hours instead of days to weeks. We describe prototype pixel designs for this HXI instrument, comprising three pixel types that will make up the hybrid TES array. Engineering design of the integrated HXI cryostat and SEM system is in progress, with full detector commissioning expected in Spring 2021 followed closely by full-scale integration with the SEM. Furthermore, we also report on the commissioning of a complementary TES-based X-ray emission spectroscopy platform for bulk samples to build a spectral library for HXI sample identification.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Thermal Tomography Imaging System for In-Service Nondestructive Evaluation of Additively Manufactured Components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Thermal tomography (TT) provides a capability for non-destructive evaluation of sub-surface defects in arbitrary size structures. We investigate TT of AM stainless steel 316L specimen with imprinted internal porosity defects using relatively low-cost, small form factor infrared (IR) camera based on uncooled micro bolometer detector. Sparse coding related K-means singular value decomposition (SVD) machine learning, image processing algorithms are developed to improve quality of TT images through removal of Additive white Gaussian noise without blurring the images. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact TT can also be used for in-service nondestructive evaluation (NDE). With capability to perform in-service NDE of the AM component lifecycle, TT data can be used for development of a component digital twin. MIT research reactor (MITR) has been identified as a representative environment to perform investigation of feasibility of in-service NDE during shutdown. Preliminary study of radiation level in the MITR viewport, with geometric parameters potentially compatible with compact TT system, has been conducted.

36 MATERIALS SCIENCE↗

Charge Transport and Space-Charge Formation in Cd 1 - x Zn x Te 1 - y Se y Radiation Detectors

The electron- and hole-transport properties in cadmium zinc telluride selenide (CZTS) crystals are studied using a laser-induced transient-current technique with pulsed and dc bias. The internal electric field profile and velocity of surface recombination are determined by Monte Carlo simulations of electron and hole transient currents combined with a numerical solution of the drift-diffusion equation coupled with Poisson’s equation. Electron and hole drift mobilities of μe = 830 cm 2 /Vs and μh = 40 cm 2 /Vs, respectively, are determined. We also develop a simple technique for evaluating surface recombination directly from measured current waveforms without the need for numerical simulation. The good quality of the prepared detector at pulsed bias, with electron- and hole-mobility-lifetime products of (μτ)e = 1.9 × 10 -3 cm 2 /V and (μτ)h = 1.4 × 10 -4 cm 2 /V, respectively, are observed. The formation of a positive space charge, originating from hole injection combined with a recombination level, is found. We observe a significant position dependence of the lifetime of electrons and holes in dc bias due to hole injection. The experiment is successfully fitted by a simple model dominated by a single deep recombination level with an energy of E t =E C -0.73eV; concentration of 7.3 × 10 11 cm -3 ; and electron- and hole-capture cross sections of 3.5 × 10 -14 cm 2 and 6.5 × 10 -14 cm 2 , respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Control Design for Inhomogeneous-Broadening Compensation in Single-Photon Transducers

We report a transducer of single photons between microwave and optical frequencies can be used to realize quantum communication over optical fiber links between distant superconducting quantum computers. A promising scalable approach to constructing such a transducer is to use ensembles of quantum emitters interacting simultaneously with electromagnetic fields at optical and microwave frequencies. However, inhomogeneous broadening in the transition frequencies of the emitters can be detrimental to this collective action. In this paper, we utilize a gradient-based optimization strategy to design the temporal shape of the laser field driving the transduction system to mitigate the effects of inhomogeneous broadening. We study the improvement of transduction efficiencies as a function of inhomogeneous broadening in different single-emitter cooperativity regimes and correlate it with a restoration of super-radiance effects in the emitter ensembles. Furthermore, to assess the optimality of our pulse designs, we provide certifiable bounds on the design problem and compare them to the achieved performance.

74 ATOMIC AND MOLECULAR PHYSICS↗

Probing nanoparticle substrate interactions with synchrotron infrared nanospectroscopy: Coupling gold nanorod Fabry-Pérot resonances with SiO 2 and $h$-BN phonons

Spectroscopic interrogation of materials in the midinfrared with nanometer spatial resolution is inherently difficult due to the long wavelengths involved, reduced detector efficiencies, and limited availability of spectrally bright, coherent light sources. Technological advances are driving techniques that overcome these challenges, enabling material characterization in this relatively unexplored spectral regime. Synchrotron infrared nanospectroscopy (SINS) is an imaging technique that provides local sample information of nanoscale target specimens in an experimental energy window between 330 and 5000 cm -1 . Here, using SINS, we analyzed a series of individual gold nanorods patterned on a SiO 2 substrate and on a flake of hexagonal boron nitride. The SINS spectra reveal interactions between the nanorod photonic Fabry-Pérot resonances and the surface phonon polaritons of each substrate, which are characterized as avoided crossings. A coupled oscillator model of the hybrid system provides a deeper understanding of the coupling and provides a theoretical framework for future exploration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wide Dynamic Range, 10 kHz Framing Detector for 4D-STEM

