Search NASA⌕ Search

SEARCH · Search NASA

Results for “Waste Minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Physics Design of Proton/Ion SRF Accelerators

Superconducting Radio Frequency (SRF) technology has become foundation of the modern high energy particle accelerators. The technology enables a higher accelerating field with minimal power dissipation and a stronger compact magnetic field. These advancements have broadened the operational horizon of the particle accelerators making a higher duty factor and Continuous Wave (CW) beam operations both feasible and economically viable. The intensity frontier research founded on generation of intense beam of exotic particles including but not limited to neutrinos, muons, kaons and neutrons as well as practical applications involving transmutation of nuclear reactor waste, rare isotopes generation, sub-critical nuclear power generation etc. could be accomplished efficiently only by using superconducting proton/ions particle accelerators. As a result, many newly constructed or under construction high energy accelerator facilities around the world such as Proton Improvement Plan-II (PIP-II) at Fermilab, FRIB at MSU, ESS at Sweden are utilizing SRF accelerators. This talk presents the design philosophy of SRF proton/ion particle accelerator, with a focus on optimizing its performance while addressing physics and operational challenges including the fault scenarios, machine availability and preservation of crucial beam parameters.

Saini, Arun↗

Plastic Parallel Pathways Platform - 4P Model

Global momentum is building towards a circular economy capable of keeping plastics in use and out of waste streams. Given that 79% of all plastic produced since 1950 has accumulated in landfills or the natural environment,rapid implementation of various end-of-life (EoL) management technologies will be needed to reach this target. However, it can be challenging to develop an effective plastic EoL strategy when the available options - chemical or molecular recycling, energy recovery, upcycling, downcycling, closed-loop (plastic-to-plastic) or open-loop (plastic-to-x) recycling, among others - can generate products ranging from low-grade to virgin-quality plastic and from fuels to value-added chemicals. We present a flexible material flow model capable of analyzing the effects of both plastic-to-plastic and plastic-to-x EoL management strategies on the U.S. PET economy. This Plastic Parallel Pathways Platform (4P) assesses the environmental impacts, costs, and circularity of a PET system in which waste is managed through six potential EoL pathways: landfill, incineration with energy recovery, pyrolysis to fuel oil, upcycling to glass fiber reinforced plastic (GFRP), mechanical recycling to low-grade PET, and chemical recycling (glycolysis) to bottle-grade PET. We compare the pathways across multiple metrics using multi-criteria decision analysis (MCDA) and then use a brute force algorithm to predict an optimal combination of EoL pathways to minimize greenhouse gas (GHG) emissions and costs and maximize circularity. This work highlights the need to implement a diverse portfolio of EoL strategies in parallel to enable a PET economy that meets environmental, economic, and circularity requirements simultaneously.

downcycling↗

Residual Insoluble Solids Expected from Saltcake Dissolution

A review of previous SRS saltcake dissolution and characterization studies was performed to inform the analysis of the amount of residual insoluble solids that may result from saltcake dissolution. A realistic value covering most cases for the maximum volume of a settled layer of residual insoluble solids that would result from dissolution of a volume of saltcake was calculated as 0.08 mL/mL (8 vol%). Applying factors to account for dissolution test uncertainty and differences between in-tank settling and laboratory testing, the recommended value for a settled layer of residual insoluble solids that would result from dissolution of a volume of saltcake is 0.16 mL/mL (16 vol%). This should apply to dissolution of saltcake with typical minimal amounts of entrained sludge but may not apply to saltcake with significant sludge. As it is composed of primarily non-radioactive isotopes, the precipitated aluminum hydroxide material does not contribute to the heat load.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cryogenic Carbon Capture™ (CCC) Status Report

