Search NASA⌕ Search

SEARCH · Search NASA

Results for “circuit model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Fast and converged classical simulations of evidence for the utility of quantum computing before fault tolerance

A recent quantum simulation of observables of the kicked Ising model on 127 qubits implemented circuits that exceed the capabilities of exact classical simulation. We show that several approximate classical methods, based on sparse Pauli dynamics and tensor network algorithms, can simulate these observables orders of magnitude faster than the quantum experiment and can also be systematically converged beyond the experimental accuracy. Our most accurate technique combines a mixed Schrödinger and Heisenberg tensor network representation with the Bethe free entropy relation of belief propagation to compute expectation values with an effective wave function–operator sandwich bond dimension >16,000,000, achieving an absolute accuracy, without extrapolation, in the observables of <0.01, which is converged for many practical purposes. We thereby identify inaccuracies in the experimental extrapolations and suggest how future experiments can be implemented to increase the classical hardness.

Science & Technology - Other Topics↗

String Length Calculator v0.0.3

The string length calculator simplifies the choice of string length for photovoltaic power plants. It uses open source tools to model the system open-circuit voltage over time based on established approaches used in the field by principal engineers and suggests a string length.

Jain, Anubhav↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

On the practical usefulness of the Hardware Efficient Ansatz

Variational Quantum Algorithms (VQAs) and Quantum Machine Learning (QML) models train a parametrized quantum circuit to solve a given learning task. The success of these algorithms greatly hinges on appropriately choosing an ansatz for the quantum circuit. Perhaps one of the most famous ansatzes is the one-dimensional layered Hardware Efficient Ansatz (HEA), which seeks to minimize the effect of hardware noise by using native gates and connectives. The use of this HEA has generated a certain ambivalence arising from the fact that while it suffers from barren plateaus at long depths, it can also avoid them at shallow ones. In this work, we attempt to determine whether one should, or should not, use a HEA. We rigorously identify scenarios where shallow HEAs should likely be avoided (e.g., VQA or QML tasks with data satisfying a volume law of entanglement). More importantly, we identify a Goldilocks scenario where shallow HEAs could achieve a quantum speedup: QML tasks with data satisfying an area law of entanglement. We provide examples for such scenario (such as Gaussian diagonal ensemble random Hamiltonian discrimination), and we show that in these cases a shallow HEA is always trainable and that there exists an anti-concentration of loss function values. Our work highlights the crucial role that input states play in the trainability of a parametrized quantum circuit, a phenomenon that is verified in our numerics.

97 MATHEMATICS AND COMPUTING↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

A comprehensive model to capture electrical discharge and spark channel evolution during spark-ignition processes

Emissions reduction through engine efficiency improvements is a priority for automakers who have turned to unconventional engine operation such as highly dilute, boosted, and stratified charge. Given its importance to flame initiation and sustained turbulent flame propagation, reliable and accurate spark ignition models are necessary to design ignition systems that reduce cyclic indicated mean effective pressure (IMEP) variability and increase engine efficiency in these operation modes. In this paper, secondary electric circuit, short-circuit, blowout, and re-strike sub-models are added to the Lagrangian-Eulerian spark ignition (LESI) model to simulate electrical discharge and spark channel elongation in an inert cross-flow combustion vessel. First, the physics of the underlying sub-models are described and the governing equations discussed with the spark channel voltage expression playing a critical role. Then, the experimental and simulations setups are presented. The results section begins with the derivation of spark channel voltage from experimental results. Then, electrical discharge and spark channel elongation simulations in inert flows are carried out using LESI and compared against experimental results. Finally, the results validate the model's ability to accurately predict spark channel elongation, as well as the occurrence of short-circuits, blowouts, re-strikes, and end of discharge.

42 ENGINEERING↗

Editorial: Functional microcircuits in the brain and in artificial intelligent systems

Fundamental principles underlying higher-order cognitive functions remain elusive, but recent breakthroughs in neurophysiology and deep learning offer new perspectives. First, experimental studies have uncovered neural circuit motifs consisting of various neuron types; see Brain Initiative Cell Census Network (https://www.nature.com/collections/cicghheddj). For example, inhibitory neuron types expressing exclusive genes have specific targets and distinct functions (Pfeffer et al., 2013). Furthermore, diverse neuron types in cortex and their connectomes were identified in cortical columns (Jiang et al., 2015); see also Barth et al. (2016) for a debate on neuron types. Second, artificial neural networks were originally inspired by structures of the brain (McCulloch and Pitts, 1943) and could be trained to perform complex functions similar to human perception/cognition by deep learning (DL) (Lecun et al., 2015).

