Peeking through the picket fence - What astrophysical surprises may be present in the 100-200 A region?

In anticipation of more sensitive EUV and FUV spectroscopic instruments, spectra are simulated including interstellar absorption of solarlike, RS CVn, and flare stars as folded through the instrument parameters of the EUVE, Lyman/FUSE Phase A, and a desirable next-generation spectrometer. Even the relatively insensitive EUVE spectrometer is able to detect sufficient spectral lines from many active binary and dMe stars to determine their coronal-emission-measure distributions. The Lyman/FUSE or next-generation spectrometers are needed to study solar-type stars or flaring stars with high time resolution. The high throughput and effective area of a nex-generation spectrometer is needed for Doppler imaging studies, stellar wind and downflow measurements, and high time and spectral resolution of stellar flares.

Linsky, Jeffrey L.↗

Fast and Accurate Pixel Calibration of Tof Neutron Diffractometers with Machine Learning

At a spallation neutron source, neutron pulses of varying energies are generated, and the detection of neutrons by instrument detectors is recorded as time-of-flight from the emission of the neutron pulse to its arrival at specific detector pixels with high time resolution. The flight path of neutrons from the moderator to the sample and then to the detector must be precisely calibrated at the detector-pixel level using standard powders, so the neutron events from all pixels can be time-focused to produce high-resolution diffraction patterns. Modern time-of-flight neutron diffractometers at spallation neutron sources are equipped with two-dimensional detectors with millimeter-scale pixelations. The number of pixels in a diffraction instrument can reach millions, which makes a single-pixel-level calibration process time-consuming or even impossible with conventional refinement or fitting approaches. Here we present a machine-learning-aided calibration process using a train-and-predict approach, in which machine learning models are trained on the relationship between an individual pixel time-of-flight diffraction pattern and its diffraction constant. These models use a portion of the available pixels for training, and a good model then predicts the diffraction constants precisely and rapidly for large sets of pixel diffraction patterns.

detector pixel calibration↗

Shock-induced kinetics and cellular structures of liquid nitromethane detonation

Using a combination of high-speed diagnostics, optical pyrometry, velocimetry and video photography, we examine the spatiotemporal reaction kinetics of a prototypical high-energy explosive, liquid nitromethane (NM), as we drive this high explosive into detonation. The detonations were initiated by powerful shock waves whose durations (4 ns) were shorter than the characteristic time associated with the reaction (7 ns). Simple optical spectroscopy alone cannot characterize the kinetics with high time resolution because the reactants and products are flowing at a high velocity of ~6 km/s (6 µm/ns). Additionally, every detection volume behind the shock front contains material initiated over a range of times. High spatial resolution can be obtained by probing interfaces where the shock enters or breaks out of the NM. In addition, we obtain cellular patterns imprinted on the luminous shock front by the two-stage explosion in NM. These spatiotemporal patterns arise naturally as a result of the asymmetry produced by the moving shock front. In this way the shock front serves as a thin moving intrinsic optical gauge that reports and characterizes the two-stage NM explosion behind the front.

42 ENGINEERING↗

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently taking data in the Short Baseline Neutrino (SBN) program at Fermilab (U.S.A.) to search for a possible LSND-like sterile neutrino signal at Δm 2 ≈ 1 eV 2 with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced by the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths installation, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of genuine neutrino interactions. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers. To achieve a time resolution better than 1 ns, we perform three consecutive timing corrections deployed at different stages of the optical data flow. Results demonstrate the capability of the ICARUS-T600 light detection system to allow a precise reconstruction of the temporal evolution of each event occurring in the detector and the association of neutrino events with the bunched structure of BNB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Space and time variations of the solar Na D line profiles.

Preliminary results are presented of observations of the solar Na D lines obtained with high space and time resolution. The line profiles vary strongly with space and time implying that time averaging over a long period and large area will not produce the 'true' profile. The centre-limb increase in apparent Doppler width in the D lines is intrinsic. It is not due to space or time averaging. The amplitude of the 300-sec oscillation may range up to 1.5 km/sec in the region of formation of the D lines. The variation of the D line profile caused by the 300-sec oscillation may be described as follows: (1) the core is raised and lowered without change of shape, and (2) the wings broaden as the central intensity rises and narrow as it falls. Doppler width values derived from pairs of D line profiles are strongly correlated with the motion of the element observed. Indications of running waves have been found in the time variation of the core line bisectors.

Slaughter, C. D.↗

The M.I.T. Blowdown compressor facility

A blowdown compressor test facility has been developed which allows time-resolved aerodynamic testing of full-scale transonic compressor rotors at low cost. The rotor is brought to speed in vacuum, a diaphragm is opened, and the test gas is allowed to flow for a time of the order of 0.1 sec, during which the rotor is driven by its own inertia. Both 'steady-state' performance evaluation and detailed time resolution of the flow on the blade-passing time scale have been demonstrated for a two-ft-diam transonic rotor with a tangential Mach number of 1.2 and a nominal pressure ratio of 1.6. The steady-state performance as determined in the experiments includes an efficiency of 0.92 and a pressure ratio of 1.55 at design speed. The time-resolved measurements include the combination tone structure in the upstream flow field, resolved both axially and radially, and the wake structure downstream of the rotor, also resolved both radially and axially.