The Cryogenic Carbon Capture™ (CCC) process separates CO2 from light gases in essentially any continuous process. CCC cools the gases to the frost or desublimation point of CO2 (-100 to -135 °C), separates and pressurizes the solids, and warms all streams to produce a CO2-depleted stream at ambient pressure and a pure (99+%) pressurized liquid CO2 stream typically to about 150 bar, both at ambient temperature. The process also recovers all gas moisture and most gas impurities less volatile than CO2 (NOx, SOx, Hg, PM, UHC, CCC, etc.) in separable streams. CCC nearly eliminates refrigeration energy for sensible temperature changes through heat integration. CCC does require energy to change the CO2 phase from a mixed vapor to a pressurized fluid, which represents the minimum energy required of any process for this separation. CCC uses additional energy for turbomachinery inefficiencies, heat losses, moisture removal and overall process pressure drop. Aside from these real-world energy demands, CCC operates near the minimum energy required to perform this gas separation by minimizing stream recycling. CCC compresses CO2 as a liquid, which is one of several reasons it costs about about half as much and consumes about half as much energy as an amine process when using flue gases with about 15% CO2. The process also has several major additional advantages, including (a) it is a bolt-on retrofit technology that does not need steam or any modification of existing equipment, (b) it recovers water and nearly all pollutants in addition to CO2 from the flue gas, (c) it enables highly efficient and cost effective energy storage at grid scale and on time scales of minutes, (d) it enables NG storage if the energy storage option is used, and (d) it has a small footprint and is minimally disruptive to existing plants, requiring only electrical power and a gas source to operate. Sustainable Energy Solutions (SES) has scaled this technology through several levels, the largest of which captures nominally 1 tonne of CO2/day and is called the skid system. Skid system field tests include utility-scale power plants, cement plants, heating plants, and other utility or industrial sites that burn natural gas, biomass, coal, shredded tires, municipal waste, and combinations of these fuels. These field tests produced 95-99% CO2 capture with CO2 purities of 99+% and initial CO2 contents that range from 4 to 28%. SES currently seeks to scale the system to merchant scale (10-80 tonnes of CO2 per day). In the process of doing so, SES has demonstrated the potential for CCC to contribute to energy storage and direct air capture in innovative and cost-effective ways. This presentation discusses the overall process and highlights results from field and in-house tests. These include (a) measured CO2 capture rates and operating conditions from in-house and field tests, and (b) predicted utility-scale costs and energy demands. This discussion also includes the application of the CCC technology to energy storage and direct air capture.