Hybrid pixel array detectors (PADs) have expanded the fidelity, frame rate and dynamic range for diffractive imaging in electron microscopes. With their high detective quantum efficiencies (DQE), the noise performance limited is by counting statistics. Consequently, improving the precision and quality of high-speed images requires increasing the linear dynamic range and the maximum usable beam current. Here we describe a new prototype hybrid PAD, our next-generation electron microscope pixel array detector (NG-EMPAD) that expands both the framing speed and dynamic range of our earlier EMPAD design. Like the EMPAD, electrons are detected directly in a 500 μm thick silicon sensor bonded pixel-by-pixel to a custom signal processing integrated circuit (IC). Each pixel in the IC integrates charge carriers produced by the high-energy incident electrons. Here, in-pixel circuitry uses a combination of techniques to extend the dynamic range, including adaptive gain switching and the quantitative excess charge dumping similar to the EMPAD. In-pixel buffering of signals during readout allows acquiring a new image while reading out the previously collected image, yielding an image collection duty cycle of nearly 100%.

36 MATERIALS SCIENCE↗

On single-crystal total scattering data reduction and correction protocols for analysis in direct space

Data reduction and correction steps and processed data reproducibility in the emerging single-crystal total-scattering-based technique of three-dimensional differential atomic pair distribution function (3D-ΔPDF) analysis are explored. All steps from sample measurement to data processing are outlined using a crystal of CuIr 2 S 4 as an example, studied in a setup equipped with a high-energy X-ray beam and a flat-panel area detector. Computational overhead as pertains to data sampling and the associated data-processing steps is also discussed. Various aspects of the final 3D-ΔPDF reproducibility are explicitly tested by varying the data-processing order and included steps, and by carrying out a crystal-to-crystal data comparison. Situations in which the 3D-ΔPDF is robust are identified, and caution against a few particular cases which can lead to inconsistent 3D-ΔPDFs is noted. Although not all the approaches applied herein will be valid across all systems, and a more in-depth analysis of some of the effects of the data-processing steps may still needed, the methods collected herein represent the start of a more systematic discussion about data processing and corrections in this field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scheme for stabilising the phase and arrival time of ultrashort laser pulses in a coherent beam combining fibre system

An algorithm has been demonstrated for simultaneously measuring the phase and arrival time of optical pulses relative to pulses in a reference channel using one detector array. Based on this algorithm, a simple optoelectronic pulse phase and arrival time stabilisation scheme has been designed for operation in a coherent beam combining fibre system for ultrashort pulses (including chirped ones). We have studied the performance of the stabilisation scheme. In particular, we have reached a phase measurement rate of 25 000 cps, demonstrated an ∼ 2 kHz limiting phase stabilisation frequency in a feedback loop, and obtained an arrival time measurement accuracy of ∼ 5 % of the transform-limited pulse duration at a measurement rate of 5 cps. In experiments concerned with coherent beam combining for two channels of a pulsed fibre system at a wavelength of 1030 nm, we have demonstrated phase stabilisation with an accuracy better than λ/100 and delay setting accuracy of 10 fs at a transform-limited pulse duration of ∼ 200 fs and obtained 94 % beam combining efficiency. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation and optimization of the PTOLEMY transverse drift electromagnetic filter

The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium β-decay endpoint. Here, we detail the implementation and optimization methods for successful operation of the filter for electrons with a known pitch angle. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to < 10 eV (< 1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratory (LNGS) in Italy.

47 OTHER INSTRUMENTATION↗

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

FOS: Physical sciences↗

Mapping valence electron distributions with multipole density formalism using 4D-STEM

Recent advancement in aberration correction and detector technology opened a door to various applications using 4D-STEM, which yields a diffraction pattern for each scanning position within a crystal unit-cell in scanning transmission electron microscopy (STEM) and generates incredible amounts of data in momentum space. Currently 4D-STEM analysis relies on the center-of-mass of the diffraction patterns in electric field and charge density mapping. It only derives the total projected charge density and is limited to phase objects, e.g. extremely thin samples. Here, we propose a new analytical method to accurately map aspherical valence electron distributions with atom-centered multipolar functions formalism using the whole 4D-STEM dataset. We demonstrate that, with the full dynamical calculations for various sample thicknesses, the method is sensitive not only to the miniscule charge transfer, but also to the atomic site symmetry and aspherical electron orbitals. The process of the refinement is much more robust and reliable than quantitative convergent beam electron diffraction.