Kerrebrock, J. L.↗

JPL self pulsed laser surface measurement system development

The use of a self pulsed laser system for accurately describing the surface shape of large space deployed antenna structures was evaluated. Tests with a breadboard system verified functional operation with short time resolution on the order of .2 mm, nonambiguous ranging, and a maximum range capability on the order of 150 m. The projected capability of the system is resolution of less than .1 mm over a reasonable time period and a range extension to over 300 m.

Berdahl, M.↗

Fine time structure in the 1979 March 5 gamma ray burst

Data on the impulsive phase of the 1979 March 5 gamma ray burst, taken by three identical detectors aboard the Prognoz 7, Venera 11, and Venera 12 spacecraft with 2 ms time resolution, are presented. The first 200 ms of the time history may be described by an exponential decay with time constant of approximately 120 ms up to approximately 100 ms, and time constant of approximately 30 ms thereafter; at low energies, a pulsating component with a period of approximately 23 ms appears. The data could be consistent with torsional vibrations of a neutron star, the rotation of a rapidly spinning neutron star, or oscillations caused by interactions between hot plasma and a magnetic field.

Barat, C.↗

The observation of possible reconnection events in the boundary changes of solar coronal holes

Coronal holes are large scale regions of magnetically open fields which are easily observed in solar soft X-ray images. The boundaries of coronal holes are separatrices between large-scale regions of open and closed magnetic fields where one might expect to observe evidence of solar magnetic reconnection. Previous studies by Nolte and colleagues using Skylab X-ray images established that large-scale (more than 90,000 km) changes in coronal hole boundaries were due to coronal processes, i.e., magnetic reconnection, rather than to photospheric motions. Those studies were limited to time scales of about one day, and no conclusion could be drawn about the size and time scales of the reconnection process at hole boundaries. Sequences of approximate Skylab X-ray images with a time resolution of about 90 min are here used during times of the central meridian passages of the coronal hole labelled 'Coronal Hole 1' to search for hole-boundary changes which can yield the spatial and temporal scales of coronal magnetic reconnection. It is found that 29 of 32 observed boundary changes could be associated with bright points. The appearance of the bright point may be the signature of reconnection between small-scale and large-scale magnetic fields. The observed boundary changes contributed to the quasi-rigid rotation of Coronal Hole 1.

Kahler, S. W.↗

X-Ray Optics: Past, Present, and Future

X-ray astronomy started with a small collimated proportional counter atop a rocket in the early 1960s. It was immediately recognized that focusing X-ray optics would drastically improve both source location accuracy and source detection sensitivity. In the past 5 decades, X-ray astronomy has made significant strides in achieving better angular resolution, large photon collection area, and better spectral and timing resolutions, culminating in the three currently operating X-ray observatories: Chandra, XMM/Newton, and Suzaku. In this talk I will give a brief history of X-ray optics, concentrating on the characteristics of the optics of these three observatories. Then I will discuss current X-ray mirror technologies being developed in several institutions. I will end with a discussion of the optics for the International X-ray Observatory that I have been developing at Goddard Space Flight Center.

Zhang, William W.↗

An Investigation into the Elementary Temporal Structure of Solar Flare Hard X-Ray Bursts Using BATSE

The research performed under this contract is part of an on-going investigation to explore the finest time-resolution hard X-ray data available on solar flares. Since 1991, the Burst and Transient Source Experiment (BATSE) aboard the Compton Gamma Ray Observatory has provided almost continual monitoring of the Sun in the hard X-ray and gamma-ray region of the spectrum. BATSE provides for the first time a temporal resolution in the data comparable to the timescales on which flare particle energization occurs. Under this contract, we have employed an important but under-utilized BATSE data type, the Time-To-Spill (TTS) data, to address the question of how fine a temporal structure exists in flare hard X-ray emission. By establishing the extent to which "energy release fragments," or characteristic (recurrent) time structures, are building blocks of flare emission, it is possible to place constraints on particle acceleration theories. We have utilized a spectral estimation technique, known as Lomb's normalized periodogram, to overcome the challenge of computing the power spectra of the unevenly sampled TTS data. By comparing the flare's power spectra to the expected power arising from Poisson noise, we obtain measurements of the smallest, statistically significant timescales present in the data. We have found, in an initial sample of 100 flares, that the smallest statistically significant timescales detected in a single flare are: 89 ms (30 May 1991 11:26:06) in channel 0, 117 ms (17 May 1991 09:03:20) in channel 1, 167 ms (31 May 1991 16:53:12) in channel 2, and 1.55 s (06 June 1991 01:02:08) in channel 3. We have also found some evidence for the existence of preferred timescales, however, the significance of this finding awaits a larger sample of flares.