20 FOSSIL-FUELED POWER PLANTS↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

The Savannah River National Laboratory (SRNL) was requested to develop a new antifoam control method for the Defense Waste Processing Facility’s (DWPF) Chemical Process Cell (CPC). SRNL completed testing of both chemical and nonchemical foam controls. The nonchemical foam controls were either ineffective (or worse, created more foam) or impractical (a water spray can control foam, but excessive water is needed). As a result, the focus of this study was on finding a superwetter or commercial antifoam for controlling foam. Thirty potential antifoams were tested as part of this study. A series of tests were developed to help screen out ineffective alternatives including: 1. Spreading testing of superspreaders, 2. Foam column testing with physical simulants, 3. Boiling testing with physical and chemical simulants, 4. Days-only Sludge Receipt and Adjustment Tank (SRAT) process simulations with sludge (containing noble metals and mercury), Precipitate Reactor Feed Tank (PRFT), and Slurry Mix Evaporator Feed Tank (SEFT) simulants in the RC1 Reaction Calorimeter (purchased for antifoam testing), and 5. Around-the-clock SRAT and Slurry Mix Evaporator (SME) process simulations with sludge(containing noble metals and mercury), PRFT, and SEFT simulants in the RC1 Reaction Calorimeter. Evonik Surfynol® MD20, a commercially available defoamer, was relatively effective in controlling foam, while remaining chemically stable in SRAT and SME processing across the pH range of 4 to 13. No degradation products were detected in the offgas, in the condensate or in the SRAT and SME products. In nitric-glycolic acid flowsheet testing, 250 mg/kg Evonik Surfynol® MD20 was needed for foam control compared to 1,625 mg/kg for Antifoam 747, DWPF’s current antifoam. In nitric-formic acid flowsheet testing, 1,125 mg/kg of Evonik Surfynol® MD20 was needed to control foam throughout the SRAT and SME cycles. The commercially available superspreader Momentive™ Y-17112 was even more effective than Evonik Surfynol® MD20 as both a defoamer and an antifoam. Not only was the foam destroyed upon addition but also was less persistent between additions. It was the most effective antifoam in testing using both the nitric-glycolic acid flowsheet and the nitric-formic acid flowsheet. In nitric-glycolic acid flowsheet testing, only 100 mg/kg Momentive™ Y-17112 was needed to control foam throughout the SRAT and SME cycles. In nitric-formic acid flowsheet testing, 300 mg/kg Momentive™ Y-17112 was needed to control foam throughout the SRAT and SME cycles. Momentive™ Y-17112 is also resistant to hydrolysis as demonstrated by its chemical stability in SRAT and SME processing across the pH range of 4 to 13 and lack of degradation products in offgas or condensate. Both candidates were effective as potential replacements for Antifoam 747, with Y-17112 demonstrating superior foam control. During nitric-glycolic flowsheet testing 50% less antifoam was needed when using Momentive™ Y-17112 compared to MD20. During nitric-formic flowsheet testing 75% less antifoam was needed when using Momentive™ Y-17112 compared to MD20. Foam remediated with Momentive™ Y-17112 was less persistent throughout testing. In addition, no degradation products were detected in the offgas, in the condensate or in the SRAT and SME products. Based on this testing, Momentive™ Y-17112 is clearly superior to Evonik Surfynol® MD20 and Antifoam 747, especially for the nitric-formic acid flowsheet processing; it is recommended that Momentive™ Y-17112 replace Antifoam 747 in DWPF. An antifoam addition strategy is recommended for both the nitric-glycolic acid flowsheet and the nitric-formic acid flowsheet. Implementation of Momentive™ Y-17112 is expected to decrease SRAT and SME boiling times by up to 50%, eliminate the issues resulting from Antifoam 747 degradation products, and minimize foamovers. To validate the effectiveness of these defoaming agents, SRNL recommends irradiation of a SRAT or SME product simulant containing fresh antifoam. The goal of this testing is to determine whether the irradiation causes decomposition of the antifoam that would make it less effective or produce new species in the offgas or slurry. This testing began in April 2020. An evaluation should be completed to determine the thermolytic hydrogen and methane generation rate in downstream equipment, including the High-Level Waste evaporators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrating Data Sources for Improved Safeguards and Accountancy of Electrochemical Fuel Reprocessing Systems. Final Report

Electrochemical reprocessing (also commonly known as “pyroprocessing”) of used nuclear fuel is an alternative to aqueous reprocessing that confers a number of advantages, including the ability to process more recently-discharged fuel, smaller resultant waste volumes, and the lack of isolation of plutonium in the product stream. While electrochemical reprocessing systems have seen a significant research and development effort, nuclear safeguards and security of these systems remains under-developed, particularly given the significant differences in operating environment and process flowsheet compared with established aqueous methods. Objective 4 of DOE’s nuclear energy research and development activities in Nuclear Energy Research and Development Roadmap is: “Understand and minimize the risks of nuclear proliferation and terrorism.” Material Control & Accountancy (MC&A) programs at nuclear processing plants deter and detect theft and diversion of nuclear material by both outside and inside adversaries. Empirical modeling and data analytics of online measurements and state indicators can improve the timeliness of detection and reduce the uncertainty in accountancy measures. To support the development and demonstration of such methods, data are needed that capture expected measurement values collected throughout electrochemical reprocessing facilities. A review of the available literature of current research in measurements for electrochemical reprocessing systems identified twenty-two candidate measurement methodologies, which characterize fuel/salt composition, concentrations of various isotopes and elements, and operational parameters throughout the reprocessing facility. Four primary measurement methodologies have been simulated based on either physical simulations or empirical correlations: gamma emissions, neutron emissions, hybrid k-edge densitometry (HKED), and cyclic voltammetry. Initial investigation into the use of these measures for process monitoring and detection suggests the approach is viable and worthy of further investigation. This report summarizes efforts to generate signatures of key measurements during operation of electrochemical reprocessing facilities and initial investigation of data analytics to support process monitoring, diversion detection, and accountancy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance evaluation of cosmic ray muon trajectory estimation algorithms