59 BASIC BIOLOGICAL SCIENCES↗

Microbead Encapsulation for Protection of Electronic Components

Here, this study investigates the application of microbeads as an innovative encapsulation technique to protect electronic components from harsh mechanical strain. Traditional encapsulation methods using hard epoxy provide substantial mechanical support but create thermal expansion mismatch issues, potentially leading to electronic component failure. We explore the use of finely powdered microbeads to achieve protective structures combining stiffness and energy absorption. The research focuses on key variables, including microbead size, microbead roughness, compaction of microbeads, and circuit board mounting in the encapsulation, all of which influence the encapsulation’s effectiveness. Experimental setups and testing protocols were developed to assess the performance of various microbead materials under different impact conditions. Results demonstrate that microbead encapsulation significantly reduces strain on circuit boards, minimizing the risk of damage during mechanical shocks. However, challenges remain, such as optimizing microbead characteristics and modeling their behavior within large-scale circuit board assemblies. Despite these challenges, the findings suggest that microbead encapsulation offers a promising alternative to conventional methods, enhancing the durability and reliability of electronic components in high-stress environments.

42 ENGINEERING↗

Distribution Grid Impacts of Community Solar [Slides]

Community solar (CS) projects often face uncertain interconnection costs and fees associated with distribution grid infrastructure upgrades required to connect the project. These costs can determine the economic viability of a CS project, but they are difficult to assess. Cost uncertainty can discourage new projects and prevent communities from accessing the benefits of community solar projects. At the same time, CS deployment strategies hold potential to defer or avoid some distribution costs due to new loads. To mitigate CS interconnection costs, it is important to find least-cost combinations of distribution system infrastructure solutions (transformer upgrades, reconductoring, voltage regulators, storage), and to understand how location of CS projects within a feeder impact distribution grid upgrade costs. This study aims to quantify CS impacts on the distribution grid and provide policy and regulatory insights and CS deployment strategies to address them. It is the first analysis that has systematically studied the technical impacts of community solar projects on a wide range of distribution feeders using state-of-the-art optimization and power flow tools. The analysis employs Berkeley Lab’s novel Least-cost Optimal Distribution Grid Expansion (LODGE) model, a deterministic version of the REPAIR model, that optimally upgrades hundreds or even thousands of distribution circuits or feeders. This is the first application of the LODGE model. LODGE finds the least-cost portfolio of traditional distribution system upgrades to integrate CS in combination with alternative solutions, such as utility-owned storage and downsizing CS capacity. Working with a set of least-cost solutions per feeder allows us to benchmark, compare and find techno-economic trends in CS interconnection.

14 SOLAR ENERGY↗

Glassy Word Problems: Ultraslow Relaxation, Hilbert Space Jamming, and Computational Complexity

We introduce a family of local models of dynamics based on “word problems” from computer science and group theory, for which we can place rigorous lower bounds on relaxation timescales. These models can be regarded either as random circuit or local Hamiltonian dynamics and include many familiar examples of constrained dynamics as special cases. The configuration space of these models splits into dynamically disconnected sectors, and for initial states to relax, they must “work out” the other states in the sector to which they belong. When this problem has a high time complexity, relaxation is slow. In some of the cases we study, this problem also has high space complexity. When the space complexity is larger than the system size, an unconventional type of jamming transition can occur, whereby a system of a fixed size is not ergodic but can be made ergodic by appending a large reservoir of sites in a trivial product state. This finding manifests itself in a new type of Hilbert space fragmentation that we call fragile fragmentation. We present explicit examples where slow relaxation and jamming strongly modify the hydrodynamics of conserved densities. In one example, density modulations of wave vector q exhibit almost no relaxation until times O ( exp ( 1 / q ) ) , at which point they abruptly collapse. We also comment on extensions of our results to higher dimensions. Published by the American Physical Society 2024

Physics↗

Hybrid Oscillator-Qubit Quantum Processors: Instruction Set Architectures, Abstract Machine Models, and Applications