4D-STEM↗

Spin Waves in Dirac Semimetal Ca 0.6⁢ Sr 0.4⁢ MnSb 2 Investigated with Neutrons by the Diffraction Method

The tunability of Dirac semimetals with antiferromagnetic Mn layers is of great interest. The observed sign change of interlayer magnetic coupling between CaMnBi 2 and SrMnBi 2 suggests ionic substitution as a potential tuning mechanism. If so, novel behavior near the compensation point could be expected. Here, to explore this, we study a mixed-cation analog, Ca 0.6⁢ Sr 0.4⁢ MnSb 2 , where Bi is replaced by Sb. Conventional inelastic neutron scattering is impractical due to the small crystal size (m ≈ 0.28 g) available for compositional studies; however, we find that using a neutron diffractometer with a wide-angle area detector we can obtain a good quality spin-wave signal, which is shaped by energy-momentum conservation and retains spectroscopic information even without direct energy analysis. Spin-wave modeling reveals an interlayer coupling quantitatively similar to SrMnSb 2 , indicating it is not directly tuned by ionic size and that the sign change in Bi-based compounds likely arises from the observed change in lattice symmetry. Beyond this key insight, our results present an efficient method for parametric and compositional studies of spin dynamics in small crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of K*(892) ± production in inelastic pp collisions at the LHC

The first results on K*(892) ± resonance production in inelastic pp collisions at LHC energies of √s = 5.02, 8, and 13 TeV are presented. The K*(892) ± has been reconstructed via its hadronic decay channel K*(892)→±K$^0_S$ +π ± with the ALICE detector. Measurements of transverse momentum distributions, p T -integrated yields, and mean transverse momenta for charged K*(892) are found to be consistent with previous ALICE measurements for neutral K*(892) within uncertainties. For p T >1 GeV/c the K*(892) ± transverse momentum spectra become harder with increasing centre-of-mass energy from 5.02 to 13 TeV, similar to what previously observed for charged kaons and pions. For p T < GeV/c the K*(892) ± yield does not evolve significantly and the abundance of K*(892) ± relative to K is rather independent of the collision energy. The transverse momentum spectra, measured for K*(892) ± at midrapidity in the interval 0 < p T <15 GeV/c, are not well described by predictions of different versions of PYTHIA 6, PYTHIA 8 and EPOS-LHC event generators. These generators reproduce the measured p T -integrated K *± /K ratios and describe well the momentum dependence for p T <2 GeV/c.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Signal processing and spectral modeling for the BeEST experiment

The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment searches for evidence of heavy neutrino mass eigenstates in the nuclear electron capture decay of 7 Be by precisely measuring the recoil energy of the 7 Li daughter. In Phase III, the BeEST experiment has been scaled from a singl superconducting tunnel junction (STJ) sensor to a 36-pixel array to increase sensitivity and mitigate gamma-induced backgrounds. Phase III also uses a new continuous data acquisition system that greatly increases the flexibility for signal processing and data cleaning. Here, we have developed procedures for signal processing and spectral fitting that are sufficiently robust to be automated for large datasets. Furthermore, this article presents the optimized procedures before unblinding the majority of the Phase III dataset to search for physics beyond the standard model.

6 ≤ A ≤ 19↗

The structure of low-lying 1 - states in 90,94 Zr from (α,α'γ) and (p,p'γ) reactions

The low-lying dipole strength in the 90,94 Zr nuclei was investigated via (ρ,ρ'γ) at 80 MeV and (α, α', γ) at 130 MeV. The experiments, made at RCNP, used the magnetic spectrometer Grand Raiden for the scattered particles and the array CAGRA with HPGe detectors for the γ-decay. For 94 Zr these are the first data for both reactions and for 90 Zr these are the first data with (ρ,ρ'γ) and the first ones at high resolution for (α, α', γ). The comparison of the present results for the two nuclei with existing (γ, γ') data shows that both nuclear probes produce an excitation pattern different than that of the electromagnetic probes. DWBA calculations were made using form factors deduced from transition densities, based on RPA calculations, characterized by a strong neutron component at the nuclear surface. A combined analysis of the two reactions was performed for the first time to investigate the isoscalar character of the 1 - states in 90,94 Zr. The (ρ,ρ'γ) cross section was calculated using values for the isoscalar electric dipole energy-weighted sum rule (E1 ISEWSR) obtained from the (α, α', γ) data. The isoscalar strength for 90 Zr was found to exhaust 20 ± 2.5% of the EWSR in the energy range up to 12 MeV. In case of 94 Zr, a strength of 9 ± 1.1% of the EWSR was found in the range up to 8.5 MeV. Although an overall general description was obtained in the studied energy intervals, not all proton cross sections were well reproduced using the isoscalar strength from (α, α', γ). This might suggest mixing of isoscalar and isovector components and that this mixing and the degree of collectivity are not the same for all the 1 - states below the particle binding energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