Muons, being elementary particles with minimal interaction with nuclear materials and abundant at sea level, have sparked interest in utilizing them for imaging various applications, such as mining [Borselli et al., Sci. Rep. 12, 22329 (2022)], volcano imaging [Nagamine et al., Nucl. Instrum. Meth. A, 356, 585(1995)], and underground tunnel detection [Guardincerri et al., Pure Appl. Geophys. 174, 2133 (2017)]. Recently, their use in nuclear nonproliferation and safeguard verification has gained attention, particularly in cargo screening for nuclear waste smuggling [Baesso et al., J. Instrum. 9, C10041 (2014)], source localization [L. J. Schultz et al., Nucl. Instrum. Meth. A 519, 687 (2004)], and locating nuclear fuel debris in reactors [Borozdin et al., Phys. Rev. Let. 109, 152501 (2012)]. However, the resolution of muon image reconstruction techniques is limited due to multiple Coulomb scattering (MCS) within the target object. To achieve robust muon tomography, it is crucial to develop efficient and flexible physics-based algorithms that can model the MCS process accurately and estimate the most probable trajectory of muons as they pass through the target object. To address this limitation, in this study, a novel algorithmic approach utilizing the Bayesian probability theory and Gaussian approximation of MCS is chosen. Different energy levels, materials, and target sizes were considered in the evaluations. The results demonstrate that the Generalized Muon Trajectory Estimation (GMTE) algorithm offers significant improvements over currently used algorithms. Across all test scenarios, the GMTE algorithm demonstrated ~50% and 38% increase in precision compared to Straight Line Path (SLP) and Point of Closest Approach (PoCA) algorithms, respectively. Furthermore, it exhibited 10%–35% and 10%–15% increases in muon flux utilization for high and medium Z materials, respectively, compared to the PoCA algorithm. In conclusion, the extensive simulations confirm the enhanced performance and efficiency of the GMTE algorithm, offering improved resolution and reduced measurement time for cosmic ray muon imaging compared to the current SLP and PoCA algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultrafiltration separation of Am(VI)-polyoxometalate from lanthanides

Partitioning of americium from lanthanides (Ln) present in used nuclear fuel plays a key role in the sustainable development of nuclear energy. This task is extremely challenging because thermodynamically stable Am(III) and Ln(III) ions have nearly identical ionic radii and coordination chemistry. Oxidization of Am(III) to Am(VI) produces AmO 2 2+ ions distinct with Ln(III) ions, which has the potential to facilitate separations in principle. However, the rapid reduction of Am(VI) back to Am(III) by radiolysis products and organic reagents required for the traditional separation protocols including solvent and solid extractions hampers practical redox-based separations. Herein, we report a nanoscale polyoxometalate (POM) cluster with a vacancy site compatible with the selective coordination of hexavalent actinides ( 238 U, 237 Np, 242 Pu and 243 Am) over trivalent lanthanides in nitric acid media. To our knowledge, this cluster is the most stable Am(VI) species in aqueous media observed so far. Ultrafiltration-based separation of nanoscale Am(VI)-POM clusters from hydrated lanthanide ions by commercially available, fine-pored membranes enables the development of a once-through americium/lanthanide separation strategy that is highly efficient and rapid, does not involve any organic components and requires minimal energy input.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Risk to Ecological Resources on Burial Waste Sites on the Hanford Site, Washington - 20248