This tutorial offers a pedagogical guide to hybrid quantum processors that integrate discrete-variable (DV) qubits and continuous-variable (CV) oscillators. Aimed at computer scientists, engineers, and physicists, it provides an overview of the experimental, algorithmic, and architectural aspects of this novel and rapidly developing hardware model. Experimental realizations of this model include superconducting, trapped-ion, and neutral-atom platforms. By combining DV and CV components, hybrid oscillator-qubit processors enable a powerful new paradigm that offers complementary strengths for quantum control, error correction, computation, and simulation. Working toward the goal of a full-stack system connecting applications to CV-DV hardware, we define and formulate abstract machine models and instruction set architectures. These essential abstractions enable codesign of hardware and software, and resource estimation for exploring the potential of current and future hardware for computational and simulation tasks. Using these abstractions, we present both new and existing examples that illustrate the benefits of hybrid CV-DV processors relative to traditional DV-only hardware in computation as well as quantum simulation of physical models. Examples include algorithms for transferring states between DV and CV systems, performing the quantum Fourier transform, and simulation of lattice gauge theories. Relative to qubit-only hardware, the bosonic degrees of freedom natively available in hybrid architectures can substantially reduce the circuit complexity of simulations for physical models containing bosons. A key technique is the extension of quantum signal processing ideas to CV-DV systems. This work is intended to serve as a timely and comprehensive guide to this relatively unexplored yet promising approach to quantum computation and to provide a road map to guide future development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Damage of prismatic lithium‐ion cells subject to bending: Test, model, and detection

Abstract The mechanically induced internal short circuit (ISC) is one of the major safety concerns of lithium‐ion batteries. Mechanical abuse tests are often performed to evaluate the integrity and safety of lithium‐ion batteries under mechanical loadings. Except for the widely explored compression‐dominated indentation tests, bending is another typical real‐world loading condition that is tension‐dominated. To investigate the mechanical damage and ISC behavior of batteries under bending, we carried out controlled three‐point bending tests in four progressive steps on prismatic battery cells with maximum deflections ranging from 38% to 76% of the cell thickness. None of the tested cells experienced an ISC. We then conducted 3D X‐ray computed tomography (CT) scanning on the bent cells after unloading. X‐ray CT images showed three out of the four tested cells have extensive cracking in the electrode layers at the bottom side (opposite to the loading head). This indicates that cracking does not necessarily lead to an ISC under bending. Electrochemical impedance spectroscopy was also measured on the bent cells and substantial changes were observed. Both the bulk resistance and charge‐transfer resistance increased significantly after bending, which could influence the battery performance and lifespan. We then developed a detailed finite (FE) element model to further investigate the mechanical deformation and failure mechanisms. The FE model successfully predicts the load–displacement response and reproduces the deformation patterns. The findings and the FE model developed in the present study provide useful insights and tools for the battery structure and crash safety design. image

25 ENERGY STORAGE↗

Frequency Stability Enhancement in a Fully Solar Power Grid: A Case Study on the Saudi Model

Recently, renewable energy sources (RES) such as solar photovoltaic (PV) have been recognized for their significant potential. Several studies have explored the issue of frequency stability with high RES penetration. A significant observation related to this issue is the decline in the weighted short circuit ratio (WSCR), which has the potential to adversely affect system stability. This research uniquely focuses on the gradual transition of the Saudi Electricity Company (SEC) system to a fully integrated solar PV grid, offering insight and methodology that can be adapted for other power systems. While a variety of mitigation methods are available, synchronous condensers (SC) were used in this study to stabilize grid frequency, and their implementation has been shown to improve the overall performance of the system. In response to the observed decline in WSCR, a comprehensive short circuit analysis was applied across all regions in the Saudi power grid model to evaluate the reduction in short circuit power and highlight areas requiring enhancement. Finally, scenarios illustrating frequency response with a gradual increase in SCR were analyzed, with the objective of establishing a stable, fully solar PV power system that is resilient to sudden power grid disturbances.

14 SOLAR ENERGY↗

Characterizing and Modeling the Influence of Geometry on the Performance of Superconducting Nanowire Cryotrons

The scaling of superconducting nanowire detectors to larger arrays is often limited by room-temperature-readout cabling. Cryogenic integrated circuits constructed from nanowire cryotrons, or nanocryotrons, can address this limitation by performing signal processing on chip. In this study, we characterize key performance metrics of the nanocryotron to elucidate its potential as a logical element in cryogenic integrated circuits and develop an electro-thermal model to connect material parameters with device performance. We find that the performance of the nanocryotron depends on the device geometry, and trade-offs are associated with optimizing the gain, jitter, and energy dissipation. Here, we demonstrate that nanocryotrons fabricated on niobium nitride can achieve a grey zone less than 210 nA wide for a 5 ns long input pulse corresponding to a maximum achievable gain of 48 dB, an energy dissipation of less than 20 aJ per operation, and a jitter of less than 60 ps.

Superconductor↗