Newton , Elizabeth↗

An Investigation into the Elementary Temporal Structure of Solar Flare Hard X-Ray Bursts Using BATSE

The research performed under this contract is part of an on-going investigation to explore the finest time-resolution hard X-ray data available on solar flares. Since 1991, the Burst and Transient Source Experiment (BATSE) aboard the Compton Gamma Ray Observatory has provided almost continual monitoring of the Sun in the hard X-ray and gamma-ray region of the spectrum. BATSE provides for the first time a temporal resolution in the data comparable to the timescales on which flare particle energization occurs. Under this contract, we have employed an important but under-utilized BATSE data type, the Time-To-Spill (TTS) data, to address the question of how fine a temporal structure exists in flare hard X-ray emission. By establishing the extent to which 'energy release fragments,' or characteristic (recurrent) time structures, are building blocks of flare emission, it is possible to place constraints on particle acceleration theories.

Newton, Elizabeth↗

Energy flux and characteristic energy of an elemental auroral structure

Electron density profiles acquired with the EISCAT radar at 0.2 s time resolution, together with TV images and photometric intensities, were used to study the characteristics of thin (less than 1 km) auroral arc structures that drifted through the field of view of the instruments. It is demonstrated that both high time and space resolution are essential for deriving the input parameters of the electron flux responsible for the elemental auroral structures. One such structure required a 400 mW/sq m (erg/sq cm s) downward energy flux carried by an 8 keV monochromatic electron flux equivalent to a current density of 50 micro Angstrom/sq m.

Lanchester, B. S.↗

BATSE flare observations in Solar Cycle 22

The Hard X-Ray Burst Spectrometer (HXRBS) group at GSFC has developed and is maintaining a quick-look analysis system for solar flare hard x-ray data from the Burst and Transient Source Experiment (BATSE) on the recently launched Compton Gamma-Ray Observatory (GRO). The instrument consists, in part, of 8 large planar detectors, each 2025 sq cm, placed on the corners of the GRO spacecraft with the orientation of the faces being those of a regular octahedron. Although optimized for the detection of gamma-ray bursts, these detectors are far more sensitive than any previous spacecraft-borne hard x-ray flare instrumentation both for the detection of small microflares and the resolution of fine temporal structures. The data in this BATSE solar data base are from the discriminator large area (DISCLA) rates. From each of eight detectors there are hard x-ray data in four energy channels, 25-50, 50-100, 100-300, and greater than 300 keV with a time resolution of 1.024 seconds. These data are suitable for temporal correlation with data at other wavelengths, and they provide a first look into the BATSE and other GRO instrument flare data sets. The BATSE and other GRO principle investigator groups should be contacted for the availability of data sets at higher time or spectral resolution or at higher energies.

Schwartz, R. A.↗

The motional Stark effect diagnostic for ITER

An overview of the plans for the motional Stark effect (MSE) diagnostic installation on the International Thermonuclear Experimental Reactor (ITER) is presented. The MSE diagnostic uniquely provides spatially localized magnetic field measurements inside the plasma. These are used to constrain equilibrium reconstructions to determine q(r), the safety factor as a function of minor radius. Meeting the system requirements to deliver q-profiles and related quantities with the specified radial resolution of 20 points over the minor radius, 10 ms time resolution, and better than 10% accuracy is challenging. MSE systems observe the D/H-α emission near 656.3 nm from neutral beams. As the beam atoms traverse the magnetic field, B⃗, at high velocity, v⃗, they experience a Lorentz electric field, v⃗×B⃗, which causes the spectral emission to be split and polarized due to the Stark effect. Traditional MSE-LP (line polarization) measurements determine the direction of the magnetic field in the observation volume using polarimetric analysis of the detected light. The harsh conditions of ITER are expected to deposit thin films of contaminants on the first mirror, which would alter the polarization state of reflected light significantly. On ITER, the combination of high magnetic field strength and high energy beams makes the Stark spectrum resolution suitable for the determination of the magnetic field magnitude from the line shift, so this approach has been selected. Every aspect of the measurement system must be planned for the burning plasma environment and carefully analyzed ahead of time. Current status and plans for the system are presented.

Instruments & Instrumentation↗

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗

A directional low energy gamma-ray detector

The sensitivity of a directional gamma ray detector, which relies on blocking a source to determine its direction and energy spectrum, is calculated and compared to the more conventional well-shaped shielded detectors. It is shown that such an anticollimator detection system provides a basis for measuring the celestial diffuse gamma ray background, gamma ray sources and bursts with good energy, angular, and time resolution, and that additionally the system is 20 to 50 times as sensitive as conventional detectors when compared on a per unit mass basis.

Morfill, G.↗

A directional low energy gamma-ray detector

The sensitivity of a directional gamma ray detector, which relies on blocking a source to determine its direction and energy spectrum, is calculated and compared to the more conventional well shaped shielded detectors. It is shown that such an anticollimator detection system provides a basis for measuring the celestial diffuse gamma ray background, gamma ray sources and bursts with good energy, angular, and time resolution, and that additionally the system is 20 to 50 times as sensitive as conventional detectors when compared on a per unit mass basis.

Morfill, G.↗