The US and other nations have a large nuclear and chemical waste remediation task remaining from World War II, the Cold War, and industrial activities. The US Department of Energy (DOE) has the largest task in the U.S., with Hanford (Washington State) being the most contaminated site, with the longest and most costly cleanup program projected to extend to the end of the century. One of the greatest remediation problems at Hanford are the burial waste facilities, some of which are inside the 200 Areas on the Central Plateau, while others are outside the 200 Areas. These areas are associated with waste sites, pipes, and contaminated trenches, posing technical cleanup challenges to meet DoE's remediation goals, including protection of human health and the environment commensurate with Tri- Party Agreement and current regulatory requirements. In this paper we select one of the legacy waste sites (the BC Cribs and Trenches) as a case study to explore how risk to ecological resources varies during and as a consequence of remediation on sites primarily considered legacy waste sites. We used the risk methodology developed by the Consortium for Risk Evaluation with Stakeholder Participation (CRESP) during the Hanford Site-wide Risk Review. The CRESP methodology included evaluating the risk to receptors, including human health, the Columbia River, groundwater, and ecological and cultural resources. The risk evaluation process for ecological receptors included defining the boundaries of each evaluation unit (EU) to be remediated, definition of a suitable buffer area that might be affected, and consideration of the known resource value based on field work. This information, coupled with known remediation options or strategies, allowed us to develop a risk rating for ecological resources. Site risks were evaluated on a scale of 'not discernible' to 'very high' risk. Consideration of the risks at the buried waste sites was complicated by uncertainties in remediation methods and the degree of restoration that would occur as part of the remediation process. We use the BC Cribs and Trenches as a case study to explore why the risks are low currently but increase during remediation. The current 'not discernible to low' risk rating is due to the lack of high quality ecological resources on the BC Cribs and Trenches EU, except for edge areas (with some state-listed species). During remediation the risks increase to 'medium', mainly due to high quality resources on adjacent buffer lands, which could be disrupted during active remediation. Medium and high quality resources on the edge of the site are continuous with higher quality native shrub-steppe habitat on the buffer. Ecological resources on some of the areas surrounding the 200 East and West Areas are some of the highest quality shrub-steppe areas on the Hanford Site, and risk to these resources could be prevented by planning before and during remediation to minimize disruption. For example, lay down areas for the BC Cribs and Trenches can be minimized by careful planning. Heavy truck and other vehicular traffic can be minimized. Spread of the noxious weeds now on some of the site can be prevented, and the spread of invasive species into the site (particularly near undisturbed shrub-steppe habitat) can be reduced. Further, the areas around and between the 200 East and West Areas have been largely undisturbed and can serve as a source of seeds and propagules for any revegetation that occurs as part of the remediation process. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel design optimization framework to sustain remanufacturability

The ever-increasing global carbon emissions have urged the need for environmentally conscious/sustainable product design, for which the design for remanufacturing (DfRem) is one potential approach. DfRem targets at designing products that have multiple life cycles, thus significantly reducing raw material usage, energy consumption, and carbon emissions. In this paper, we develop a three-stage framework that consists of (1) systematic design space exploration and a multi-objective optimization formulation to minimize the likelihood of failure causes (such as fatigue and wear) and environmental footprint, (2) topology optimization to further reduce material usage without significantly affecting the load-carrying capability of the product, and (3) post-topology optimization design verification to ensure the proposed design satisfies all design constraints. The environmental impact can be assessed at varying comprehensiveness levels (e.g., design and manufacturing phase, use phase) and in terms of carbon or GHG emission, energy use, and waste generation. Because the novel design framework predominantly adjusted the geometry, we focused on mass-based change and energy savings due to sustained remanufacturability. The multi-objective optimization formulation in the first step results in a Pareto optimal set of possible design solutions that the designer can use for the second step. Finally, we demonstrate the utility of this framework through a case study of an engine cylinder head subjected to thermo-mechanical loads, where we find that about 5% of the product mass can be conserved with only about a 3% increase in surface area that has a fatigue life less than 10,000 cycles.

42 ENGINEERING↗

Technoeconomic optimization of superalloy supercritical CO 2 microtube shell-and-tube-heat exchangers

Heat exchangers are critical components of aerospace systems and improve efficiency of operation by providing waste heat recovery. Supercritical CO has emerged as a promising candidate working fluid due to its potential in increasing the power density of heat exchangers. In this paper, a generalized costing model is developed to estimate the capital costs incurred to manufacture microtube shell-and-tube heat exchangers. This model is utilized in conjunction with an accurate and efficient 2D numerical shell-and-tube heat exchanger performance prediction model to conduct optimization studies with two key objectives – minimization of cost and maximization of heat exchanger power density – on supercritical CO microtube heat exchangers utilizing superalloy Haynes 282 as the solid material. A methodology is then demonstrated to optimize these heat exchangers using Particle Swarm Optimization for aerospace applications and highly compact and cost-effective optimal designs with power density around 20 and cost per conductance less than 5 $ ∙ K/W are obtained.

42 ENGINEERING↗

Supercritical CO2 Recuperators, Presented at The ASME Turbo Expo 2017, June 29, 2017, by Dr. John Kelly, President, Altex Technologies Corporation

Closed Brayton super-critical CO2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m3/UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO2. Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $1,500/UA. In addition, the 5,083 kW unit HELC cost of $61.09/kW is 33.6% lower than the $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

High Effectiveness, Compact, High Pressure and Low-Cost Recuperator, Presented at The Fifth International Symposium – Super-Critical CO2 Power Cycles, San Antonio, Texas, March 28-31, 2016, by Dr. John Kelly, President, Altex Technologies Corporation

Closed Brayton super-critical CO2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m3/UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO2. Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $1,500/UA. In addition, the 5,083 kW unit HELC cost of $61.09/kW is 33.6% lower than the $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

Maximizing the Proppant Carrying and Viscoelastic Properties of the Bakken Hypersaline-Produced Water with High-Viscosity Friction Reducers for Sustainable Applications

Summary The development and production of unconventional reservoirs, such as the Bakken Formation, have become a resolved mystery for operators in North America since the arrival and advancement of horizontal drilling and hydraulic fracturing technologies. As a result, unconventional reservoir assets became the central focus of the oil and gas industry at the state, national, and global levels. The produced water from these activities in the Bakken Formation have high salt contents (110,000–350,000 ppm) total dissolve solids (TDS) and can pose significant challenges to the environment if not treated. Deep injection into disposal wells is the routine method used to get rid of the Bakken produced water. However, there have been some concerns that unrestrained injections, in addition to polluting the groundwater, could potentially lead to seismic activities either at the time of injection or in the near future. To diminish the environmental impacts that may be associated with induced seismicity, including the reduction of the costs of water acquisition, the produced water can be treated and reused in the hydraulic fracturing processes. Also, the treated water could be used for irrigation purposes, for power generation, and coal mining operations. The issues of waste water and residual oil high in TDS are challenges yet to be effectively addressed despite preceding research and studies on advancing produced water technologies. The goal of this study is to explore all applicable ways by which the produced water from the Bakken Formation can serve as a replacement base fluid for use with polymers like the high-viscosity friction reducers (HVFRs) to create hydraulic fracturing fluids that can be stable with reservoir conditions and also be able to minimize environmental impacts and cost of operations. Experimental investigations using the high-salinity produced water from the Bakken Formation with HVFRs were carried out. The studies included a base case that served as a bench mark for comparing the effectiveness of the other scenarios. The results indicate that the Bakken hyper-saline produced water can withstand effect of heavy metals, salinity, hardness and remain stable through different shear rates (66–330 s−1) when treated with higher dosages [4–8 gal/1,000 gal (gpt)] of HVFRs. Filtration and dilution were the only methods used on the Bakken Formation produced wate for this research

Engineering↗

Evaluation of a Potential Groundwater Tracer Test in the Ringold Upper Mud Aquifer at the 100-H Area of the Hanford Site

This document presents an evaluation of a potential groundwater tracer test in the uppermost RUM (Ringold Formation member of Wooded Island – upper mud unit) aquifer in the 100-H Area of the Hanford Site. The results from field electrical resistivity tomography (ERT) investigations, numerical flow and transport (F&T) modeling, coupled ERT-F&T model simulations, and laboratory resin experiments provide the technical basis for evaluating tracer test scenarios that minimize impacts to the 100-HX pump and treat (HX P&T) operations, and maximize hydrologic data acquisitions including the use of advanced surface geophysical techniques for monitoring tracer transport.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of SRPPF ARS Effluent Variations on Magnesium Oxysulfate Solidification

A magnesium oxysulfate (MOS) grout formulation has been identified to solidify the liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery System (ARS). The formulation uses reactive, light burnt MgO (28 wt%), anhydrous MgSO 4 (10 wt%), and dead burnt MgO (62 wt%), resulting in a grout with good mixability, acceptable density, acceptable setting times, and a leachate pH around 9.4, within the assumed Waste Isolation Pilot Plant (WIPP) brine pH range. A series of tests were then designed to observe how this formula reacted to variations in the liquid effluent. Liquid effluent temperature, the caustic pH level, concentration of NaNO 3 , and the presence of neutralization products, trace metals, and/or sodium sulfate (all potential residuals found in the effluent from upstream processing), were evaluated to see how each impacts the grout mixing time, peak temperature, setting time, presence of bleed water, leachate pH, and density. The standard mix has an average mixing time of 18 minutes, peak temperature of 100.5 °C, and set time of 60 minutes. Increasing the temperature of the liquid effluent increased the reaction rate of the mix and reduced mixing and setting times. Between 30 and 40°C the change was relatively small, raising no more than 6 °C compared to the standard mix maximum temperature. Increasing the pH of the liquid effluent had no significant impact on the mix. The addition of neutralization products and trace metals had an overall impact of decreasing the reactivity of the mix. The addition of more ions in the liquid effluent, such as an increase in the concentration of NaNO 3 and the addition of Na 2 SO 4 , generally decreased the reactivity of the mix. None of the variations to the liquid effluent hindered solidification as indicated by the lack of bleed water found on all the samples. The leachate pH values for all mixes tested did not significantly vary from the expected pH of 9.4 and none of the density values fell below 1.8 g/cm 3 . Overall, changes to the liquid effluent were found to have a minimal impact on the formulation suggesting the grout's ability to properly form despite increased temperatures and the presence of residuals typically found in the liquid effluent from the ARS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Designing a repository in domal salt: The influence of design variants in different modelling environments

To understand the long-term environmental impact of disposing radioactive waste of in a deep geological repository and to optimise its design, performance assessments are used. In this study, four teams (COVRA, GRS, Quintessa, and DOE) modified the previously developed generic repository of DECOVALEX task F2 to identify commonalities and differences between the teams for specific changes in repository design. The teams tested six design modifications: (1) Replacing concrete abutments with run-of-mine salt; (2) Replacing the salt seal with a concrete abutment and using run-of-mine salt instead for the two concrete abutments in each drift seal; (3) Halving the size of the infrastructure area; (4) Using run-of-mine salt instead of gravel for backfilling the infrastructure area; (5) Disposal of spent nuclear fuel without the POLLUX-10 containers (6); Lower initial saturation of the spent nuclear fuel and vitrified waste disposal drifts. Despite different modelling strategies used, models agreed that a smaller infrastructure area has a limited effect on radionuclide transport. Responses to the absence of the two concrete abutments in each seal, the use of single large concrete abutments (200 m each), or the use of run-of-mine salt in the infrastructure area differ between teams due to differing modelling assumptions. Based on these results, the estimated efficacy of containment depends strongly on the model assumptions of each team. More specifically, it appears to depend on the compaction model used and therefore on the backfill material used in different areas of the repository. However, the drift seal appears to be a critical design element in all models, effectively limiting radionuclide transport by hydrologically disconnecting sections of the repository. Additional beneficial design choices include the use of dry salt in disposal drifts to limit radionuclide transport and reducing the infrastructure area costs and minimizing host rock damage.

DECOVALEX↗